{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T04:08:58Z","timestamp":1793851738574,"version":"4.6.1"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2023,8,9]],"date-time":"2023-08-09T00:00:00Z","timestamp":1691539200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,8,9]],"date-time":"2023-08-09T00:00:00Z","timestamp":1691539200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100006447","name":"University of Zurich","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100006447","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background\/Purpose<\/jats:title>\n                <jats:p>The surgical fixation of a symphyseal diastasis in partially or fully unstable pelvic ring injuries is an important element when stabilizing the anterior pelvic ring. Currently, open reduction and internal fixation (ORIF) by means of plating represents the gold standard treatment. Advances in percutaneous fixation techniques have shown improvements in blood loss, surgery time, and scar length. Therefore, this approach should also be adopted for treatment of symphyseal injuries. The technique could be important since failure rates, following ORIF at the symphysis, remain unacceptably high. The aim of this biomechanical study was to assess a semi-rigid fixation technique for treatment of\u00a0such anterior pelvic ring injuries versus current gold standards of plate osteosynthesis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>An anterior pelvic ring injury type III APC according to the Young and Burgess classification was simulated in eighteen composite pelvises, assigned to three groups (<jats:italic>n<\/jats:italic>\u2009=\u20096) for fixation with either a single plate, two orthogonally positioned plates, or the semi-rigid technique using an endobutton suture implant. Biomechanical testing was performed in a simulated upright standing position under progressively increasing cyclic loading\u00a0at 2\u00a0Hz until failure or over 150,000\u00a0cycles. Relative movements between the bone segments were captured by motion tracking.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Initial quasi-static and dynamic stiffness, as well as dynamic stiffness after 100,000 cycles, was not significantly different among the fixation techniques (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.054).). The outcome measures for total displacement after 20,000, 40,000, 60,000, 80,000, and 100,000 cycles were associated with significantly higher values for the suture technique versus double plating (<jats:italic>p<\/jats:italic>\u2009=\u20090.025), without further significant differences among the techniques (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.349). Number of cycles to failure and load at failure were highest for double plating (150,000\u2009\u00b1\u20090\/100.0\u2009\u00b1\u20090.0 N), followed by single plating (132,282\u2009\u00b1\u200920,465\/91.1\u2009\u00b1\u200910.2 N), and the suture technique (116,088\u2009\u00b1\u200912,169\/83.0\u2009\u00b1\u20096.1 N), with significantly lower values in the latter compared to the former (<jats:italic>p<\/jats:italic>\u2009=\u20090.002)\u00a0and no\u00a0further significant differences among the techniques (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.329).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>From a biomechanical perspective, the semi-rigid technique for fixation of unstable\u00a0pubic symphysis injuries demonstrated promising results with moderate to inferior behaviour compared to standard plating techniques regarding stiffness, cycles to failure\u00a0and load at\u00a0failure. This knowledge could lay the foundation for realization of\u00a0further studies with larger sample sizes, focusing on the stabilization of the anterior pelvic ring.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00068-023-02333-6","type":"journal-article","created":{"date-parts":[[2023,8,9]],"date-time":"2023-08-09T05:01:21Z","timestamp":1691557281000},"page":"2569-2578","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Substitutional semi-rigid osteosynthesis technique for treatment of unstable pubic symphysis injuries: a biomechanical study"],"prefix":"10.1007","volume":"49","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9582-1810","authenticated-orcid":false,"given":"Till","family":"Berk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan","family":"Zderic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Varga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Schwarzenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karlyn","family":"Berk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niklas","family":"Gr\u00fcneweller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatjana","family":"Pastor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sascha","family":"Halvachizadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geoff","family":"Richards","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boyko","family":"Gueorguiev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans-Christoph","family":"Pape","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,8,9]]},"reference":[{"key":"2333_CR1","doi-asserted-by":"publisher","first-page":"944","DOI":"10.2106\/JBJS.15.00723","volume":"98","author":"FR Avilucea","year":"2016","unstructured":"Avilucea FR, Whiting PS, Mir H. Posterior fixation of APC-2 pelvic ring injuries decreases rates of anterior plate failure and malunion. JBJS. 2016;98:944\u201351.","journal-title":"JBJS"},{"key":"2333_CR2","first-page":"479","volume":"27","author":"SR Zhou","year":"1989","unstructured":"Zhou SR. Fracture-dislocation of pelvis in the adult female: clinical analysis of 105 cases. Zhonghua wai ke za zhi [Chin J Surg]. 1989;27:479\u201381.","journal-title":"Zhonghua wai ke za zhi [Chin J Surg]"},{"key":"2333_CR3","unstructured":"Kellam J, Mayo K (2003) Pelvic ring disruption. Pelvic fractures. Skeletal Trauma 3rd Ed Philadelphia, PA: WB Saunders 1063"},{"key":"2333_CR4","unstructured":"Tile M, Helfet DL, Kellam JF, Vrahas M (1995) Fractures of the pelvis and acetabulum. Williams & Wilkins Baltimore."},{"key":"2333_CR5","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1002\/jor.1100090212","volume":"9","author":"GW Stocks","year":"1991","unstructured":"Stocks GW, Gabel GT, Noble PC, Hanson GW, Tullos HS. Anterior and posterior internal fixation of vertical shear fractures of the pelvis. J Orthop Res. 1991;9:237\u201345.","journal-title":"J Orthop Res"},{"key":"2333_CR6","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1097\/00005373-198806000-00016","volume":"28","author":"LX Webb","year":"1988","unstructured":"Webb LX, Gristina AG, Wilson JR, Rhyne AL, Meredith JH, Hansen S Jr. Two-hole plate fixation for traumatic symphysis pubis diastasis. J Trauma. 1988;28:813\u20137.","journal-title":"J Trauma"},{"key":"2333_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-015-0272-y","volume":"10","author":"K-H Yu","year":"2015","unstructured":"Yu K-H, Hong J-J, Guo X-S, Zhou D-S. Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience. J Orthop Surg Res. 2015;10:1\u20138.","journal-title":"J Orthop Surg Res"},{"key":"2333_CR8","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1097\/BOT.0b013e318162ab6e","volume":"22","author":"AJ Starr","year":"2008","unstructured":"Starr AJ, Nakatani T, Reinert CM, Cederberg K. Superior pubic ramus fractures fixed with percutaneous screws: what predicts fixation failure? J Orthop Trauma. 2008;22:81\u20137.","journal-title":"J Orthop Trauma"},{"key":"2333_CR9","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1097\/00003086-200006000-00004","volume":"375","author":"MC Routt Jr","year":"2000","unstructured":"Routt MC Jr, Nork SE, Mills WJ. Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res. 2000;375:15\u201329.","journal-title":"Clin Orthop Relat Res"},{"key":"2333_CR10","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1097\/00005131-199711000-00007","volume":"11","author":"MC Routt Jr","year":"1997","unstructured":"Routt MC Jr, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma. 1997;11:584\u20139.","journal-title":"J Orthop Trauma"},{"key":"2333_CR11","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1097\/BOT.0b013e31817e49ee","volume":"22","author":"HC Sagi","year":"2008","unstructured":"Sagi HC, Papp S. Comparative radiographic and clinical outcome of two-hole and multi-hole symphyseal plating. J Orthop Trauma. 2008;22:373\u20138. https:\/\/doi.org\/10.1097\/BOT.0b013e31817e49ee.","journal-title":"J Orthop Trauma"},{"key":"2333_CR12","doi-asserted-by":"publisher","first-page":"2148","DOI":"10.1007\/s11999-012-2340-5","volume":"470","author":"C Collinge","year":"2012","unstructured":"Collinge C, Archdeacon MT, Dulaney-Cripe E, Moed BR. Radiographic changes of implant failure after plating for pubic symphysis diastasis: an underappreciated reality? Clin Orthop Relat Res. 2012;470:2148\u201353. https:\/\/doi.org\/10.1007\/s11999-012-2340-5.","journal-title":"Clin Orthop Relat Res"},{"key":"2333_CR13","doi-asserted-by":"publisher","first-page":"1630","DOI":"10.2106\/jbjs.H.00477","volume":"91A","author":"CA Collinge","year":"2009","unstructured":"Collinge CA, Archdeacon MT, LeBus G. Saddle-horn injury of the pelvis the injury, its outcomes, and associated male sexual dysfunction. J Bone Joint Surg Am. 2009;91A:1630\u20136. https:\/\/doi.org\/10.2106\/jbjs.H.00477.","journal-title":"J Bone Joint Surg Am"},{"key":"2333_CR14","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1007\/s00113-019-0659-z","volume":"122","author":"J Wilke","year":"2019","unstructured":"Wilke J, Pennig D. Percutaneous stabilization of the anterior pelvic ring in osteoporotic fractures. Unfallchirurg. 2019;122:612\u20137.","journal-title":"Unfallchirurg"},{"key":"2333_CR15","first-page":"122","volume":"89","author":"JC Coetzee","year":"2007","unstructured":"Coetzee JC, Ly TVJJ. Treatment of primarily ligamentous Lisfranc joint injuries: primary arthrodesis compared with open reduction and internal fixation: surgical technique. JBJS. 2007;89:122\u20137.","journal-title":"JBJS"},{"key":"2333_CR16","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1097\/00005373-199007000-00015","volume":"30","author":"AR Burgess","year":"1990","unstructured":"Burgess AR, Eastridge BJ, Young JW, Ellison TS, Ellison PS Jr, Poka A, Bathon GH, Brumback RJ. Pelvic ring disruptions: effective classification system and treatment protocols. J Trauma Acute Care. 1990;30:848\u201356.","journal-title":"J Trauma Acute Care"},{"key":"2333_CR17","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1136\/bjsports-2016-096677","volume":"51","author":"M Nambiar","year":"2017","unstructured":"Nambiar M, West LR, Bingham R. AO surgery reference: a comprehensive guide for management of fractures. Br J Sports Med. 2017;51:545\u20136.","journal-title":"Br J Sports Med"},{"key":"2333_CR18","doi-asserted-by":"publisher","first-page":"1485","DOI":"10.1002\/jor.23401","volume":"35","author":"N Gr\u00fcneweller","year":"2017","unstructured":"Gr\u00fcneweller N, Raschke MJ, Zderic I, Widmer D, W\u00e4hnert D, Gueorguiev B, Richards RG, Fuchs T, Windolf M. Biomechanical comparison of augmented versus non-augmented sacroiliac screws in a novel hemi-pelvis test model. J Orthop Res. 2017;35:1485\u201393.","journal-title":"J Orthop Res"},{"key":"2333_CR19","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/s0021-9290(01)00040-9","volume":"34","author":"G Bergmann","year":"2001","unstructured":"Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, Duda GN. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859\u201371. https:\/\/doi.org\/10.1016\/s0021-9290(01)00040-9.","journal-title":"J Biomech"},{"key":"2333_CR20","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1097\/BOT.0b013e3182163345","volume":"25","author":"B Gueorguiev","year":"2011","unstructured":"Gueorguiev B, Ockert B, Schwieger K, W\u00e4hnert D, Lawson-Smith M, Windolf M, Stoffel K. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study. J Orthop Trauma. 2011;25:340\u20136.","journal-title":"J Orthop Trauma"},{"key":"2333_CR21","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.clinbiomech.2008.09.005","volume":"24","author":"M Windolf","year":"2009","unstructured":"Windolf M, Muths R, Braunstein V, Gueorguiev B, H\u00e4nni M, Schwieger K. Quantification of cancellous bone-compaction due to DHS\u00ae Blade insertion and influence upon cut-out resistance. Clin Biomech. 2009;24:53\u20138.","journal-title":"Clin Biomech"},{"key":"2333_CR22","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1097\/00005131-199806000-00019","volume":"12","author":"A Meiner","year":"1998","unstructured":"Meiner A, Fell M, Wilk R, Boenick U, Rahmanzadeh R. Comparison of different methods of internal fixation of symphyseal disruptions under multidirectional dynamic conditions: an experimental analysis simulating gait conditions. J Orthop Trauma. 1998;12:371.","journal-title":"J Orthop Trauma"},{"key":"2333_CR23","doi-asserted-by":"publisher","first-page":"203","DOI":"10.3109\/17453678408992338","volume":"55","author":"G Walheim","year":"1984","unstructured":"Walheim G, Olerud S, Ribbe T. Mobility of the pubic symphysis - measurements by an electromechanical method. Acta Orthop Scand. 1984;55:203\u20138. https:\/\/doi.org\/10.3109\/17453678408992338.","journal-title":"Acta Orthop Scand"},{"key":"2333_CR24","first-page":"317","volume":"51","author":"IS Grewal","year":"2020","unstructured":"Grewal IS, Starr AJ. What\u2019s new in percutaneous pelvis fracture surgery? Orthopedic Clinics. 2020;51:317\u201324.","journal-title":"Orthopedic Clinics"},{"key":"2333_CR25","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1016\/j.injury.2016.05.019","volume":"47","author":"JG Eastman","year":"2016","unstructured":"Eastman JG, Krieg JC, Routt MLC. Early failure of symphysis pubis plating. Injury-Int J Care Inj. 2016;47:1707\u201312. https:\/\/doi.org\/10.1016\/j.injury.2016.05.019.","journal-title":"Injury-Int J Care Inj"},{"key":"2333_CR26","doi-asserted-by":"publisher","first-page":"E71","DOI":"10.1097\/BOT.0b013e31822c8396","volume":"26","author":"BR Moed","year":"2012","unstructured":"Moed BR, Grimshaw CS, Segina DN. Failure of locked design-specific plate fixation of the pubic symphysis: a report of six cases. J Orthop Trauma. 2012;26:E71\u20135. https:\/\/doi.org\/10.1097\/BOT.0b013e31822c8396.","journal-title":"J Orthop Trauma"},{"key":"2333_CR27","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1007\/s00113-020-00804-8","volume":"123","author":"MC Jordan","year":"2020","unstructured":"Jordan MC, Jackie V, Scheidt S, Eden L, Gilbert F, Heintel TM, Jansen H, Meffert RH. Outcome after plate stabilization of symphyseal diastasis. Unfallchirurg. 2020;123:870\u20138. https:\/\/doi.org\/10.1007\/s00113-020-00804-8.","journal-title":"Unfallchirurg"},{"key":"2333_CR28","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1097\/00003086-199608000-00018","volume":"329","author":"P Tornetta","year":"1996","unstructured":"Tornetta P, Dickson K, Matta JM. Outcome of rotationally unstable pelvic ring injuries treated operatively. Clin Orthop Related Res. 1996;329:147\u201351.","journal-title":"Clin Orthop Related Res"},{"issue":"49","key":"2333_CR29","doi-asserted-by":"publisher","first-page":"e2207","DOI":"10.1097\/MD.0000000000002207","volume":"94","author":"F Yao","year":"2015","unstructured":"Yao F, He Y, Qian H, Zhou D, Li Q. Comparison of biomechanical characteristics and pelvic ring stability using different fixation methods to treat pubic symphysis diastasis: a finite element study. Medicine. 2015;94(49):e2207.","journal-title":"Medicine"},{"key":"2333_CR30","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-019-1509-y","author":"CA Becker","year":"2019","unstructured":"Becker CA, Kussmaul AC, Suero EM, Regauer M, Woiczinski M, Braun C, Flatz W, Pieske O, Kammerlander C, Boecker W, Greiner A. Tape suture for stabilization of incomplete posterior pelvic ring fractures-biomechanical analysis of a new minimally invasive treatment for incomplete lateral compression pelvic ring fractures. J Orthop Surg Res. 2019. https:\/\/doi.org\/10.1186\/s13018-019-1509-y.","journal-title":"J Orthop Surg Res"},{"key":"2333_CR31","first-page":"415","volume":"99","author":"A Meissner","year":"1996","unstructured":"Meissner A, Fell M, Wilk R, Boenick U, Rahmanzadeh R. Biomechanics of the pubic symphysis. Which forces lead to mobility of the symphysis in physiological conditions? Unfallchirurg. 1996;99:415\u201321.","journal-title":"Unfallchirurg"},{"key":"2333_CR32","doi-asserted-by":"publisher","first-page":"1993","DOI":"10.1016\/j.injury.2018.09.032","volume":"49","author":"EM Kiskaddon","year":"2018","unstructured":"Kiskaddon EM, Wright A, Meeks BD, Froehle AW, Gould GC, Lubitz MG, Prayson MJ, Horne BR. A biomechanical cadaver comparison of suture button fixation to plate fixation for pubic symphysis diastasis. Injury-Int J Care Inj. 2018;49:1993\u20138. https:\/\/doi.org\/10.1016\/j.injury.2018.09.032.","journal-title":"Injury-Int J Care Inj"},{"key":"2333_CR33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-016-0397-7","volume":"11","author":"Y Feng","year":"2016","unstructured":"Feng Y, Hong J, Guo X, Lin C, Ling W, Zhang L, Wang G. Percutaneous fixation of traumatic pubic symphysis diastasis using a TightRope and external fixator versus using a cannulated screw. J Orthop Surg Res. 2016;11:1\u20137.","journal-title":"J Orthop Surg Res"},{"key":"2333_CR34","doi-asserted-by":"publisher","first-page":"2235","DOI":"10.1007\/s00402-021-03968-z","volume":"142","author":"A Cavalcanti Ku\u00dfmaul","year":"2022","unstructured":"Cavalcanti Ku\u00dfmaul A, Schwaabe F, Kistler M, Gennen C, Andre\u00df S, Becker CA, B\u00f6cker W, Greiner A. Novel minimally invasive tape suture osteosynthesis for instabilities of the pubic symphysis: a biomechanical study. Arch Orthop Traum Su. 2022;142:2235\u201343.","journal-title":"Arch Orthop Traum Su"},{"key":"2333_CR35","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1007\/s00402-007-0429-1","volume":"128","author":"PV Giannoudis","year":"2008","unstructured":"Giannoudis PV, Chalidis BE, Roberts CS. Internal fixation of traumatic diastasis of pubic symphysis: is plate removal essential? Arch Orthop Traum Su. 2008;128:325\u201331. https:\/\/doi.org\/10.1007\/s00402-007-0429-1.","journal-title":"Arch Orthop Traum Su"},{"key":"2333_CR36","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1007\/s00068-012-0224-8","volume":"38","author":"P Rommens","year":"2012","unstructured":"Rommens P, Wagner D, Hofmann A. Surgical management of osteoporotic pelvic fractures: a new challenge. Eur J Trauma Emerg S. 2012;38:499\u2013509.","journal-title":"Eur J Trauma Emerg S"},{"key":"2333_CR37","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00776-014-0653-9","volume":"20","author":"PM Rommens","year":"2015","unstructured":"Rommens PM, Ossendorf C, Pairon P, Dietz S-O, Wagner D, Hofmann A. Clinical pathways for fragility fractures of the pelvic ring: personal experience and review of the literature. J Orthop Sci. 2015;20:1\u201311.","journal-title":"J Orthop Sci"},{"key":"2333_CR38","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1097\/00005131-200309000-00003","volume":"17","author":"S Kabak","year":"2003","unstructured":"Kabak S, Halici M, Tuncel M, Avsarogullar L, Baktir A, Basturk M. Functional outcome of open reduction and internal fixation for completely unstable pelvic ring fractures (type C): a report of 40 cases. J Orthop Trauma. 2003;17:555\u201362.","journal-title":"J Orthop Trauma"},{"key":"2333_CR39","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1007\/s10439-009-9887-7","volume":"38","author":"MP Gardner","year":"2010","unstructured":"Gardner MP, Chong A, Pollock AG, Wooley PH. Mechanical evaluation of large-size fourth-generation composite femur and tibia models. Ann Biomed Eng. 2010;38:613\u201320.","journal-title":"Ann Biomed Eng"},{"key":"2333_CR40","doi-asserted-by":"publisher","first-page":"3282","DOI":"10.1016\/j.jbiomech.2008.08.013","volume":"41","author":"AD Heiner","year":"2008","unstructured":"Heiner AD. Structural properties of fourth-generation composite femurs and tibias. J Biomech. 2008;41:3282\u20134.","journal-title":"J Biomech"},{"key":"2333_CR41","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1243\/09544119JEIM409","volume":"222","author":"R Zdero","year":"2008","unstructured":"Zdero R, Olsen M, Bougherara H, Schemitsch E. Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis. Proc Inst Mech Eng [H]. 2008;222:1175\u201383.","journal-title":"Proc Inst Mech Eng [H]"},{"key":"2333_CR42","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1007\/s00264-015-3007-0","volume":"40","author":"G Camino Willhuber","year":"2016","unstructured":"Camino Willhuber G, Zderic I, Gras F, Wahl D, Sancineto C, Barla J, Windolf M, Richards RG, Gueorguiev B. Analysis of sacro-iliac joint screw fixation: does quality of reduction and screw orientation influence joint stability? a biomechanical study. Int Orthop. 2016;40:1537\u201343.","journal-title":"Int Orthop"},{"key":"2333_CR43","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1097\/BOT.0b013e318126bb8e","volume":"21","author":"MJ Gardner","year":"2007","unstructured":"Gardner MJ, Kendoff D, Ostermeier S, Citak M, H\u00fcfner T, Krettek C, Nork SE. Sacroiliac joint compression using an anterior pelvic compressor: a mechanical study in synthetic bone. J Orthop Trauma. 2007;21:435\u201341.","journal-title":"J Orthop Trauma"},{"key":"2333_CR44","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1097\/00005131-200308000-00002","volume":"17","author":"K Yinger","year":"2003","unstructured":"Yinger K, Scalise J, Olson SA, Bay BK, Finkemeier CG. Biomechanical comparison of posterior pelvic ring fixation. J Orthop Trauma. 2003;17:481\u20137. https:\/\/doi.org\/10.1097\/00005131-200308000-00002.","journal-title":"J Orthop Trauma"},{"key":"2333_CR45","doi-asserted-by":"publisher","first-page":"411","DOI":"10.3944\/AOTT.2013.2840","volume":"47","author":"O Sahin","year":"2013","unstructured":"Sahin O, Demirors H, Akgun R, Tuncay I. Internal fixation of bilateral sacroiliac dislocation with transiliac locked plate: a biomechanical study on pelvic models. Acta Orthop Traumatol Turc. 2013;47:411\u20136.","journal-title":"Acta Orthop Traumatol Turc"},{"key":"2333_CR46","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1097\/00005131-200403000-00002","volume":"18","author":"H Sagi","year":"2004","unstructured":"Sagi H, Ordway N, DiPasquale T. Biomechanical analysis of fixation for vertically unstable sacroiliac dislocations with iliosacral screws and symphyseal plating. J Orthop Trauma. 2004;18:138\u201343.","journal-title":"J Orthop Trauma"},{"key":"2333_CR47","unstructured":"Synbone A Statement artificial vs. human bones, 2007. In."},{"key":"2333_CR48","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1097\/01.Ta.0000158515.58494.11","volume":"58","author":"CMA van Zwienen","year":"2005","unstructured":"van Zwienen CMA, van den Bosch EW, van Dijke GAH, van Vugt AB. Cyclic loading of sacroiliac screws in tile C pelvic fractures. J Trauma-Inj Infect Crit Care. 2005;58:1029\u201334. https:\/\/doi.org\/10.1097\/01.Ta.0000158515.58494.11.","journal-title":"J Trauma-Inj Infect Crit Care"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-023-02333-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-023-02333-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-023-02333-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,18]],"date-time":"2023-12-18T17:05:42Z","timestamp":1702919142000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-023-02333-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,9]]},"references-count":48,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023,12]]}},"alternative-id":["2333"],"URL":"https:\/\/doi.org\/10.1007\/s00068-023-02333-6","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,9]]},"assertion":[{"value":"14 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"None of the authors has any conflicts of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All methods were carried out in accordance with relevant guidelines and regulations. This study was performed in line with the principles of the Declaration of Helsinki.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}]}}