{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T18:44:12Z","timestamp":1785869052697,"version":"3.56.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T00:00:00Z","timestamp":1593561600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T00:00:00Z","timestamp":1593561600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Unfallchirurg"],"published-print":{"date-parts":[[2020,10]]},"DOI":"10.1007\/s00113-020-00835-1","type":"journal-article","created":{"date-parts":[[2020,7,1]],"date-time":"2020-07-01T06:40:10Z","timestamp":1593585610000},"page":"764-773","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Minimal-invasive Stabilisierung bei thorakolumbalen osteoporotischen Frakturen","Minimally invasive stabilization of thoracolumbar osteoporotic fractures"],"prefix":"10.1007","volume":"123","author":[{"given":"Klaus John","family":"Schnake","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Max Josef","family":"Scheyerer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrich Josef Albert","family":"Spiegl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Perl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernhard Wilhelm","family":"Ullrich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Gr\u00fcninger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georg","family":"Osterhoff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Katscher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Sprengel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Arbeitsgruppe Osteoporotische Frakturen der Sektion Wirbels\u00e4ule","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,7,1]]},"reference":[{"key":"835_CR1","doi-asserted-by":"publisher","first-page":"2562","DOI":"10.1097\/01.brs.0000240695.58651.62","volume":"31","author":"G Baroud","year":"1976","unstructured":"Baroud\u00a0G, Crookshank\u00a0M, Bohner\u00a0M (1976) High-viscosity cement significantly enhances uniformity of cement filling in vertebroplasty: an experimental model and study on cement leakage. Spine 31:2562\u20132568","journal-title":"Spine"},{"key":"835_CR2","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1093\/neuros\/nyy017","volume":"84","author":"DP Beall","year":"2019","unstructured":"Beall\u00a0DP, Chambers\u00a0MR, Thomas\u00a0S et\u00a0al (2019) Prospective and multicenter evaluation of outcomes for quality of life and activities of daily living for balloon Kyphoplasty in the treatment of vertebral compression fractures: the EVOLVE trial. Neurosurgery 84:169\u2013178","journal-title":"Neurosurgery"},{"key":"835_CR3","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1097\/BRS.0b013e31818f8bc1","volume":"34","author":"TR Blattert","year":"2009","unstructured":"Blattert\u00a0TR, Jestaedt\u00a0L, Weckbach\u00a0A (2009) Suitability of a\u00a0calcium phosphate cement in osteoporotic vertebral body fracture augmentation: a\u00a0controlled, randomized, clinical trial of balloon kyphoplasty comparing calcium phosphate versus polymethylmethacrylate. Spine 34:108\u2013114","journal-title":"Spine"},{"key":"835_CR4","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1007\/s00132-018-03666-6","volume":"48","author":"TR Blattert","year":"2019","unstructured":"Blattert\u00a0TR, Schnake\u00a0KJ, Gonschorek\u00a0O et\u00a0al (2019) Nichtoperative und operative Behandlung der osteoporotischen Wirbelk\u00f6rperfraktur. Empfehlungen der SektionWirbels\u00e4ule der Deutschen Gesellschaft f\u00fcr Orthop\u00e4die und Unfallchirurgie (DGOU). Orthopade 48:84\u201391","journal-title":"Orthopade"},{"key":"835_CR5","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1007\/s00198-006-0304-x","volume":"18","author":"AM Briggs","year":"2007","unstructured":"Briggs\u00a0AM, Greig\u00a0AM, Wark\u00a0JD (2007) The vertebral fracture cascade in osteoporosis: a\u00a0review of aetiopathogenesis. Osteoporos Int 18:575\u2013584","journal-title":"Osteoporos Int"},{"key":"835_CR6","doi-asserted-by":"publisher","first-page":"E317","DOI":"10.1097\/BRS.0b013e31816f6c73","volume":"33","author":"MC Chang","year":"2008","unstructured":"Chang\u00a0MC, Liu\u00a0CL, Chen\u00a0TH (2008) Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a\u00a0novel technique. Spine 33:E317\u2013E324","journal-title":"Spine"},{"key":"835_CR7","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1115\/1.2796022","volume":"118","author":"JR Chapman","year":"1996","unstructured":"Chapman\u00a0JR, Harrington\u00a0RM, Lee\u00a0KM et\u00a0al (1996) Factors affecting the pullout strength of cancellous bone screws. J\u00a0Biomech Eng 118:391\u2013398","journal-title":"J Biomech Eng"},{"issue":"1976","key":"835_CR8","doi-asserted-by":"publisher","first-page":"E1628","DOI":"10.1097\/BRS.0b013e3182740e56","volume":"37","author":"TJ Choma","year":"2012","unstructured":"Choma\u00a0TJ, Pfeiffer\u00a0FM, Swope\u00a0RW, Hirner\u00a0JP (2012) Pedicle screw design and cement augmentation in osteoporotic vertebrae: effects of fenestrations and cement viscosity on fixation and extraction. Spine 37(1976):E1628\u20131632","journal-title":"Spine"},{"key":"835_CR9","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1093\/bja\/aen328","volume":"102","author":"A Donaldson","year":"2009","unstructured":"Donaldson\u00a0A, Thomson\u00a0H, Harper\u00a0N, Kenny\u00a0N (2009) Bone cement implantation syndrome. Br J Anaesth 102:12\u201322","journal-title":"Br J Anaesth"},{"key":"835_CR10","doi-asserted-by":"publisher","first-page":"1432","DOI":"10.1016\/j.spinee.2015.03.016","volume":"15","author":"BD Elder","year":"2015","unstructured":"Elder\u00a0BD, Lo\u00a0SFL, Holmes\u00a0C et\u00a0al (2015) The biomechanics of pedicle screw augmentation with cement. Spine\u00a0J 15:1432\u20131445","journal-title":"Spine J"},{"key":"835_CR11","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1007\/s00068-013-0319-x","volume":"39","author":"A El Saman","year":"2013","unstructured":"El Saman\u00a0A, Kelm\u00a0A, Meier\u00a0S et al (2013) Intraoperative PEEP-ventilation during PMMA-injection for augmented pedicle screws: improvement of leakage rate in spinal surgery. Eur J Trauma Emerg Surg 39:461\u2013468","journal-title":"Eur J Trauma Emerg Surg"},{"key":"835_CR12","doi-asserted-by":"publisher","first-page":"47","DOI":"10.3171\/SPI-07\/07\/047","volume":"7","author":"BM Frankel","year":"2007","unstructured":"Frankel\u00a0BM, D\u2019Agostino\u00a0S, Wang\u00a0C (2007) A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation. J\u00a0Neurosurg Spine 7:47\u201353","journal-title":"J Neurosurg Spine"},{"key":"835_CR13","doi-asserted-by":"publisher","first-page":"1385","DOI":"10.1007\/s00586-011-1766-x","volume":"20","author":"F Geiger","year":"2011","unstructured":"Geiger\u00a0F, Kafchitsas\u00a0K, Rauschmann\u00a0M (2011) Anterior vertebroplasty of adjacent levels after vertebral body replacement. Eur Spine\u00a0J 20:1385\u20131392","journal-title":"Eur Spine J"},{"issue":"3 Suppl","key":"835_CR14","doi-asserted-by":"publisher","first-page":"185S","DOI":"10.1016\/8756-3282(95)00500-5","volume":"18","author":"DT Gold","year":"1996","unstructured":"Gold\u00a0DT (1996) The clinical impact of vertebral fractures: quality of life in women with osteoporosis. Bone 18(3 Suppl):185S\u2013189S","journal-title":"Bone"},{"issue":"Suppl 2","key":"835_CR15","doi-asserted-by":"publisher","first-page":"S23","DOI":"10.1016\/8756-3282(92)90192-Y","volume":"13","author":"RP Heaney","year":"1992","unstructured":"Heaney\u00a0RP (1992) The natural history of vertebral osteoporosis: is low bonemass an epiphenomenon? Bone 13(Suppl 2):S23\u2013S26","journal-title":"Bone"},{"key":"835_CR16","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1055\/s-0032-1328522","volume":"151","author":"C Hoffmann","year":"2013","unstructured":"Hoffmann\u00a0C, Spiegl\u00a0UJ, Hauck\u00a0S et\u00a0al (2013) Die ventrale Spondylodese beim \u00e4lteren Patienten \u2013 Overtreatment oder sinnvolle Therapieoption ? Z\u00a0Orthop Unfall 151:257\u2013263","journal-title":"Z Orthop Unfall"},{"key":"835_CR17","doi-asserted-by":"publisher","first-page":"3463","DOI":"10.1007\/s00586-015-4191-8","volume":"25","author":"S Hoppe","year":"2016","unstructured":"Hoppe\u00a0S, Elfiky\u00a0T, Keel\u00a0MJB (2016) Lavage prior to vertebral augmentation reduces the risk for cement leakage. Eur Spine\u00a0J 25:3463\u20133469","journal-title":"Eur Spine J"},{"key":"835_CR18","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1016\/j.spinee.2017.01.009","volume":"17","author":"I Janssen","year":"2017","unstructured":"Janssen\u00a0I, Ryang\u00a0Y\u2011M, Gempt\u00a0J et al (2017) Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine. Spine\u00a0J 17:837\u2013844","journal-title":"Spine J"},{"key":"835_CR19","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1007\/s00198-003-1490-4","volume":"15","author":"O Johnell","year":"2004","unstructured":"Johnell\u00a0O, Kanis\u00a0JA, Oden\u00a0A, Sernbo\u00a0I et\u00a0al (2004) Mortality after osteoporotic fractures. Osteoporos Int 15:38\u201342","journal-title":"Osteoporos Int"},{"key":"835_CR20","doi-asserted-by":"publisher","first-page":"2196","DOI":"10.1007\/s00586-014-3476-7","volume":"23","author":"RA Kueny","year":"2014","unstructured":"Kueny\u00a0RA, Kolb\u00a0JP, Lehmann\u00a0W et\u00a0al (2014) Influence of the screw augmentation technique and a\u00a0diameter increase on pedicle screw fixation in the osteoporotic spine: pullout versus fatigue testing. Eur Spine\u00a0J 23:2196\u20132202","journal-title":"Eur Spine J"},{"key":"835_CR21","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1097\/BRS.0000000000000135","volume":"39","author":"A Lange","year":"2014","unstructured":"Lange\u00a0A, Kasperk\u00a0C, Alvares\u00a0L et\u00a0al (2014) Survival and cost comparison of kyphoplasty and percutaneous vertebroplasty using German claims data. Spine 39:318\u2013326","journal-title":"Spine"},{"key":"835_CR22","doi-asserted-by":"publisher","first-page":"E270","DOI":"10.1097\/BSD.0000000000000204","volume":"30","author":"D Lin","year":"2017","unstructured":"Lin\u00a0D, Hao\u00a0J, Li\u00a0L et\u00a0al (2017) Effect of bone cement volume fraction on adjacent vertebral fractures after unilateral percutaneous kyphoplasty. Clin Spine Surg 30:E270\u2013E275","journal-title":"Clin Spine Surg"},{"key":"835_CR23","doi-asserted-by":"publisher","first-page":"1233","DOI":"10.1007\/s00264-016-3129-z","volume":"40","author":"J Lyu","year":"2016","unstructured":"Lyu\u00a0J, Chen\u00a0K, Tang\u00a0Z et\u00a0al (2016) A comparison of three different surgical procedures in the treatment of type A thoracolumbar fractures: a\u00a0randomized controlled trial. International Orthopaedics (SICOT) 40:1233\u20131238","journal-title":"International Orthopaedics (SICOT)"},{"key":"835_CR24","doi-asserted-by":"publisher","first-page":"103","DOI":"10.3171\/2015.10.SPINE15511","volume":"25","author":"JU Mueller","year":"2016","unstructured":"Mueller\u00a0JU, Baldauf\u00a0J, Marx\u00a0S et\u00a0al (2016) Cement leakage in pedicle screw augmentation: a\u00a0prospective analysis of 98 patients and 474 augmented pedicle screws. J\u00a0Neurosurg Spine 25:103\u2013109","journal-title":"J Neurosurg Spine"},{"key":"835_CR25","doi-asserted-by":"publisher","first-page":"E1210","DOI":"10.1097\/BRS.0b013e318205e3af","volume":"36","author":"PE Par\u00e9","year":"2011","unstructured":"Par\u00e9\u00a0PE, Chappuis\u00a0JL, Rampersaud\u00a0R et\u00a0al (2011) Biomechanical evaluation of a\u00a0novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines. Spine 36:E1210\u2013E1214","journal-title":"Spine"},{"key":"835_CR26","doi-asserted-by":"publisher","first-page":"56","DOI":"10.3171\/spi.2002.96.1.0056","volume":"96","author":"KS Ryu","year":"2002","unstructured":"Ryu\u00a0KS, Park\u00a0CK, Kim\u00a0MC, Kang\u00a0JK (2002) Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures. J\u00a0Neurosurg Spine 96:56\u201361","journal-title":"J Neurosurg Spine"},{"issue":"12","key":"835_CR27","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1007\/s00113-017-0435-x","volume":"120","author":"KJ Schnake","year":"2017","unstructured":"Schnake\u00a0KJ, Bula\u00a0P, Spiegl\u00a0UJ, M\u00fcller\u00a0M, Hartmann\u00a0F, Ullrich\u00a0B, Blattert\u00a0TR (2017) Thorakolumbale Wirbels\u00e4ulenfrakturen beim alten Menschen: Klassifikation und Therapie. Unfallchirurg 120(12):1071\u20131085","journal-title":"Unfallchirurg"},{"key":"835_CR28","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1007\/s00113-019-0658-0","volume":"122","author":"MJ Scheyerer","year":"2019","unstructured":"Scheyerer\u00a0MJ, Ullrich\u00a0B, Osterhoff\u00a0G et al (2019) \u201eHounsfield-Units\u201c als Ma\u00df f\u00fcr die Knochendichte \u2013 Anwendungsm\u00f6glichkeiten in der Wirbels\u00e4ulenchirurgie. Unfallchirurg 122:654\u2013661","journal-title":"Unfallchirurg"},{"key":"835_CR29","doi-asserted-by":"publisher","first-page":"1130","DOI":"10.1007\/s00586-019-05957-8","volume":"28","author":"UJ Spiegl","year":"2019","unstructured":"Spiegl\u00a0UJ, Anemuller\u00a0C, Jarvers\u00a0JS et\u00a0al (2019) Hybrid stabilization of unstable osteoporotic thoracolumbar vertebral body fractures: clinical and radiological outcome after a\u00a0mean of 4 years. Eur Spine\u00a0J 28:1130\u20131137","journal-title":"Eur Spine J"},{"key":"835_CR30","doi-asserted-by":"publisher","first-page":"1407","DOI":"10.1007\/s00402-018-2993-y","volume":"138","author":"UJ Spiegl","year":"2018","unstructured":"Spiegl\u00a0UJ, Devitt\u00a0BM, Kasivskiy\u00a0I (2018) Comparison of combined posterior and anterior spondylodesis versus hybrid stabilization in unstable burst fractures at the thoracolumbar spine in patients between 60 and 70 years of age. Arch Orthop Trauma Surg 138:1407\u20131414","journal-title":"Arch Orthop Trauma Surg"},{"key":"835_CR31","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1007\/s00108-011-2991-4","volume":"53","author":"R Sun","year":"2012","unstructured":"Sun\u00a0R, Maier\u00a0B, Theilmann\u00a0L, Samie\u00a0AA (2012) Vena-cava-inferior-Thrombose bei Patientin mit Non-Hodgkin-Lymphom und stattgefundener Wirbels\u00e4ulenoperation. Internist 53:474\u2013477","journal-title":"Internist"},{"key":"835_CR32","doi-asserted-by":"publisher","first-page":"639","DOI":"10.2106\/00004623-200204000-00023","volume":"84","author":"JD Temple","year":"2002","unstructured":"Temple\u00a0JD, Ludwig\u00a0SC, Ross\u00a0WK et\u00a0al (2002) Catastrophic fat embolism following augmentation of pedicle screws with bone cement: a\u00a0case report. J\u00a0Bone Joint Surg Am 84:639\u2013642","journal-title":"J Bone Joint Surg Am"},{"key":"835_CR33","doi-asserted-by":"publisher","first-page":"150","DOI":"10.3171\/2013.11.SPINE13479","volume":"20","author":"P Vanek","year":"2014","unstructured":"Vanek\u00a0P, Bradac\u00a0O, Konopkova\u00a0R et al (2014) Treatment of thoracolumbar trauma by short-segment percutaneous transpedicular screw instrumentation: prospective comparative study with a\u00a0minimum 2\u2011year follow-up. J\u00a0Neurosurg Spine 20:150\u2013156","journal-title":"J Neurosurg Spine"},{"key":"835_CR34","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1186\/s13018-018-0952-5","volume":"13","author":"B Wang","year":"2018","unstructured":"Wang\u00a0B, Zhao\u00a0CP, Song\u00a0LX, Zhu\u00a0L (2018) Balloon kyphoplasty versus percutaneous vertebroplasty for osteoporotic vertebral compression fracture: a\u00a0meta-analysis and systematic review. J\u00a0Orthop Surg Res 13:264","journal-title":"J Orthop Surg Res"},{"key":"835_CR35","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1007\/s00113-015-0066-z","volume":"118","author":"HJ Wilke","year":"2015","unstructured":"Wilke\u00a0HJ (2015) Biomechanische Aspekte der Augmentation im Bereich der Wirbels\u00e4ule. Unfallchirurg 118:822\u2013830","journal-title":"Unfallchirurg"},{"key":"835_CR36","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1097\/00007632-199106000-00009","volume":"16","author":"R Wittenberg","year":"1991","unstructured":"Wittenberg\u00a0R, Shea\u00a0M, Swartz\u00a0D et\u00a0al (1991) Importance of bone mineral density in instrumented spine fusions. Spine 16:647\u2013652","journal-title":"Spine"},{"key":"835_CR37","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.jocn.2018.10.112","volume":"59","author":"P Yin","year":"2019","unstructured":"Yin\u00a0P, Ji\u00a0Q, Wang\u00a0Y et al (2019) Percutaneous kyphoplasty for osteoporotic vertebral compression fractures via unilateral versus bilateral approach: A meta-analysis. J\u00a0Clin Neurosci 59:146\u2013154","journal-title":"J Clin Neurosci"},{"key":"835_CR38","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1097\/00003086-198602000-00012","volume":"203","author":"MR Zindrick","year":"1986","unstructured":"Zindrick\u00a0MR, Wiltse\u00a0LL, Widell\u00a0EH et\u00a0al (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop 203:112","journal-title":"Clin Orthop"}],"container-title":["Der Unfallchirurg"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00113-020-00835-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00113-020-00835-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00113-020-00835-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,31]],"date-time":"2022-10-31T10:49:34Z","timestamp":1667213374000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00113-020-00835-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,1]]},"references-count":38,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["835"],"URL":"https:\/\/doi.org\/10.1007\/s00113-020-00835-1","relation":{},"ISSN":["0177-5537","1433-044X"],"issn-type":[{"value":"0177-5537","type":"print"},{"value":"1433-044X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,1]]},"assertion":[{"value":"1 July 2020","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}},{"value":"K.J.\u00a0Schnake: Vortragshonorare und Reisekostenerstattung von Fa. Medtronic, Fa. DePuy-Synthes, Fa. Ottobock, AO Spine International; Beratungshonorar von Fa. Swiss Medical Concepts. B.W.\u00a0Ullrich: Vortragshonorar von Fa. B.\u00a0Braun Aesculap. U.J.A.\u00a0Spiegl: Forschungsf\u00f6rderung von Fa. Medacta. K.\u00a0Sprengel: Vortragshonorare und Reisekostenerstattung von Fa. Medtronic, Fa. St\u00f6ckli Medical und AO Spine International; Forschungsf\u00f6rderung von Fa. Medacta, Fa. DePuy-Synthes und Fa. CarboFix. M.J.\u00a0Scheyerer, M.\u00a0Perl, S.\u00a0Gr\u00fcninger, G.\u00a0Osterhoff und S.\u00a0Katscher geben an, dass kein Interessenkonflikt besteht.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}},{"value":"F\u00fcr diesen Beitrag wurden von den Autoren keine Studien an Menschen oder Tieren durchgef\u00fchrt. F\u00fcr die aufgef\u00fchrten Studien gelten die jeweils dort angegebenen ethischen Richtlinien.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}}]}}