{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:22:47Z","timestamp":1740108167270,"version":"3.37.3"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2020,3,3]],"date-time":"2020-03-03T00:00:00Z","timestamp":1583193600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,3,3]],"date-time":"2020-03-03T00:00:00Z","timestamp":1583193600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100012681","name":"Universit\u00e4tsklinikum K\u00f6ln","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012681","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Unfallchirurg"],"published-print":{"date-parts":[[2020,5]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title><jats:p>Frakturen des 2.\u00a0Halswirbels mit Beteiligung des Dens axis k\u00f6nnen in der Regel konservativ behandelt werden. Im Fall von hochgradig instabilen Frakturen sowie Pseudarthrosen muss eine Spondylodese C1\/2 in Erw\u00e4gung gezogen werden.<\/jats:p><jats:p>Basierend auf den etablierten Osteosyntheseverfahren zur dorsalen Spondylodese C1\/2 erfolgte bei einem 56-j\u00e4hrigen Patienten bei einer dislozierten Dens-Fraktur die Anwendung einer transartikul\u00e4ren C1\/2-Schraube, konnektiert mit einer Atlas-Massa-lateralis-Schraube in einem Schrauben-Stab-System.<\/jats:p><jats:p>Es traten keine intra- sowie postoperativen Komplikationen auf. Im Beobachtungszeitraum von 36\u00a0Monaten traten keine Schraubenlockerungen bzw. -dislokation auf.<\/jats:p><jats:p>Das hier vorgestellte alternative Verfahren der dorsalen Spondylodese C1\/2 ist eine sichere und effektive Methode, um eine Stabilisierung des Bewegungssegmentes im Fall einer posttraumatischen Instabilit\u00e4t zu erreichen.<\/jats:p>","DOI":"10.1007\/s00113-020-00776-9","type":"journal-article","created":{"date-parts":[[2020,3,3]],"date-time":"2020-03-03T16:52:35Z","timestamp":1583254355000},"page":"408-412","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Die Anwendung von transartikul\u00e4ren Schrauben C1\/2, verbunden mit C1-Massa-lateralis-Schrauben in einem Schrauben-Stab-System","Application of transarticular C1\/2 screws connected with C1 lateral mass screws in a rod-screw system"],"prefix":"10.1007","volume":"123","author":[{"given":"Ali","family":"Harati","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Oni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,3,3]]},"reference":[{"key":"776_CR1","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1227\/00006123-199510000-00012","volume":"37","author":"TJ Coyne","year":"1995","unstructured":"Coyne\u00a0TJ, Fehlings\u00a0MG, Wallace\u00a0MC et al (1995) C1-C2 posterior cervical fusion: long-term evaluation of results and efficacy. Neurosurgery 37:688\u2013692","journal-title":"Neurosurgery"},{"key":"776_CR2","doi-asserted-by":"publisher","first-page":"1491","DOI":"10.1227\/NEU.0b013e318212a4d7","volume":"68","author":"IG Dorward","year":"2011","unstructured":"Dorward\u00a0IG, Wright\u00a0NM (2011) Seven years of experience with C2 translaminar screw fixation: clinical series and review of the literature. Neurosurgery 68:1491\u20131499 (discussion 1499)","journal-title":"Neurosurgery"},{"key":"776_CR3","doi-asserted-by":"publisher","first-page":"151","DOI":"10.3171\/2014.10.SPINE13805","volume":"22","author":"JY Du","year":"2015","unstructured":"Du\u00a0JY, Aichmair\u00a0A, Kueper\u00a0J et al (2015) Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a\u00a0systematic review and meta-analysis. J\u00a0Neurosurg Spine 22:151\u2013161","journal-title":"J Neurosurg Spine"},{"key":"776_CR4","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/BF01400872","volume":"129","author":"A Goel","year":"1994","unstructured":"Goel\u00a0A, Laheri\u00a0V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129:47\u201353","journal-title":"Acta Neurochir (Wien)"},{"key":"776_CR5","doi-asserted-by":"publisher","first-page":"12S","DOI":"10.1177\/2192568218768227","volume":"8","author":"O Gonschorek","year":"2018","unstructured":"Gonschorek\u00a0O, Vordemvenne\u00a0T, Blattert\u00a0T et\u00a0al (2018) Treatment of odontoid fractures: recommendations of the spine section of the German society for orthopaedics and trauma (DGOU). Global Spine\u00a0J 8:12S\u201317S","journal-title":"Global Spine J"},{"key":"776_CR6","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1097\/BSD.0b013e31818da3fe","volume":"22","author":"X Guo","year":"2009","unstructured":"Guo\u00a0X, Ni\u00a0B, Zhao\u00a0W et al (2009) Biomechanical assessment of bilateral C1 laminar hook and C1\u20112 transarticular screws and bone graft for atlantoaxial instability. J\u00a0Spinal Disord Tech 22:578\u2013585","journal-title":"J Spinal Disord Tech"},{"key":"776_CR7","doi-asserted-by":"publisher","first-page":"94","DOI":"10.4103\/sni.sni_10_18","volume":"9","author":"A Harati","year":"2018","unstructured":"Harati\u00a0A, Schulthei\u00df\u00a0R (2018) New technique for C1-C2 fixation. Surg Neurol Int 9:94","journal-title":"Surg Neurol Int"},{"key":"776_CR8","doi-asserted-by":"publisher","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","volume":"26","author":"J Harms","year":"2001","unstructured":"Harms\u00a0J, Melcher\u00a0RP (2001) Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine 26:2467\u20132471","journal-title":"Spine"},{"key":"776_CR9","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1097\/00002517-199212000-00012","volume":"5","author":"B Jeanneret","year":"1992","unstructured":"Jeanneret\u00a0B, Magerl\u00a0F (1992) Primary posterior fusion C1\/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J\u00a0Spinal Disord 5:464\u2013475","journal-title":"J Spinal Disord"},{"key":"776_CR10","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1097\/00000658-191002000-00004","volume":"51","author":"SJ Mixter","year":"1910","unstructured":"Mixter\u00a0SJ, Osgood\u00a0RB (1910) IV. traumatic lesions of the atlas and axis. Ann Surg 51:193\u2013207","journal-title":"Ann Surg"},{"key":"776_CR11","doi-asserted-by":"publisher","first-page":"1494","DOI":"10.1097\/00007632-200207150-00003","volume":"27","author":"DK Resnick","year":"2002","unstructured":"Resnick\u00a0DK, Lapsiwala\u00a0S, Trost\u00a0GR (2002) Anatomic suitability of the C1-C2 complex for pedicle screw fixation. Spine 27:1494\u20131498","journal-title":"Spine"},{"key":"776_CR12","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1227\/01.NEU.0000366109.85796.42","volume":"66","author":"MP Steinmetz","year":"2010","unstructured":"Steinmetz\u00a0MP, Mroz\u00a0TE, Benzel\u00a0EC (2010) Craniovertebral junction: biomechanical considerations. Neurosurgery 66:7\u201312","journal-title":"Neurosurgery"}],"container-title":["Der Unfallchirurg"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00113-020-00776-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00113-020-00776-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00113-020-00776-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,3]],"date-time":"2021-03-03T01:12:40Z","timestamp":1614733960000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00113-020-00776-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,3]]},"references-count":12,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020,5]]}},"alternative-id":["776"],"URL":"https:\/\/doi.org\/10.1007\/s00113-020-00776-9","relation":{},"ISSN":["0177-5537","1433-044X"],"issn-type":[{"type":"print","value":"0177-5537"},{"type":"electronic","value":"1433-044X"}],"subject":[],"published":{"date-parts":[[2020,3,3]]},"assertion":[{"value":"3 March 2020","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}},{"value":"A.\u00a0Harati und P.\u00a0Oni geben an, dass kein Interessenkonflikt besteht.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}},{"value":"F\u00fcr diesen Beitrag wurden von den Autoren keine Studien an Menschen oder Tieren durchgef\u00fchrt. F\u00fcr die aufgef\u00fchrten Studien gelten die jeweils dort angegebenen ethischen Richtlinien. F\u00fcr Bildmaterial oder anderweitige Angaben innerhalb des Manuskripts, \u00fcber die Patienten zu identifizieren sind, liegt von ihnen und\/oder ihren gesetzlichen Vertretern eine schriftliche Einwilligung vor.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}}]}}