{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T18:21:02Z","timestamp":1761675662820},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2009,4,22]],"date-time":"2009-04-22T00:00:00Z","timestamp":1240358400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesist"],"published-print":{"date-parts":[[2009,5]]},"DOI":"10.1007\/s00101-009-1528-x","type":"journal-article","created":{"date-parts":[[2009,4,20]],"date-time":"2009-04-20T16:10:23Z","timestamp":1240243823000},"page":"469-473","source":"Crossref","is-referenced-by-count":5,"title":["Atemwegssicherung bei immobilisierter Halswirbels\u00e4ule"],"prefix":"10.1007","volume":"58","author":[{"given":"R.R.","family":"Noppens","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"M\u00f6bus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Werner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Piepho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2009,4,22]]},"reference":[{"key":"1528_CR1","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1111\/j.1365-2044.1984.tb08932.x","volume":"39","author":"Cormack","year":"1984","unstructured":"Cormack RS, Lehane J (1984) Difficult tracheal intubation in obstetrics. Anaesthesia 39:1105\u20131111","journal-title":"Anaesthesia"},{"key":"1528_CR2","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1007\/s00101-004-0679-z","volume":"53","author":"Thierbach","year":"2004","unstructured":"Thierbach A, Piepho T, Wolcke B et al (2004) Prehospital emergency airway management procedures. Success rates and complications. Anaesthesist 53:543\u2013550","journal-title":"Anaesthesist"},{"key":"1528_CR3","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.resuscitation.2006.01.010","volume":"70","author":"Timmermann","year":"2006","unstructured":"Timmermann A, Eich C, Russo SG et al (2006) Prehospital airway management: a prospective evaluation of anaesthesia trained emergency physicians. Resuscitation 70:179\u2013185","journal-title":"Resuscitation"},{"key":"1528_CR4","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1007\/s001040050322","volume":"68","author":"Wick","year":"1997","unstructured":"Wick M, Ekkernkamp A, Muhr G (1997) The epidemiology of multiple trauma. Chirurg 68:1053\u20131058","journal-title":"Chirurg"},{"key":"1528_CR5","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1007\/s10049-001-0424-y","volume":"5","author":"Beck","year":"2002","unstructured":"Beck A, Gebhard F, Kinzl L (2002) Not\u00e4rztliche Versorgung des Traumapatienten. Notfall Rettungsmed 5:57\u201371","journal-title":"Notfall Rettungsmed"},{"key":"1528_CR6","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1055\/s-2007-993020","volume":"42","author":"Kill","year":"2007","unstructured":"Kill C (2007) Prehospital treatment of severe trauma. Anasthesiol Intensivmed Notfallmed Schmerzther 42:708\u2013714","journal-title":"Anasthesiol Intensivmed Notfallmed Schmerzther"},{"key":"1528_CR7","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1093\/bja\/aei190","volume":"95","author":"Goutcher","year":"2005","unstructured":"Goutcher CM, Lochhead V (2005) Reduction in mouth opening with semi-rigid cervical collars. Br J Anaesth 95:344\u2013348","journal-title":"Br J Anaesth"},{"key":"1528_CR8","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1111\/j.1365-2044.1994.tb04254.x","volume":"49","author":"Heath","year":"1994","unstructured":"Heath KJ (1994) The effect of laryngoscopy of different cervical spine immobilisation techniques. Anaesthesia 49:843\u2013845","journal-title":"Anaesthesia"},{"key":"1528_CR9","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1093\/bja\/aeg560","volume":"90","author":"Agr\u00f2","year":"2003","unstructured":"Agr\u00f2 F, Barzoi G, Montecchia F (2003) Tracheal intubation using a Macintosh laryngoscope or a GlideScope in 15 patients with cervical spine immobilization. Br J Anaesth 90:705\u2013706","journal-title":"Br J Anaesth"},{"key":"1528_CR10","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1111\/j.1365-2044.2007.05316.x","volume":"63","author":"Maharaj","year":"2008","unstructured":"Maharaj CH, Costello JF, Harte BH, Laffey JG (2008) Evaluation of the Airtraq and Macintosh laryngoscopes in patients at increased risk for difficult tracheal intubation. Anaesthesia 63:182\u2013188","journal-title":"Anaesthesia"},{"key":"1528_CR11","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1007\/BF03022777","volume":"54","author":"Shippey","year":"2007","unstructured":"Shippey B, Ray D, McKeown D (2007) Case series: the McGrath videolaryngoscope \u2013 An initial clinical evaluation. Can J Anaesth 54:307\u2013313","journal-title":"Can J Anaesth"},{"key":"1528_CR12","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1213\/ane.0b013e318161769e","volume":"106","author":"Robitaille","year":"2008","unstructured":"Robitaille A, Williams SR, Tremblay MH et al (2008) Cervical spine motion during tracheal intubation with manual in-line stabilization: direct laryngoscopy versus GlideScope videolaryngoscopy. Anesth Analg 106:935\u2013941 (table of contents)","journal-title":"Anesth Analg"},{"key":"1528_CR13","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1093\/bja\/aem303","volume":"100","author":"Shippey","year":"2008","unstructured":"Shippey B, Ray D, McKeown D (2008) Use of the McGrath videolaryngoscope in the management of difficult and failed tracheal intubation. Br J Anaesth 100:116\u2013119","journal-title":"Br J Anaesth"},{"key":"1528_CR14","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1093\/bja\/aen231","volume":"101","author":"Malik","year":"2008","unstructured":"Malik MA, Maharaj CH, Harte BH, Laffey JG (2008) Comparison of Macintosh, Truview EVO2, Glidescope and Airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth 101:723\u2013730","journal-title":"Br J Anaesth"},{"key":"1528_CR15","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1136\/emj.2007.052803","volume":"25","author":"Kim","year":"2008","unstructured":"Kim HJ, Chung SP, Park IC et al (2008) Comparison of the GlideScope video laryngoscope and Macintosh laryngoscope in simulated tracheal intubation scenarios. Emerg Med J 25:279\u2013282","journal-title":"Emerg Med J"},{"key":"1528_CR16","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1111\/j.1365-2044.2008.05653.x","volume":"63","author":"Savoldelli","year":"2008","unstructured":"Savoldelli GL, Schiffer E, Abegg C et al (2008) Comparison of the Glidescope, the McGrath, the Airtraq and the Macintosh laryngoscopes in simulated difficult airways*. Anaesthesia 63:1358\u20131364","journal-title":"Anaesthesia"},{"key":"1528_CR17","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/BF03021895","volume":"54","author":"Jones","year":"2007","unstructured":"Jones PM, Turkstra TP, Armstrong KP et al (2007) Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope. Can J Anaesth 54:21\u201327","journal-title":"Can J Anaesth"},{"key":"1528_CR18","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1111\/j.1365-2044.2008.05480.x","volume":"63","author":"Hirabayashi","year":"2008","unstructured":"Hirabayashi Y, Fujita A, Seo N, Sugimoto H (2008) A comparison of cervical spine movement during laryngoscopy using the Airtraq or Macintosh laryngoscopes. Anaesthesia 63:635\u2013640","journal-title":"Anaesthesia"},{"key":"1528_CR19","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/01.anes.0000267529.71756.f0","volume":"107","author":"Maharaj","year":"2007","unstructured":"Maharaj CH, Buckley E, Harte BH, Laffey JG (2007) Endotracheal intubation in patients with cervical spine immobilization: a comparison of Macintosh and Airtraq laryngoscopes. Anesthesiology 107:53\u201359","journal-title":"Anesthesiology"},{"key":"1528_CR20","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1111\/j.1365-2044.2006.04653.x","volume":"61","author":"Maharaj","year":"2006","unstructured":"Maharaj CH, Costello JF, Higgins BD et al (2006) Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq and Macintosh laryngoscope. Anaesthesia 61:671\u2013677","journal-title":"Anaesthesia"},{"key":"1528_CR21","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1007\/BF03021507","volume":"55","author":"Byhahn","year":"2008","unstructured":"Byhahn C, Nemetz S, Breitkreutz R et al (2008) Brief report: tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy for patients with a simulated difficult airway. Can J Anaesth 55:232\u2013237","journal-title":"Can J Anaesth"},{"key":"1528_CR22","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1111\/j.1365-2044.2005.04224.x","volume":"60","author":"Rudolph","year":"2005","unstructured":"Rudolph C, Schneider JP, Wallenborn J, Schaffranietz L (2005) Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope. Anaesthesia 60:668\u2013672","journal-title":"Anaesthesia"},{"key":"1528_CR23","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1046\/j.1365-2044.2003.03407.x","volume":"58","author":"Halligan","year":"2003","unstructured":"Halligan M, Charters P (2003) A clinical evaluation of the Bonfils intubation fibrescope. Anaesthesia 58:1087\u20131091","journal-title":"Anaesthesia"},{"key":"1528_CR24","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1111\/j.1365-2044.2004.04013.x","volume":"60","author":"Rai","year":"2005","unstructured":"Rai MR, Dering A, Verghese C (2005) The Glidescope system: a clinical assessment of performance. Anaesthesia 60:60\u201364","journal-title":"Anaesthesia"},{"key":"1528_CR25","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1097\/00008506-200610000-00005","volume":"18","author":"Koyama","year":"2006","unstructured":"Koyama J, Aoyama T, Kusano Y et al (2006) Description and first clinical application of AirWay Scope for tracheal intubation. J Neurosurg Anesthesiol 18:247\u2013250","journal-title":"J Neurosurg Anesthesiol"},{"key":"1528_CR26","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1093\/bja\/aen002","volume":"100","author":"Enomoto","year":"2008","unstructured":"Enomoto Y, Asai T, Arai T et al (2008) Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study. Br J Anaesth 100:544\u2013548","journal-title":"Br J Anaesth"},{"key":"1528_CR27","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1007\/BF03022329","volume":"54","author":"Cross","year":"2007","unstructured":"Cross P, Cytryn J, Cheng KK (2007) Perforation of the soft palate using the GlideScope videolaryngoscope. Can J Anaesth 54:588\u2013589","journal-title":"Can J Anaesth"},{"key":"1528_CR28","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1111\/j.1365-2044.2008.05620.x","volume":"63","author":"Holst","year":"2008","unstructured":"Holst B, Hodzovic I, Francis V (2008) Airway trauma caused by the Airtraq laryngoscope. Anaesthesia 63:889\u2013890","journal-title":"Anaesthesia"}],"container-title":["Der Anaesthesist"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00101-009-1528-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00101-009-1528-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00101-009-1528-x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,22]],"date-time":"2019-05-22T22:57:07Z","timestamp":1558565827000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00101-009-1528-x"}},"subtitle":["Pr\u00e4klinischer Einsatz des McGrath\u00ae-Videolaryngoskops"],"short-title":[],"issued":{"date-parts":[[2009,4,22]]},"references-count":28,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2009,5]]}},"alternative-id":["1528"],"URL":"https:\/\/doi.org\/10.1007\/s00101-009-1528-x","relation":{},"ISSN":["0003-2417","1432-055X"],"issn-type":[{"value":"0003-2417","type":"print"},{"value":"1432-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,4,22]]}}}