{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T17:59:43Z","timestamp":1790963983164,"version":"4.1.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,30]],"date-time":"2023-06-30T00:00:00Z","timestamp":1688083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,30]],"date-time":"2023-06-30T00:00:00Z","timestamp":1688083200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>A substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>\nIn three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>\nA total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5\u20139.5) to 0.9\u00a0mm (IQR 0.2\u20131.4), whereas the median step-off was reduced from 4.8 (IQR 4.1\u20135.3) to 1.3\u00a0mm (IQR 0.9\u20131.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0\u00a0mm (IQR: 2.8\u20133.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3\u00b0 (IQR: 2.5\u20135.1).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>This feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00068-023-02313-w","type":"journal-article","created":{"date-parts":[[2023,6,30]],"date-time":"2023-06-30T17:01:51Z","timestamp":1688144511000},"page":"11-19","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery"],"prefix":"10.1007","volume":"50","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0034-6816","authenticated-orcid":false,"given":"Nick","family":"Assink","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4161-3634","authenticated-orcid":false,"given":"Miriam G. E.","family":"Oldhoff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8920-8796","authenticated-orcid":false,"given":"Kaj","family":"ten Duis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8527-960X","authenticated-orcid":false,"given":"Joep","family":"Kraeima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1270-2742","authenticated-orcid":false,"given":"Job N.","family":"Doornberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4135-3246","authenticated-orcid":false,"given":"Max J. H.","family":"Witjes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2669-320X","authenticated-orcid":false,"given":"Jean-Paul P. M.","family":"de Vries","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6882-0054","authenticated-orcid":false,"given":"Anne M. L.","family":"Meesters","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9420-2732","authenticated-orcid":false,"given":"Frank F. A.","family":"IJpma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,6,30]]},"reference":[{"key":"2313_CR1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199307000-00011","author":"H Tscherne","year":"1993","unstructured":"Tscherne H, Lobenhoffer P. Tibial plateau fractures: Management and expected results. Clin Orthop Relat Res. 1993. https:\/\/doi.org\/10.1097\/00003086-199307000-00011.","journal-title":"Clin Orthop Relat Res"},{"key":"2313_CR2","doi-asserted-by":"publisher","DOI":"10.1302\/2058-5241.1.000031","author":"S Prat-Fabregat","year":"2016","unstructured":"Prat-Fabregat S, Camacho-Carrasco P. Treatment strategy for tibial plateau fractures: an update. EFORT Open Rev. 2016. https:\/\/doi.org\/10.1302\/2058-5241.1.000031.","journal-title":"EFORT Open Rev"},{"key":"2313_CR3","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1080\/10255842.2010.482044","volume":"14","author":"B Schmutz","year":"2011","unstructured":"Schmutz B, et al. Fit optimisation of a distal medial tibia plate. Comput Methods Biomech Biomed Engin. 2011;14:359\u201364.","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"2313_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-019-44092-8","volume":"9","author":"L Quintens","year":"2019","unstructured":"Quintens L, et al. Anatomical variation of the tibia\u2013a principal component analysis. Sci Rep. 2019;9:1\u201310.","journal-title":"Sci Rep"},{"issue":"461","key":"2313_CR5","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1097\/BLO.0b013e31809e6e45","volume":"1976\u20132007","author":"KS Goyal","year":"2007","unstructured":"Goyal KS, Skalak AS, Marcus RE, Vallier HA, Cooperman DR. AN ABJS BEST PAPER: analysis of anatomic periarticular tibial plate fit on normal adults. Clin Orthop Relat Res. 2007;1976\u20132007(461):245\u201357.","journal-title":"Clin Orthop Relat Res"},{"key":"2313_CR6","doi-asserted-by":"publisher","first-page":"S2","DOI":"10.1016\/S0020-1383(18)30294-8","volume":"49","author":"P Augat","year":"2018","unstructured":"Augat P, von R\u00fcden C. Evolution of fracture treatment with bone plates. Injury. 2018;49:S2\u20137.","journal-title":"Injury"},{"key":"2313_CR7","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1007\/s11999-011-2089-2","volume":"470","author":"M Mahfouz","year":"2012","unstructured":"Mahfouz M, Abdel Fatah EE, Bowers LS, Scuderi G. Three-dimensional morphology of the knee reveals ethnic differences. Clin Orthop Relat Res. 2012;470:172\u201385.","journal-title":"Clin Orthop Relat Res"},{"key":"2313_CR8","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000000735","author":"B Meulenkamp","year":"2017","unstructured":"Meulenkamp B, et al. Incidence, risk factors, and location of Articular malreductions of the Tibial Plateau. J Orthop Trauma. 2017. https:\/\/doi.org\/10.1097\/BOT.0000000000000735.","journal-title":"J Orthop Trauma"},{"key":"2313_CR9","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1097\/BOT.0000000000000762","volume":"31","author":"N Singleton","year":"2017","unstructured":"Singleton N, Sahakian V, Muir D. Outcome after tibial plateau fracture: how important is restoration of articular congruity? J Orthop Trauma. 2017;31:158\u201363.","journal-title":"J Orthop Trauma"},{"key":"2313_CR10","doi-asserted-by":"crossref","unstructured":"Barei, D. P. et al. Functional Outcomes of Severe Bicondylar Tibial Plateau Fractures Treated with Dual Inci-sions and Medial and Lateral Plates. JOURNAL OF BONE AND JOINT SURGERY http:\/\/Journals.lww.com\/jbjsjournal (2006).","DOI":"10.2106\/JBJS.E.00907"},{"key":"2313_CR11","doi-asserted-by":"publisher","first-page":"e2037519","DOI":"10.1001\/jamanetworkopen.2020.37519","volume":"4","author":"FFA Ijpma","year":"2021","unstructured":"Ijpma FFA, et al. Feasibility of imaging-based 3-dimensional models to design patient-specific osteosynthesis plates and drilling guides. JAMA Netw Open. 2021;4:e2037519.","journal-title":"JAMA Netw Open"},{"key":"2313_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2017.08.059","author":"BJ Merema","year":"2017","unstructured":"Merema BJ, et al. The design, production and clinical application of 3D patient-specific implants with drilling guides for acetabular surgery. Injury. 2017. https:\/\/doi.org\/10.1016\/j.injury.2017.08.059.","journal-title":"Injury"},{"key":"2313_CR13","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/S0940-9602(11)80346-8","volume":"174","author":"W Thiel","year":"1992","unstructured":"Thiel W. The preservation of the whole corpse with natural color. Ann Anat. 1992;174:185\u201395.","journal-title":"Ann Anat"},{"key":"2313_CR14","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-022-02139-y","author":"N Assink","year":"2022","unstructured":"Assink N, et al. 3D assessment of initial fracture displacement of tibial plateau fractures is predictive for risk on conversion to total knee arthroplasty at long-term follow-up. Eur J Trauma Emerg Surg. 2022. https:\/\/doi.org\/10.1007\/s00068-022-02139-y.","journal-title":"Eur J Trauma Emerg Surg"},{"key":"2313_CR15","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-50887-6","author":"N Assink","year":"2019","unstructured":"Assink N, et al. Quantitative 3D measurements of tibial plateau fractures. Sci Rep. 2019. https:\/\/doi.org\/10.1038\/s41598-019-50887-6.","journal-title":"Sci Rep"},{"key":"2313_CR16","doi-asserted-by":"crossref","unstructured":"Barei, D. P., Nork, S. E., Mills, W. J., Bradford Henley, M. & Benirschke, S. K. Complications Associated With Internal Fixation of High-Energy Bicondylar Tibial Plateau Fractures Utilizing a Two-Incision Technique. http:\/\/Journals.lww.com\/jorthotrauma (2004).","DOI":"10.1097\/00005131-200411000-00001"},{"key":"2313_CR17","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-021-01773-2","author":"N Assink","year":"2021","unstructured":"Assink N, et al. Does 3D-assisted surgery of tibial plateau fractures improve surgical and patient outcome? A systematic review of 1074 patients. Europ J Trauma Emergency Surg Preprint at. 2021. https:\/\/doi.org\/10.1007\/s00068-021-01773-2.","journal-title":"Europ J Trauma Emergency Surg Preprint at"},{"key":"2313_CR18","doi-asserted-by":"crossref","unstructured":"Teo, A. Q. A., Ng, D. Q. K., Peng, L. E. E. & O\u2019NEILL, G. K. Point-of-care 3D printing: a feasibility study of using 3D printing for orthopaedic trauma. Injury 52, 3286\u20133292 (2021).","DOI":"10.1016\/j.injury.2021.02.041"},{"key":"2313_CR19","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1016\/j.injury.2021.11.051","volume":"53","author":"AQA Teo","year":"2022","unstructured":"Teo AQA, Ng DQK, Ramruttun AK, O\u2019Neill GK. Standard versus customised locking plates for fixation of schatzker ii tibial plateau fractures. Injury. 2022;53:676\u201382.","journal-title":"Injury"},{"key":"2313_CR20","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1097\/BOT.0b013e31816b10ba","volume":"22","author":"B Schmutz","year":"2008","unstructured":"Schmutz B, Wullschleger ME, Kim H, Noser H, Sch\u00fctz MA. Fit assessment of anatomic plates for the distal medial tibia. J Orthop Trauma. 2008;22:258\u201363.","journal-title":"J Orthop Trauma"},{"key":"2313_CR21","doi-asserted-by":"publisher","DOI":"10.1007\/s13246-015-0330-0","author":"H Huang","year":"2015","unstructured":"Huang H, et al. Improved accuracy of 3D-printed navigational template during complicated tibial plateau fracture surgery. Australas Phys Eng Sci Med. 2015. https:\/\/doi.org\/10.1007\/s13246-015-0330-0.","journal-title":"Australas Phys Eng Sci Med"},{"key":"2313_CR22","doi-asserted-by":"publisher","first-page":"763","DOI":"10.3390\/jpm11080763","volume":"11","author":"AML Meesters","year":"2021","unstructured":"Meesters AML, et al. Accuracy of patient-specific drilling guides in acetabular fracture surgery: a human cadaver study. J Pers Med. 2021;11:763.","journal-title":"J Pers Med"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-023-02313-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-023-02313-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-023-02313-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,8]],"date-time":"2024-03-08T15:03:46Z","timestamp":1709910226000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-023-02313-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,30]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["2313"],"URL":"https:\/\/doi.org\/10.1007\/s00068-023-02313-w","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,30]]},"assertion":[{"value":"2 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The cadaver studies were performed at the Skills Center of the University Medical Centre Groningen. This study was performed in line with the principles of the Declaration of Helsinki. The body donors approved the scientific usage of their bodies for teaching and research purposes in their lifetime. An approval by an ethics committee was not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}