{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T15:14:46Z","timestamp":1780413286844,"version":"3.54.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T00:00:00Z","timestamp":1780358400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T00:00:00Z","timestamp":1780358400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Pelvic fractures, though accounting for only 3% of skeletal injuries, carry a high mortality rate, primarily due to the associated risk of hemodynamic instability. Sacroiliac (SI) screw fixation is a common surgical intervention, which can be technically challenging due to the complex pelvic anatomy. Imaging techniques have evolved from 2D to 3D imaging for its improved accuracy in screw placement. The impact of this transition for SI screw placement was evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method<\/jats:title>\n                    <jats:p>\n                      A single-center observational retrospective study was performed between 2013 and 2023. Patients\u2009\n                      <jats:italic>\u2265<\/jats:italic>\n                      \u200918 years who underwent SI screw placement following pelvic injuries were analyzed. 2D imaging was used until 2021, after which 3D imaging was implemented. Outcomes included the need for revision surgery during initial admission and &lt;\u200918 months after trauma.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      2D imaging was used in 42 patients and 3D imaging in 44 patients. Baseline characteristics and injury severity of both groups were comparable. In the 2D group, 18 patients (42.9%) had suboptimal placement of the SI screw. Of these, 3 (7.1%) required revision surgery due to malpositioned screws. In contrast, no patients (0.0%) in the 3D group had suboptimally positioned screws or underwent revision surgery, (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.22).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>Intraoperative 3D imaging enhanced the accuracy of SI screw placement, leading to an encouraging reduction in suboptimally placed SI screws. This improvement contributed a trend of fewer secondary revision surgeries and complications. These results suggested benefits of applying 3D imaging broadly.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00068-026-03215-3","type":"journal-article","created":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T14:41:45Z","timestamp":1780411305000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Major improvement using peroperative 3D compared to 2D imaging for SI screw fixation in traumatic pelvic fractures"],"prefix":"10.1007","volume":"52","author":[{"given":"F. J. C.","family":"van Eerten","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K. E. M.","family":"Benders","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. C. P. M.","family":"van Baal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Hietbrink","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,2]]},"reference":[{"key":"3215_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.injury.2004.05.029","volume":"36","author":"MRW Grotz","year":"2005","unstructured":"Grotz MRW, Allami MK, Harwood P, Pape HC, Krettek C, Giannoudis PV. Open pelvic fractures: epidemiology, current concepts of management and outcome. Injury. 2005;36:1\u201313. https:\/\/doi.org\/10.1016\/j.injury.2004.05.029.","journal-title":"Injury"},{"key":"3215_CR2","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/s13017-017-0117-6","volume":"12","author":"F Coccolini","year":"2017","unstructured":"Coccolini F, Stahel PF, Montori G, Biffl W, Horer TM, Catena F, et al. Pelvic trauma: WSES classification and guidelines. World J Emerg Surg. 2017;12:5. https:\/\/doi.org\/10.1186\/s13017-017-0117-6.","journal-title":"World J Emerg Surg"},{"key":"3215_CR3","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s00590-017-2044-3","volume":"28","author":"DO Verbeek","year":"2018","unstructured":"Verbeek DO, Ponsen KJ, Fiocco M, Amodio S, Leenen LPH, Goslings JC. Pelvic fractures in the Netherlands: epidemiology, characteristics and risk factors for in-hospital mortality in the older and younger population. Eur J Orthop Surg Traumatol. 2018;28:197\u2013205. https:\/\/doi.org\/10.1007\/s00590-017-2044-3.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"3215_CR4","doi-asserted-by":"publisher","first-page":"3953","DOI":"10.1007\/s00330-018-5303-8","volume":"28","author":"D Dreizin","year":"2018","unstructured":"Dreizin D, Bodanapally U, Mascarenhas D, O\u2019Toole RV, Tirada N, Issa G, et al. Quantitative MDCT assessment of binder effects after pelvic ring disruptions using segmented pelvic haematoma volumes and multiplanar caliper measurements. Eur Radiol. 2018;28:3953\u201362. https:\/\/doi.org\/10.1007\/s00330-018-5303-8.","journal-title":"Eur Radiol"},{"key":"3215_CR5","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1097\/01.ta.0000242259.67486.15","volume":"63","author":"PV Giannoudis","year":"2007","unstructured":"Giannoudis PV, Grotz MRW, Tzioupis C, Dinopoulos H, Wells GE, Bouamra O, et al. Prevalence of Pelvic Fractures, Associated Injuries, and Mortality: The United Kingdom Perspective. J Trauma: Injury Infect Crit Care. 2007;63:875\u201383. https:\/\/doi.org\/10.1097\/01.ta.0000242259.67486.15.","journal-title":"J Trauma: Injury Infect Crit Care"},{"key":"3215_CR6","doi-asserted-by":"publisher","unstructured":"Hartensuer R, Lodde MF, Keller J, Eveslage M, Stolberg-Stolberg J, Riesenbeck O, et al. Safety, effect and feasibility of percutaneous SI-screw with and without augmentation-A 15-year retrospective analysis on over 640 screws. J Clin Med. 2020;9. https:\/\/doi.org\/10.3390\/jcm9082660.","DOI":"10.3390\/jcm9082660"},{"key":"3215_CR7","doi-asserted-by":"publisher","first-page":"278","DOI":"10.5455\/medarh.2011.65.278-282","volume":"65","author":"P Grubor","year":"2011","unstructured":"Grubor P, Milicevic S, Biscevic M, Tanjga R. Selection of treatment method for pelvic ring fractures. Med Arh. 2011;65:278\u201382. https:\/\/doi.org\/10.5455\/medarh.2011.65.278-282.","journal-title":"Med Arh"},{"key":"3215_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1302\/0301-620X.70B1.3276697","volume":"70","author":"M Tile","year":"1988","unstructured":"Tile M. Pelvic ring fractures: should they be fixed? J Bone Joint Surg Br. 1988;70:1\u201312. https:\/\/doi.org\/10.1302\/0301-620X.70B1.3276697.","journal-title":"J Bone Joint Surg Br"},{"key":"3215_CR9","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1007\/s00264-015-3007-0","volume":"40","author":"G Camino Willhuber","year":"2016","unstructured":"Camino Willhuber G, Zderic I, Gras F, Wahl D, Sancineto C, Barla J, et al. Analysis of sacro-iliac joint screw fixation: does quality of reduction and screw orientation influence joint stability? A biomechanical study. Int Orthop. 2016;40:1537\u201343. https:\/\/doi.org\/10.1007\/s00264-015-3007-0.","journal-title":"Int Orthop"},{"key":"3215_CR10","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1007\/s11548-016-1465-5","volume":"12","author":"SC Thakkar","year":"2017","unstructured":"Thakkar SC, Thakkar RS, Sirisreetreerux N, Carrino JA, Shafiq B, Hasenboehler EA. 2D versus 3D fluoroscopy-based navigation in posterior pelvic fixation: review of the literature on current technology. Int J Comput Assist Radiol Surg. 2017;12:69\u201376. https:\/\/doi.org\/10.1007\/s11548-016-1465-5.","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3215_CR11","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/1754-9493-5-8","volume":"5","author":"EA Hasenboehler","year":"2011","unstructured":"Hasenboehler EA, Stahel PF, Williams A, Smith WR, Newman JT, Symonds DL, et al. Prevalence of sacral dysmorphia in a prospective trauma population: Implications for a safe surgical corridor for sacro-iliac screw placement. Patient Saf Surg. 2011;5:8. https:\/\/doi.org\/10.1186\/1754-9493-5-8.","journal-title":"Patient Saf Surg"},{"key":"3215_CR12","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1097\/00005131-200005000-00007","volume":"14","author":"DA Carlson","year":"2000","unstructured":"Carlson DA, Scheid DK, Maar DC, Baele JR, Kaehr DM. Safe placement of S1 and S2 iliosacral screws: the vestibule concept. J Orthop Trauma. 2000;14:264\u20139. https:\/\/doi.org\/10.1097\/00005131-200005000-00007.","journal-title":"J Orthop Trauma"},{"key":"3215_CR13","unstructured":"Dutch National Trauma Registry (DNTR). 2020. Landelijk Netwerk Acute Zorg (LNAZ). 2024. https:\/\/www.lnaz.nl\/trauma\/landelijke-traumaregistratie."},{"key":"3215_CR14","unstructured":"Association for the Advancement of Automotive Medicine. Abbreviated Injury Scale (AIS). https:\/\/www.aaam.org\/abbreviated-injury-scale-ais\/"},{"key":"3215_CR15","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1007\/s00264-010-1092-7","volume":"35","author":"L Grossterlinden","year":"2011","unstructured":"Grossterlinden L, Rueger J, Catala-Lehnen P, Rupprecht M, Lehmann W, R\u00fccker A, et al. Factors influencing the accuracy of iliosacral screw placement in trauma patients. Int Orthop. 2011;35:1391\u20136. https:\/\/doi.org\/10.1007\/s00264-010-1092-7.","journal-title":"Int Orthop"},{"key":"3215_CR16","unstructured":"R Core Team. A language and environment for statistical computing. R Foundation for Statistical Computing. Vienna, Austria 2017. Vienna, Austria; 2017."},{"key":"3215_CR17","doi-asserted-by":"publisher","first-page":"1502","DOI":"10.1097\/TA.0b013e318246efe5","volume":"72","author":"JA Bishop","year":"2012","unstructured":"Bishop JA, Routt MLC. Osseous fixation pathways in pelvic and acetabular fracture surgery: osteology, radiology, and clinical applications. J Trauma Acute Care Surg. 2012;72:1502\u20139. https:\/\/doi.org\/10.1097\/TA.0b013e318246efe5.","journal-title":"J Trauma Acute Care Surg"},{"key":"3215_CR18","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1007\/s00402-009-1039-x","volume":"130","author":"M Beck","year":"2010","unstructured":"Beck M, Kr\u00f6ber M, Mittlmeier T. Intraoperative three-dimensional fluoroscopy assessment of iliosacral screws and lumbopelvic implants stabilizing fractures of the os sacrum. Arch Orthop Trauma Surg. 2010;130:1363\u20139. https:\/\/doi.org\/10.1007\/s00402-009-1039-x.","journal-title":"Arch Orthop Trauma Surg"},{"key":"3215_CR19","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1007\/s11548-011-0652-7","volume":"7","author":"D Behrendt","year":"2012","unstructured":"Behrendt D, M\u00fctze M, Steinke H, Koestler M, Josten C, B\u00f6hme J. Evaluation of 2D and 3D navigation for iliosacral screw fixation. Int J Comput Assist Radiol Surg. 2012;7:249\u201355. https:\/\/doi.org\/10.1007\/s11548-011-0652-7.","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3215_CR20","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1302\/0301-620X.98B5.36287","volume":"98\u2013B","author":"AA Theologis","year":"2016","unstructured":"Theologis AA, Burch S, Pekmezci M. Placement of iliosacral screws using 3D image-guided (O-Arm) technology and Stealth Navigation: comparison with traditional fluoroscopy. Bone Joint J. 2016;98\u2013B:696\u2013702. https:\/\/doi.org\/10.1302\/0301-620X.98B5.36287.","journal-title":"Bone Joint J"},{"key":"3215_CR21","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1016\/j.injury.2007.01.024","volume":"38","author":"U St\u00f6ckle","year":"2007","unstructured":"St\u00f6ckle U, Schaser K, K\u00f6nig B. Image guidance in pelvic and acetabular surgery\u2013expectations, success and limitations. Injury. 2007;38:450\u201362. https:\/\/doi.org\/10.1016\/j.injury.2007.01.024.","journal-title":"Injury"},{"key":"3215_CR22","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1186\/s12893-019-0501-0","volume":"19","author":"G Osterhoff","year":"2019","unstructured":"Osterhoff G, Noser J, Sprengel K, Simmen H-P, Werner CML. Rate of intraoperative problems during sacroiliac screw removal: expect the unexpected. BMC Surg. 2019;19:39. https:\/\/doi.org\/10.1186\/s12893-019-0501-0.","journal-title":"BMC Surg"},{"key":"3215_CR23","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1097\/BOT.0000000000001453","volume":"33","author":"J Quade","year":"2019","unstructured":"Quade J, Busel G, Beebe M, Auston D, Shah AR, Infante A, et al. Symptomatic Iliosacral Screw Removal After Pelvic Trauma-Incidence and Clinical Impact. J Orthop Trauma. 2019;33:351\u20133. https:\/\/doi.org\/10.1097\/BOT.0000000000001453.","journal-title":"J Orthop Trauma"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-026-03215-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-026-03215-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-026-03215-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T14:41:50Z","timestamp":1780411310000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-026-03215-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,2]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3215"],"URL":"https:\/\/doi.org\/10.1007\/s00068-026-03215-3","relation":{},"ISSN":["1863-9941"],"issn-type":[{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,2]]},"assertion":[{"value":"18 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the UMCU ethical review committee (25U-0085_QoPF) The processing and storage of data were in accordance with privacy and ethics regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"178"}}