{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T16:28:16Z","timestamp":1776702496933,"version":"3.51.2"},"reference-count":62,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T00:00:00Z","timestamp":1775520000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T00:00:00Z","timestamp":1775520000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiologie"],"published-print":{"date-parts":[[2026,5]]},"DOI":"10.1007\/s00117-026-01601-x","type":"journal-article","created":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T13:27:08Z","timestamp":1775568428000},"page":"397-412","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["MRT-Sicherheit","MRI safety"],"prefix":"10.1007","volume":"66","author":[{"given":"Michael","family":"Bock","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ute","family":"Ludwig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johannes","family":"Fischer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wilfried","family":"Reichardt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,4,7]]},"reference":[{"issue":"2","key":"1601_CR1","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1148\/radiol.2018172453","volume":"288","author":"S Suntharalingam","year":"2018","unstructured":"Suntharalingam\u00a0S, Mladenov\u00a0E, Sarabhai\u00a0T, Wetter\u00a0A, Kraff\u00a0O, Quick\u00a0HH, Nassenstein\u00a0K et\u00a0al (2018) Abdominopelvic 1.5\u2011T and 3.0\u2011T MR Imaging in Healthy Volunteers: Relationship to Formation of DNA Double-Strand Breaks. Radiology 288(2):529\u2013535. https:\/\/doi.org\/10.1148\/radiol.2018172453","journal-title":"Radiology"},{"issue":"3","key":"1601_CR2","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1007\/s00330-017-5056-9","volume":"28","author":"M Fasshauer","year":"2018","unstructured":"Fasshauer\u00a0M, Kr\u00fcwel\u00a0T, Zapf\u00a0A, Stahnke\u00a0VC, Rave-Fr\u00e4nk\u00a0M, Staab\u00a0W, Lotz\u00a0J et\u00a0al (2018) Absence of DNA double-strand breaks in human peripheral blood mononuclear cells after 3 Tesla magnetic resonance imaging assessed by \u03b3H2AX flow cytometry. European Radiology 28(3):1149\u20131156. https:\/\/doi.org\/10.1007\/s00330-017-5056-9","journal-title":"European Radiology"},{"issue":"3","key":"1601_CR3","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1148\/radiol.2016160794","volume":"282","author":"A Reddig","year":"2017","unstructured":"Reddig\u00a0A, Fatahi\u00a0M, Roggenbuck\u00a0D, Ricke\u00a0J, Reinhold\u00a0D, Speck\u00a0O, Friebe\u00a0B (2017) Impact of in Vivo High-Field-Strength and Ultra-High-Field-Strength MR Imaging on DNA Double-Strand-Break Formation in Human Lymphocytes. Radiology 282(3):782\u2013789. https:\/\/doi.org\/10.1148\/radiol.2016160794","journal-title":"Radiology"},{"key":"1601_CR4","unstructured":"Regulation (EU) 2017\/745 of the European Parliament and of the Council of 5\u00a0April 2017 on medical devices, amending Directive 2001\/83\/EC, Regulation (EC) No 178\/2002 and Regulation (EC) No 1223\/2009 and repealing Council Directives 90\/385\/EEC and 93\/42\/EEC (Text with EEA relevance. ). , 117 OJ L (2017)."},{"key":"1601_CR5","unstructured":"(2020) Medizinprodukterecht-Durchf\u00fchrungsgesetz vom 28.\u00a0April 2020 (BGBl.\u00a0I S.\u00a0960), das zuletzt durch Artikel\u00a03 des Gesetzes vom 23.\u00a0Oktober 2024 (BGBl. 2024 I Nr. 324) ge\u00e4ndert worden ist."},{"key":"1601_CR6","unstructured":"Medizinprodukte-Betreiberverordnung vom 14.\u00a0Februar 2025 (BGBl. 2025 I Nr.\u00a038), die zuletzt durch Artikel\u00a01 der Verordnung vom 31.\u00a0Oktober 2025 (BGBl. 2025 I Nr. 263) ge\u00e4ndert worden ist (2025)."},{"key":"#cr-split#-1601_CR7.1","unstructured":"European Parliament and of the Council (2013on) Directive 2013\/35\/EU of the European Parliament and of the Council of 26 June 2013 on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields) (20th individual Directive within the meaning of Article 16"},{"key":"#cr-split#-1601_CR7.2","unstructured":"(1) of Directive 89\/391\/EEC) and repealing Directive 2004\/40\/EC."},{"key":"1601_CR8","unstructured":"Arbeitsschutzverordnung zu elektromagnetischen Feldern vom 15.\u00a0November 2016 (BGBl.\u00a0I S.\u00a02531), die durch Artikel\u00a02 der Verordnung vom 30.\u00a0April 2019 (BGBl.\u00a0I S.\u00a0554) ge\u00e4ndert worden ist (2016)."},{"key":"1601_CR9","unstructured":"Technische Regel zur Arbeitsschutzverordnung zu elektromagnetischen Feldern - TREMF MR Magnetresonanzverfahren. (2023)"},{"key":"1601_CR10","unstructured":"DGUV Vorschrift 15 - Elektromagnetische Felder (2001) DGUV Vorschrift 15 - Elektromagnetische Felder."},{"key":"1601_CR11","unstructured":"DGUV Vorschrift 15 tritt am 1. Februar 2026 au\u00dfer Kraft. bgetem.de - BG ETEM. https:\/\/www.bgetem.de\/presse-aktuelles\/aenderungen-im-regelwerk\/dguv-vorschrift-15-tritt-am-1-februar-2026-ausser-kraft (Created 26.1.2026). Accessed 11.2.2026"},{"issue":"2","key":"1601_CR12","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1007\/s00330-024-10999-8","volume":"35","author":"LE Nordin","year":"2025","unstructured":"Nordin\u00a0LE, \u00c5berg\u00a0K, Kihlberg\u00a0J, Owman\u00a0T, Hansson\u00a0B, Bj\u00f6rkman-Burtscher\u00a0IM, Lundberg\u00a0P et\u00a0al (2025) ESR Essentials: basic physics of MR safety\u2014practice recommendations by the European Society for Magnetic Resonance in Medicine and Biology. European Radiology 35(2):572\u2013579. https:\/\/doi.org\/10.1007\/s00330-024-10999-8","journal-title":"European Radiology"},{"issue":"4","key":"1601_CR13","doi-asserted-by":"publisher","first-page":"1785","DOI":"10.1007\/s00330-024-11055-1","volume":"35","author":"F Santini","year":"2025","unstructured":"Santini\u00a0F, Pansini\u00a0M, Deligianni\u00a0X, Caligiuri\u00a0ME, Oei\u00a0EHG (2025) ESR Essentials: advanced MR safety in vulnerable patients\u2014practice recommendations by the European Society for Magnetic Resonance in Medicine and Biology. European Radiology 35(4):1785\u20131793. https:\/\/doi.org\/10.1007\/s00330-024-11055-1","journal-title":"European Radiology"},{"issue":"1","key":"1601_CR14","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1002\/jmri.25761","volume":"47","author":"LP Panych","year":"2018","unstructured":"Panych\u00a0LP, Madore\u00a0B (2018) The physics of MRI safety. Journal of Magnetic Resonance Imaging 47(1):28\u201343. https:\/\/doi.org\/10.1002\/jmri.25761","journal-title":"Journal of Magnetic Resonance Imaging"},{"key":"1601_CR15","volume-title":"MRI Bioeffects, Safety, and Patient Management","author":"FG Shellock","year":"2022","unstructured":"Shellock\u00a0FG, Crues\u00a0JV III, Karacozoff\u00a0AM (2022) MRI Bioeffects, Safety, and Patient Management, 2\u00a0edn.","edition":"2"},{"key":"1601_CR16","unstructured":"American College of Radiology (2024) ACR Manual on MR Safety."},{"issue":"1","key":"1601_CR17","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.241405","volume":"315","author":"I Pedrosa","year":"2025","unstructured":"Pedrosa\u00a0I, Altman\u00a0DA, Dillman\u00a0JR, Hoff\u00a0MN, McKinney\u00a0AM, Reeder\u00a0SB, Watson\u00a0RE et\u00a0al (2025) American College of Radiology Manual on MR Safety: 2024 Update and Revisions. Radiology 315(1):e241405. https:\/\/doi.org\/10.1148\/radiol.241405","journal-title":"Radiology"},{"key":"1601_CR18","volume-title":"Besondere Festlegungen f\u00fcr die Sicherheit von Magnetresonanzger\u00e4ten f\u00fcr die medizinische Diagnostik","author":"DIN EN IEC 60601-2-33 VDE 0750-2-33:2025-07","year":"2025","unstructured":"DIN EN IEC 60601-2-33 VDE 0750-2-33:2025-07 (2025) Besondere Festlegungen f\u00fcr die Sicherheit von Magnetresonanzger\u00e4ten f\u00fcr die medizinische Diagnostik. VDE Verlag"},{"key":"1601_CR19","volume-title":"DIN 6876:2019-05 Betrieb von medizinischen Magnetresonanzsystemen","author":"DIN 6876:2019-05 Betrieb von medizinischen Magnetresonanzsystemen","year":"2019","unstructured":"DIN 6876:2019-05 Betrieb von medizinischen Magnetresonanzsystemen (2019) DIN 6876:2019-05 Betrieb von medizinischen Magnetresonanzsystemen"},{"key":"1601_CR20","unstructured":"DIN\u00a06876 Beiblatt 1:2023 DE - Betrieb von medizinischen Magnetresonanzsystemen; Beiblatt 1: Allgemeine Erkl\u00e4rungen und Begr\u00fcndungen. (2023, October)."},{"issue":"5","key":"1601_CR21","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1097\/HP.0000000000001210","volume":"118","author":"International Commission on Non-Ionizing Radiation Protection (ICNIRP)","year":"2020","unstructured":"International Commission on Non-Ionizing Radiation Protection (ICNIRP) (2020) Guidelines for Limiting Exposure to Electromagnetic Fields (100\u202fkHz to 300\u202fGHz). Health Physics 118(5):483\u2013524. https:\/\/doi.org\/10.1097\/HP.0000000000001210","journal-title":"Health Physics"},{"issue":"6","key":"1601_CR22","doi-asserted-by":"publisher","first-page":"1646","DOI":"10.1002\/jmri.27194","volume":"53","author":"L Winter","year":"2021","unstructured":"Winter\u00a0L, Seifert\u00a0F, Zilberti\u00a0L, Murbach\u00a0M, Ittermann\u00a0B (2021) MRI-Related Heating of Implants and Devices: A Review. Journal of Magnetic Resonance Imaging 53(6):1646\u20131665. https:\/\/doi.org\/10.1002\/jmri.27194","journal-title":"Journal of Magnetic Resonance Imaging"},{"issue":"5","key":"1601_CR23","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1056\/NEJMc1811197","volume":"380","author":"MF Callaghan","year":"2019","unstructured":"Callaghan\u00a0MF, Negus\u00a0C, Leff\u00a0AP, Creasey\u00a0M, Burns\u00a0S, Glensman\u00a0J, Weiskopf\u00a0N et\u00a0al (2019) Safety of Tattoos in Persons Undergoing MRI. New England Journal of Medicine 380(5):495\u2013496. https:\/\/doi.org\/10.1056\/NEJMc1811197","journal-title":"New England Journal of Medicine"},{"issue":"6","key":"1601_CR24","doi-asserted-by":"publisher","first-page":"1795","DOI":"10.2214\/ajr.174.6.1741795","volume":"174","author":"WA Wagle","year":"2000","unstructured":"Wagle\u00a0WA, Smith\u00a0M (2000) Tattoo-Induced Skin Burn During MR Imaging. American Journal of Roentgenology 174(6):1795\u20131795. https:\/\/doi.org\/10.2214\/ajr.174.6.1741795","journal-title":"American Journal of Roentgenology"},{"issue":"1","key":"1601_CR25","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.hrthm.2010.10.002","volume":"8","author":"BL Wilkoff","year":"2011","unstructured":"Wilkoff\u00a0BL, Bello\u00a0D, Taborsky\u00a0M, Vymazal\u00a0J, Kanal\u00a0E, Heuer\u00a0H, Sommer\u00a0T et\u00a0al (2011) Magnetic resonance imaging in patients with a\u00a0pacemaker system designed for the magnetic resonance environment. Heart Rhythm 8(1):65\u201373. https:\/\/doi.org\/10.1016\/j.hrthm.2010.10.002","journal-title":"Heart Rhythm"},{"issue":"26","key":"1601_CR26","doi-asserted-by":"publisher","first-page":"2555","DOI":"10.1056\/NEJMoa1604267","volume":"377","author":"S Nazarian","year":"2017","unstructured":"Nazarian\u00a0S, Hansford\u00a0R, Rahsepar\u00a0AA, Weltin\u00a0V, McVeigh\u00a0D, Ipek\u00a0EG, Halperin\u00a0HR et\u00a0al (2017) Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices. New England Journal of Medicine 377(26):2555\u20132564. https:\/\/doi.org\/10.1056\/NEJMoa1604267","journal-title":"New England Journal of Medicine"},{"issue":"21","key":"1601_CR27","doi-asserted-by":"publisher","first-page":"R99","DOI":"10.1088\/0031-9155\/54\/21\/R01","volume":"54","author":"PM Glover","year":"2009","unstructured":"Glover\u00a0PM (2009) Interaction of MRI field gradients with the human body. Physics in Medicine and Biology 54(21):R99\u2013R115. https:\/\/doi.org\/10.1088\/0031-9155\/54\/21\/R01","journal-title":"Physics in Medicine and Biology"},{"issue":"1","key":"1601_CR28","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1148\/radiol.2531091030","volume":"253","author":"FG Shellock","year":"2009","unstructured":"Shellock\u00a0FG, Woods\u00a0TO, Crues\u00a0JV (2009) MR Labeling Information for Implants and Devices: Explanation of Terminology. Radiology 253(1):26\u201330. https:\/\/doi.org\/10.1148\/radiol.2531091030","journal-title":"Radiology"},{"key":"1601_CR29","volume-title":"Medizinische elektrische Ger\u00e4te - Teil 2-33: Besondere Festlegungen f\u00fcr die Sicherheit von Magnetresonanzger\u00e4ten f\u00fcr die medizinische Diagnostik (IEC 60601-2-33:2022 + ISH1:2023); Deutsche Fassung EN IEC 60601-2-33:2024","author":"DIN EN IEC 60601-2-33:2025-07","year":"2025","unstructured":"DIN EN IEC 60601-2-33:2025-07 (2025) Medizinische elektrische Ger\u00e4te - Teil 2\u201133: Besondere Festlegungen f\u00fcr die Sicherheit von Magnetresonanzger\u00e4ten f\u00fcr die medizinische Diagnostik (IEC 60601-2-33:2022 + ISH1:2023); Deutsche Fassung EN IEC 60601-2-33:2024"},{"key":"1601_CR30","unstructured":"IEC 62570:2025 Standard practice for marking medical devices and other items for safety in the magnetic resonance environment. (2025, September\u00a018)."},{"key":"1601_CR31","unstructured":"ASTM F2503-20 Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment. (2023, May 25)."},{"key":"1601_CR32","unstructured":"(2022) Verordnung zum Schutz der Besch\u00e4ftigten vor Gef\u00e4hrdungen durch elektromagnetische Felder (Arbeitsschutzverordnung zu elektromagnetischen Feldern - EMFV)."},{"key":"1601_CR33","unstructured":"(2023) Technische Regeln zur Arbeitsschutz-verordnung zu elektro-magnetischen Feldern (TREMF)."},{"key":"1601_CR34","doi-asserted-by":"publisher","DOI":"10.31030\/3000219","volume-title":"DIN 6876:2019-05 Betrieb von medizinischen Magnetresonanzsystemen","author":"DIN 6876:2019-05 Betrieb von medizinischen Magnetresonanzsystemen","year":"2019","unstructured":"DIN 6876:2019-05 Betrieb von medizinischen Magnetresonanzsystemen (2019) DIN 6876:2019-05 Betrieb von medizinischen Magnetresonanzsystemen https:\/\/doi.org\/10.31030\/3000219"},{"issue":"6","key":"1601_CR35","doi-asserted-by":"publisher","first-page":"1478","DOI":"10.1002\/jmri.24993","volume":"42","author":"S Sammet","year":"2015","unstructured":"Sammet\u00a0S, Sammet\u00a0CL (2015) Implementation of a\u00a0comprehensive MR safety course for medical students. Journal of Magnetic Resonance Imaging 42(6):1478\u20131486. https:\/\/doi.org\/10.1002\/jmri.24993","journal-title":"Journal of Magnetic Resonance Imaging"},{"key":"1601_CR36","unstructured":"American College of Radiology (2024) ACR Manual on MR Safety 2024."},{"key":"1601_CR37","doi-asserted-by":"publisher","unstructured":"Trattnig S, Herold C. (2019) Magnetresonanztomographische Sicherheit von (elektronischen) Implantaten und Devices. Radiologe 59(10):859.  https:\/\/doi.org\/10.1007\/s00117-019-00596-y","DOI":"10.1007\/s00117-019-00596-y"},{"key":"1601_CR38","unstructured":"(2023) Testing and Labeling Medical Devices for Safety in the Magnetic Resonance (MR) Environment."},{"key":"1601_CR39","volume-title":"MRI Bioeffects, Safety, and Patient Management","year":"2022","unstructured":"Shellock\u00a0F, Crues\u00a0J III, Karacozoff\u00a0A (eds) (2022) MRI Bioeffects, Safety, and Patient Management, 2\u00a0edn. Biomedical Research Publishing Group, Los Angeles","edition":"2"},{"issue":"3","key":"1601_CR40","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1148\/radiol.2323030830","volume":"232","author":"FG Shellock","year":"2004","unstructured":"Shellock\u00a0FG, Crues\u00a0JV (2004) MR Procedures: Biologic Effects, Safety, and Patient Care. Radiology 232(3):635\u2013652. https:\/\/doi.org\/10.1148\/radiol.2323030830","journal-title":"Radiology"},{"issue":"5","key":"1601_CR41","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1002\/jmri.10196","volume":"16","author":"FG Shellock","year":"2002","unstructured":"Shellock\u00a0FG (2002) Magnetic resonance safety update 2002: Implants and devices. Journal of Magnetic Resonance Imaging 16(5):485\u2013496. https:\/\/doi.org\/10.1002\/jmri.10196","journal-title":"Journal of Magnetic Resonance Imaging"},{"issue":"6","key":"1601_CR42","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.3390\/ijerph6061778","volume":"6","author":"V Hartwig","year":"2009","unstructured":"Hartwig\u00a0V, Giovannetti\u00a0G, Vanello\u00a0N, Lombardi\u00a0M, Landini\u00a0L, Simi\u00a0S (2009) Biological Effects and Safety in Magnetic Resonance Imaging: A Review. International Journal of Environmental Research and Public Health 6(6):1778\u20131798. https:\/\/doi.org\/10.3390\/ijerph6061778","journal-title":"International Journal of Environmental Research and Public Health"},{"issue":"3","key":"1601_CR43","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1007\/s12181-021-00474-9","volume":"15","author":"F von Knobelsdorff","year":"2021","unstructured":"von Knobelsdorff\u00a0F, Bauer\u00a0WR, Busch\u00a0S, Eitel\u00a0I, Jensen\u00a0C, Marx\u00a0N, Rolf\u00a0A et\u00a0al (2021) Sicherheit von nicht-aktiven kardiovaskul\u00e4ren Implantaten bei MRT-Untersuchungen \u2013 Update 2021. Der Kardiologe 15(3):262\u2013271. https:\/\/doi.org\/10.1007\/s12181-021-00474-9","journal-title":"Der Kardiologe"},{"issue":"1","key":"1601_CR44","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1097\/MAO.0000000000003339","volume":"43","author":"DE Bestourous","year":"2022","unstructured":"Bestourous\u00a0DE, Davidson\u00a0L, Reilly\u00a0BK (2022) A Review of Reported Adverse Events in MRI-Safe and MRI-Conditional Cochlear Implants. Otology & Neurotology: Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology 43(1):42\u201347. https:\/\/doi.org\/10.1097\/MAO.0000000000003339","journal-title":"Otology & Neurotology: Official Publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology"},{"issue":"12","key":"1601_CR45","doi-asserted-by":"publisher","first-page":"972.e9","DOI":"10.1016\/j.crad.2019.06.011","volume":"74","author":"R Srinivasan","year":"2019","unstructured":"Srinivasan\u00a0R, So\u00a0CW, Amin\u00a0N, Jaikaransingh\u00a0D, D\u2019Arco\u00a0F, Nash\u00a0R (2019) A\u00a0review of the safety of MRI in cochlear implant patients with retained magnets. Clinical Radiology 74(12):972.e9\u2013972.e16. https:\/\/doi.org\/10.1016\/j.crad.2019.06.011","journal-title":"Clinical Radiology"},{"key":"1601_CR46","volume-title":"Reference Manual for Magnetic Resonance Safety, Implants, and Devices","author":"F Shellock","year":"2010","unstructured":"Shellock\u00a0F (2010) Reference Manual for Magnetic Resonance Safety, Implants, and Devices. Biomedical Research Publishing Group, Los Angeles"},{"issue":"3","key":"1601_CR47","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1002\/jmri.10069","volume":"15","author":"AR Rezai","year":"2002","unstructured":"Rezai\u00a0AR, Finelli\u00a0D, Nyenhuis\u00a0JA, Hrdlicka\u00a0G, Tkach\u00a0J, Sharan\u00a0A, Shellock\u00a0FG (2002) Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging\u2013related heating at 1.5 tesla. Journal of Magnetic Resonance Imaging 15(3):241\u2013250. https:\/\/doi.org\/10.1002\/jmri.10069","journal-title":"Journal of Magnetic Resonance Imaging"},{"issue":"5","key":"1601_CR48","doi-asserted-by":"publisher","first-page":"4133","DOI":"10.1109\/20.800779","volume":"35","author":"JA Nyenhuis","year":"1999","unstructured":"Nyenhuis\u00a0JA, Kildishev\u00a0AV, Bourland\u00a0JD, Foster\u00a0KS, Graber\u00a0G, Athey\u00a0TW (1999) Heating near implanted medical devices by the MRI RF-magnetic field. IEEE Transactions on Magnetics 35(5):4133\u20134135. https:\/\/doi.org\/10.1109\/20.800779","journal-title":"IEEE Transactions on Magnetics"},{"key":"1601_CR49","unstructured":"Nyenhuis, J. A., & Kildishev, A. V. (n.\u202fd.). Health effects of induced electrical currents: implications for implants. In Magnetic Resonance Procedures: Health Effects and Safety. Boca Raton: CRC Press."},{"issue":"9","key":"1601_CR50","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1001\/jama.2016.12126","volume":"316","author":"JG Ray","year":"2016","unstructured":"Ray\u00a0JG, Vermeulen\u00a0MJ, Bharatha\u00a0A, Montanera\u00a0WJ, Park\u00a0AL (2016) Association Between MRI Exposure During Pregnancy and Fetal and Childhood Outcomes. JAMA 316(9):952\u2013961. https:\/\/doi.org\/10.1001\/jama.2016.12126","journal-title":"JAMA"},{"issue":"4","key":"1601_CR51","doi-asserted-by":"publisher","first-page":"1785","DOI":"10.1007\/s00330-024-11055-1","volume":"35","author":"F Santini","year":"2025","unstructured":"Santini\u00a0F, Pansini\u00a0M, Deligianni\u00a0X, Caligiuri\u00a0ME, Oei\u00a0EHG (2025) ESR Essentials: advanced MR safety in vulnerable patients\u2014practice recommendations by the European Society for Magnetic Resonance in Medicine and Biology. European Radiology 35(4):1785\u20131793. https:\/\/doi.org\/10.1007\/s00330-024-11055-1","journal-title":"European Radiology"},{"key":"1601_CR52","doi-asserted-by":"publisher","DOI":"10.12659\/AJCR.943411","volume":"25","author":"KK Alsing","year":"2024","unstructured":"Alsing\u00a0KK, Johannesen\u00a0HH, M\u00e5rtensson\u00a0NL, Kempen\u00a0PJ, Hong Lin\u00a0MKT, Qvortrup\u00a0K, Hansen\u00a0RH (2024) Unveiling the Temporal Aspect of MRI Tattoo Reactions: A Prospective Evaluation of a Newly-Acquired Tattoo with Multiple MRI Scans. The American Journal of Case Reports 25:e943411. https:\/\/doi.org\/10.12659\/AJCR.943411","journal-title":"The American Journal of Case Reports"},{"key":"1601_CR53","unstructured":"R\u00f6ntgen, CT und MRT in Berlin und Nauen | Ihre-Radiologen.de (n. d.) R\u00f6ntgen, CT und MRT in Berlin und Nauen | Ihre-Radiologen.de. https:\/\/www.ihre-radiologen.de\/. Accessed 3.2.2026"},{"key":"1601_CR54","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/978-3-642-59581-3_13","volume-title":"Open Field Magnetic Resonance Imaging: Equipment, Diagnosis and Interventional Procedures","author":"FG Shellock","year":"2000","unstructured":"Shellock\u00a0FG (2000) Magnetic Resonance: Safety, Bioeffects, and Patient Monitoring. In: Gr\u00f6nemeyer\u00a0DHW, Lufkin\u00a0RB (eds) Open Field Magnetic Resonance Imaging: Equipment, Diagnosis and Interventional Procedures. Springer, Berlin, Heidelberg, pp\u00a0127\u2013145 https:\/\/doi.org\/10.1007\/978-3-642-59581-3_13"},{"issue":"3","key":"1601_CR55","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1148\/radiology.176.3.2202008","volume":"176","author":"E Kanal","year":"1990","unstructured":"Kanal\u00a0E, Shellock\u00a0FG, Talagala\u00a0L (1990) Safety considerations in MR imaging. Radiology 176(3):593\u2013606. https:\/\/doi.org\/10.1148\/radiology.176.3.2202008","journal-title":"Radiology"},{"key":"1601_CR56","doi-asserted-by":"crossref","unstructured":"Schenck, J. F. (2000). Safety of Strong, Static Magnetic Fields. Journal of Magnetic Resonance Imaging, 12(1), 2\u201319. https:\/\/doi.org\/10.1002\/1522-2586(200007)12:1\u30082::AID-JMRI2\u30093.0.CO;2\u2011V","DOI":"10.1002\/1522-2586(200007)12:1<2::AID-JMRI2>3.0.CO;2-V"},{"key":"1601_CR57","unstructured":"Safety Topic\/Article: (n.\u202fd.). Retrieved February\u00a03, 2026, from https:\/\/www.mrisafety.com\/SafetyInformation_view.php?editid1=166"},{"issue":"9","key":"1601_CR58","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1007\/s001170050421","volume":"38","author":"MV Knopp","year":"1998","unstructured":"Knopp\u00a0MV, Metzner\u00a0R, Brix\u00a0G, van Kaick\u00a0G (1998) Sicherheitsaspekte zur Vermeidung strominduzierter Hautverbrennungen in der MRT. Der Radiologe 38(9):759\u2013763. https:\/\/doi.org\/10.1007\/s001170050421","journal-title":"Der Radiologe"},{"issue":"5","key":"1601_CR59","doi-asserted-by":"publisher","first-page":"348","DOI":"10.3949\/ccjm.84a.15164","volume":"84","author":"NS Mandel","year":"2017","unstructured":"Mandel\u00a0NS, Ramdial\u00a0JL, Marcus\u00a0EN (2017) A\u00a0second-degree burn after MRI. Cleveland Clinic Journal of Medicine 84(5):348\u2013349. https:\/\/doi.org\/10.3949\/ccjm.84a.15164","journal-title":"Cleveland Clinic Journal of Medicine"},{"issue":"4","key":"1601_CR60","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1097\/RMR.0000000000000246","volume":"29","author":"CL Brunnquell","year":"2020","unstructured":"Brunnquell\u00a0CL, Hoff\u00a0MN, Balu\u00a0N, Nguyen\u00a0XV, Oztek\u00a0MA, Haynor\u00a0DR (2020) Making Magnets More Attractive: Physics and Engineering Contributions to Patient Comfort in MRI. Topics in Magnetic Resonance Imaging 29(4):167. https:\/\/doi.org\/10.1097\/RMR.0000000000000246","journal-title":"Topics in Magnetic Resonance Imaging"},{"key":"1601_CR61","doi-asserted-by":"publisher","unstructured":"Alibek S, Vogel M, Sun W, Winkler D, Baker CA, Burke M. (2014) Acoustic noise reduction in MRI using Silent Scan: an initial experience. Diagn Interv Radiol 20(4):360-363. https:\/\/doi.org\/10.5152\/dir.2014.13458","DOI":"10.5152\/dir.2014.13458"}],"container-title":["Die Radiologie"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00117-026-01601-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00117-026-01601-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00117-026-01601-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T15:31:49Z","timestamp":1776699109000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00117-026-01601-x"}},"subtitle":["Grundlagen, Risiken und Schutzma\u00dfnahmen","Principles, risks and protective measures"],"short-title":[],"issued":{"date-parts":[[2026,4,7]]},"references-count":62,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["1601"],"URL":"https:\/\/doi.org\/10.1007\/s00117-026-01601-x","relation":{},"ISSN":["2731-7048","2731-7056"],"issn-type":[{"value":"2731-7048","type":"print"},{"value":"2731-7056","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,7]]},"assertion":[{"value":"18 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}},{"value":"Gem\u00e4\u00df den Richtlinien des Springer Medizin Verlags werden Autoren und Wissenschaftliche Leitung im Rahmen der Manuskripterstellung und Manuskriptfreigabe aufgefordert, eine vollst\u00e4ndige Erkl\u00e4rung zu ihren finanziellen und nichtfinanziellen Interessen abzugeben.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}},{"value":"M.\u00a0Bock\n                      : A. Finanzielle Interessen: Institutionelle Forschungskooperation mit der Fa. Siemens Healthineers. \u2013 B. Nichtfinanzielle Interessen: Forschungsprofessor im Bereich der Medizinischen Physik | Mitgliedschaften: DGMP, DGP, ISMRM.\n                      U.\u00a0Ludwig\n                      : A. Finanzielle Interessen: Universit\u00e4tsklinikum Freiburg, Akademie f\u00fcr medizinische Berufe, Schule f\u00fcr Medizinisch-technische Radiologieassistenz, Referentin. \u2013 B. Nichtfinanzielle Interessen: Wissenschaftliche Angestellte, Universit\u00e4tsklinikum Freiburg, Klinik f\u00fcr Diagnostische und Interventionelle Radiologie, Abt. Medizinphysik, Freiburg.\n                      J.\u00a0Fischer\n                      : A. Finanzielle Interessen: Sachbeihilfe der DFG. \u2013 B. Nichtfinanzielle Interessen: Wissenschaftlicher Mitarbeiter, Universit\u00e4tsklinikum Freiburg.\n                      W.\u00a0Reichardt\n                      : A. Finanzielle Interessen: 2021-01-01 to present | Grant German Research Foundation (Bonn, DE), Homepage-URL:\n                      \n                      GRANT_NUMBER: 464645306. \u2013 B. Nichtfinanzielle Interessen: Angestellter stellvertretender Gruppenleiter Radiologische Klinik, Abt. Medizinphysik, Universit\u00e4tsklinik Freiburg im Breisgau | Mitglied: European Society of Molecular Imaging (ESMI).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Autorinnen und Autoren"}},{"value":"Die vollst\u00e4ndige Erkl\u00e4rung zum Interessenkonflikt der Wissenschaftlichen Leitung finden Sie am Kurs der zertifizierten Fortbildung auf\n                      \n                      .","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Wissenschaftliche Leitung"}},{"value":"erkl\u00e4rt, dass f\u00fcr die Publikation dieser CME-Fortbildung keine Sponsorengelder an den Verlag flie\u00dfen.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Der Verlag"}},{"value":"F\u00fcr diesen Beitrag wurden von den Autor\/-innen keine Studien an Menschen oder Tieren durchgef\u00fchrt. F\u00fcr die aufgef\u00fchrten Studien gelten die jeweils dort angegebenen ethischen Richtlinien.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Der Verlag"}}]}}