{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T12:04:34Z","timestamp":1767182674126},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2010,11,18]],"date-time":"2010-11-18T00:00:00Z","timestamp":1290038400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Unfallchirurg"],"published-print":{"date-parts":[[2012,2]]},"DOI":"10.1007\/s00113-010-1871-z","type":"journal-article","created":{"date-parts":[[2010,11,16]],"date-time":"2010-11-16T18:09:49Z","timestamp":1289930989000},"page":"134-144","source":"Crossref","is-referenced-by-count":13,"title":["Minimalinvasive Versorgung geriatrischer und osteoporotischer Femurfrakturen mit polyaxial-winkelstabilem Implantat (NCB-DF\u00ae)"],"prefix":"10.1007","volume":"115","author":[{"given":"B.F.","family":"El-Zayat","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Zettl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Efe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Kr\u00fcger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Eisenberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Ruchholtz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,11,18]]},"reference":[{"key":"1871_CR1","unstructured":"BQS Bundesgesch\u00e4ftsstelle Qualit\u00e4tssicherung gGmbH. Qualit\u00e4t sichtbar machen. BQS-Qualit\u00e4tsreport 2008. D\u00fcsseldorf: BQS Bundesgesch\u00e4ftsstelle Qualit\u00e4tssicherung gGmbH; 2008. ISBN 3-9808704, http:\/\/www.bqs-online.de\/download\/Qualitaetsreport_2008.pdf"},{"key":"1871_CR2","doi-asserted-by":"crossref","first-page":"12","DOI":"10.5435\/00124635-200401000-00003","volume":"12","author":"Su","year":"2004","unstructured":"Su ET, DeWal H, Di Cesare PE (2004) Periprosthetic femoral fractures above total knee replacements. J Am Acad Orthop Surg 12(1):12\u201320","journal-title":"J Am Acad Orthop Surg"},{"key":"1871_CR3","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/S0030-5898(05)70073-0","volume":"30","author":"Berry","year":"1999","unstructured":"Berry DJ (1999) Epidemiology: hip and knee. Orthop Clin North Am 30(2):183\u2013190","journal-title":"Orthop Clin North Am"},{"key":"1871_CR4","doi-asserted-by":"crossref","first-page":"164","DOI":"10.5435\/00124635-199405000-00005","volume":"2","author":"Kelley","year":"1994","unstructured":"Kelley SS (1994) Periprosthetic femoral fractures. J Am Acad Orthop Surg 2(3):164\u2013172","journal-title":"J Am Acad Orthop Surg"},{"key":"1871_CR5","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1097\/00003086-198709000-00029","volume":"222","author":"Culp","year":"1987","unstructured":"Culp RW et al (1987) Supracondylar fracture of the femur following prosthetic knee arthroplasty. Clin Orthop Relat Res 222:212\u2013222","journal-title":"Clin Orthop Relat Res"},{"key":"1871_CR6","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/0883-5403(94)90099-X","volume":"9","author":"Chen","year":"1994","unstructured":"Chen F, Mont MA, Bachner RS (1994) Management of ipsilateral supracondylar femur fractures following total knee arthroplasty. J Arthroplasty 9(5):521\u2013526","journal-title":"J Arthroplasty"},{"key":"1871_CR7","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/0883-5403(94)90098-1","volume":"9","author":"Mont","year":"1994","unstructured":"Mont MA, Maar DC (1994) Fractures of the ipsilateral femur after hip arthroplasty. A statistical analysis of outcome based on 487 patients. J Arthroplasty 9(5):511\u2013519","journal-title":"J Arthroplasty"},{"key":"1871_CR8","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1097\/00005131-200009000-00006","volume":"14","author":"Ostrum","year":"2000","unstructured":"Ostrum RF et al (2000) Prospective comparison of retrograde and antegrade femoral intramedullary nailing. J Orthop Trauma 14(7):496\u2013501","journal-title":"J Orthop Trauma"},{"key":"1871_CR9","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/BF02044354","volume":"24","author":"Janzing","year":"1998","unstructured":"Janzing HM et al (1998) Treatment of distal femoral fractures in the elderly. Results with the retrograde intramedullary supracondylar nail. Unfallchirurgie 24(2):55\u201359","journal-title":"Unfallchirurgie"},{"key":"1871_CR10","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1097\/BOT.0b013e31818896b3","volume":"22","author":"Wilkens","year":"2008","unstructured":"Wilkens KJ, Curtiss S, Lee MA (2008) Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison. J Orthop Trauma 22(9):624\u2013628","journal-title":"J Orthop Trauma"},{"key":"1871_CR11","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1016\/S0140-6736(75)92830-5","volume":"1","author":"Jennett","year":"1975","unstructured":"Jennett B, Bond M (1975) Assessment of outcome after severe brain damage. Lancet 1(7905):480\u2013484","journal-title":"Lancet"},{"key":"1871_CR12","first-page":"4","volume":"Sep","author":"Franz","year":"1998","unstructured":"Franz KLR (1998) Stand der Beurteilungsm\u00f6glichkeit der Prognose nach SHT \u2013 Vorbedingungen f\u00fcr eine Aussage \u00fcber die Prognose. NeuroTraumaNews Sep:4\u20135","journal-title":"NeuroTraumaNews"},{"key":"1871_CR13","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1007\/s00402-007-0396-6","volume":"128","author":"Erhardt","year":"2008","unstructured":"Erhardt JB et al (2008) Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant. Arch Orthop Trauma Surg 128(4):409\u2013416","journal-title":"Arch Orthop Trauma Surg"},{"key":"1871_CR14","first-page":"549","volume":"97","author":"Krettek","year":"1994","unstructured":"Krettek C et al (1994) Osteosynthesis of femur shaft fractures with the unreamed AO-femur nail. Surgical technique and initial clinical results standard lock fixation. Unfallchirurg 97(11):549\u2013567","journal-title":"Unfallchirurg"},{"key":"1871_CR15","doi-asserted-by":"crossref","unstructured":"Johansson JE et al (1981) Fracture of the ipsilateral femur in patients wih total hip replacement. J Bone Joint Surg [Am] 63(9):1435\u20131442","DOI":"10.2106\/00004623-198163090-00009"},{"key":"1871_CR16","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S0030-5898(05)70075-4","volume":"30","author":"Rorabeck","year":"1999","unstructured":"Rorabeck CH, Taylor JW (1999) Classification of periprosthetic fractures complicating total knee arthroplasty. Orthop Clin North Am 30(2):209\u2013214","journal-title":"Orthop Clin North Am"},{"key":"1871_CR17","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/S0030-5898(05)70078-X","volume":"30","author":"Tower","year":"1999","unstructured":"Tower SS, Beals RK (1999) Fractures of the femur after hip replacement: the Oregon experience. Orthop Clin North Am 30(2):235\u2013247","journal-title":"Orthop Clin North Am"},{"key":"1871_CR18","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1097\/00003086-199606000-00029","volume":"Res","author":"Beals","year":"1996","unstructured":"Beals RK, Tower SS (1996) Periprosthetic fractures of the femur. An analysis of 93 fractures. Clin Orthop Relat Res (327):238\u2013246","journal-title":"Clin Orthop Relat"},{"key":"1871_CR19","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1097\/01.blo.0000223987.59702.17","volume":"450","author":"O","year":"2006","unstructured":"O\u2019Toole RV et al (2006) Low complication rate of LISS for femur fractures adjacent to stable hip or knee arthroplasty. Clin Orthop Relat Res 450:203\u2013210","journal-title":"Clin Orthop Relat Res"},{"key":"1871_CR20","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1097\/00005131-200603000-00005","volume":"20","author":"Ricci","year":"2006","unstructured":"Ricci WM et al (2006) Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty. J Orthop Trauma 20(3):190\u2013196","journal-title":"J Orthop Trauma"},{"key":"1871_CR21","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/s00113-003-0723-5","volume":"107","author":"Wick","year":"2004","unstructured":"Wick M et al (2004) Periprosthetic supracondylar femoral fractures: LISS or retrograde intramedullary nailing? Problems with the use of minimally invasive technique. Unfallchirurg 107(3):181\u2013188","journal-title":"Unfallchirurg"},{"key":"1871_CR22","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s00402-005-0075-4","volume":"126","author":"Kaab","year":"2006","unstructured":"Kaab MJ et al (2006) Stabilization of periprosthetic fractures with angular stable internal fixation: a report of 13 cases. Arch Orthop Trauma Surg 126(2):105\u2013110","journal-title":"Arch Orthop Trauma Surg"},{"key":"1871_CR23","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1007\/s00113-005-0955-7","volume":"108","author":"Mittlmeier","year":"2005","unstructured":"Mittlmeier T et al (2005) Periprosthetic fractures after total knee joint arthroplasty. Unfallchirurg 108(6):481\u2013495; quiz 496","journal-title":"Unfallchirurg"},{"key":"1871_CR24","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/s00113-009-1665-3","volume":"113","author":"Pressmar","year":"2009","unstructured":"Pressmar J et al (2009) Results and complications in the treatment of periprosthetic femur fractures with a locked plate system. Unfallchirurg 113:195\u2013202","journal-title":"Unfallchirurg"}],"container-title":["Der Unfallchirurg"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00113-010-1871-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00113-010-1871-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00113-010-1871-z","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,13]],"date-time":"2021-11-13T16:36:39Z","timestamp":1636821399000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00113-010-1871-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11,18]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012,2]]}},"alternative-id":["1871"],"URL":"https:\/\/doi.org\/10.1007\/s00113-010-1871-z","relation":{},"ISSN":["0177-5537","1433-044X"],"issn-type":[{"value":"0177-5537","type":"print"},{"value":"1433-044X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,11,18]]}}}