{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T19:17:49Z","timestamp":1770751069850,"version":"3.50.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T00:00:00Z","timestamp":1758585600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T00:00:00Z","timestamp":1758585600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"University of Bern"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Persistent malalignment\u2014especially rotational error\u2014after fixation of comminuted femoral shaft fractures compromises function and often necessitates revision surgery. This study evaluated whether point-of-care, patient-specific three-dimensional printed reduction guides can reproducibly restore native femoral length, coronal\u2013sagittal alignment and axial rotation in a cadaveric model simulating highly comminuted shaft fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Ten freshfrozen human legs were CTscanned, virtually reduced, and fitted with patientspecific guides printed in a sterilizable medical resin. A 2\u00a0cm midshaft segment was resected to simulate a comminuted fracture. Each construct was reduced with the guides and stabilized with a locking compression plate. Postoperative CT volumes were superimposed to the preoperative plan to quantify absolute deviations in length, coronal (varus\/valgus), sagittal (procurvatum\/recurvatum), and axial rotation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>All reductions were completed without technical difficulty. Mean\u2009\u00b1\u2009SD absolute errors were 1.50\u2009\u00b1\u20091.08\u00a0mm in length, 0.92\u2009\u00b1\u20090.41\u00b0 in the coronal plane, 1.33\u2009\u00b1\u20091.34\u00b0 in the sagittal plane, and 4.33\u2009\u00b1\u20091.88\u00b0 in rotation\u2014well within acceptable clinical limits.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>On\u2011site printed, patient\u2011specific guides achieved high accuracy in a comminuted femoral fracture model. Clinical studies are required to determine whether this accuracy translates into improved patient outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00068-025-02970-z","type":"journal-article","created":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T12:00:23Z","timestamp":1758628823000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["High-Accuracy reduction of comminuted diaphyseal femur fractures using on-site 3-D-printed guides"],"prefix":"10.1007","volume":"51","author":[{"given":"Sophie C.","family":"Eberlein","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel F.","family":"Schaible","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank M.","family":"Klenke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Hecker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,9,23]]},"reference":[{"key":"2970_CR1","doi-asserted-by":"publisher","first-page":"14","DOI":"10.23750\/abm.v91i14-S.10725","volume":"91","author":"L Branca Vergano","year":"2020","unstructured":"Branca Vergano L, Coviello G, Monesi M. Rotational malalignment in femoral nailing: prevention, diagnosis and surgical correction. Acta Biomed Atenei Parmensis. 2020;91:14\u2013S. https:\/\/doi.org\/10.23750\/abm.v91i14-S.10725.","journal-title":"Acta Biomed Atenei Parmensis"},{"issue":"2","key":"2970_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2021.102805","volume":"107","author":"B Orfeuvre","year":"2021","unstructured":"Orfeuvre B, Tonetti J, Kerschbaumer G, Barthelemy R, Moreau-Gaudry A, Boudissa M. EOS stereographic assessment of femoral shaft malunion after intramedullary nailing. A prospective series of 48 patients at 9 months\u2019 follow-up. Orthopaedics & Traumatology: Surgery & Research. 2021;107(2):102805. https:\/\/doi.org\/10.1016\/j.otsr.2021.102805.","journal-title":"Orthopaedics & Traumatology: Surgery & Research"},{"issue":"3","key":"2970_CR3","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1007\/s43465-020-00331-z","volume":"55","author":"JM Jankowski","year":"2021","unstructured":"Jankowski JM, Szukics PF, Shah JK, Keller DM, Pires RE, Liporace FA, et al. Comparing intramedullary nailing versus locked plating in the treatment of native distal femur fractures: is one superior to the other?? Indian J Orthop. 2021;55(3):646\u201354. https:\/\/doi.org\/10.1007\/s43465-020-00331-z.","journal-title":"Indian J Orthop"},{"issue":"8","key":"2970_CR4","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1302\/0301-620X.86B8.15663","volume":"86","author":"RL Jaarsma","year":"2004","unstructured":"Jaarsma RL, Van Kampen A. Rotational malalignment after fractures of the femur. J Bone Joint Surg Br Volume. 2004;86(8):1100\u20134.","journal-title":"J Bone Joint Surg Br Volume"},{"issue":"1","key":"2970_CR5","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-022-00535-2","volume":"9","author":"A Hecker","year":"2022","unstructured":"Hecker A, Eberlein SC, Klenke FM. 3D printed fracture reduction guides planned and printed at the point of care show high accuracy\u2013a porcine feasibility study. J Exp Orthop. 2022;9(1):99.","journal-title":"J Exp Orthop"},{"issue":"Suppl 1","key":"2970_CR6","first-page":"1","volume":"125","author":"C Fang","year":"2022","unstructured":"Fang C, Cai L, Chu G, Jarayabhand R, Kim JW, O\u2019Neill G. 3D printing in fracture treatment: current practice and best practice consensus. Unfallchirurgie. 2022;125(Suppl 1):1\u20137.","journal-title":"Unfallchirurgie"},{"issue":"1","key":"2970_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4055\/cios23294","volume":"17","author":"AP McAnena","year":"2024","unstructured":"McAnena AP, McClennen T, Zheng H. Patient-specific 3-dimensional-printed orthopedic implants and surgical devices are potential alternatives to conventional technology but require additional characterization. Clin Orthop Surg. 2024;17(1):1.","journal-title":"Clin Orthop Surg"},{"issue":"1","key":"2970_CR8","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1186\/s12938-016-0236-4","volume":"15","author":"P Tack","year":"2016","unstructured":"Tack P, Victor J, Gemmel P, Annemans L. 3D-printing techniques in a medical setting: a systematic literature review. Biomed Eng Online. 2016;15(1):115. https:\/\/doi.org\/10.1186\/s12938-016-0236-4.","journal-title":"Biomed Eng Online"},{"key":"2970_CR9","doi-asserted-by":"publisher","DOI":"10.1007\/s00104-015-0049-1","author":"F Baumann","year":"2015","unstructured":"Baumann F, Angerpointner K, Nerlich M, Neumann C. Die relevante achsabweichung. Chirurg. 2015. https:\/\/doi.org\/10.1007\/s00104-015-0049-1.","journal-title":"Chirurg"},{"key":"2970_CR10","doi-asserted-by":"publisher","DOI":"10.3109\/17453679209154844","author":"M Br\u00e5ten","year":"1992","unstructured":"Br\u00e5ten M, Terjesen T, Rossvoll I. Femoral anteversion in normal adults. Ultrasound measurements in 50 men and 50 women. Acta Orthop Scand. 1992. https:\/\/doi.org\/10.3109\/17453679209154844.","journal-title":"Acta Orthop Scand"},{"issue":"2","key":"2970_CR11","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1016\/j.injury.2010.08.024","volume":"42","author":"R Buckley","year":"2011","unstructured":"Buckley R, Mohanty K, Malish D. Lower limb malrotation following MIPO technique of distal femoral and proximal tibial fractures. Injury. 2011;42(2):194\u20139.","journal-title":"Injury"},{"key":"2970_CR12","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-013-1289-8","author":"O Karaman","year":"2014","unstructured":"Karaman O, Ayhan E, Kesmezacar H, Seker A, Unlu MC, Aydingoz O. Rotational malalignment after closed intramedullary nailing of femoral shaft fractures and its influence on daily life. Eur J Orthop Surg Traumatol. 2014. https:\/\/doi.org\/10.1007\/s00590-013-1289-8.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2970_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/S0030-5898(20)31925-8","author":"DG Eckhoff","year":"1994","unstructured":"Eckhoff DG. Effect of limb malrotation on malalignment and osteoarthritis. Orthop Clin North Am. 1994. https:\/\/doi.org\/10.1016\/S0030-5898(20)31925-8.","journal-title":"Orthop Clin North Am"},{"key":"2970_CR14","unstructured":"Gofton JP, Trueman GE. Studies in osteoarthritis of the hip. II. Osteoarthritis of the hip and leg-length disparity. Can Med Assoc J 1971;104."},{"key":"2970_CR15","doi-asserted-by":"publisher","DOI":"10.3238\/arztebl.2020.0405","author":"B Vogt","year":"2020","unstructured":"Vogt B, Gosheger G, Wirth T, Horn J, R\u00f6dl R. Leg length discrepancy- treatment indications and strategies. Dtsch Arztebl Int. 2020. https:\/\/doi.org\/10.3238\/arztebl.2020.0405.","journal-title":"Dtsch Arztebl Int"},{"key":"2970_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-010-1245-6","author":"M Citak","year":"2011","unstructured":"Citak M, Suero EM, O\u2019Loughlin PF, Arvani M, Hufner T, Krettek C. Femoral malrotation following intramedullary nailing in bilateral femoral shaft fractures. Arch Orthop Trauma Surg. 2011. https:\/\/doi.org\/10.1007\/s00402-010-1245-6.","journal-title":"Arch Orthop Trauma Surg"},{"key":"2970_CR17","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-015-0793-x","author":"L Vlachopoulos","year":"2015","unstructured":"Vlachopoulos L, Schweizer A, Graf M, Nagy L, Furnstahl P. Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guides. BMC Musculoskelet Disord. 2015. https:\/\/doi.org\/10.1186\/s12891-015-0793-x.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"2970_CR18","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-020-00224-y","volume":"7","author":"SF Fucentese","year":"2020","unstructured":"Fucentese SF, Meier P, Jud L, K\u00f6chli G-L, Aichmair A, Vlachopoulos L, et al. Accuracy of 3d-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy. J Exp Orthop. 2020;7(1):7. https:\/\/doi.org\/10.1186\/s40634-020-00224-y.","journal-title":"J Exp Orthop"},{"key":"2970_CR19","unstructured":"Neagu TP, \u0162igli\u015f M, Cocolo\u015f I, Jecan CR. The relationship between periosteum and fracture healing. Romanian J Morphol Embryol 2016;57."},{"issue":"5","key":"2970_CR20","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1097\/bot.0000000000002790","volume":"38","author":"DV Ivanov","year":"2024","unstructured":"Ivanov DV, Welby JP, Khanna A, Barlow JD, Sems SA, Torchia ME, et al. Evaluation of intraoperative fluoroscopic techniques to estimate femoral rotation: a cadaveric study. J Orthop Trauma. 2024;38(5):279\u201384. https:\/\/doi.org\/10.1097\/bot.0000000000002790.","journal-title":"J Orthop Trauma"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-025-02970-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-025-02970-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-025-02970-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T11:05:31Z","timestamp":1770721531000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-025-02970-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,23]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["2970"],"URL":"https:\/\/doi.org\/10.1007\/s00068-025-02970-z","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,23]]},"assertion":[{"value":"7 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"295"}}