{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T07:13:58Z","timestamp":1780470838421,"version":"3.54.1"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:00Z","timestamp":1780444800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:00Z","timestamp":1780444800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Freiburg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>Peripheral intravenous catheters (PIVC) are widely used clinical devices for administering fluids or essential drugs to patients. The failure rate of PIVC remains high and Emergency Medicine has been shown to be a risk factor for dislodgement. When the skin is moist from sweat or fluids, standard intra-hospital dressings and securements fail. In emergency situations, a failed catheter can then critically delay intravenous therapies. The most effective dressing to prevent accidental removal of a prehospital PIVC remains unclear. It was the aim of this study to compare the force required to dislodge a PIVC with four different methods of securing PIVCs used in emergency medicine. In addition, the costs were calculated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Artificial sweat was applied to the skin of 180 volunteers. PIVCs were attached onto the forearm using four different securements (elastic gauze, cohesive gauze, clingfilm and a velcro securing device). Continuously increasing traction force was applied until dislodgement of the respective securement. For statistical tests, either Friedman\u2019s test or repeated measures ANOVA was used.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Clingfilm showed the greatest resistance to increasing pulling force with cohesive bandages as close second. The velcro securing device was strongest at resisting low level of forces but fell off sharply at higher force. Elastic bandages were the weakest in both categories. Clingfilm was the most cost-effective method (4ct), followed by elastic gauze (12 ct), cohesive gauze (60 ct) and the velcro device (316 ct).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In situations where intravenous catheters are difficult to secure or at high risk of dislodgement either clingfilm or cohesive dressing should be used. Simple elastic bandages should not be used in any setting for securement of PIVC.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00068-026-03227-z","type":"journal-article","created":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T06:33:10Z","timestamp":1780468390000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Dislodgement forces and cost effectiveness of prehospital securement of peripheral intravenous catheters on moist skin: a randomized controlled clinical trial in healthy volunteers"],"prefix":"10.1007","volume":"52","author":[{"given":"Johannes","family":"Vogeler","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Schumann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Heinrich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johannes","family":"Hell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Axel","family":"Schmutz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,3]]},"reference":[{"issue":"2","key":"3227_CR1","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.auec.2022.08.006","volume":"26","author":"E Golling","year":"2023","unstructured":"Golling E, van de Mortel T, Barr N, Zimmerman PA. Pre-hospital peripheral intravenous catheter insertion practice: an integrative review. Australasian Emerg Care. 2023;26(2):105\u201312. https:\/\/doi.org\/10.1016\/j.auec.2022.08.006.","journal-title":"Australasian Emerg Care"},{"key":"3227_CR2","doi-asserted-by":"publisher","unstructured":"Marsh N, Webster J, Larson E, Cooke M, Mihala G, Rickard CM. Observational study of peripheral intravenous catheter outcomes in adult hospitalized patients: a multivariable analysis of peripheral intravenous catheter failure. J Hosp Med. 2018; 13(2): 83\u20139. https:\/\/doi.org\/10.12788\/jhm.2867. PMID: 29073316.","DOI":"10.12788\/jhm.2867"},{"issue":"4","key":"3227_CR3","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.java.2018.07.002","volume":"23","author":"N Moureau","year":"2018","unstructured":"Moureau N. Impact and safety associated with accidental dislodgement of vascular access devices: a survey of professions, settings, and devices. J Associ Vasc Access. 2018;23(4):203\u201315. https:\/\/doi.org\/10.1016\/j.java.2018.07.002.","journal-title":"J Association Vascular Access"},{"key":"3227_CR4","doi-asserted-by":"crossref","unstructured":"Macklin D, Phlebitis. A painful complication of peripheral IV catheterization that may be prevented. AJN Am J Nurs. 2003;103(2).","DOI":"10.1097\/00000446-200302000-00027"},{"key":"3227_CR5","doi-asserted-by":"publisher","first-page":"103409","DOI":"10.1016\/j.ijnurstu.2019.103409","volume":"100","author":"A Corley","year":"2019","unstructured":"Corley A, Ullman AJ, Mihala G, Ray-Barruel G, Alexandrou E, Rickard CM. Peripheral intravenous catheter dressing and securement practice is associated with site complications and suboptimal dressing integrity: a secondary analysis of 40,637 catheters. Int J Nurs Stud. 2019;100:103409. https:\/\/doi.org\/10.1016\/j.ijnurstu.2019.103409.","journal-title":"Int J Nurs Stud"},{"key":"3227_CR6","doi-asserted-by":"publisher","unstructured":"Marsh N, Mihala G, Ray-Barruel G, Webster J, Wallis MC, Rickard CM. Inter-rater agreement on PIVC-associated phlebitis signs, symptoms and scales. J Eval Clin Pract. 2015;21(5): 893\u20139. https:\/\/doi.org\/10.1111\/jep.12396. PMID: 26183837.","DOI":"10.1111\/jep.12396"},{"key":"3227_CR7","doi-asserted-by":"publisher","unstructured":"Rickard CM, Marsh N, Webster J, et al. Dressings and securements for the prevention of peripheral intravenous catheter failure in adults (SAVE): a pragmatic, randomised controlled, superiority trial. Lancet. 2018;392(10145):419\u201330. https:\/\/doi.org\/10.1016\/S0140-67361831380-1. PMID: 30057103.","DOI":"10.1016\/S0140-67361831380-1"},{"key":"3227_CR8","doi-asserted-by":"publisher","unstructured":"Marsh N, Webster J, Mihala G, Rickard CM. Devices and dressings to secure peripheral venous catheters: a cochrane systematic review and meta-analysis. Int J Nurs Stud. 2017;67:12\u20139. https:\/\/doi.org\/10.1016\/j.ijnurstu.2016.11.007. PMID: 27889585.","DOI":"10.1016\/j.ijnurstu.2016.11.007"},{"issue":"11","key":"3227_CR9","doi-asserted-by":"publisher","first-page":"931","DOI":"10.7205\/MILMED.170.11.931","volume":"170","author":"E Fried","year":"2005","unstructured":"Fried E, Shochat T, Har-even Y, Cohen Y. Evaluation of intravenous cannula and administration set fixation methods. Mil Med. 2005;170(11):931\u20134. https:\/\/doi.org\/10.7205\/MILMED.170.11.931.","journal-title":"Mil Med"},{"key":"3227_CR10","doi-asserted-by":"publisher","DOI":"10.3390\/jcm9103192","author":"A Schmutz","year":"2020","unstructured":"Schmutz A, Menz L, Schumann S, Heinrich S. Dislodgement forces and cost effectiveness of dressings and securement for peripheral intravenous catheters: a randomized controlled trial. J Clin Med. 2020. https:\/\/doi.org\/10.3390\/jcm9103192.","journal-title":"J Clin Med"},{"key":"3227_CR11","doi-asserted-by":"publisher","unstructured":"Benjamin R, Mackie, et al. Securing cannulas in combat: an in vitro study of three intravenous securement techniques. J High Threat Austere Med. 2023;5(1). https:\/\/doi.org\/10.33235\/JHTAM.5.1.3-9.","DOI":"10.33235\/JHTAM.5.1.3-9"},{"key":"3227_CR12","doi-asserted-by":"publisher","unstructured":"Morgan TR. Evaluation of fluid bolus administration rates using ruggedized field intravenous systems. Wilderness Environ Med. 2014;25(2):204\u20139. https:\/\/doi.org\/10.1016\/j.wem.2013.12.026. PMID: 24631229.","DOI":"10.1016\/j.wem.2013.12.026"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-026-03227-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-026-03227-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-026-03227-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T06:33:17Z","timestamp":1780468397000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-026-03227-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,3]]},"references-count":12,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3227"],"URL":"https:\/\/doi.org\/10.1007\/s00068-026-03227-z","relation":{},"ISSN":["1863-9941"],"issn-type":[{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,3]]},"assertion":[{"value":"12 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors did not use a generative artificial intelligence (AI) tool or service to assist with preparation or editing of this work. The author(s) take full responsibility for the content of this publication.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declaration of generative AI in scientific writing"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"179"}}