{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T23:35:16Z","timestamp":1768260916064,"version":"3.49.0"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T00:00:00Z","timestamp":1657065600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T00:00:00Z","timestamp":1657065600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"SZVK"},{"name":"Karel Doorman Fund"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>To gain insight into anatomical variations between sexes and different age groups in intraluminal distances and anatomical landmarks for correct insertion of resuscitative endovascular balloon occlusion of the aorta (REBOA) without fluoroscopic confirmation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials<\/jats:title>\n                <jats:p>All non-trauma patients receiving a computed tomography angiography (CT-A) scan of the aorta, iliac bifurcation and common femoral arteries from 2017 to 2019 were eligible for inclusion.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Central luminal line distances from the common femoral artery (CFA) to the aortic occlusion zones were measured and diameters of mid zone I, II and III were registered. Anatomical landmarks and correlations were assessed. A simulated REBOA placement was performed using the Joint Trauma System Clinical Practice Guideline (JTSCPG).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In total, 250 patients were included. Central luminal line (CLL) measurements from mid CFA to aortic bifurcation (<jats:italic>p<\/jats:italic>\u2009=\u20090.000), CLL measurements from CFA to mid zone I, II and III (<jats:italic>p<\/jats:italic>\u2009=\u20090.000) and zone I length (<jats:italic>p<\/jats:italic>\u2009=\u20090.000) showed longer lengths in men. The length of zone I and III (<jats:italic>p<\/jats:italic>\u2009=\u20090.000), CLL distance measurements from the right CFA to mid zone I (<jats:italic>p<\/jats:italic>\u2009=\u20090.000) and II (<jats:italic>p<\/jats:italic>\u2009=\u20090.013) and aortic diameters measured at mid zone I, II and III increased in higher age groups (<jats:italic>p<\/jats:italic>\u2009=\u20090.000). Using the JTSCPG guideline, successful deployment occurred in 95\/250 (38.0%) in zone III and 199\/250 (79.6%) in zone I. Correlation between mid-sternum and zone I is 100%. Small volume aortic occlusion balloons (AOB) have poor occlusion rates in zone I (0\u20132.8%) and III (4.4\u201334.4%).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Men and older age groups have longer CLL distances to zone I and III and introduction depths of AOB must be adjusted. The risk of not landing in zone III with standard introduction depths is high and balloon position for zone III REBOA is preferably confirmed using fluoroscopy. Mid-sternum can be used as a landmark in all patient groups for zone I. In older patients, balloon catheters with larger inflation volumes must be considered for aortic occlusion.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00068-022-02033-7","type":"journal-article","created":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T18:15:21Z","timestamp":1657131321000},"page":"4963-4969","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Comparison of aortic zones for endovascular bleeding control: age and sex differences"],"prefix":"10.1007","volume":"48","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1199-4042","authenticated-orcid":false,"given":"Boke Linso Sjirk Borger","family":"van der Burg","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suzanne","family":"Vrancken","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thijs Theodorus Cornelis Fransiscus","family":"van Dongen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tom","family":"Wamsteker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Todd","family":"Rasmussen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rigo","family":"Hoencamp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,6]]},"reference":[{"issue":"6","key":"2033_CR1","first-page":"1869","volume":"71","author":"A Stannard","year":"2011","unstructured":"Stannard A, Eliason JL, Rasmussen TE. Resuscitative endovascular balloon occlusion of the aorta (REBOA) as an adjunct for hemorrhagic shock. J Trauma. 2011;71(6):1869\u201372.","journal-title":"J Trauma"},{"issue":"8","key":"2033_CR2","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1056\/NEJMra1609326","volume":"380","author":"DR King","year":"2019","unstructured":"King DR. Initial care of the severely injured patient. N Engl J Med. 2019;380(8):763\u201370.","journal-title":"N Engl J Med"},{"issue":"1","key":"2033_CR3","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1097\/TA.0000000000000863","volume":"80","author":"M Chaudery","year":"2016","unstructured":"Chaudery M, Clark J, Morrison JJ, Wilson MH, Bew D, Darzi A. Can contrast-enhanced ultrasonography improve Zone III REBOA placement for prehospital care? J Trauma Acute Care Surg. 2016;80(1):89\u201394.","journal-title":"J Trauma Acute Care Surg"},{"issue":"6","key":"2033_CR4","doi-asserted-by":"publisher","first-page":"941","DOI":"10.1097\/TA.0000000000001043","volume":"80","author":"JN MacTaggart","year":"2016","unstructured":"MacTaggart JN, Poulson WE, Akhter M, Seas A, Thorson K, Phillips NY, Desyatova AS, Kamenskiy AV. Morphometric roadmaps to improve accurate device delivery for fluoroscopy-free resuscitative endovascular balloon occlusion of the aorta. J Trauma Acute Care Surg. 2016;80(6):941\u20136.","journal-title":"J Trauma Acute Care Surg"},{"issue":"3\u20134","key":"2033_CR5","doi-asserted-by":"publisher","first-page":"e285","DOI":"10.1093\/milmed\/usy187","volume":"184","author":"LE Wessels","year":"2019","unstructured":"Wessels LE, Wallace JD, Bowie J, Butler WJ, Spalding C, Krzyzaniak M. Radiofrequency Identification of the ER-REBOA: confirmation of placement without fluoroscopy. Mil Med. 2019;184(3\u20134):e285\u20139.","journal-title":"Mil Med"},{"key":"2033_CR6","unstructured":"Joint Trauma System Clinical Practice Guideline (JTS CPG). Resuscitative endovascular balloon occlusion of the aorta (REBOA) for hemorrhagic shock (CPG ID: 38). 2020."},{"issue":"1S Suppl 1","key":"2033_CR7","doi-asserted-by":"publisher","first-page":"S138","DOI":"10.1097\/TA.0000000000002247","volume":"87","author":"JL Eliason","year":"2019","unstructured":"Eliason JL, Derstine BA, Horbal SR, Wang NC, Holcombe SA, Chiu CH, Ross BE, Bromwell B, Morrison J, Wang SC. Computed tomography correlation of skeletal landmarks and vascular anatomy in civilian adult trauma patients: Implications for resuscitative endovascular balloon occlusion of the aorta. J Trauma Acute Care Surg. 2019;87(1S Suppl 1):S138\u201345.","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"2033_CR8","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/s00068-020-01382-5","volume":"47","author":"SM Vrancken","year":"2021","unstructured":"Vrancken SM, Borger van der Burg BLS, Vrancken PJEM, Kock GH, Rasmussen TE, Hoencamp R. A contemporary assessment of devices for resuscitative endovascular balloon occlusion of the aorta (REBOA) resource-specific options per level of care. Eur J Trauma Emerg Surg. 2021;47(1):57\u201369.","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"4","key":"2033_CR9","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1001\/jamasurg.2016.4757","volume":"152","author":"P Pezy","year":"2017","unstructured":"Pezy P, Flaris AN, Prat NJ, Cotton F, Lundberg PW, Caillot JL, David JS, Voiglio EJ. Fixed-distance model for balloon placement during fluoroscopy-free resuscitative endovascular balloon occlusion of the aorta in a civilian population. JAMA Surg. 2017;152(4):351\u20138.","journal-title":"JAMA Surg"},{"issue":"1","key":"2033_CR10","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/s13049-017-0411-z","volume":"25","author":"Y Okada","year":"2017","unstructured":"Okada Y, Narumiya H, Ishi W, Iiduka R. Anatomical landmarks for safely implementing resuscitative balloon occlusion of the aorta (REBOA) in zone 1 without fluoroscopy. Scand J Trauma Resusc Emerg Med. 2017;25(1):63.","journal-title":"Scand J Trauma Resusc Emerg Med"},{"issue":"6","key":"2033_CR11","doi-asserted-by":"publisher","first-page":"1617","DOI":"10.1016\/j.surg.2015.05.013","volume":"158","author":"A Kamenskiy","year":"2015","unstructured":"Kamenskiy A, Miserlis D, Adamson P, Adamson M, Knowles T, Neme J, Koutakis P, Phillips N, Pipinos I, MacTaggart J. Patient demographics and cardiovascular risk factors differentially influence geometric remodeling of the aorta compared with the peripheral arteries. Surgery. 2015;158(6):1617\u201327.","journal-title":"Surgery"},{"issue":"21","key":"2033_CR12","doi-asserted-by":"publisher","first-page":"1772","DOI":"10.1136\/heartjnl-2017-312866","volume":"104","author":"BP Adriaans","year":"2018","unstructured":"Adriaans BP, Heuts S, Gerretsen S, Cheriex EC, Vos R, Natour E, Maessen JG, Sardari Nia P, Crijns H, Wildberger JE, et al. Aortic elongation part I: the normal aortic ageing process. Heart. 2018;104(21):1772\u20137.","journal-title":"Heart"},{"issue":"1","key":"2033_CR13","doi-asserted-by":"publisher","first-page":"13410","DOI":"10.1038\/s41598-020-70364-9","volume":"10","author":"MH Olsen","year":"2020","unstructured":"Olsen MH, Thonghong T, S\u00f8ndergaard L, M\u00f8ller K. Standardized distances for placement of REBOA in patients with aortic stenosis. Sci Rep. 2020;10(1):13410.","journal-title":"Sci Rep"},{"issue":"3","key":"2033_CR14","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1097\/TA.0000000000001106","volume":"81","author":"M Linnebur","year":"2016","unstructured":"Linnebur M, Inaba K, Haltmeier T, Rasmussen TE, Smith J, Mendelsberg R, Grabo D, Demetriades D. Emergent non-image-guided resuscitative endovascular balloon occlusion of the aorta (REBOA) catheter placement: a cadaver-based study. J Trauma Acute Care Surg. 2016;81(3):453\u20137.","journal-title":"J Trauma Acute Care Surg"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-022-02033-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-022-02033-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-022-02033-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,30]],"date-time":"2022-11-30T18:32:53Z","timestamp":1669833173000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-022-02033-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,6]]},"references-count":14,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["2033"],"URL":"https:\/\/doi.org\/10.1007\/s00068-022-02033-7","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,6]]},"assertion":[{"value":"4 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"B.L.S. Borger van der Burg, S.M. Vrancken, T. Wamsteker, T.T.C.F van Dongen, T.E. Rasmussen and R. Hoencamp report no proprietary or commercial interest in any product mentioned or concept discussed in this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the Medical Ethical Committee of Alrijne Hospital, the Netherlands (NWMO 18.114rt.tk). It was deemed not necessary to obtain informed consent. Research did not involve human participants and\/or animals.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}