{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T12:39:34Z","timestamp":1770813574868,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2021,12,24]],"date-time":"2021-12-24T00:00:00Z","timestamp":1640304000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,12,24]],"date-time":"2021-12-24T00:00:00Z","timestamp":1640304000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Augsburg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2022,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Introduction<\/jats:title>\n                <jats:p>In spiral fractures of the tibia, the stability of an osteosynthesis may be significantly increased by additive cerclages and, according to biomechanical studies, be brought into a state that allows immediate full weight bearing. As early as 1933, Goetze described a minimally invasive technique for classic steel cerclages. This technique was modified, so that it can be used for modern cable cerclages in a soft part saving way.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Method<\/jats:title>\n                <jats:p>After closed reduction, an 8 Fr redon drain is first inserted in a minimally invasive manner, strictly along the bone and placed around the tibia via 1\u00a0cm incisions on the anterolateral and dorsomedial tibial edges using a curette and a tissue protection sleeve.<\/jats:p>\n                <jats:p>Via this drain, a 1.7\u00a0mm cable cerclage can be inserted. The fracture is then anatomically reduced while simultaneously tightening the cerclage. Subsequently, a nail or a minimally invasive plate osteosynthesis is executed using the standard technique.<\/jats:p>\n                <jats:p>Using the hospital documentation system, data of patients that were treated with additional cerclages for tibial fractures between 01\/01\/2014 and 06\/30\/2020 were subjected to a retrospective analysis for postoperative complications (wound-healing problems, infections and neurovascular injury). Inclusion criteria were: operatively treated tibial fractures, at least one minimally invasive additive cerclage, and age of 18\u00a0years or older. Exclusion criteria were: periprosthetic or pathological fractures and the primary need of reconstructive plastic surgery. SPSS was used for statistical analysis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>96 tibial shaft spiral fractures were treated with a total of 113 additive cerclages. The foregoing resulted in 10 (10.4%) postoperative wound infections, 7 of which did not involve the cerclage. One lesion of the profundal peroneal nerve was detected, which largely declined after cerclage removal. In 3 cases, local irritation from the cerclage occurred and required removal of material.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>In the described technique, cerclages may be inserted additively at the tibia in a minimally invasive manner and with a few complications, thus significantly increasing the stability of an osteosynthesis. How this ultimately affects fracture healing is the subject of an ongoing study.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00068-021-01857-z","type":"journal-article","created":{"date-parts":[[2021,12,24]],"date-time":"2021-12-24T09:02:46Z","timestamp":1640336566000},"page":"3115-3122","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["A minimally invasive cerclage of the tibia in a modified Goetze technique: operative technique and first clinical results"],"prefix":"10.1007","volume":"48","author":[{"given":"Stefan","family":"F\u00f6rch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Reuter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franziska","family":"von der Helm","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leonard","family":"Lisitano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Hartwig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabrina","family":"Sandriesser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Nuber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edgar","family":"Mayr","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,12,24]]},"reference":[{"issue":"11","key":"1857_CR1","doi-asserted-by":"publisher","first-page":"936","DOI":"10.2106\/JBJS.17.01222","volume":"100","author":"C Kammerlander","year":"2018","unstructured":"Kammerlander C, et al. Inability of older adult patients with hip fracture to maintain postoperative weight-bearing restrictions. J Bone Joint Surg Am. 2018;100(11):936\u201341.","journal-title":"J Bone Joint Surg Am"},{"key":"1857_CR2","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.bone.2014.02.014","volume":"63","author":"GJ Kazakia","year":"2014","unstructured":"Kazakia GJ, et al. The influence of disuse on bone microstructure and mechanics assessed by HR-pQCT. Bone. 2014;63:132\u201340.","journal-title":"Bone"},{"issue":"7","key":"1857_CR3","doi-asserted-by":"publisher","first-page":"1429","DOI":"10.1007\/s00590-018-2190-2","volume":"28","author":"IB Houben","year":"2018","unstructured":"Houben IB, et al. Delay in weight bearing in surgically treated tibial shaft fractures is associated with impaired healing: a cohort analysis of 166 tibial fractures. Eur J Orthop Surg Traumatol. 2018;28(7):1429\u201336.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"1857_CR4","doi-asserted-by":"crossref","unstructured":"Sandriesser, S., et al., Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis. Eur J Trauma Emerg Surg, 2020.","DOI":"10.1007\/s00068-020-01503-0"},{"issue":"1","key":"1857_CR5","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/s00113-016-0281-2","volume":"120","author":"L Claes","year":"2017","unstructured":"Claes L. Mechanobiology of fracture healing part 2: Relevance for internal fixation of fractures. Unfallchirurg. 2017;120(1):23\u201331.","journal-title":"Unfallchirurg"},{"key":"1857_CR6","first-page":"445","volume":"177","author":"O Goetze","year":"1933","unstructured":"Goetze O. Subcutane Drahtnaht bei Tibiaschr\u00e4gfrakturen. Arch f Klin Chir. 1933;177:445\u20139.","journal-title":"Arch f Klin Chir"},{"issue":"1","key":"1857_CR7","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1007\/s00264-012-1702-7","volume":"37","author":"M Lenz","year":"2013","unstructured":"Lenz M, et al. Biomechanical performance of different cable and wire cerclage configurations. Int Orthop. 2013;37(1):125\u201330.","journal-title":"Int Orthop"},{"issue":"4","key":"1857_CR8","first-page":"256","volume":"43","author":"CP Coles","year":"2000","unstructured":"Coles CP, Gross M. Closed tibial shaft fractures: management and treatment complications. A review of the prospective literature. Can J Surg. 2000;43(4):256\u201362.","journal-title":"Can J Surg"},{"issue":"6","key":"1857_CR9","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1111\/os.12575","volume":"11","author":"XK Liu","year":"2019","unstructured":"Liu XK, et al. Intramedullary nailing versus minimally invasive plate osteosynthesis for distal tibial fractures: a systematic review and meta-analysis. Orthop Surg. 2019;11(6):954\u201365.","journal-title":"Orthop Surg"},{"issue":"2","key":"1857_CR10","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1302\/0301-620X.71B2.2925753","volume":"71","author":"H Habernek","year":"1989","unstructured":"Habernek H, Walch G, Dengg C. Cerclage for torsional fractures of the tibia. J Bone Joint Surg Br. 1989;71(2):311\u20133.","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"1857_CR11","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1186\/s12891-020-3044-8","volume":"21","author":"L Wuarin","year":"2020","unstructured":"Wuarin L, et al. Clinical and radiographic predictors of acute compartment syndrome in the treatment of tibial shaft fractures: a retrospective cohort study. BMC Musculoskelet Disord. 2020;21(1):25.","journal-title":"BMC Musculoskelet Disord"},{"issue":"10","key":"1857_CR12","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1097\/BOT.0000000000000347","volume":"29","author":"MM McQueen","year":"2015","unstructured":"McQueen MM, et al. Predictors of compartment syndrome after tibial fracture. J Orthop Trauma. 2015;29(10):451\u20135.","journal-title":"J Orthop Trauma"},{"issue":"11","key":"1857_CR13","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1097\/BOT.0b013e31828f949c","volume":"27","author":"BJ Shore","year":"2013","unstructured":"Shore BJ, et al. Acute compartment syndrome in children and teenagers with tibial shaft fractures: incidence and multivariable risk factors. J Orthop Trauma. 2013;27(11):616\u201321.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"1857_CR14","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1097\/00005131-199509060-00004","volume":"9","author":"J Williams","year":"1995","unstructured":"Williams J, et al. Complications of nailing in closed tibial fractures. J Orthop Trauma. 1995;9(6):476\u201381.","journal-title":"J Orthop Trauma"},{"issue":"2","key":"1857_CR15","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1097\/00005131-199105020-00011","volume":"5","author":"KJ Koval","year":"1991","unstructured":"Koval KJ, et al. Complications of reamed intramedullary nailing of the tibia. J Orthop Trauma. 1991;5(2):184\u20139.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"1857_CR16","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s13018-018-1037-1","volume":"14","author":"L Hu","year":"2019","unstructured":"Hu L, et al. Comparison of intramedullary nailing and plate fixation in distal tibial fractures with metaphyseal damage: a meta-analysis of randomized controlled trials. J Orthop Surg Res. 2019;14(1):30.","journal-title":"J Orthop Surg Res"},{"issue":"6","key":"1857_CR17","doi-asserted-by":"publisher","first-page":"e208","DOI":"10.1097\/BOT.0000000000000256","volume":"29","author":"CA Collinge","year":"2015","unstructured":"Collinge CA, et al. Percutaneous clamping of spiral and oblique fractures of the tibial shaft: a safe and effective reduction aid during intramedullary nailing. J Orthop Trauma. 2015;29(6):e208\u201312.","journal-title":"J Orthop Trauma"},{"issue":"2","key":"1857_CR18","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1177\/230949900501300216","volume":"13","author":"D Inamdar","year":"2005","unstructured":"Inamdar D, et al. Pseudoaneurysm of anterior tibial artery following tibial nailing: a case report. J Orthop Surg (Hong Kong). 2005;13(2):186\u20139.","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"2","key":"1857_CR19","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1097\/00005131-199802000-00012","volume":"12","author":"C Roberts","year":"1998","unstructured":"Roberts C, et al. Vascular compromise and amputation after intramedullary nailing of a tibia fracture. J Orthop Trauma. 1998;12(2):136\u20138.","journal-title":"J Orthop Trauma"},{"key":"1857_CR20","doi-asserted-by":"crossref","unstructured":"Urban WP, Tornetta P (1995) Vascular compromise after intramedullary nailing of the tibia: a case report. J Trauma 38(5): 804\u20137","DOI":"10.1097\/00005373-199505000-00022"},{"issue":"10","key":"1857_CR21","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1097\/00005131-200311000-00003","volume":"17","author":"CM Bono","year":"2003","unstructured":"Bono CM, et al. Neurovascular and tendinous damage with placement of anteroposterior distal locking bolts in the tibia. J Orthop Trauma. 2003;17(10):677\u201382.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"1857_CR22","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/BF01628486","volume":"20","author":"NA Ebraheim","year":"1998","unstructured":"Ebraheim NA, et al. Anterior tibial artery and its actual projection on the lateral aspect of the tibia: a cadaveric study. Surg Radiol Anat. 1998;20(4):259\u201362.","journal-title":"Surg Radiol Anat"},{"key":"1857_CR23","unstructured":"Forch S et al. [Impairment of the blood supply by cerclages: myth or reality? : An overview of the experimental study situation]. Unfallchirurg, 2020."},{"issue":"2","key":"1857_CR24","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1002\/jor.1100090204","volume":"9","author":"BM Kirby","year":"1991","unstructured":"Kirby BM, Wilson JW. Effect of circumferential bands on cortical vascularity and viability. J Orthop Res. 1991;9(2):174\u20139.","journal-title":"J Orthop Res"},{"issue":"4","key":"1857_CR25","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1111\/j.1532-950X.1990.tb01180.x","volume":"19","author":"KA Nyrop","year":"1990","unstructured":"Nyrop KA, et al. Vascular response of the equine radius to cerclage devices. Vet Surg. 1990;19(4):249\u201353.","journal-title":"Vet Surg"},{"issue":"2","key":"1857_CR26","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1016\/j.injury.2012.10.016","volume":"44","author":"T Apivatthakakul","year":"2013","unstructured":"Apivatthakakul T, Phaliphot J, Leuvitoonvechkit S. Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study. Injury. 2013;44(2):168\u201374.","journal-title":"Injury"},{"key":"1857_CR27","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1097\/00003086-198310000-00045","volume":"179","author":"FW Rhinelander","year":"1983","unstructured":"Rhinelander FW, Stewart CL. Experimental fixation of femoral osteotomies by cerclage with nylon straps. Clin Orthop Relat Res. 1983;179:298\u2013307.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"1857_CR28","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1002\/jor.1100030403","volume":"3","author":"JW Wilson","year":"1985","unstructured":"Wilson JW, Rhinelander FW, Stewart CL. Microvascular and histologic effect of circumferential wire on appositional bone growth in immature dogs. J Orthop Res. 1985;3(4):412\u20137.","journal-title":"J Orthop Res"},{"issue":"10","key":"1857_CR29","doi-asserted-by":"publisher","first-page":"1467","DOI":"10.1007\/s00402-012-1572-x","volume":"132","author":"M Lenz","year":"2012","unstructured":"Lenz M, et al. Underneath the cerclage: an ex vivo study on the cerclage-bone interface mechanics. Arch Orthop Trauma Surg. 2012;132(10):1467\u201372.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"1857_CR30","first-page":"73","volume":"19","author":"H Habernek","year":"1989","unstructured":"Habernek H, et al. Percutaneous Goetze cerclage in torsion fractures of the tibia. A computer-assisted follow-up of 186 cases. Aktuelle Traumatol. 1989;19(2):73\u20136.","journal-title":"Aktuelle Traumatol"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-021-01857-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-021-01857-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-021-01857-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,8]],"date-time":"2022-08-08T14:06:54Z","timestamp":1659967614000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-021-01857-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,24]]},"references-count":30,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,8]]}},"alternative-id":["1857"],"URL":"https:\/\/doi.org\/10.1007\/s00068-021-01857-z","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,24]]},"assertion":[{"value":"7 August 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"F\u00f6rch S. declares that he has no conflict of interest. Reuter J. declares that he has no conflict of interest. von der Helm F. declares that she has no conflict of interest. Lisitano L. declares that he has no conflict of interest. Hartwig C. declares that he has no conflict of interest. Sandriesser S. declares that she has no conflict of interest. Nuber S. declares that he has no conflict of interest. Mayr E. declares that he has no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}