{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T16:46:45Z","timestamp":1788540405260,"version":"build-2803163510"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2025,7,12]],"date-time":"2025-07-12T00:00:00Z","timestamp":1752278400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/deed.de"},{"start":{"date-parts":[[2025,7,12]],"date-time":"2025-07-12T00:00:00Z","timestamp":1752278400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/deed.de"}],"funder":[{"DOI":"10.13039\/501100005713","name":"Technische Universit\u00e4t M\u00fcnchen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005713","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Unfallchirurgie"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title>\n          <jats:sec>\n            <jats:title>Operationsziel<\/jats:title>\n            <jats:p>Das Ziel dieses Eingriffes ist es, eine instabile Halswirbels\u00e4ulenverletzung zu stabilisieren.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Indikation<\/jats:title>\n            <jats:p>Typ-B2-Verletzung nach AOSpine-Klassifikation f\u00fcr Verletzungen der subaxialen Halswirbels\u00e4ule und die damit einhergehende Instabilit\u00e4t. Leitlinie und Therapieempfehlungen f\u00fcr diese Verletzung.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Kontraindikationen<\/jats:title>\n            <jats:p>Durch robotisch-assistierte und navigierte Techniken ergeben sich keine speziellen Kontraindikationen.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Operationstechnik<\/jats:title>\n            <jats:p>Durchgef\u00fchrt im 3D-Navigations-Hybrid-OP \u201eRobotic Suite\u201c, bestehend aus Navigationseinheit \u201eCurve Navigation System\u201c, robotischem 3D Cone Beam CT (CBCT) \u201eLoop-X\u201c, robotischem Arm \u201eCirq Arm System\u201c und Wandmonitor \u201eBUZZ\u201c (Fa. Brainlab, M\u00fcnchen, Deutschland).<\/jats:p>\n            <jats:p>Die Erl\u00e4uterung der einzelnen Operationsschritte erfolgt im Video (Englisch), abrufbar auf der Website unter \u201eSupplementary Information\u201c oder \u00fcber den QR-Code.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Operationsschritte<\/jats:title>\n            <jats:p>Pr\u00e4operativ: Planungs-CT und Schraubenplanung.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intraoperativ<\/jats:title>\n            <jats:p>Carbontisch, Bauchlage und Mayfield-Klemme. Dorsaler Zugang. Anbringen der Referenzeinheit. 1.\u00a0CBCT-Scan. Bildfusion. Kontrolle des Fusionsergebnisses. Anfahrt des Roboterarms zum Bohrtrajekt, robotisch assistierte Bohrung. Einbringen des K\u2011Drahtes. Navigiertes Gewindeschneiden und navigierte Schraubenplatzierung. 2.\u00a0CBCT Scan, Kontrolle der Schraubenlage. Zufriedenstellende Schraubenlage, Einbringen der Verbindungsst\u00e4be und des Knochenersatzmaterials, steriler Wundverschluss.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Weiterbehandlung<\/jats:title>\n            <jats:p>Keine Zervikalorthese. Isometrische Krankengymnastik. Schmerztherapie nach Bedarf und WHO-Schema. R\u00f6ntgenkontrolle nach 6\u00a0und 12\u00a0Wochen. Keine Metallentfernung.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Evidenz<\/jats:title>\n            <jats:p>Das dargestellte Videomaterial entstammt einer klinischen Routineoperation. Robotisch-assistierte und navigierte Operationen an der subaxialen Halswirbels\u00e4ule werden mit guten Operationsergebnissen und hoher Genauigkeiten durchgef\u00fchrt.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s00113-025-01599-2","type":"journal-article","created":{"date-parts":[[2025,7,12]],"date-time":"2025-07-12T09:51:39Z","timestamp":1752313899000},"page":"722-726","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Robotisch assistierte und navigierte Pedikelschraubenplatzierung an der subaxialen Halswirbels\u00e4ule","Robotically assisted and navigated pedicle screw placement at the subaxial cervical spine"],"prefix":"10.1007","volume":"128","author":[{"given":"Dominik M.","family":"Haida","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mike","family":"Holl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oybek","family":"Khakimov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Huber-Wagner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,12]]},"reference":[{"key":"1599_CR1","doi-asserted-by":"publisher","first-page":"1941","DOI":"10.1007\/s10143-022-01750-2","volume":"45","author":"MR Soliman","year":"2022","unstructured":"Soliman\u00a0MR, Khan\u00a0S, Ruggiero\u00a0N et\u00a0al (2022) Complications associated with subaxial placement of pedicle screws versus lateral mass screws in the cervical spine: systematic review and meta-analysis comprising 1768 patients and 8636 screws. Neurosurg Rev 45:1941\u20131950","journal-title":"Neurosurg Rev"},{"key":"1599_CR2","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1007\/s00586-025-08753-9","volume":"34","author":"Y Tani","year":"2025","unstructured":"Tani\u00a0Y, Naka\u00a0N, Ono\u00a0N et\u00a0al (2025) A surgeon-controlled mode of robotic assistance with posterolateral approach helps achieve highly medialized cervical pedicle screw placement to avoid vertebral artery injury. Eur Spine\u00a0J 34:1275\u20131283","journal-title":"Eur Spine J"},{"key":"1599_CR3","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1097\/00007632-199705010-00009","volume":"22","author":"EL Jones","year":"1997","unstructured":"Jones\u00a0EL, Heller\u00a0JG, Silcox\u00a0DH et\u00a0al (1997) Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine 22:977\u2013982","journal-title":"Spine"},{"key":"1599_CR4","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1186\/s13018-024-05044-9","volume":"19","author":"DM Haida","year":"2024","unstructured":"Haida\u00a0DM, Mohr\u00a0P, Won\u00a0S\u2011Y et\u00a0al (2024) Hybrid-3D robotic suite in spine and trauma surgery\u2014experiences in 210 patients. J\u00a0Orthop Surg Res 19:565","journal-title":"J Orthop Surg Res"},{"key":"1599_CR5","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1007\/s00586-022-07110-4","volume":"31","author":"S Kisinde","year":"2022","unstructured":"Kisinde\u00a0S, Hu\u00a0X, Hesselbacher\u00a0S et\u00a0al (2022) Robotic-guided placement of cervical pedicle screws: feasibility and accuracy. Eur Spine\u00a0J 31:693\u2013701","journal-title":"Eur Spine J"},{"key":"1599_CR6","doi-asserted-by":"publisher","first-page":"614","DOI":"10.3390\/tomography7040052","volume":"7","author":"A Mahmoud","year":"2021","unstructured":"Mahmoud\u00a0A, Shanmuganathan\u00a0K, Rocos\u00a0B et\u00a0al (2021) Cervical Spine Pedicle Screw Accuracy in Fluoroscopic, Navigated and Template Guided Systems\u2011A Systematic Review. Tomography 7:614\u2013622","journal-title":"Tomography"},{"key":"1599_CR7","doi-asserted-by":"publisher","first-page":"10881","DOI":"10.1038\/s41598-024-60435-6","volume":"14","author":"S Ryu","year":"2024","unstructured":"Ryu\u00a0S, Ha\u00a0BJ, Yoon\u00a0S et\u00a0al (2024) Feasibility and safety report on robotic assistance for cervical pedicle screw fixation: a\u00a0cadaveric study. Sci Rep 14:10881","journal-title":"Sci Rep"},{"key":"1599_CR8","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1186\/s13018-024-05325-3","volume":"20","author":"H Shen","year":"2025","unstructured":"Shen\u00a0H, Zhou\u00a0J, Yu\u00a0L (2025) Cervical pedicle screw fixation with the Tianji orthopedic surgical robot. J\u00a0Orthop Surg Res 20:131","journal-title":"J Orthop Surg Res"},{"key":"1599_CR9","doi-asserted-by":"crossref","unstructured":"Haida\u00a0DM, Khakimov\u00a0O, Huber-Wagner\u00a0S (2025) Robotisch assistierte und minimal-invasive Pedikelschraubenplatzierung an der Lendenwirbels\u00e4ule. Die Unfallchirurgie","DOI":"10.1007\/s00113-025-01596-5"},{"key":"1599_CR10","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1007\/s00068-024-02759-6","volume":"51","author":"R Hartensuer","year":"2025","unstructured":"Hartensuer\u00a0R, Weise\u00a0A, Breuing\u00a0J et\u00a0al (2025) Initial surgical management of spinal injuries in patients with multiple and\/or severe injuries\u2014the 2022 update of the German clinical practice guideline. Eur J Trauma Emerg Surg 51:70","journal-title":"Eur J Trauma Emerg Surg"},{"key":"1599_CR11","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1055\/s-0042-105957","volume":"154","author":"G Schiffer","year":"2016","unstructured":"Schiffer\u00a0G, Goldmann\u00a0S, Faymonville\u00a0C et\u00a0al (2016) 3\u2011D-navigierte Pedikelschrauben der Halswirbels\u00e4ule \u2013 Erfahrungen und Komplikationsanalyse. Z\u00a0Orthop Unfall 154:483\u2013487","journal-title":"Z Orthop Unfall"},{"key":"1599_CR12","doi-asserted-by":"publisher","first-page":"2173","DOI":"10.1007\/s00586-015-3831-3","volume":"25","author":"AR Vaccaro","year":"2016","unstructured":"Vaccaro\u00a0AR, Koerner\u00a0JD, Radcliff\u00a0KE et\u00a0al (2016) AOSpine subaxial cervical spine injury classification system. Eur Spine\u00a0J 25:2173\u20132184","journal-title":"Eur Spine J"},{"key":"1599_CR13","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1007\/s00113-021-01087-3","volume":"124","author":"P Schleicher","year":"2021","unstructured":"Schleicher\u00a0P, Scholz\u00a0M, Castein\u00a0J et\u00a0al (2021) Leitliniengerechte Therapie von Verletzungen der subaxialen Halswirbels\u00e4ule. Unfallchirurg 124:931\u2013944","journal-title":"Unfallchirurg"},{"key":"1599_CR14","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1007\/s00113-024-01507-0","volume":"128","author":"C Arras","year":"2025","unstructured":"Arras\u00a0C, Kylies\u00a0J, Viezens\u00a0L et\u00a0al (2025) Konservative Therapie von Verletzungen der Halswirbels\u00e4ule. Die Unfallchirurgie 128:96\u2013102","journal-title":"Die Unfallchirurgie"},{"key":"1599_CR15","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1055\/s-0043-110855","volume":"155","author":"P Schleicher","year":"2017","unstructured":"Schleicher\u00a0P, Scholz\u00a0M, Kandziora\u00a0F et\u00a0al (2017) Subaxial Cervical Spine Injuries: Treatment Recommendations of the German Orthopedic and Trauma Society. Z\u00a0Orthop Unfall 155:556\u2013566","journal-title":"Z Orthop Unfall"},{"key":"1599_CR16","doi-asserted-by":"publisher","first-page":"66","DOI":"10.3171\/2022.7.SPINE22473","volume":"38","author":"RS Beyer","year":"2023","unstructured":"Beyer\u00a0RS, Nguyen\u00a0A, Brown\u00a0NJ et\u00a0al (2023) Spinal robotics in cervical spine surgery: a\u00a0systematic review with key concepts and technical considerations. J\u00a0Neurosurg Spine 38:66\u201374","journal-title":"J Neurosurg Spine"},{"key":"1599_CR17","doi-asserted-by":"publisher","first-page":"E13","DOI":"10.3171\/2024.9.FOCUS24431","volume":"57","author":"Y Yamamoto","year":"2024","unstructured":"Yamamoto\u00a0Y, Fujishiro\u00a0T, Adachi\u00a0F et\u00a0al (2024) Accuracy of cervical pedicle screw placement with a\u00a0robotic guidance system via the open midline approach. Neurosurg Focus 57:E13","journal-title":"Neurosurg Focus"},{"key":"1599_CR18","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1007\/s00113-024-01513-2","volume":"128","author":"DM Haida","year":"2025","unstructured":"Haida\u00a0DM, M\u00f6hlig\u00a0T, Huber-Wagner\u00a0S (2025) Navigierte und minimalinvasive Schraubenosteosynthese einer Talusfraktur. Die Unfallchirurgie 128:64\u201368","journal-title":"Die Unfallchirurgie"},{"key":"1599_CR19","doi-asserted-by":"crossref","unstructured":"Haida DM, Wagenblast I, Huber-Wagner S (2025) Robotisch assistierte Schraubenplatzierung einer Kriechschraube und einer SI-S1-Schraube. Die Unfallchirurgie","DOI":"10.1007\/s00113-025-01580-z"},{"key":"1599_CR20","doi-asserted-by":"publisher","first-page":"329","DOI":"10.14245\/ns.2244952.476","volume":"20","author":"LP Zhou","year":"2023","unstructured":"Zhou\u00a0LP, Zhang\u00a0ZG, Li\u00a0D et\u00a0al (2023) Robotics in Cervical Spine Surgery: Feasibility and Safety of Posterior Screw Placement. Neurospine 20:329\u2013339","journal-title":"Neurospine"}],"updated-by":[{"DOI":"10.1007\/s00113-025-01631-5","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000}}],"container-title":["Die Unfallchirurgie"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00113-025-01599-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00113-025-01599-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00113-025-01599-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,7]],"date-time":"2025-09-07T06:20:20Z","timestamp":1757226020000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00113-025-01599-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,12]]},"references-count":20,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["1599"],"URL":"https:\/\/doi.org\/10.1007\/s00113-025-01599-2","relation":{"erratum":[{"id-type":"doi","id":"10.1007\/s00113-025-01631-5","asserted-by":"object"}]},"ISSN":["2731-7021","2731-703X"],"issn-type":[{"value":"2731-7021","type":"print"},{"value":"2731-703X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,12]]},"assertion":[{"value":"23 May 2025","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 July 2025","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2025","order":3,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":4,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Der zun\u00e4chst ver\u00f6ffentlichte Beitrag wurde \u00fcberarbeitet. In diesem Artikel wurde der Name von dem Autor Dominik M. Haida f\u00e4lschlicherweise als Dominik Marcel Haida angegeben. Der Originalbeitrag wurde korrigiert.","order":5,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 August 2025","order":6,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Erratum","order":7,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Zu diesem Beitrag wurde ein Erratum ver\u00f6ffentlicht:","order":8,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s00113-025-01631-5","URL":"https:\/\/doi.org\/10.1007\/s00113-025-01631-5","order":9,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}},{"value":"D.M.\u00a0Haida, M.\u00a0Holl und O.\u00a0Khakimov geben an, dass kein Interessenkonflikt besteht. S.\u00a0Huber-Wagner erhielt von Brainlab Reisekostenerstattungen f\u00fcr Vortr\u00e4ge.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}},{"value":"F\u00fcr diesen Beitrag wurden von den Autor\/-innen keine Studien an Menschen oder Tieren durchgef\u00fchrt. F\u00fcr die aufgef\u00fchrten Studien gelten die jeweils dort angegebenen ethischen Richtlinien. Alle Patienten, die \u00fcber Bildmaterial oder anderweitige Angaben innerhalb des Manuskripts zu identifizieren sind, haben hierzu ihre schriftliche Einwilligung gegeben.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}}]}}