{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T16:59:04Z","timestamp":1785517144650,"version":"3.56.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T00:00:00Z","timestamp":1785283200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T00:00:00Z","timestamp":1785283200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"DOI":"10.1007\/s00068-026-03276-4","type":"journal-article","created":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T08:21:00Z","timestamp":1785313260000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["\u201cIs the effect of intraoperative 3D imaging beneficial in plate fixation of distal radius fractures: a matched-pair analysis\u201d"],"prefix":"10.1007","volume":"52","author":[{"given":"Jonin Serafin","family":"Zumsteg","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Pieringer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle Antonia","family":"Hinkelmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karina","family":"Isenmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans-Christoph","family":"Pape","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florin","family":"Allemann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christiane","family":"Barthel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,29]]},"reference":[{"key":"3276_CR1","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1186\/s12891-020-3097-8","volume":"21","author":"J Rundgren","year":"2020","unstructured":"Rundgren J, Bojan A, Mellstrand Navarro C, Enocson A. Epidemiology, classification, treatment and mortality of distal radius fractures in adults: an observational study of 23,394 fractures from the national Swedish fracture register. BMC Musculoskelet Disord. 2020;21:88.","journal-title":"BMC Musculoskelet Disord"},{"key":"3276_CR2","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1302\/0301-620X.90B10.21293","volume":"90","author":"N Downing","year":"2008","unstructured":"Downing N, Karantana A. A revolution in the management of fractures of the distal radius? J Bone Joint Surg Br. 2008;90:1271\u20135.","journal-title":"J Bone Joint Surg Br"},{"key":"3276_CR3","doi-asserted-by":"publisher","first-page":"22","DOI":"10.3944\/AOTT.2012.2623","volume":"46","author":"T Sugun","year":"2012","unstructured":"Sugun T, et al. Results of volar locking plating for unstable distal radius fractures. Acta Orthop Traumatol Turc. 2012;46:22\u20135.","journal-title":"Acta Orthop Traumatol Turc"},{"key":"3276_CR4","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1142\/S0218810400000223","volume":"5","author":"JL Orbay","year":"2000","unstructured":"Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5:103\u201312.","journal-title":"Hand Surg"},{"key":"3276_CR5","doi-asserted-by":"publisher","first-page":"1414","DOI":"10.1016\/j.jhsa.2013.04.019","volume":"38","author":"K Lutsky","year":"2013","unstructured":"Lutsky K, Boyer M, Goldfarb C. Dorsal locked plate fixation of distal radius fractures. J Hand Surg. 2013;38:1414\u201322.","journal-title":"J Hand Surg"},{"key":"3276_CR6","doi-asserted-by":"publisher","first-page":"1810","DOI":"10.1016\/j.injury.2018.06.023","volume":"49","author":"M Bergsma","year":"2018","unstructured":"Bergsma M, et al. Volar plating in distal radius fractures: a prospective clinical study on efficacy of dorsal tangential views to avoid screw penetration. Injury. 2018;49:1810\u20135.","journal-title":"Injury"},{"key":"3276_CR7","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1016\/j.injury.2013.01.008","volume":"44","author":"T Toros","year":"2013","unstructured":"Toros T, S\u00fcg\u00fcn TS, \u00d6zaksar K. Complications of distal radius locking plates. Injury. 2013;44:336\u20139.","journal-title":"Injury"},{"key":"3276_CR8","doi-asserted-by":"publisher","first-page":"1610","DOI":"10.1302\/0301-620X.88B12.17696","volume":"88","author":"M Al-Rashid","year":"2006","unstructured":"Al-Rashid M, Theivendran K, Craigen M. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br. 2006;88:1610\u20132.","journal-title":"J Bone Joint Surg Br"},{"key":"3276_CR9","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1097\/01.blo.0000223998.02765.0d","volume":"451","author":"EC Benson","year":"2006","unstructured":"Benson EC, DeCarvalho A, Mikola EA, Veitch JM, Moneim MS. Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res. 2006;451:218\u201322.","journal-title":"Clin Orthop Relat Res"},{"key":"3276_CR10","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1016\/j.jhsa.2008.10.002","volume":"34","author":"AD Thomas","year":"2009","unstructured":"Thomas AD, Greenberg JA. Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: a cadaveric study. J Hand Surg. 2009;34:258\u201361.","journal-title":"J Hand Surg"},{"key":"3276_CR11","doi-asserted-by":"crossref","unstructured":"Guidi M, et al. Dorsal cortical screw penetration in volar distal radius plating: comparison of 3 fluoroscopic views. Plast. Reconstr. Surgery\u2013Global Open 2024;12:e6320.","DOI":"10.1097\/GOX.0000000000006320"},{"key":"3276_CR12","doi-asserted-by":"crossref","unstructured":"Ozer K, Toker S. Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating. 2011.","DOI":"10.1007\/s11552-010-9316-2"},{"key":"3276_CR13","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1007\/s11552-007-9038-2","volume":"2","author":"SD Maschke","year":"2007","unstructured":"Maschke SD, Evans PJ, Schub D, Drake R, Lawton JN. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand. 2007;2:144\u201350.","journal-title":"Hand"},{"key":"3276_CR14","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/S0020-1383(01)00174-7","volume":"33","author":"S Batra","year":"2002","unstructured":"Batra S, Gupta A. The effect of fracture-related factors on the functional outcome at 1 year in distal radius fractures. Injury. 2002;33:499\u2013502.","journal-title":"Injury"},{"key":"3276_CR15","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/0363-5023(94)90028-0","volume":"19","author":"TE Trumble","year":"1994","unstructured":"Trumble TE, Schmitt SR, Vedder NB. Factors affecting functional outcome of displaced intra-articular distal radius fractures. J Hand Surg. 1994;19:325\u201340.","journal-title":"J Hand Surg"},{"key":"3276_CR16","doi-asserted-by":"publisher","first-page":"328","DOI":"10.2106\/JBJS.J.00193","volume":"93","author":"M Soong","year":"2011","unstructured":"Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. JBJS. 2011;93:328\u201335.","journal-title":"JBJS"},{"key":"3276_CR17","doi-asserted-by":"publisher","first-page":"1091","DOI":"10.1016\/j.jhsa.2013.03.011","volume":"38","author":"A Kitay","year":"2013","unstructured":"Kitay A, et al. Volar plate position and flexor tendon rupture following distal radius fracture fixation. J Hand Surg. 2013;38:1091\u20136.","journal-title":"J Hand Surg"},{"key":"3276_CR18","doi-asserted-by":"crossref","unstructured":"B\u0130LG\u0130N Y, Ekinci M, Ozmen Z, Birisik F. Radiological measurement parameters of distal radius and wrist measured on X-rays in the Turkish population. North Clin Istanb. 2023;10.","DOI":"10.14744\/nci.2022.56514"},{"key":"3276_CR19","doi-asserted-by":"publisher","first-page":"1418","DOI":"10.2106\/00004623-199274090-00018","volume":"74","author":"F Schuind","year":"1992","unstructured":"Schuind F, Linscheid R, An K-N, Chao E. A normal data base of posteroanterior roentgenographic measurements of the wrist. JBJS. 1992;74:1418\u201329.","journal-title":"JBJS"},{"key":"3276_CR20","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.jhsg.2019.02.002","volume":"1","author":"CJ Symonette","year":"2019","unstructured":"Symonette CJ, MacDermid JC, Grewal R. Radiographic thresholds with increased odds of a poor outcome following distal radius fractures in patients over 65 years old. J Hand Surg Glob Online. 2019;1:65\u20139.","journal-title":"J Hand Surg Glob Online"},{"key":"3276_CR21","doi-asserted-by":"crossref","unstructured":"Kumar S, et al. Functional outcomes of intra-articular distal radius fractures: single-incision three-column fixation using volar locking plate and K-wire stabilization. Cureus. 2025;17.","DOI":"10.7759\/cureus.92032"},{"key":"3276_CR22","doi-asserted-by":"publisher","first-page":"502","DOI":"10.5435\/JAAOS-21-08-502","volume":"21","author":"J Murray","year":"2013","unstructured":"Murray J, Gross L. Treatment of distal radius fractures. JAAOS-J Am Acad Orthop Surg. 2013;21:502\u20135.","journal-title":"JAAOS-J Am Acad Orthop Surg"},{"key":"3276_CR23","doi-asserted-by":"publisher","first-page":"174","DOI":"10.4103\/NJCA.NJCA_22_25","volume":"14","author":"OJW Rajadurai","year":"2025","unstructured":"Rajadurai OJW, Chhetri P, Nandagopal D. Radiological parameters and functional outcomes in distal radius fractures: A narrative review. Natl J Clin Anat. 2025;14:174\u20139.","journal-title":"Natl J Clin Anat"},{"key":"3276_CR24","doi-asserted-by":"publisher","first-page":"101743","DOI":"10.1016\/j.hansur.2024.101743","volume":"43","author":"F Labbe","year":"2024","unstructured":"Labbe F, Daoulas T, Letissier H, Liverneaux P, Ducournau F. Distal radius fracture osteosynthesis by volar locking plate: influence of epiphyseal screw positioning on risk of loss of reduction. Hand Surg Rehabil. 2024;43:101743.","journal-title":"Hand Surg Rehabil"},{"key":"3276_CR25","doi-asserted-by":"publisher","first-page":"647","DOI":"10.2106\/00004623-198668050-00003","volume":"68","author":"JL Knirk","year":"1986","unstructured":"Knirk JL, Jupiter JB. Intra-articular fractures of the distal end of the radius in young adults. JBJS. 1986;68:647\u201359.","journal-title":"JBJS"},{"key":"3276_CR26","unstructured":"American Academy of Orthopaedic Surgeons AAOS. Treatment of Distal radius fractures - appropriate use criteria. March 18 2013. https:\/\/www.aaos.org\/globalassets\/quality-and-practice-resources\/distal-radius\/drf_auc.pdf."},{"key":"3276_CR27","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1007\/s00068-018-1036-2","volume":"46","author":"D Hammerle","year":"2020","unstructured":"Hammerle D, Osterhoff G, Allemann F, Werner CML. Comparison of intraoperative 2D vs. 3D imaging in open reduction and fixation of distal radius fractures. Eur J Trauma Emerg Surg. 2020;46:557\u201363.","journal-title":"Eur J Trauma Emerg Surg"},{"key":"3276_CR28","doi-asserted-by":"publisher","first-page":"2254","DOI":"10.3390\/jcm9072254","volume":"9","author":"S Halvachizadeh","year":"2020","unstructured":"Halvachizadeh S, et al. Is the additional effort for an intraoperative CT scan justified for distal radius fracture fixations? A comparative clinical feasibility study. J Clin Med. 2020;9:2254.","journal-title":"J Clin Med"},{"key":"3276_CR29","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1007\/s00402-018-2867-3","volume":"138","author":"M Schnetzke","year":"2018","unstructured":"Schnetzke M, et al. Intraoperative three-dimensional imaging in the treatment of distal radius fractures. Arch Orthop Trauma Surg. 2018;138:487\u201393.","journal-title":"Arch Orthop Trauma Surg"},{"key":"3276_CR30","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1177\/1753193413476418","volume":"38","author":"I Mehling","year":"2013","unstructured":"Mehling I, et al. Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures. J Hand Surg Eur Vol. 2013;38:751\u20137.","journal-title":"J Hand Surg Eur Vol"},{"key":"3276_CR31","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.jhsa.2019.11.006","volume":"45","author":"CA Selles","year":"2020","unstructured":"Selles CA, et al. The Value of Intraoperative 3-Dimensional Fluoroscopy in the Treatment of Distal Radius Fractures: A Randomized Clinical Trial. J Hand Surg. 2020;45:189\u201395.","journal-title":"J Hand Surg"},{"key":"3276_CR32","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1186\/s13018-025-05573-x","volume":"20","author":"C-H Wung","year":"2025","unstructured":"Wung C-H, et al. Skyline view versus intraoperative 3D fluoroscopy for dorsal screw protrusion identification following volar plating in the treatment of distal radial fracture. J Orthop Surg. 2025;20:190.","journal-title":"J Orthop Surg"},{"key":"3276_CR33","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1186\/s13018-025-06284-z","volume":"20","author":"F Brunken","year":"2025","unstructured":"Brunken F, Bullert B, Gr\u00fctzner PA, Vetter SY, Beisemann N. Comparison of 2D and 3D fluoroscopy for intraoperative detection of intra-articular incongruities in distal radius fractures. J Orthop Surg. 2025;20:824.","journal-title":"J Orthop Surg"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-026-03276-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-026-03276-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-026-03276-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T16:04:27Z","timestamp":1785513867000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-026-03276-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,29]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3276"],"URL":"https:\/\/doi.org\/10.1007\/s00068-026-03276-4","relation":{},"ISSN":["1863-9941"],"issn-type":[{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,29]]},"assertion":[{"value":"26 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the Ethical Committee of the Canton Z\u00fcrich (Study-Nr 2024\u2009\u2212\u200901809). The study was conducted according to our institutional guidelines for good clinical practice and was performed in accordance with the ethical standards of the 1964 Declaration of Helsinki and its later amendments.","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All patients included in this study had signed the General Consent of the University Hospital Zurich, permitting the use of their clinical data for research purposes.","order":2,"name":"Ethics","label":"Consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interest","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"232"}}