{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T03:48:57Z","timestamp":1775792937814,"version":"3.50.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2004,9,1]],"date-time":"2004-09-01T00:00:00Z","timestamp":1093996800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Chirurg"],"published-print":{"date-parts":[[2004,9]]},"DOI":"10.1007\/s00104-004-0858-0","type":"journal-article","created":{"date-parts":[[2004,5,26]],"date-time":"2004-05-26T09:19:50Z","timestamp":1085563190000},"page":"916-922","source":"Crossref","is-referenced-by-count":50,"title":["Zuverl\ufffdssigkeit und Konsequenzen des intraoperativen Neuromonitorings in der Schilddr\ufffdsenchirurgie","Effectiveness and results of intraoperative neuromonitoring in thyroid surgery"],"prefix":"10.1007","volume":"75","author":[{"given":"W.","family":"Timmermann","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W. H.","family":"Hamelmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O.","family":"Thomusch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Sekulla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Grond","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H. J.","family":"Neumann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.","family":"Kruse","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H. P.","family":"M\ufffdhlig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Richter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Vo\ufffd","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Dralle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"CR1","doi-asserted-by":"crossref","unstructured":"Brennan J, Moore EJ, Shuler KJ (2001) Prospective analysis of the efficacy of continuous intraoperative nerve monitoring during thyroidectomy, parathyroidectomy, and parotidectomy Otolaryngol Head Neck Surg 124:537","DOI":"10.1067\/mhn.2001.115402"},{"key":"CR2","unstructured":"Dralle H, Kruse E, Hamelmann W et al. (2004) Nicht jeder Stimmlippenstillstand nach Schilddr\u00fcsenoperation ist eine chirurgisch-bedingte Recurrensparese. Chirurg DOI 10.007\/s00104-004-0857-1"},{"key":"CR3","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1097\/00005537-199604000-00010","volume":"106","author":"Eisele","year":"1996","unstructured":"Eisele DW (1996) Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve. Laryngoscope 106:443","journal-title":"Laryngoscope"},{"key":"CR4","first-page":"initial","volume":"surgery","author":"Eltzschig","year":"2002","unstructured":"Eltzschig HK, Posner M, Moore FD Jr (2002) The use of readily available equipment in a simple method for intraoperative monitoring of recurrent laryngeal nerve function during thyroid surgery: initial experience with more than 300 cases. Arch Surg 1374?1452","journal-title":"The use of readily available equipment in a simple method for intraoperative monitoring of recurrent laryngeal nerve function during thyroid"},{"key":"CR5","unstructured":"Flisberg K, Lindholm T (1969) Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation. Acta Otolaryngol (Stockh) [Suppl] 263:63?67"},{"key":"CR6","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1055\/s-2002-31983","volume":"127","author":"Friedrich","year":"2002","unstructured":"Friedrich T, Staemmler A, Hansch U et al. (2002) Anwendung des Neuromonitoring des N.\u00a0laryngeus recurrens in der Schilddr\u00fcsenchirurgie?eine prospektive Studie. Zentralbl Chir 127:414","journal-title":"Zentralbl Chir"},{"key":"CR7","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1055\/s-2002-31982","volume":"127","author":"Hamelmann","year":"2002","unstructured":"Hamelmann WH, Meyer T, Timm S, Timmermann W (2002) Kritische Beurteilung und Fehlerm\u00f6glichkeiten des intraoperativen Neuromonitoring (IONM) bei Operationen an der Schilddr\u00fcse. Zentralbl Chir 127:409","journal-title":"Zentralbl Chir"},{"key":"CR8","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1007\/s001040051100","volume":"71","author":"Hemmerling","year":"2000","unstructured":"Hemmerling TM, Schurr C, Dern S, Schmidt J et al. (2000) Intraoperative electromyographische Recurrensidentifizierung als Routinema\u00dfnahme. Chirurg 71:545","journal-title":"Chirurg"},{"key":"CR9","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1007\/s004230050219","volume":"384","author":"Horn","year":"1999","unstructured":"Horn D, R\u00f6tzscher VM (1999) Intraoperative electromyogram monitoring of the recurrent laryngeal nerve: experience with an intralaryngeal surface electrode. A method to reduce the risk of recurrent laryngeal nerve injury during thyroid surgery. Langenbecks Arch Surg 384:392","journal-title":"Langenbecks Arch Surg"},{"key":"CR10","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1055\/s-2002-31981","volume":"127","author":"Jonas","year":"2002","unstructured":"Jonas J (2002) Wie zuverl\u00e4ssig ist das Neuromonitoring des Nervus laryngeus recurrens in der Schilddr\u00fcsenchirurgie? Zentralbl Chir 127:404","journal-title":"Zentralbl Chir"},{"key":"CR11","first-page":"534","volume":"71","author":"Jonas","year":"2000","unstructured":"Jonas J, B\u00e4hr R (2000) Die intraoperative elektromyographische Identifikation des Nervus laryngeus recurrens Chirurg 71:534","journal-title":"Die intraoperative elektromyographische Identifikation des Nervus laryngeus recurrens Chirurg"},{"key":"CR12","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1007\/s00104-002-0493-6","volume":"73","author":"Jonas","year":"2002","unstructured":"Jonas J, Fischer S, Kaissling G, B\u00e4hr R (2002) Relaxierung und elektromyographische Identifikation des N.\u00a0laryngeus recurrens. Chirurg 73:938","journal-title":"Chirurg"},{"key":"CR13","doi-asserted-by":"crossref","unstructured":"Kienast A, Richter C, Neumann HJ (1998) Intraoperatives Neuromonitoring des Nervus laryngeus recurrens?routinem\u00e4\u00dfiger Einsatz in der Schilddr\u00fcsenchirurgie. Langenbecks Arch Chir [Suppl] Kongressbd. 115:1058?1160","DOI":"10.1007\/978-3-642-45774-6_234"},{"key":"CR14","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1055\/s-2002-31984","volume":"127","author":"Kienast","year":"2002","unstructured":"Kienast A, Weigmann F, Richter C (2002) Neuromonitoring des Nervus recurrens?kritische Betrachtung bei Patienten mit postoperativer Recurrensparese. Zentralbl Chir 127:421","journal-title":"Zentralbl Chir"},{"key":"CR15","first-page":"641","volume":"124","author":"Kunath","year":"1999","unstructured":"Kunath M, Hussock J, Marusch F, Horschig P, Gastinger I (1999) Identifizierung des Nervus laryngeus recurrens durch intraoperatives Neuromonitoring. Zentralbl Chir 124:641","journal-title":"Zentralbl Chir"},{"key":"CR16","first-page":"451","volume":"67","author":"Lamade","year":"1996","unstructured":"Lamade W, Fogel W, Rieke K, Senninger N, Herfarth C (1996) Intraoperatives Monitoring des Nervus laryngeus recurrens. Eine neue Methode. Chirurg 67:451","journal-title":"Chirurg"},{"key":"CR17","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1007\/s001040051101","volume":"71","author":"Lamade","year":"2000","unstructured":"Lamade W, Meyding-Lamade U, Buchhold C et al. (2000) Erstes kontinuierliches Nerven-Monitoring in der Schilddr\u00fcsenchirurgie. Chirurg 71:551","journal-title":"Chirurg"},{"key":"CR18","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.1288\/00005537-198812000-00003","volume":"98","author":"Lipton","year":"1988","unstructured":"Lipton RJ, McCaffrey TV, Litchy WJ (1988) Intraoperative electrophysiologic monitoring of laryngeal muscle during thyroid surgery. Laryngoscope 98:1292","journal-title":"Laryngoscope"},{"key":"CR19","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1177\/014556139407300108","volume":"73","author":"Maloney","year":"1994","unstructured":"Maloney RW, Murcek BW, Steehler KW, Sibly D, Maloney RE (1994) A new method for intraoperative recurrent laryngeal nerve monitoring. Ear Nose Throat J 73:30","journal-title":"Ear Nose Throat J"},{"key":"CR20","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1097\/00005537-200302000-00028","volume":"113","author":"Marcus","year":"2003","unstructured":"Marcus B, Edwards B, Yoo S et al. (2003) Recurrent laryngeal nerve monitoring in thyroid and parathyroid surgery: the University of Michigan experience. Laryngoscope 113:356","journal-title":"Laryngoscope"},{"key":"CR21","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1097\/00005537-199606000-00016","volume":"106","author":"Mermelstein","year":"1996","unstructured":"Mermelstein M, Nonweiler R, Rubinstein EH (1996) Intraoperative identification of laryngeal nerves with laryngeal electromyography. Laryngoscope 106:752","journal-title":"Laryngoscope"},{"key":"CR22","doi-asserted-by":"crossref","unstructured":"Neumann HJ (2000) Intraoperatives neurophysiologisches Monitoring (IONM) des Nervus recurrens und Mikrodissektion Laryngorhinootologie 79:290","DOI":"10.1055\/s-2000-343"},{"key":"CR23","unstructured":"Neumann HJ, Hamelmann WH, Timmermann W (2001) Intraoperatives neurophysiologisches Monitoring des Nervus recurrens. Dtsch \u00c4rztebl 17:963"},{"key":"CR24","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1177\/000348947908800115","volume":"88","author":"Rea","year":"1979","unstructured":"Rea JL, Davis WE, Templer JW (1979) Recurrent nerve locating system. Ann Otol Rhinol Laryngol 88:92","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"CR25","doi-asserted-by":"crossref","unstructured":"Rea JL, Khan A (1998) Clinical evoked electromyography for recurrent laryngeal nerve preservation: use of an endotracheal tube electrode and a postcricoid surface electrode Laryngoscope 108:1418","DOI":"10.1097\/00005537-199809000-00032"},{"key":"CR26","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1177\/019459989110500304","volume":"105","author":"Rice","year":"1991","unstructured":"Rice DH, Cone-Wesson B (1991) Intraoperative recurrent laryngeal nerve monitoring. Otolaryngol Head Neck Surg 105:372","journal-title":"Otolaryngol Head Neck Surg"},{"key":"CR27","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1017\/S0022215100141088","volume":"112","author":"Srinivasan","year":"1998","unstructured":"Srinivasan V, Premachandra DJ (1998) Use of a disposable electrode for recurrent laryngeal nerve monitoring. J Laryngol Otol 112:561","journal-title":"J Laryngol Otol"},{"key":"CR28","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1007\/s002680010221","volume":"24","author":"Thomusch","year":"2000","unstructured":"Thomusch O, Machens A, Sekulla C et al. (2000) Multivariate analysis of risk factors for postoperative complications in benign goiter surgery: prospective multicenter study in Germany. World J Surg 24:1335","journal-title":"World J Surg"},{"key":"CR29","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1007\/s10353-003-0019-6","volume":"35","author":"Thomusch","year":"2003","unstructured":"Thomusch O, Sekulla C, Timmermann W et al. (2003) Intraoperative Neuromonitoring in Thyroid Surgery?Results of the German Prospective Multicenter Study. Eur Surg 35:240","journal-title":"Eur Surg"},{"key":"CR30","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/S0002-9610(02)00856-5","volume":"183","author":"Thomusch","year":"2002","unstructured":"Thomusch O, Sekulla C, Walls G, Machens A, Dralle H (2002) Intraoperative neuromonitoring of surgery for benign goiter. Am J Surg 183:673","journal-title":"Am J Surg"},{"key":"CR31","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1055\/s-2002-31979","volume":"127","author":"Timmermann","year":"2002","unstructured":"Timmermann W, Dralle H, Hamelmann W et al. (2002) Reduziert das intraoperative Neuromonitoring die Recurrenspareserate bei Schilddr\u00fcsenoperationen? Zentralbl Chir 127:395","journal-title":"Zentralbl Chir"},{"key":"CR32","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1055\/s-2007-997197","volume":"73","author":"Tschopp","year":"1994","unstructured":"Tschopp K, Probst R (1994) Neue Aspekte in der Schilddr\u00fcsenchirurgie mit dem intraoperativen Monitoring des N.\u00a0laryngeus recurrens. Laryngorhinootologie 73:568","journal-title":"Laryngorhinootologie"},{"key":"CR33","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1177\/000348940211100909","volume":"111","author":"Tschopp","year":"2002","unstructured":"Tschopp KP, Gottardo C (2002) Comparison of various methods of electromyographic monitoring of the recurrent laryngeal nerve in thyroid surgery. Ann Otol Rhinol Laryngol 111:811","journal-title":"Ann Otol Rhinol Laryngol"}],"container-title":["Der Chirurg"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00104-004-0858-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00104-004-0858-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00104-004-0858-0","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,2]],"date-time":"2020-04-02T07:40:28Z","timestamp":1585813228000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00104-004-0858-0"}},"subtitle":["Stellungnahme der ?Interdisziplin\ufffdren Studiengruppe Intraoperatives Neuromonitoring Schilddr\ufffdsenchirurgie?","Statement of the Interdisciplinary Study Group on Intraoperative Neuromonitoring of Thyroid Surgery"],"short-title":[],"issued":{"date-parts":[[2004,9]]},"references-count":33,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2004,9]]}},"alternative-id":["858"],"URL":"https:\/\/doi.org\/10.1007\/s00104-004-0858-0","relation":{},"ISSN":["0009-4722","1433-0385"],"issn-type":[{"value":"0009-4722","type":"print"},{"value":"1433-0385","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,9]]}}}