{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,3,29]],"date-time":"2022-03-29T16:13:01Z","timestamp":1648570381155},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2005,8,1]],"date-time":"2005-08-01T00:00:00Z","timestamp":1122854400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["HNO"],"published-print":{"date-parts":[[2005,8]]},"DOI":"10.1007\/s00106-004-1203-0","type":"journal-article","created":{"date-parts":[[2005,1,18]],"date-time":"2005-01-18T13:29:00Z","timestamp":1106054940000},"page":"741-746","source":"Crossref","is-referenced-by-count":3,"title":["Einfluss der Magnetresonanztomographie auf Oberlidimplantate"],"prefix":"10.1007","volume":"53","author":[{"given":"T.","family":"Schrom","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Bauknecht","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Berghaus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Scherer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2005,8,1]]},"reference":[{"key":"1203_CR1","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1177\/000348949009901009","volume":"99","author":"Applebaum","year":"1990","unstructured":"Applebaum E, Valvassori G (1990) Further studies on the effects of magnetic resonance imaging fields on middle ear implants. Ann Otol Rhinol Laryngol 99 (10 Pt 1): 801\u2013804","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"1203_CR2","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1097\/00002341-199509000-00008","volume":"11","author":"Bair","year":"1995","unstructured":"Bair R, Harris G, Lyon D, Komorowski R (1995) Noninfectious inflammatory response to gold weight eyelid implants. Ophthalmic Plast Reconstr Surg 11: 209\u2013214","journal-title":"Ophthalmic Plast Reconstr Surg"},{"key":"1203_CR3","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1001\/archfaci.5.2.166","volume":"5","author":"Berghaus","year":"2003","unstructured":"Berghaus A, Neumann K, Schrom T (2003) The platinum chain: a new upper-lid implant for facial palsy. Arch Facial Plast Surg 5 (2): 166\u2013170","journal-title":"Arch Facial Plast Surg"},{"key":"1203_CR4","doi-asserted-by":"crossref","first-page":"1503","DOI":"10.1001\/archopht.1991.01080110037025","volume":"109","author":"Beyer","year":"1991","unstructured":"Beyer T, Sinha S (1991) Eyelid pain after magnetic resonance imaging-induced palpebral spring vibration. Arch Ophthalmol 109: 1503","journal-title":"Arch Ophthalmol"},{"key":"1203_CR5","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1002\/mrm.1910070302","volume":"7","author":"Buchli","year":"1988","unstructured":"Buchli R, Boesiger P, Meier D (1988) Heating effects of metallic implants by MRI examinations. Magn Reson Med 7 (3): 255\u2013261","journal-title":"Magn Reson Med"},{"key":"1203_CR6","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1097\/00000637-199307000-00016","volume":"31","author":"Canady","year":"1993","unstructured":"Canady J, Meine J, Thompson S, Yuh W (1993) Effects of magnetic resonance imaging fields on gold eyelid loads. Ann Plast Surg 31 (1): 76\u201377","journal-title":"Ann Plast Surg"},{"key":"1203_CR7","doi-asserted-by":"crossref","first-page":"857","DOI":"10.2214\/ajr.137.4.857","volume":"137","author":"Davis","year":"1981","unstructured":"Davis P, Crooks L, Arakawa M, McRee R, Kaufman L, Margulis A (1981) Potential hazards in NMR imaging: heating effects of changing magnetic fields and RF fields on small metallic implants. AJR Am J Roentgenol 137 (4): 857\u2013860","journal-title":"AJR Am J Roentgenol"},{"key":"1203_CR8","first-page":"455","volume":"11","author":"Garaventa","year":"1991","unstructured":"Garaventa G, Satragno L, Vellucci F, Pagano M, Pallestrini E (1991) The interactions between metal stapes prostheses and high-intensity magnetic fields during magnetic resonance tomography. Acta Otorhinolaryngol Ital 11 (5): 455\u2013463","journal-title":"Acta Otorhinolaryngol Ital"},{"key":"1203_CR9","doi-asserted-by":"crossref","first-page":"1498","DOI":"10.1001\/archopht.1991.01080110032020","volume":"109","author":"Gardner","year":"1991","unstructured":"Gardner T, Rak K (1991) Magnetic resonance imaging of eyelid springs and gold weights. Arch Ophthalmol 109 (11): 1498","journal-title":"Arch Ophthalmol"},{"key":"1203_CR10","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1055\/s-2007-998619","volume":"66","author":"Huttenbrink","year":"1987","unstructured":"Huttenbrink K, Grosse-Nobis W (1987) Experimental studies and theoretical considerations on the behavior of stapes metal prostheses in the magnetic field of a nuclear magnetic resonance tomograph. Laryngol Rhinol Otol 66 (3): 127\u2013130","journal-title":"Laryngol Rhinol Otol"},{"key":"1203_CR11","first-page":"401","volume":"45","author":"Huttenbrink","year":"1997","unstructured":"Huttenbrink K (1997) Displacement of a Schuknecht prosthesis in cranial MRI. HNO 45 (5): 401","journal-title":"HNO"},{"key":"1203_CR12","first-page":"410","volume":"32","author":"Illig","year":"1958","unstructured":"Illig KM (1958) Eine neue Operationsmethode gegen Lagophthalmus. Klin Monatsbl Augenheilkd 32: 410\u2013411","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"1203_CR13","first-page":"243","volume":"7","author":"Kelly","year":"1986","unstructured":"Kelly W, Paglen P, Pearson J, San Diego A, Soloman M (1986) Ferromagnetism of intraocular foreign body causes unilateral blindness after MR study. AJNR 7: 243\u2013245","journal-title":"AJNR"},{"key":"1203_CR14","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1055\/s-2003-36905","volume":"82","author":"Kwok","year":"2003","unstructured":"Kwok P, Waldeck A, Strutz J (2003) How do metallic middle ear implants behave in the MRI. Laryngorhinootologie 82 (1): 13\u201318","journal-title":"Laryngorhinootologie"},{"key":"1203_CR15","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1177\/000348949510400606","volume":"104","author":"Marra","year":"1995","unstructured":"Marra S, Leonetti J, Konior R, Raslan W (1995) Effect of magnetic resonance imaging on implantable eyelid weights. Ann Otol Rhinol Laryngol 104 (6): 448\u2013452","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"1203_CR16","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1288\/00005537-199308000-00018","volume":"103","author":"May","year":"1993","unstructured":"May M, Mester S, Shapiro A, Kanal E (1993) Gold weight or spring implants and MRI. Laryngoscope 103 (8): 930","journal-title":"Laryngoscope"},{"key":"1203_CR17","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1007\/s003470050167","volume":"94","author":"Mohr","year":"1997","unstructured":"Mohr A (1997) Pr\u00e4tarsale Platin-Iridium-Implantate zur Therapie des Lagophthalmus bei Fazialisparese\u2014Vorl\u00e4ufige Ergebnisse. Ophthalmologe 94: 600\u2013602","journal-title":"Ophthalmologe"},{"key":"1203_CR18","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1097\/00006534-196405000-00004","volume":"33","author":"Morel-Fatio","year":"1964","unstructured":"Morel-Fatio D, Lalardrie JP (1964) Palliative surgical treatment of facial paralysis: the palpebral spring. Plast Reconstr Surg 33: 446\u2013456","journal-title":"Plast Reconstr Surg"},{"key":"1203_CR19","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1007\/BF00265518","volume":"1","author":"M\u00fchlbauer","year":"1973","unstructured":"M\u00fchlbauer W, Segeth H, Viessmann A (1973) Restoration of lid function in facial palsy with permanent magnets. Chir Plast 1: 295","journal-title":"Chir Plast"},{"key":"1203_CR20","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1148\/radiology.147.1.6828719","volume":"147","author":"New","year":"1983","unstructured":"New P, Rosen B, Brady T et al. (1983) Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 147 (1): 139\u2013148","journal-title":"Radiology"},{"key":"1203_CR21","first-page":"271","volume":"177","author":"Schatz","year":"1990","unstructured":"Schatz C, Shelton C, Brown B (1990) Ex vivo evaluation of ferromagnetism for metallic ocular and middle-ear prosthesis exposed to a 1,5\u00a0T MR imager. Radiology 177: 271","journal-title":"Radiology"},{"key":"1203_CR22","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1007\/s001060050393","volume":"47","author":"Schrom","year":"1999","unstructured":"Schrom T, Goldhahn A, Neumann K, Berghaus A (1999) Risiken der Oberlidgoldimplantation bei peripherer Fazialisparese. HNO 47: 262\u2013268","journal-title":"HNO"},{"key":"1203_CR23","first-page":"46","volume":"22","author":"Schrom","year":"2000","unstructured":"Schrom T, Goldhahn A, Stange T, Berghaus A (2000) Implantate zur operativen Therapie des Lagophthalmus. Journal DGPW 22: 46\u201347","journal-title":"Journal DGPW"},{"key":"1203_CR24","first-page":"104","volume":"257","author":"Schrom","year":"2000","unstructured":"Schrom T, Goldhahn A, Berghaus A, Stange T (2000) The platinum chain as a new implant for lid loading. Eur Arch Otorhinolaryngol 257: 104\u2013105","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"1203_CR25","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1001\/archopht.1991.01080030021014","volume":"109","author":"Seiff","year":"1991","unstructured":"Seiff S, Vestel K, Truwit C (1991) Eyelid palpebral springs in patients undergoing magnetic resonance imaging: an area of possible concern. Arch Ophthalmol 109 (3): 319","journal-title":"Arch Ophthalmol"},{"key":"1203_CR26","first-page":"1","volume":"180","author":"Shellock","year":"1990","unstructured":"Shellock F, Curtis J (1990) MR imaging and biomedical implants, materials and devices: an updated review. Radiology 180: 1\u201310","journal-title":"Radiology"},{"key":"1203_CR27","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1055\/s-2004-827424","volume":"176","author":"Sommer","year":"2004","unstructured":"Sommer T, Maintz D, Schmiedel A et al. (2004) High field MR imaging: magnetic field interactions of aneurysm clips, coronary artery stents and iliac artery stents with a 3.0 Tesla MR system. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 176 (5): 731\u2013738","journal-title":"Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr"}],"container-title":["HNO"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00106-004-1203-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00106-004-1203-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00106-004-1203-0","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,23]],"date-time":"2019-05-23T03:45:30Z","timestamp":1558583130000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00106-004-1203-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,8]]},"references-count":27,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2005,8]]}},"alternative-id":["1203"],"URL":"https:\/\/doi.org\/10.1007\/s00106-004-1203-0","relation":{},"ISSN":["0017-6192","1433-0458"],"issn-type":[{"value":"0017-6192","type":"print"},{"value":"1433-0458","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,8]]}}}