{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T10:10:50Z","timestamp":1793095850725,"version":"4.5.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T00:00:00Z","timestamp":1749600000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T00:00:00Z","timestamp":1749600000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100011852","name":"Paracelsus Medical University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100011852","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Supplemental cerclage wiring at the distal tibia has shown to improve the mechanical stabilization of the fracture. However, its clinical use remains controversial partly because of concerns about implant loosening as well as frictional or constrictive interference between the cerclage and cortical surface. The aim of this study was to investigate in a distal tibia fracture model possible loosening of the cerclage and interference with the bone surface.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Fourteen distal tibia oblique fractures (AO\/OTA 42-A2) in seven human and synthetic bone samples, respectively were treated by plate osteosynthesis with supplemental cerclage wiring. The samples were subjected to 50,000 load cycles under combined axial and torsional loads. Angular and axial displacement were continuously monitored to identify possible cerclage loosening cerclage. Potential incision of the cerclage was inspected visually and on CT scans.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Angular displacement was significantly influenced by the bone material (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009\u2264\u20090.001) and type of osteosynthesis (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009\u2264\u20090.001), while axial displacement was only influenced by the type of osteosynthesis (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009\u2264\u20090.001). Lowest displacements were found in samples with plate and cable cerclage. Cerclage stability was maintained throughout the entire test period of 50,000 load cycles for human and synthetic samples. CT images revealed notches from the cerclage clamping mechanism but no incisions of the cable itself.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In an oblique distal tibia fracture model, loosening of the cable cerclage was not detected. Full weight-bearing cyclic loads resulted in slight imprints of the cerclage crimp in both, human and synthetic samples. Following the surgical guidelines for careful cerclage installation, a supplemental cable cerclage has the potential to significantly increase the construct stability.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00068-025-02894-8","type":"journal-article","created":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T09:00:34Z","timestamp":1749632434000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical evaluation of cerclage wiring in plated tibia fractures using human and synthetic specimens"],"prefix":"10.1007","volume":"51","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9439-0016","authenticated-orcid":false,"given":"Sabrina","family":"Sandriesser","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"F\u00f6rch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Reuter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Kern","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9537-9070","authenticated-orcid":false,"given":"Marianne","family":"Hollensteiner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edgar","family":"Mayr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4805-2128","authenticated-orcid":false,"given":"Peter","family":"Augat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,11]]},"reference":[{"issue":"6","key":"2894_CR1","doi-asserted-by":"publisher","first-page":"389","DOI":"10.55095\/achot2015\/065","volume":"82","author":"SM Perren","year":"2015","unstructured":"Perren SM, Fernandez Dell\u2019oca A, Regazzoni P. Fracture fixation using cerclage, research applied to surgery. Acta Chir Orthop Traumatol Cech. 2015;82(6):389\u201397.","journal-title":"Acta Chir Orthop Traumatol Cech"},{"issue":"3","key":"2894_CR2","doi-asserted-by":"publisher","first-page":"190","DOI":"10.55095\/achot2011\/031","volume":"78","author":"SM Perren","year":"2011","unstructured":"Perren SM, Fernandez Dell\u2019Oca A, Lenz M, Windolf M. Cerclage, evolution and potential of a Cinderella technology. An overview with reference to periprosthetic fractures. Acta Chir Orthop Traumatol Cech. 2011;78(3):190\u20139.","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"2894_CR3","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-020-03586-1","author":"C Bliemel","year":"2020","unstructured":"Bliemel C, Anrich D, Knauf T, Oberkircher L, Eschbach D, Klasan A, et al. More than a Reposition tool: additional wire cerclage leads to increased load to failure in plate osteosynthesis for Supracondylar femoral shaft fractures. Arch Orthop Trauma Surg. 2020. https:\/\/doi.org\/10.1007\/s00402-020-03586-1.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"4","key":"2894_CR4","doi-asserted-by":"publisher","first-page":"3081","DOI":"10.1007\/s00068-021-01847-1","volume":"48","author":"F von der Helm","year":"2022","unstructured":"von der Helm F, Fenwick A, Reuter J, Adolf-Lisitano L, Mayr E, Forch S. New ways of treatment of fractures of the humeral shaft: does the combination of intramedullary nail osteosynthesis and cerclage improve the healing process? Eur J Trauma Emerg Surg. 2022;48(4):3081\u20137. https:\/\/doi.org\/10.1007\/s00068-021-01847-1.","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"4","key":"2894_CR5","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1007\/s00590-022-03240-z","volume":"33","author":"AT Hantouly","year":"2023","unstructured":"Hantouly AT, Salameh M, Toubasi AA, Salman LA, Alzobi O, Ahmed AF, et al. The role of cerclage wiring in the management of subtrochanteric and reverse oblique intertrochanteric fractures: a meta-analysis of comparative studies. Eur J Orthop Surg Traumatol. 2023;33(4):739\u201349. https:\/\/doi.org\/10.1007\/s00590-022-03240-z.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"6","key":"2894_CR6","doi-asserted-by":"publisher","first-page":"1011","DOI":"10.1016\/S0736-0266(03)00098-6","volume":"21","author":"P Augat","year":"2003","unstructured":"Augat P, Burger J, Schorlemmer S, Henke T, Peraus M, Claes L. Shear movement at the fracture site delays healing in a diaphyseal fracture model. J Orthop Res. 2003;21(6):1011\u20137.","journal-title":"J Orthop Res"},{"issue":"8","key":"2894_CR7","doi-asserted-by":"publisher","first-page":"e0202702","DOI":"10.1371\/journal.pone.0202702","volume":"13","author":"L Claes","year":"2018","unstructured":"Claes L, Meyers N, Schulke J, Reitmaier S, Klose S, Ignatius A. The mode of interfragmentary movement affects bone formation and revascularization after callus distraction. PLoS ONE. 2018;13(8):e0202702.","journal-title":"PLoS ONE"},{"key":"2894_CR8","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-020-01503-0","author":"S Sandriesser","year":"2020","unstructured":"Sandriesser S, F\u00f6rch S, Mayr E, Schr\u00f6dl F, von R\u00fcden C, Augat P. Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a Biomechanical analysis. Eur J Trauma Emerg Surg. 2020. https:\/\/doi.org\/10.1007\/s00068-020-01503-0.","journal-title":"Eur J Trauma Emerg Surg"},{"key":"2894_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2021.03.040","author":"S F\u00f6rch","year":"2021","unstructured":"F\u00f6rch S, Sandriesser S, Mayr E, Schr\u00f6dl F, von R\u00fcden C, Augat P. Biomechanical comparison of different cerclage types in addition to an angle stable plate osteosynthesis of distal tibial fractures. Injury. 2021. https:\/\/doi.org\/10.1016\/j.injury.2021.03.040.","journal-title":"Injury"},{"key":"2894_CR10","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12051770","author":"S F\u00f6rch","year":"2023","unstructured":"F\u00f6rch S, Sandriesser S, von R\u00fcden C, Mayr E, Augat P. Cerclage wiring improves Biomechanical stability in distal tibia spiral fractures treated by intramedullary nailing. J Clin Med. 2023. https:\/\/doi.org\/10.3390\/jcm12051770.","journal-title":"J Clin Med"},{"issue":"4","key":"2894_CR11","doi-asserted-by":"publisher","first-page":"3115","DOI":"10.1007\/s00068-021-01857-z","volume":"48","author":"S F\u00f6rch","year":"2021","unstructured":"F\u00f6rch S, Reuter J, von der Helm F, Lisitano L, Hartwig C, Sandriesser S, et al. A minimally invasive cerclage of the tibia in a modified Goetze technique: operative technique and first clinical results. Eur J Trauma Emerg Surg. 2021;48(4):3115\u201322. https:\/\/doi.org\/10.1007\/s00068-021-01857-z.","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"3","key":"2894_CR12","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1177\/1602400319","volume":"24","author":"O Karakoyun","year":"2016","unstructured":"Karakoyun O, Sahin E, Erol MF, Kariksiz M, Kucukkaya M. Effect of cable cerclage on regional blood circulation in rabbits: a scintigraphic study. J Orthop Surg (Hong Kong). 2016;24(3):367\u20139. https:\/\/doi.org\/10.1177\/1602400319.","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"3","key":"2894_CR13","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1097\/00005373-199709000-00023","volume":"43","author":"MJ van Steijn","year":"1997","unstructured":"van Steijn MJ, Verhaar JA. Osteonecrosis caused by percutaneous cerclage wiring of a tibial fracture: case report. J Trauma. 1997;43(3):521\u20132. https:\/\/doi.org\/10.1097\/00005373-199709000-00023.","journal-title":"J Trauma"},{"issue":"5","key":"2894_CR14","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1007\/s00264-011-1238-2","volume":"35","author":"O Cebesoy","year":"2011","unstructured":"Cebesoy O, Subasi M, Isik M. Cerclage cable in fracture: frustration or necessity? Int Orthop. 2011;35(5):783\u20134. https:\/\/doi.org\/10.1007\/s00264-011-1238-2.","journal-title":"Int Orthop"},{"key":"2894_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/s00113-020-00847-x","author":"S F\u00f6rch","year":"2020","unstructured":"F\u00f6rch S, Sandriesser S, Fenwick A, Mayr E. Impairment of the blood supply by cerclages: myth or reality? An overview of the experimental study situation. Unfallchirurg. 2020. https:\/\/doi.org\/10.1007\/s00113-020-00847-x.","journal-title":"Unfallchirurg"},{"issue":"10","key":"2894_CR16","doi-asserted-by":"publisher","first-page":"1467","DOI":"10.1007\/s00402-012-1572-x","volume":"132","author":"M Lenz","year":"2012","unstructured":"Lenz M, Perren SM, Gueorguiev B, Richards RG, Krause F, Fernandez Dell\u2019Oca A, et al. Underneath the cerclage: an ex vivo study on the cerclage-bone interface mechanics. Arch Orthop Trauma Surg. 2012;132(10):1467\u201372.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"2894_CR17","doi-asserted-by":"publisher","first-page":"86","DOI":"10.5435\/00124635-201202000-00004","volume":"20","author":"MJ Gardner","year":"2012","unstructured":"Gardner MJ, Silva MJ, Krieg JC. Biomechanical testing of fracture fixation constructs: variability, validity, and clinical applicability. J Am Acad Orthop Surg. 2012;20(2):86\u201393.","journal-title":"J Am Acad Orthop Surg"},{"key":"2894_CR18","doi-asserted-by":"publisher","first-page":"104405","DOI":"10.1016\/j.jmbbm.2021.104405","volume":"117","author":"M Hollensteiner","year":"2021","unstructured":"Hollensteiner M, Sandriesser S, Hackl S, Augat P. Custom-made polyurethane-based synthetic bones mimic screw cut-through of intramedullary nails in human long bones. J Mech Behav Biomed Mater. 2021;117:104405. https:\/\/doi.org\/10.1016\/j.jmbbm.2021.104405.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"11","key":"2894_CR19","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1302\/0301-620X.98B11.BJJ-2016-0194.R1","volume":"98\u2013B","author":"PA Toogood","year":"2016","unstructured":"Toogood PA, Abdel MP, Spear JA, Cook SM, Cook DJ, Taunton MJ. The monitoring of activity at home after total hip arthroplasty. Bone Joint J. 2016;98\u2013B(11):1450\u20134. https:\/\/doi.org\/10.1302\/0301-620X.98B11.BJJ-2016-0194.R1.","journal-title":"Bone Joint J"},{"issue":"9","key":"2894_CR20","doi-asserted-by":"publisher","first-page":"1509","DOI":"10.1016\/j.arth.2013.03.014","volume":"28","author":"J Menard Jr","year":"2013","unstructured":"Menard J Jr., Emard M, Canet F, Brailovski V, Petit Y, Laflamme GY. Initial tension loss in cerclage cables. J Arthroplasty. 2013;28(9):1509\u201312. https:\/\/doi.org\/10.1016\/j.arth.2013.03.014.","journal-title":"J Arthroplasty"},{"issue":"1","key":"2894_CR21","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1186\/s12891-022-05983-6","volume":"23","author":"LM H\u00e4gerich","year":"2022","unstructured":"H\u00e4gerich LM, Dyrna FGE, Katthagen JC, Michel PA, Heilmann LF, Frank A, et al. Cerclage performance analysis - a Biomechanical comparison of different techniques and materials. BMC Musculoskelet Disord. 2022;23(1):1037. https:\/\/doi.org\/10.1186\/s12891-022-05983-6.","journal-title":"BMC Musculoskelet Disord"},{"issue":"3","key":"2894_CR22","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1177\/1758573217735323","volume":"11","author":"SE Westberg","year":"2019","unstructured":"Westberg SE, Acklin YP, Hoxha S, Ayranci C, Adeeb S, Bouliane M. Is suture comparable to wire for cerclage fixation? A Biomechanical analysis. Shoulder Elb. 2019;11(3):225\u201332.","journal-title":"Shoulder Elb"},{"issue":"1","key":"2894_CR23","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1007\/s00264-012-1702-7","volume":"37","author":"M Lenz","year":"2013","unstructured":"Lenz M, Perren SM, Richards RG, Muckley T, Hofmann GO, Gueorguiev B, et al. Biomechanical performance of different cable and wire cerclage configurations. Int Orthop. 2013;37(1):125\u201330.","journal-title":"Int Orthop"},{"issue":"3","key":"2894_CR24","doi-asserted-by":"publisher","first-page":"208","DOI":"10.55095\/achot2011\/033","volume":"78","author":"D W\u00e4hnert","year":"2011","unstructured":"W\u00e4hnert D, Lenz M, Schlegel U, Perren S, Windolf M. Cerclage handling for improved fracture treatment. A Biomechanical study on the twisting procedure. Acta Chir Orthop Traumatol Cech. 2011;78(3):208\u201314.","journal-title":"Acta Chir Orthop Traumatol Cech"},{"issue":"3","key":"2894_CR25","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1007\/s00264-023-06041-z","volume":"48","author":"KP van Knegsel","year":"2024","unstructured":"van Knegsel KP, Zderic I, Kastner P, Varga P, Knobe M, Berk T, et al. Knot holding capacity of two different high-strength sutures-a Biomechanical analysis. Int Orthop. 2024;48(3):643\u20139. https:\/\/doi.org\/10.1007\/s00264-023-06041-z.","journal-title":"Int Orthop"},{"issue":"10","key":"2894_CR26","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.1016\/j.injury.2019.06.034","volume":"50","author":"I Peeters","year":"2019","unstructured":"Peeters I, Depover A, Van Tongel A, De Wilde L. A review of metallic and non-metallic cerclage in orthopaedic surgery: is there still a place for metallic cerclage? Injury. 2019;50(10):1627\u201333.","journal-title":"Injury"},{"issue":"1","key":"2894_CR27","doi-asserted-by":"publisher","first-page":"e86035","DOI":"10.1371\/journal.pone.0086035","volume":"9","author":"G Bergmann","year":"2014","unstructured":"Bergmann G, Bender A, Graichen F, Dymke J, Rohlmann A, Trepczynski A, et al. Standardized loads acting in knee implants. PLoS ONE. 2014;9(1):e86035.","journal-title":"PLoS ONE"},{"issue":"3","key":"2894_CR28","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1007\/s00590-023-03806-5","volume":"34","author":"P Kalmet","year":"2024","unstructured":"Kalmet P, Maduro C, Verstappen C, Meys G, van Horn Y, van Vugt R, et al. Effectiveness of permissive weight bearing in surgically treated trauma patients with peri- and intra-articular fractures of the lower extremities: a prospective comparative multicenter cohort study. Eur J Orthop Surg Traumatol. 2024;34(3):1363\u201371. https:\/\/doi.org\/10.1007\/s00590-023-03806-5.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2894_CR29","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1051\/sicotj\/2019005","volume":"5","author":"M Baer","year":"2019","unstructured":"Baer M, Neuhaus V, Pape HC, Ciritsis B. Influence of mobilization and weight bearing on in-hospital outcome in geriatric patients with hip fractures. SICOT J. 2019;5:4. https:\/\/doi.org\/10.1051\/sicotj\/2019005.","journal-title":"SICOT J"},{"issue":"11","key":"2894_CR30","doi-asserted-by":"publisher","first-page":"936","DOI":"10.2106\/JBJS.17.01222","volume":"100","author":"C Kammerlander","year":"2018","unstructured":"Kammerlander C, Pfeufer D, Lisitano LA, Mehaffey S, Bocker W, Neuerburg C. Inability of older adult patients with hip fracture to maintain postoperative Weight-Bearing restrictions. J Bone Joint Surg Am. 2018;100(11):936\u201341.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"2894_CR31","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1007\/s00068-018-1016-6","volume":"46","author":"DPJ Smeeing","year":"2020","unstructured":"Smeeing DPJ, Houwert RM, Briet JP, Groenwold RHH, Lansink KWW, Leenen LPH, et al. Weight-bearing or non-weight-bearing after surgical treatment of ankle fractures: a multicenter randomized controlled trial. Eur J Trauma Emerg Surg. 2020;46(1):121\u201330. https:\/\/doi.org\/10.1007\/s00068-018-1016-6.","journal-title":"Eur J Trauma Emerg Surg"},{"key":"2894_CR32","doi-asserted-by":"publisher","first-page":"215145932110558","DOI":"10.1177\/21514593211055889","volume":"12","author":"M Paulsson","year":"2021","unstructured":"Paulsson M, Ekholm C, Jonsson E, Geijer M, Rolfson O. Immediate full Weight-Bearing versus partial Weight-Bearing after plate fixation of distal femur fractures in elderly patients. A randomized controlled trial. Geriatr Orthop Surg Rehabil. 2021;12:21514593211055889. https:\/\/doi.org\/10.1177\/21514593211055889.","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"2894_CR33","doi-asserted-by":"publisher","first-page":"106379","DOI":"10.1016\/j.clinbiomech.2024.106379","volume":"121","author":"M Hollensteiner","year":"2024","unstructured":"Hollensteiner M, Baumeister D, Muhling M, Greinwald M, Sandriesser S, Hofstatter B, et al. Population-specific femur models: A step towards improved osteosynthetic Biomechanical testing in orthopaedics. Clin Biomech (Bristol). 2024;121:106379. https:\/\/doi.org\/10.1016\/j.clinbiomech.2024.106379.","journal-title":"Clin Biomech (Bristol)"},{"key":"2894_CR34","doi-asserted-by":"publisher","first-page":"104210","DOI":"10.1016\/j.medengphy.2024.104210","volume":"130","author":"M Hollensteiner","year":"2024","unstructured":"Hollensteiner M, Sandriesser S, Libert J, Spitzer-Vanech L, Baumeister D, Greinwald M, et al. Biomechanical validation of novel polyurethane-resin synthetic osteoporotic femoral bones in axial compression, four-point bending and torsion. Med Eng Phys. 2024;130:104210. https:\/\/doi.org\/10.1016\/j.medengphy.2024.104210.","journal-title":"Med Eng Phys"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-025-02894-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-025-02894-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-025-02894-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T10:15:02Z","timestamp":1781604902000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-025-02894-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,11]]},"references-count":34,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["2894"],"URL":"https:\/\/doi.org\/10.1007\/s00068-025-02894-8","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,11]]},"assertion":[{"value":"10 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"227"}}