{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T06:22:16Z","timestamp":1768371736188,"version":"3.49.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"S1","license":[{"start":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T00:00:00Z","timestamp":1721174400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T00:00:00Z","timestamp":1721174400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiologie"],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>A\u00a0recent innovation in computed tomography (CT) imaging has been the introduction of photon-counting detector CT (PCD-CT) systems, which are able to register the number and the energy level of incoming x\u2011ray photons and have smaller detector elements compared with conventional CT scanners that operate with energy-integrating detectors (EID-CT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>The study aimed to evaluate the potential benefits of a\u00a0novel, non-CE certified PCD-CT in detecting myeloma-associated osteolytic bone lesions (OL) compared with a\u00a0state-of-the-art EID-CT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>Nine patients with multiple myeloma stage\u00a0III (according to Durie and Salmon) underwent magnetic resonance imaging (MRI), EID-CT, and PCD-CT of the lower lumbar spine and pelvis. The PCD-CT and EID-CT images of all myeloma lesions that were visible in clinical MRI scans were reviewed by three radiologists for corresponding OL. Additionally, the visualization of destructions to cancellous or cortical bone, and trabecular structures, was compared between PCD-CT and EID-CT.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Readers detected 21% more OL in PCD-CT than in EID-CT images (138 vs. 109;\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&lt;\u20090.0001). The sensitivity advantage of PCD-CT in lesion detection increased with decreasing lesion size. The visualization quality of cancellous and cortical destructions as well as of trabecular structures was rated higher by all three readers in PCD-CT images (mean image quality improvements for PCD-CT over EID-CT were +0.45 for cancellous and +0.13 for cortical destructions).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>For myeloma-associated OL, PCD-CT demonstrated significantly higher sensitivity, especially with small size. Visualization of bone tissue and lesions was considered significantly better in PCD-CT than in EID-CT. This implies that PCD-CT scanners could potentially be used in the early detection of myeloma-associated bone lesions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Graphic abstract<\/jats:title>\n                  <\/jats:sec>","DOI":"10.1007\/s00117-024-01344-7","type":"journal-article","created":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T14:02:36Z","timestamp":1721224956000},"page":"24-31","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Detection of myeloma-associated osteolytic bone lesions with energy-integrating and photon-counting detector CT","Erkennung myelomassoziierter osteolytischer Knochenl\u00e4sionen mit energieintegrierender und photonenz\u00e4hlender Detektor-Computertomographie"],"prefix":"10.1007","volume":"64","author":[{"given":"Martin","family":"Gr\u00f6zinger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Markus","family":"Wennmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Sawall","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eckhard","family":"Wehrse","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sam","family":"Sedaghat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Neelsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fabian","family":"Bauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hartmut","family":"Goldschmidt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vivienn","family":"Weru","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian H.","family":"Ziener","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annette","family":"Kopp-Schneider","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heinz-Peter","family":"Schlemmer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lukas T.","family":"Rotkopf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,7,17]]},"reference":[{"key":"1344_CR1","doi-asserted-by":"publisher","first-page":"e538","DOI":"10.1016\/S1470-2045(14)70442-5","volume":"15","author":"SV Rajkumar","year":"2014","unstructured":"Rajkumar\u00a0SV et\u00a0al (2014) International Myeloma Working Group updated criteria for the diagnosis of multiple myeloma. Lancet Oncol 15:e538\u201348","journal-title":"Lancet Oncol"},{"key":"1344_CR2","doi-asserted-by":"crossref","unstructured":"Hillengass, J. et\u00a0al. S.\u00a02019. International myeloma working group consensus recommendations on imaging in monoclonal plasma cell disorders. Lancet Oncol., 20, e302\u2013e312.","DOI":"10.1016\/S1470-2045(19)30309-2"},{"key":"1344_CR3","doi-asserted-by":"crossref","unstructured":"Caers, J. et\u00a0al. M. 2018. European Myeloma Network recommendations on tools for the diagnosis and monitoring of multiple myeloma: what to use and when. Haematologica, 103, 1772\u20131784.","DOI":"10.3324\/haematol.2018.189159"},{"key":"1344_CR4","doi-asserted-by":"crossref","unstructured":"Sive, J., Cuthill, K., Hunter, H., Kazmi, M., Pratt, G., Smith, D. & British Society of, H. 2021. Guidelines on the diagnosis, investigation and initial treatment of myeloma: a\u00a0British Society for Haematology\/UK Myeloma Forum Guideline. Br J Haematol., 193, 245\u2013268.","DOI":"10.1111\/bjh.17410"},{"key":"1344_CR5","doi-asserted-by":"crossref","unstructured":"Chantry A K. M., Barrington S, Goh V, Mulholland N, Streetly M, Lai M, Pratt G. 2017. Guidelines for the use of imaging in the management ofpatients with myeloma. Br J Haematol 178:380\u2013393","DOI":"10.1111\/bjh.14827"},{"key":"1344_CR6","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1038\/leu.2013.244","volume":"28","author":"J Hillengass","year":"2014","unstructured":"Hillengass\u00a0J, Weber\u00a0MA, Kilk\u00a0K, Listl\u00a0K, Wagner-Gund\u00a0B, Hillengass\u00a0M, Hielscher\u00a0T, Farid\u00a0A, Neben\u00a0K, Delorme\u00a0S, Landgren\u00a0O, Goldschmidt\u00a0H (2014) Prognostic significance of whole-body MRI in patients with monoclonal gammopathy of undetermined significance. Leukemia 28:174\u2013178","journal-title":"Leukemia"},{"key":"1344_CR7","doi-asserted-by":"crossref","unstructured":"Kastritis E, M. L., Terpos E, Koutoulidis V, Dimopoulos MA. 2014. The prognostic importance of the presence of more than one focal lesion in spine MRI of patients with asymptomatic (smoldering) multiple myeloma. Leukemia. 28(12):2402\u20133.","DOI":"10.1038\/leu.2014.230"},{"key":"1344_CR8","doi-asserted-by":"crossref","unstructured":"Dhodapkar, M. V., Sexton, R., Waheed, S., Usmani, S., Papanikolaou, X., Nair, B., Petty, N., Shaughnessy, J. D., JR., Hoering, A., Crowley, J., Orlowski, R. Z. & Barlogie, B. 2014. Clinical, genomic, and imaging predictors of myeloma progression from asymptomatic monoclonal gammopathies. Blood, 123, 78\u201385.","DOI":"10.1182\/blood-2013-07-515239"},{"key":"1344_CR9","doi-asserted-by":"crossref","unstructured":"Zamagni E, N. C. et\u00a0al. 2016. 18F-FDG PET\/CT focal, but not osteolytic, lesions predict the progression of smoldering myeloma to active disease. Leukemia., 30(2):417\u201322.","DOI":"10.1038\/leu.2015.291"},{"issue":"1","key":"1344_CR10","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1111\/bjh.18232","volume":"199","author":"M Wennmann","year":"2022","unstructured":"Wennmann\u00a0M, Goldschmidt\u00a0H, Mosebach\u00a0J, Hielscher\u00a0T, B\u00e4uerle\u00a0T, Delorme\u00a0S, Hillengass\u00a0J (2022) Whole-body magnetic resonance imaging plus serological follow-up for early identification of progression in smouldering myeloma patients to prevent development of end-organ damage. Br J Haematol 199(1):65\u201375","journal-title":"Br J Haematol"},{"key":"1344_CR11","doi-asserted-by":"publisher","first-page":"21","DOI":"10.4065\/78.1.21","volume":"78","author":"RA Kyle","year":"2003","unstructured":"Kyle\u00a0RA, Gertz\u00a0MA, Witzig\u00a0TE, Lust\u00a0JA, Lacy\u00a0MQ, Dispenzieri\u00a0A, Fonseca\u00a0R, Rajkumar\u00a0SV, Offord\u00a0JR, Larson\u00a0DR, Plevak\u00a0ME, Therneau\u00a0TM, Greipp\u00a0PR (2003) Review of 1027 patients with newly diagnosed multiple myeloma. Mayo Clin Proc 78:21\u201333","journal-title":"Mayo Clin Proc"},{"key":"1344_CR12","doi-asserted-by":"crossref","unstructured":"Zamagni, E., Cavo, M., Fakhri, B., VIJ, R., Roodman, D. Roodman, D. ET AL. 2018. Bones in Multiple Myeloma: Imaging and Therapy. Am Soc Clin Oncol Educ Book., 38, 638\u2013646.","DOI":"10.1200\/EDBK_205583"},{"key":"1344_CR13","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","volume":"289","author":"MJ Willemink","year":"2018","unstructured":"Willemink\u00a0MJ, Persson\u00a0M, Pourmorteza\u00a0A, Pelc\u00a0NJ, Fleischmann\u00a0D (2018) Photon-counting CT: Technical Principles and Clinical Prospects. Radiology 289:293\u2013312","journal-title":"Radiology"},{"key":"1344_CR14","doi-asserted-by":"publisher","first-page":"100901","DOI":"10.1118\/1.4820371","volume":"40","author":"K Taguchi","year":"2013","unstructured":"Taguchi\u00a0K, Iwanczyk\u00a0JS (2013) Vision\u00a020\/20: Single photon counting x\u2011ray detectors in medical imaging. Med Phys 40:100901","journal-title":"Med Phys"},{"key":"1344_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00117-021-00812-8","volume":"61","author":"E Wehrse","year":"2021","unstructured":"Wehrse\u00a0E, Klein\u00a0L, Rotkopf\u00a0LT, Wagner\u00a0WL, Uhrig\u00a0M, Heussel\u00a0CP, Ziener\u00a0CH, Delorme\u00a0S, Heinze\u00a0S, Kachelriess\u00a0M, Schlemmer\u00a0HP, Sawall\u00a0S (2021a) Photon-counting detectors in computed tomography: from quantum physics to clinical practice. Radiologe 61:1\u201310","journal-title":"Radiologe"},{"key":"1344_CR16","doi-asserted-by":"crossref","unstructured":"Thomsen FSL, H. S., Niehoff JH, Pe\u00f1a JA, Borggrefe J. 2022. Effective Spatial Resolution of Photon Counting CT for Imaging of Trabecular Structures is Superior to Conventional Clinical CT and Similar to High Resolution Peripheral CT. Investigative Radiology, 57(9), 620\u2013626.","DOI":"10.1097\/RLI.0000000000000873"},{"key":"1344_CR17","doi-asserted-by":"crossref","unstructured":"Gutjahr, R., Halaweish, A.F., Yu, Z. C., Leng, S., Yu, L. F., LI, Z.\u202fB., Jorgensen, S. M., Ritman, E. L., Kappler, S. & McCollough, C. H. 2016. Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies. Investigative Radiology, 51, 421\u2013429.","DOI":"10.1097\/RLI.0000000000000251"},{"issue":"24","key":"1344_CR18","doi-asserted-by":"publisher","first-page":"245003","DOI":"10.1088\/1361-6560\/ab55bf","volume":"64","author":"LQ Ren","year":"2019","unstructured":"Ren\u00a0LQ, Rajendran\u00a0K, McCollough\u00a0CH, Yu\u00a0LF (2019) Radiation dose efficiency of multi-energy photon-counting-detector CT for dual-contrast imaging. Phys Med Biol 64(24):245003","journal-title":"Phys Med Biol"},{"key":"1344_CR19","doi-asserted-by":"publisher","first-page":"1595","DOI":"10.1088\/0031-9155\/57\/6\/1595","volume":"57","author":"PM Shikhaliev","year":"2012","unstructured":"Shikhaliev\u00a0PM (2012) Photon counting spectral CT: improved material decomposition with K\u2011edge-filtered x\u2011rays. Phys Med Biol 57:1595\u20131615","journal-title":"Phys Med Biol"},{"key":"1344_CR20","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1148\/radiol.212579","volume":"303","author":"K Rajendran","year":"2022","unstructured":"Rajendran\u00a0K, Petersilka\u00a0M, Henning\u00a0A, Shanblatt\u00a0ER, Schmidt\u00a0B, Flohr\u00a0TG, Ferrero\u00a0A, Baffour\u00a0F, Diehn\u00a0FE, Yu\u00a0L, Rajiah\u00a0P, Fletcher\u00a0JG, Leng\u00a0S, McCollough\u00a0CH (2022) First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology 303:130\u2013138","journal-title":"Radiology"},{"issue":"4","key":"1344_CR21","doi-asserted-by":"publisher","first-page":"2415","DOI":"10.1007\/s00330-022-09225-0","volume":"33","author":"MT Winkelmann","year":"2022","unstructured":"Winkelmann\u00a0MT, Hagen\u00a0F, Le-Yannou\u00a0L, Weiss\u00a0J, Riffel\u00a0P, Gutjahr\u00a0R, Faby\u00a0S, Nikolau\u00a0K, Horger\u00a0M (2022) Myeloma bone disease imaging on a\u00a01st-generation clinical photon-counting detector CT vs. 2nd-generation dual-source dual-energy CT. Eur Radiol 33(4):2415\u20132425","journal-title":"Eur Radiol"},{"key":"1344_CR22","doi-asserted-by":"crossref","unstructured":"Baffour FL, Guber NR, Ferrero A, Rajendran K, Glazebrook KN, Larson NB, Kumar S, Cook JM, Leng S, Shanblatt ER, Collough MC, Fletcher CH J.G. 2022. Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma. Radiology 306(1):229\u2013236","DOI":"10.1148\/radiol.220311"},{"key":"1344_CR23","doi-asserted-by":"crossref","unstructured":"Schwartz, F.R., Vinson, E.N., Spritzer, C.E., Colglazier, R., Samei, E., French, R.J., Said, N., Waldman, L., MC Crum, E. 2022. Prospective Multireader Evaluation of Photon-counting CT for Multiple Myeloma Screening. Radiol. Imaging Cancer, 4(6), e220073.","DOI":"10.1148\/rycan.220073"},{"key":"1344_CR24","doi-asserted-by":"crossref","unstructured":"Yushkevich, P., Piven, J., Hazlett, H.C., Smith R.G., Ho, S., Gee, J.C.,Gerig, G. 2006. User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability. Neuroimage, Jul 1;31(3):1116\u201328.","DOI":"10.1016\/j.neuroimage.2006.01.015"},{"key":"1344_CR25","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.2214\/AJR.07.2635","volume":"190","author":"A Baur-Melnyk","year":"2008","unstructured":"Baur-Melnyk\u00a0A, Buhmann\u00a0S, Becker\u00a0C et\u00a0al (2008) Whole-body MRI versus whole-body MDCT for staging of multiple myeloma. AJR Am J Roentgenol 190:1097\u20131104","journal-title":"AJR Am J Roentgenol"},{"key":"1344_CR26","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1159\/000531461","volume":"146","author":"J Cook","year":"2023","unstructured":"Cook\u00a0J, Rajendran\u00a0K, Ferrero\u00a0A et\u00a0al (2023) Photon Counting Detector Computed Tomography: A\u00a0New Frontier of Myeloma Bone Disease Evaluation. Acta Haematol 146:419\u2013423","journal-title":"Acta Haematol"},{"key":"1344_CR27","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.3348\/kjr.2023.0211","volume":"24","author":"A Rau","year":"2023","unstructured":"Rau\u00a0A, Neubauer\u00a0J, Taleb\u00a0L et\u00a0al (2023) Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma. Korean J Radiol 24:1006\u20131016","journal-title":"Korean J Radiol"},{"key":"1344_CR28","doi-asserted-by":"crossref","unstructured":"Bartlett, D. J., Koo, C. W., Bartholmai, B. J., Rajendran, K., Weaver, J. M., Halaweish, A.F., Leng, S., McCollough, C. H. & Fletcher, J. G. 2019. High-Resolution Chest Computed Tomography Imaging of the Lungs: Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography. Invest Radiol., 54, 129\u2013137.","DOI":"10.1097\/RLI.0000000000000524"}],"updated-by":[{"DOI":"10.1007\/s00117-025-01559-2","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T00:00:00Z","timestamp":1768262400000}}],"container-title":["Die Radiologie"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00117-024-01344-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00117-024-01344-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00117-024-01344-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T23:02:22Z","timestamp":1768345342000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00117-024-01344-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,17]]},"references-count":28,"journal-issue":{"issue":"S1","published-print":{"date-parts":[[2024,11]]}},"alternative-id":["1344"],"URL":"https:\/\/doi.org\/10.1007\/s00117-024-01344-7","relation":{},"ISSN":["2731-7048","2731-7056"],"issn-type":[{"value":"2731-7048","type":"print"},{"value":"2731-7056","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,17]]},"assertion":[{"value":"23 April 2024","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 July 2024","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 December 2025","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This article was originally published under the subscription model but it is now published under an Open Access license.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 January 2026","order":7,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Erratum","order":8,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"An Erratum to this paper has been published:","order":9,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s00117-025-01559-2","URL":"https:\/\/doi.org\/10.1007\/s00117-025-01559-2","order":10,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"M.\u00a0Gr\u00f6zinger, M.\u00a0Wennmann, S.\u00a0Sawall, E.\u00a0Wehrse, S.\u00a0Sedaghat, C.\u00a0Neelsen, F.\u00a0Bauer, H.\u00a0Goldschmidt, V.\u00a0Weru, C.\u00a0Ziener, A.\u00a0Kopp-Schneider, H.P.\u00a0Schlemmer and L.T.\u00a0Rotkopf declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants or on human tissue were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1975 Helsinki declaration and its later amendments or comparable ethical standards. Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The supplement containing this article is not sponsored by industry.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}