{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T18:22:42Z","timestamp":1793816562936,"version":"4.6.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,10,7]],"date-time":"2021-10-07T00:00:00Z","timestamp":1633564800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,10,7]],"date-time":"2021-10-07T00:00:00Z","timestamp":1633564800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum des Saarlandes und Medizinische Fakult\u00e4t der Universit\u00e4t des Saarlandes"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Various plate shapes and implant configurations are used for stabilization of acetabulum fractures via anterior approaches. Little is known about the biomechanical stability of a two-dimensionally shaped \u201cconventional\u201d plate (\u201cJ-Plate\u201d\u2014JP) in comparison to three-dimensionally shaped plate configurations (3DP). In addition, the augmentary effect of an infra-acetabular lag-screw (IACS) fixation for anterior column and posterior hemi-transverse acetabulum fractures has not been clarified in comparison of JP and 3DP constructs. This study analyzed the difference between the biomechanical stability of JP compared to 3DP and the role of an IACS in a standardized acetabular fracture model in a single-leg stance loading configuration.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In an artificial bone substitute pelvis model (Synbone<jats:sup>\u00a9<\/jats:sup> Malans, Switzerland), a typical and standardized fracture pattern (anterior column and posterior hemi-transverse) was created with osteotomy jigs. After anatomic reduction the stabilization was performed using JP or 3DP. Eight pelvises per group were axially loaded in a single-leg stance model up to 400\u00a0N. After the load cycle, an additional infra-acetabular screw was placed and the measurement repeated. Fragment displacement was recorded by an optical tracking system (Optitrack Prime 13\u00ae, Corvallis, USA).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In the pure placement, 3DP provided significantly superior stability when compared to JP. Augmentation of JP by IACS increased the stability significantly, up to the level of 3DP alone, whereas augmentation of the 3DP did not result in further increase of overall stability.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The anatomically shaped plate alone provides a superior biomechanical stability in fixation of an anterior column and posterior hemi-transverse fracture model. In a JP fixation the augmentation by IACS provides similar strength as the anatomically shaped 3DP. By use of the anatomically shaped 3DP the need of a clinically risky application of IACS might be avoidable.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence<\/jats:title>\n                <jats:p>IV, Experimental study.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00068-021-01805-x","type":"journal-article","created":{"date-parts":[[2021,10,7]],"date-time":"2021-10-07T11:05:03Z","timestamp":1633604703000},"page":"3757-3764","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis"],"prefix":"10.1007","volume":"48","author":[{"given":"I.","family":"Graul","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I.","family":"Marintschev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Pizanis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S. C.","family":"Herath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Pohlemann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2007-0404","authenticated-orcid":false,"given":"T.","family":"Fritz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,10,7]]},"reference":[{"key":"1805_CR1","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1097\/BOT.0b013e3181b2b4ca","volume":"24","author":"RC Andersen","year":"2010","unstructured":"Andersen RC, O\u2019Toole RV, Nascone JW, Sciadini MF, Frisch HM, Turen CW. Modified stoppa approach for acetabular fractures with anterior and posterior column displacement: quantification of radiographic reduction and analysis of interobserver variability. J Orthop Trauma. 2010;24:271\u20138.","journal-title":"J Orthop Trauma"},{"key":"1805_CR2","doi-asserted-by":"publisher","first-page":"1793","DOI":"10.1016\/j.injury.2013.08.009","volume":"44","author":"JD Bastian","year":"2013","unstructured":"Bastian JD, Tannast M, Siebenrock KA, Keel MJ. Mid-term results in relation to age and analysis of predictive factors after fixation of acetabular fractures using the modified Stoppa approach. Injury. 2013;44:1793\u20138.","journal-title":"Injury"},{"key":"1805_CR3","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1186\/s13018-018-0786-1","volume":"13","author":"F Baumann","year":"2018","unstructured":"Baumann F, Schmitz P, Mahr D, Kerschbaum M, G\u00e4nsslen A, Nerlich M, Worlicek M. A guideline for placement of an infra-acetabular screw based on anatomic landmarks via an intra-pelvic approach. J Orthop Surg Res. 2018;13:77.","journal-title":"J Orthop Surg Res"},{"key":"1805_CR4","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1302\/0301-620X.87B10.16538","volume":"87","author":"DB Griffin","year":"2005","unstructured":"Griffin DB, Beaul\u00e9 PE, Matta JM. Safety and efficacy of the extended iliofemoral approach in the treatment of complex fractures of the acetabulum. J Bone Joint Surg Br Volume. 2005;87:1391\u20136.","journal-title":"J Bone Joint Surg Br Volume."},{"key":"1805_CR5","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1097\/00003086-199307000-00009","volume":"292","author":"E Letournel","year":"1993","unstructured":"Letournel E. The treatment of acetabular fractures through the ilioinguinal approach. Clin Orthop Related Res. 1993;292:62\u201376.","journal-title":"Clin Orthop Related Res"},{"key":"1805_CR6","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1007\/s10195-014-0297-8","volume":"15","author":"NK Magu","year":"2014","unstructured":"Magu NK, Gogna P, Singh A, Singla R, Rohilla R, Batra A, Mukhopadhyay R. Long term results after surgical management of posterior wall acetabular fractures. J Orthop Traumatol. 2014;15:173\u20139.","journal-title":"J Orthop Traumatol"},{"key":"1805_CR7","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.2106\/00004623-199611000-00002","volume":"78","author":"JM Matta","year":"1996","unstructured":"Matta JM. Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury. J Bone Joint Surg Am Volume. 1996;78:1632\u201345.","journal-title":"J Bone Joint Surg Am Volume"},{"key":"1805_CR8","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1097\/00003086-200302000-00026","volume":"407","author":"DC Mears","year":"2003","unstructured":"Mears DC, Velyvis JH, Chang CP. Displaced acetabular fractures managed operatively: indicators of outcome. Clin Orthop Related Res. 2003;407:173\u201386.","journal-title":"Clin Orthop Related Res"},{"key":"1805_CR9","doi-asserted-by":"publisher","first-page":"1559","DOI":"10.2106\/JBJS.K.00444","volume":"94","author":"M Tannast","year":"2012","unstructured":"Tannast M, Najibi S, Matta JM. Two to twenty-year survivorship of the hip in 810 patients with operatively treated acetabular fractures. J Bone Joint Surg Am Volume. 2012;94:1559\u201367.","journal-title":"J Bone Joint Surg Am Volume."},{"key":"1805_CR10","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1097\/00003086-199408000-00015","volume":"305","author":"JD Cole","year":"1994","unstructured":"Cole JD, Bolhofner BR. Acetabular fracture fixation via a modified Stoppa limited intrapelvic approach. Description of operative technique and preliminary treatment results. Clin Orthop Related Res. 1994;305:112\u201323.","journal-title":"Clin Orthop Related Res"},{"key":"1805_CR11","doi-asserted-by":"publisher","first-page":"1130","DOI":"10.1016\/j.injury.2010.11.060","volume":"42","author":"GY Laflamme","year":"2011","unstructured":"Laflamme GY, Hebert-Davies J, Rouleau D, Benoit B, Leduc S. Internal fixation of osteopenic acetabular fractures involving the quadrilateral plate. Injury. 2011;42:1130\u20134.","journal-title":"Injury"},{"key":"1805_CR12","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1016\/j.injury.2010.04.010","volume":"41","author":"BG Ochs","year":"2010","unstructured":"Ochs BG, Marintschev I, Hoyer H, Rolauffs B, Culemann U, Pohlemann T, Stuby FM. Changes in the treatment of acetabular fractures over 15 years: analysis of 1266 cases treated by the German Pelvic Multicentre Study Group (DAO\/DGU). Injury. 2010;41:839\u201351.","journal-title":"Injury"},{"key":"1805_CR13","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/j.injury.2009.12.001","volume":"41","author":"U Culemann","year":"2010","unstructured":"Culemann U, Holstein JH, K\u00f6hler D, Tzioupis CC, Pizanis A, Tosounidis G, Burkhardt M, Pohlemann T. Different stabilisation techniques for typical acetabular fractures in the elderly\u2013a biomechanical assessment. Injury. 2010;41:405\u201310.","journal-title":"Injury"},{"key":"1805_CR14","first-page":"244","volume":"70","author":"U Culemann","year":"2011","unstructured":"Culemann U, Marintschev I, Gras F, Pohlemann T. Infra-acetabular corridor\u2013technical tip for an additional screw placement to increase the fixation strength of acetabular fractures. J Trauma. 2011;70:244\u20136.","journal-title":"J Trauma"},{"key":"1805_CR15","doi-asserted-by":"publisher","first-page":"1664","DOI":"10.1097\/TA.0b013e3182463b45","volume":"72","author":"F Gras","year":"2012","unstructured":"Gras F, Marintschev I, Schwarz CE, Hofmann GO, Pohlemann T, Culemann U. Screw- versus plate-fixation strength of acetabular anterior column fractures: a biomechanical study. J Trauma Acute Care Surg. 2012;72:1664\u201370.","journal-title":"J Trauma Acute Care Surg"},{"key":"1805_CR16","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1016\/j.injury.2011.11.009","volume":"43","author":"I Marintschev","year":"2012","unstructured":"Marintschev I, Gras F, Schwarz CE, Pohlemann T, Hofmann GO, Culemann U. Biomechanical comparison of different acetabular plate systems and constructs\u2013the role of an infra-acetabular screw placement and use of locking plates. Injury. 2012;43:470\u20134.","journal-title":"Injury"},{"key":"1805_CR17","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1007\/s11999-014-3932-z","volume":"473","author":"F Gras","year":"2015","unstructured":"Gras F, Gottschling H, Schr\u00f6der M, Marintschev I, Reimers N, Burgkart R. Sex-specific differences of the infraacetabular corridor: a biomorphometric CT-based analysis on a database of 523 pelves. Clin Orthop Relat Res. 2015;473:361\u20139.","journal-title":"Clin Orthop Relat Res"},{"key":"1805_CR18","doi-asserted-by":"publisher","first-page":"e210","DOI":"10.1097\/BOT.0000000000000829","volume":"31","author":"F Gras","year":"2017","unstructured":"Gras F, Marintschev I, Grossterlinden L, Rossmann M, Graul I, Hofmann GO, Rueger JM, Lehmann W. The anterior intrapelvic approach for acetabular fractures using approach-specific instruments and an anatomical-preshaped 3-dimensional suprapectineal plate. J Orthop Trauma. 2017;31:e210\u20136.","journal-title":"J Orthop Trauma"},{"key":"1805_CR19","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1097\/BOT.0b013e318234d443","volume":"26","author":"F Gras","year":"2012","unstructured":"Gras F, Marintschev I, Klos K, M\u00fcckley T, Hofmann GO, Kahler DM. Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study. J Orthop Trauma. 2012;26:466\u201373.","journal-title":"J Orthop Trauma."},{"key":"1805_CR20","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1097\/BOT.0b013e3181c90bbe","volume":"24","author":"YR Farid","year":"2010","unstructured":"Farid YR. Cerclage wire-plate composite for fixation of quadrilateral plate fractures of the acetabulum: a checkrein and pulley technique. J Orthop Trauma. 2010;24:323\u20138.","journal-title":"J Orthop Trauma"},{"key":"1805_CR21","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1055\/s-0033-1360351","volume":"152","author":"A Sch\u00e4ffler","year":"2014","unstructured":"Sch\u00e4ffler A, D\u00f6bele S, Stuby F, Maucher M, Schr\u00f6ter S, St\u00f6ckle U, K\u00f6nig B. A new anatomical wing plate for osteoporotic acetabular fractures: biomechanical testing and first clinical experience. Zeitschrift fur Orthopadie und Unfallchirurgie. 2014;152:26\u201332.","journal-title":"Zeitschrift fur Orthopadie und Unfallchirurgie"},{"key":"1805_CR22","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1243\/09544119JEIM409","volume":"222","author":"R Zdero","year":"2008","unstructured":"Zdero R, Olsen M, Bougherara H, Schemitsch EH. Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis. Proc Inst Mech Eng Part H, J Eng Med. 2008;222:1175\u201383.","journal-title":"Proc Inst Mech Eng Part H, J Eng Med."},{"key":"1805_CR23","doi-asserted-by":"publisher","first-page":"W58","DOI":"10.1055\/s-2005-836926","volume":"130","author":"U Culemann","year":"2005","unstructured":"Culemann U, Tosounidis G, Pohlemann T. Fractures of the accetabulum\u2013treatment strategies and actual diagnostics. Zentralblatt fur Chirurgie. 2005;130:W58-71 (quiz W72-53).","journal-title":"Zentralblatt fur Chirurgie."},{"key":"1805_CR24","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1007\/s001130050455","volume":"102","author":"PM Rommens","year":"1999","unstructured":"Rommens PM. Hessmann MH [Acetabulum fractures]. Der Unfallchirurg. 1999;102:591\u2013610.","journal-title":"Der Unfallchirurg"},{"key":"1805_CR25","doi-asserted-by":"publisher","first-page":"3282","DOI":"10.1016\/j.jbiomech.2008.08.013","volume":"41","author":"AD Heiner","year":"2008","unstructured":"Heiner AD. Structural properties of fourth-generation composite femurs and tibias. J Biomech. 2008;41:3282\u20134.","journal-title":"J Biomech"},{"issue":"Suppl 2","key":"1805_CR26","doi-asserted-by":"publisher","first-page":"S8","DOI":"10.1097\/BOT.0000000000001406","volume":"33","author":"SC Herath","year":"2019","unstructured":"Herath SC, Pott H, Rollmann MFR, Braun BJ, Holstein JH, H\u00f6ch A, Stuby FM, Pohlemann T. Geriatric acetabular surgery: letournel\u2019s contraindications then and now-data from the German pelvic registry. J Orthop Trauma. 2019;33(Suppl 2):S8-s13.","journal-title":"J Orthop Trauma"},{"key":"1805_CR27","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.2106\/JBJS.17.00295","volume":"100","author":"C May","year":"2018","unstructured":"May C, Egloff M, Butscher A, Keel MJB, Aebi T, Siebenrock KA, Bastian JD. Comparison of fixation techniques for acetabular fractures involving the anterior column with disruption of the quadrilateral plate: a biomechanical study. J Bone Joint Surg Am Volume. 2018;100:1047\u201354.","journal-title":"J Bone Joint Surg Am Volume."},{"key":"1805_CR28","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1007\/s00264-018-4148-8","volume":"43","author":"C von R\u00fcden","year":"2019","unstructured":"von R\u00fcden C, Wenzel L, Becker J, Thannheimer A, Augat P, Woltmann A, B\u00fchren V, Perl M. The pararectus approach for internal fixation of acetabular fractures involving the anterior column: evaluating the functional outcome. Int Orthop. 2019;43:1487\u201393.","journal-title":"Int Orthop"},{"key":"1805_CR29","doi-asserted-by":"publisher","first-page":"323","DOI":"10.5301\/hipint.5000027","volume":"23","author":"MS Park","year":"2013","unstructured":"Park MS, Yoon SJ, Park JH, Choi SM. The management of the displaced medial wall in complex acetabular fractures using plates and additional cerclage. Hip Int. 2013;23:323\u20139.","journal-title":"Hip Int"},{"key":"1805_CR30","doi-asserted-by":"publisher","first-page":"2054","DOI":"10.1016\/j.injury.2017.07.020","volume":"48","author":"CA Spitler","year":"2017","unstructured":"Spitler CA, Kiner D, Swafford R, Doty D, Goulet R, Jones LC, Hydrick J, Nowotarski P. Generating stability in elderly acetabular fractures-A biomechanical assessment. Injury. 2017;48:2054\u20139.","journal-title":"Injury"},{"key":"1805_CR31","doi-asserted-by":"publisher","first-page":"2219","DOI":"10.1007\/s00264-015-2883-7","volume":"39","author":"TH Tosounidis","year":"2015","unstructured":"Tosounidis TH, Gudipati S, Panteli M, Kanakaris NK, Giannoudis PV. The use of buttress plates in the management of acetabular fractures with quadrilateral plate involvement: is it still a valid option? Int Orthop. 2015;39:2219\u201326.","journal-title":"Int Orthop"},{"key":"1805_CR32","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1186\/s12891-019-2422-6","volume":"20","author":"T Busuttil","year":"2019","unstructured":"Busuttil T, Teuben M, Pfeifer R, Cinelli P, Pape HC, Osterhoff G. Screw fixation of ACPHT acetabular fractures offers sufficient biomechanical stability when compared to standard buttress plate fixation. BMC Musculoskelet Disord. 2019;20:39.","journal-title":"BMC Musculoskelet Disord"},{"key":"1805_CR33","doi-asserted-by":"publisher","first-page":"1615","DOI":"10.2106\/00004623-196446080-00001","volume":"46","author":"R Judet","year":"1964","unstructured":"Judet R, Judet J, Letournel E. Fractures of the acetabulum: classification and surgical approaches for open reduction. Preliminary report. J Bone Joint Surg Am Volume. 1964;46:1615\u201346.","journal-title":"J Bone Joint Surg Am Volume."},{"key":"1805_CR34","doi-asserted-by":"publisher","first-page":"105009","DOI":"10.1016\/j.clinbiomech.2020.105009","volume":"77","author":"T Fritz","year":"2020","unstructured":"Fritz T, Mettelsiefen L, Strobel F, Braun BJ, Herath SC, Hopp SJ, Histing T, Pohlemann T, Pizanis A. A novel internal fixation method for open book injuries of the pubic symphysis- A biomechanical analysis. Clin Biomech (Bristol, Avon). 2020;77:105009.","journal-title":"Clin Biomech (Bristol, Avon)."},{"key":"1805_CR35","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1007\/s10439-009-9887-7","volume":"38","author":"MP Gardner","year":"2010","unstructured":"Gardner MP, Chong AC, Pollock AG, Wooley PH. Mechanical evaluation of large-size fourth-generation composite femur and tibia models. Ann Biomed Eng. 2010;38:613\u201320.","journal-title":"Ann Biomed Eng"},{"key":"1805_CR36","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1007\/s00064-009-1804-6","volume":"21","author":"A G\u00e4nsslen","year":"2009","unstructured":"G\u00e4nsslen A, Krettek C. Internal fixation of acetabular both-column fractures via the ilioinguinal approach. Operative Orthopadie und Traumatologie. 2009;21:270\u201382.","journal-title":"Operative Orthopadie und Traumatologie"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-021-01805-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-021-01805-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-021-01805-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T18:07:15Z","timestamp":1664906835000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-021-01805-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,7]]},"references-count":36,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["1805"],"URL":"https:\/\/doi.org\/10.1007\/s00068-021-01805-x","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,7]]},"assertion":[{"value":"6 July 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"In this study no human or animal specimen were used. No ethical statement was necessary.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical statement"}},{"value":"The authors state no conflict of interest for this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}