{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,2]],"date-time":"2025-12-02T18:36:44Z","timestamp":1764700604176},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2016,11,11]],"date-time":"2016-11-11T00:00:00Z","timestamp":1478822400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["HNO"],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.1007\/s00106-016-0281-0","type":"journal-article","created":{"date-parts":[[2016,11,11]],"date-time":"2016-11-11T08:19:20Z","timestamp":1478852360000},"page":"870-879","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Objektive Ma\u00dfe bei der Anpassung der Prozessoren von Cochleaimplantatsystemen"],"prefix":"10.1007","volume":"64","author":[{"given":"S.","family":"Hoth","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I.","family":"Herisanu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Praetorius","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,11,11]]},"reference":[{"key":"281_CR1","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1097\/00003446-199902000-00005","volume":"20","author":"P Abbas","year":"1999","unstructured":"Abbas P, Brown C, Shallop J, Firszt J, Hughes M, Hong S, Staller S (1999) Summary of results using the Nucleus CI24M implant to record the electrically evoked compound action potential. Ear Hear 20:45\u201359","journal-title":"Ear Hear"},{"issue":"1","key":"281_CR2","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1179\/1754762810Y.0000000001","volume":"13","author":"T Abbeele Van Den","year":"2012","unstructured":"Van Den Abbeele T, No\u00ebl-Petroff N, Akin I, Caner G, Olgun L, Guiraud J, Truy E, Attias J, Raveh E, Belgin E, Sennaroglu G, Basta D, Ernst A, Martini A, Rosignoli M, Levi H, Elidan J, Benghalem A, Amstutz-Montadert I, Lerosey Y, De Vel E, Dhooge I, Hildesheimer M, Kronenberg J, Arnold L (2012) Multicentre investigation on electrically evoked compound action potential and stapedius reflex: how do these objective measures relate to implant programming parameters? Cochlear Implants Int 13(1):26\u201334","journal-title":"Cochlear Implants Int"},{"key":"281_CR3","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1097\/AUD.0b013e3181bdb88f","volume":"31","author":"I Alvarez","year":"2010","unstructured":"Alvarez I, Torre A, Sainz M, Roldan C, Schoesser H, Spitzer P (2010) Using evoked compound action potentials to assess activation of electrodes and predict C\u2011levels in the Tempo+ cochlear implant speech processor. Ear Hear 31:134\u2013145","journal-title":"Ear Hear"},{"issue":"5","key":"281_CR4","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1016\/j.ijporl.2012.01.030","volume":"76","author":"E Baysal","year":"2012","unstructured":"Baysal E, Karatas E, Deniz M, Baglam T, Durucu C, Karatas ZA, Mumbuc S, Kanlikama M (2012) Intra- and postoperative electrically evoked stapedius reflex thresholds in children with cochlear implants. Int J Pediatr Otorhinolaryngol 76(5):649\u2013652","journal-title":"Int J Pediatr Otorhinolaryngol"},{"key":"281_CR5","doi-asserted-by":"crossref","first-page":"141","DOI":"10.3109\/00016489409126032","volume":"114","author":"B Borne Van den","year":"1994","unstructured":"Van den Borne B, Mens LH, Snik AF, Spies TH, van den Broek P (1994) Stapedius reflex and EABR thresholds in experienced users of the nucleus cochlear implant. Acta Otolaryngol Stockh 114:141\u2013143","journal-title":"Acta Otolaryngol Stockh"},{"issue":"3","key":"281_CR6","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/AUD.0b013e3181c9fd86","volume":"31","author":"A Botros","year":"2010","unstructured":"Botros A, Psarros C (2010) Neural response telemetry reconsidered: I. The relevance of ECAP threshold profiles and scaled profiles to cochlear implant fitting. Ear Hear 31(3):367\u2013379","journal-title":"Ear Hear"},{"key":"281_CR7","first-page":"A18","volume-title":"Use of electrically evoked compound action potentials for cochlear implant fitting, a systematic review","author":"JJ Briaire","year":"2016","unstructured":"Briaire JJ, de Vos JJ, Biesheuvel JD, Boot PS, van Gendt MJ, Dekkers OM, Frijns JHM (2016) Use of electrically evoked compound action potentials for cochlear implant fitting, a systematic review. 9th International Symposium on Objective Measures in Auditory Implants (OMAI), Szeged, 15.-18. Jun 2016, S A18"},{"issue":"2","key":"281_CR8","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/00003446-200004000-00009","volume":"21","author":"CJ Brown","year":"2000","unstructured":"Brown CJ, Hughes ML, Luk B, Abbas PJ, Wolaver A, Gervais J (2000) The relationship between EAP and EABR thresholds and levels used to program the Nucleus24 speech processor: data from adults. Ear Hear 21(2):151\u2013163","journal-title":"Ear Hear"},{"issue":"5","key":"281_CR9","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1097\/mao.0b013e3180577919","volume":"28","author":"G Caner","year":"2007","unstructured":"Caner G, Olgun L, G\u00fcltekin G, Balaban M (2007) Optimizing fitting in children using objective measures such as neural response imaging and electrically evoked stapedius reflex threshold. Otol Neurotol 28(5):637\u2013640","journal-title":"Otol Neurotol"},{"issue":"4","key":"281_CR10","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1097\/00003446-200108000-00004","volume":"22","author":"KH Franck","year":"2001","unstructured":"Franck KH, Norton SJ (2001) Estimation of psychophysical levels using the electrically evoked compound action potential measured with the neural response telemetry capabilities of Cochlear Corporation\u2019s CI24M device. Ear Hear 22(4):289\u2013299","journal-title":"Ear Hear"},{"issue":"suppl 4","key":"281_CR11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/14670100.2015.1110372","volume":"16","author":"R Greisiger","year":"2015","unstructured":"Greisiger R, Shallop JK, Hol PK, Elle OJ, Jablonski GE (2015) Cochlear implantees: analysis of behavioral and objective measures for a clinical population of various age groups. Cochlear Implants Int 16(suppl 4):1\u201319","journal-title":"Cochlear Implants Int"},{"issue":"1","key":"281_CR12","first-page":"46","volume":"48","author":"S Hoth","year":"2009","unstructured":"Hoth S (2009) Die Schwelle in der Begriffswelt des Audiologen. Z Audiol 48(1):46\u201349","journal-title":"Z Audiol"},{"issue":"2","key":"281_CR13","first-page":"61","volume":"52","author":"S Hoth","year":"2013","unstructured":"Hoth S (2013) Die Steigung der Diskriminationsfunktion als universelles Ma\u00df zur Beurteilung der G\u00fcte von Methoden der objektiven Schwellenbestimmung. Z Audiol 52(2):61\u201369","journal-title":"Z Audiol"},{"issue":"1","key":"281_CR14","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1097\/00003446-198802000-00010","volume":"9","author":"J Jerger","year":"1988","unstructured":"Jerger J, Oliver TA, Chmiel AR (1988) Prediction of dynamic range from stapedius reflex in cochlear implant patients. Ear Hear 9(1):4\u20138","journal-title":"Ear Hear"},{"key":"281_CR15","first-page":"33","volume":"254","author":"K Kirchhof","year":"1997","unstructured":"Kirchhof K, Hoth S (1997) Measurements of cortical auditory-evoked potentials and stapedial reflexes in cochlear implant patients. Eur Arch Otorhinolaryngol 254:33","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"1","key":"281_CR16","first-page":"62","volume":"5","author":"J Kosaner","year":"2009","unstructured":"Kosaner J, Anderson I, Turan Z, Deibl M (2009) The use of ESRT in fitting children with cochlear implants. Int Adv Otol 5(1):62\u201371","journal-title":"Int Adv Otol"},{"issue":"1","key":"281_CR17","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1179\/146701004807509143","volume":"5","author":"A Lorens","year":"2004","unstructured":"Lorens A, Walkowiak A, Piotrowska A, Skarzynski H, Anderson I (2004) ESRT and MCL correlations in experienced paediatric cochlear implant users. Cochlear Implants Int 5(1):28\u201337","journal-title":"Cochlear Implants Int"},{"issue":"1\u20132","key":"281_CR18","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.heares.2008.04.005","volume":"242","author":"CA Miller","year":"2008","unstructured":"Miller CA, Brown CJ, Abbas PJ, Chi SL (2008) The clinical application of potentials evoked from the peripheral auditory system. Hear Res 242(1\u20132):184\u2013197","journal-title":"Hear Res"},{"key":"281_CR19","isbn-type":"print","volume-title":"Verfahren zur Anpassung und Evaluation von Cochlear Implant Sprachprozessoren","author":"J M\u00fcller-Deile","year":"2009","unstructured":"M\u00fcller-Deile J (2009) Verfahren zur Anpassung und Evaluation von Cochlear Implant Sprachprozessoren. Median, Heidelberg. ISBN 9783941146013","ISBN":"http:\/\/id.crossref.org\/isbn\/9783941146013"},{"key":"281_CR20","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1016\/j.ijporl.2009.12.017","volume":"74","author":"H Muhaimeed Al","year":"2010","unstructured":"Al Muhaimeed H, Al Anazy F, Hamed O, Shubair E (2010) Correlation between NRT measurement level and behavioral levels in pediatrics cochlear implant patients. Int J Pediatr Otorhinolaryngol 74:356\u2013360","journal-title":"Int J Pediatr Otorhinolaryngol"},{"issue":"6","key":"281_CR21","first-page":"S107","volume":"18","author":"M Opie","year":"1997","unstructured":"Opie M, Allum JH, Probst R (1997) Evaluation of electrically elicited stapedius reflex threshold measured through three different cochlear implant systems. Am J Otol 18(6):S107\u2013S108","journal-title":"Am J Otol"},{"issue":"4","key":"281_CR22","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1097\/01.mao.0000178145.14010.25","volume":"26","author":"M Polak","year":"2005","unstructured":"Polak M, Hodges A, Balkany T (2005) ECAP, ESR and subjective levels for two different nucleus 24 electrode arrays. Otol Neurotol 26(4):639\u2013645","journal-title":"Otol Neurotol"},{"issue":"6","key":"281_CR23","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1159\/000066154","volume":"7","author":"GF Smoorenburg","year":"2002","unstructured":"Smoorenburg GF, Willeboer C, van Dijk JE (2002) Speech perception in Nucleus CI24M cochlear implant users with processor setting based on electrically evoked compound action potential thresholds. Audiol Neurotol 7(6):335\u2013347","journal-title":"Audiol Neurotol"},{"issue":"1","key":"281_CR24","doi-asserted-by":"crossref","first-page":"13","DOI":"10.3109\/00206090009073049","volume":"39","author":"K Stephan","year":"2000","unstructured":"Stephan K, Welzl-M\u00fcller K (2000) Post-operative stapedius reflex tests with simultaneous loudness scaling in patients supplied with cochlear implants. Audiology 39(1):13\u201318","journal-title":"Audiology"},{"key":"281_CR25","doi-asserted-by":"crossref","first-page":"227","DOI":"10.3109\/00206098809081593","volume":"27","author":"K Stephan","year":"1988","unstructured":"Stephan K, Welzl-M\u00fcller K, Stiglbrunner H (1988) Stapedius reflex thresholds in cochlear implant patients. Audiology 27:227\u2013233","journal-title":"Audiology"},{"issue":"5","key":"281_CR26","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/j.ijporl.2012.02.037","volume":"76","author":"S Vlahovi\u0107","year":"2012","unstructured":"Vlahovi\u0107 S, \u0160indija B, Aras I, Glun\u010di\u0107 M, Troti\u0107 R (2012) Differences between electrically evoked compound action potential (ECAP) and behavioral measures in children with cochlear implants operated in the school age vs. operated in the first years of life. Int J Pediatr Otorhinolaryngol 76(5):731\u2013739","journal-title":"Int J Pediatr Otorhinolaryngol"},{"issue":"2","key":"281_CR27","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1179\/cim.2008.9.2.70","volume":"9","author":"J Wolfe","year":"2008","unstructured":"Wolfe J, Kasulis H (2008) Relationships among objective measures and speech perception in adult users of the HiResolution Bionic Ear. Cochlear Implants Int 9(2):70\u201381","journal-title":"Cochlear Implants Int"},{"issue":"11","key":"281_CR28","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1007\/s001060050477","volume":"47","author":"A Zehnder","year":"1999","unstructured":"Zehnder A, Allum JHJ, Honegger F, Probst R (1999) Bedeutung der intraoperativ registrierten elektrischen Stapediusreflexschwelle f\u00fcr die Cochlear-implant-Anpassung bei Kindern. HNO 47(11):970\u2013975","journal-title":"HNO"},{"key":"281_CR29","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1159\/000059202","volume-title":"Updates in Cochlear Implantation. Adv Otorhinolaryngol","author":"J Zupancic","year":"2000","unstructured":"Zupancic J, Battelino S (2000) Intraoperative stapedius reflex measurements after deep electrode insertion compared with postoperative fitting values in cochlear implant patients. In: Kim CS, Chang SO, Lim D (Hrsg) Updates in Cochlear Implantation. Adv Otorhinolaryngol, Bd. 57. Karger, Basel, S\u00a0316\u2013319"}],"container-title":["HNO"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00106-016-0281-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00106-016-0281-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00106-016-0281-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,25]],"date-time":"2017-06-25T03:22:02Z","timestamp":1498360922000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00106-016-0281-0"}},"subtitle":["Nutzung von Diskriminationsfunktionen und Betrachtung von Elektrodenprofilen"],"short-title":[],"issued":{"date-parts":[[2016,11,11]]},"references-count":29,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2016,12]]}},"alternative-id":["281"],"URL":"https:\/\/doi.org\/10.1007\/s00106-016-0281-0","relation":{},"ISSN":["0017-6192","1433-0458"],"issn-type":[{"value":"0017-6192","type":"print"},{"value":"1433-0458","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,11,11]]}}}