{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:14:16Z","timestamp":1786979656293,"version":"build-2736575974"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2017,3,31]],"date-time":"2017-03-31T00:00:00Z","timestamp":1490918400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Orthop\u00e4de"],"published-print":{"date-parts":[[2017,7]]},"DOI":"10.1007\/s00132-017-3418-2","type":"journal-article","created":{"date-parts":[[2017,3,31]],"date-time":"2017-03-31T11:34:19Z","timestamp":1490960059000},"page":"610-616","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Verhinderung einer Fraktur der Gegenkortikalis bei aufklappender Osteotomie","Prevention of lateral cortex fractures in open wedge high tibial osteotomies"],"prefix":"10.1007","volume":"46","author":[{"given":"G.","family":"Reyle","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"O.","family":"Lorbach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Diffo Kaze","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Hoffmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Pape","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,3,31]]},"reference":[{"key":"3418_CR1","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.arthro.2011.06.034","volume":"28","author":"R Takeuchi","year":"2012","unstructured":"Takeuchi R, Ishikawa H, Kumagai K, Yamaguchi Y, Chiba N, Akamatsu Y, Saito T (2012) Fractures around the lateral cortical hinge after a\u00a0medial opening-wedge high tibial osteotomy: a\u00a0new classification of lateral hinge fracture. Arthroscopy 28:85\u201394","journal-title":"Arthroscopy"},{"key":"3418_CR2","doi-asserted-by":"crossref","first-page":"389","DOI":"10.5435\/00124635-199911000-00005","volume":"7","author":"BJ Cole","year":"1999","unstructured":"Cole BJ, Harner CD (1999) Degenerative arthritis of the knee in active patients: evaluation and management. J\u00a0Am Acad Orthop Surg 7:389\u2013402","journal-title":"J Am Acad Orthop Surg"},{"key":"3418_CR3","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1007\/s00167-002-0334-7","volume":"11","author":"P Lobenhoffer","year":"2003","unstructured":"Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11:132\u2013138","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3418_CR4","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1007\/s00132-003-0593-0","volume":"33","author":"P Lobenhoffer","year":"2004","unstructured":"Lobenhoffer P, Agneskirchner J, Zoch W (2004) Open valgus alignment osteotomy of the proximal tibia with fixation by medial plate fixator. Orthop\u00e4de 33:153\u2013160","journal-title":"Orthop\u00e4de"},{"issue":"Suppl 2","key":"3418_CR5","doi-asserted-by":"crossref","first-page":"B55","DOI":"10.1016\/j.injury.2003.09.025","volume":"34","author":"AE Staubli","year":"2003","unstructured":"Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a\u00a0new LCP-concept for open wedge osteotomy of the medial proximal tibia \u2013 early results in 92 cases. Injury 34(Suppl 2):B55\u2013B62","journal-title":"Injury"},{"key":"3418_CR6","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.knee.2015.12.008","volume":"23","author":"DK Bae","year":"2016","unstructured":"Bae DK, Park CH, Kim EJ, Song SJ (2016) Medial cortical fractures in computer-assisted closing-wedge high tibial osteotomy. Knee 23:295\u2013299","journal-title":"Knee"},{"key":"3418_CR7","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1097\/00003086-200202000-00020","volume":"395","author":"OC Kessler","year":"2002","unstructured":"Kessler OC, Jacob HA, Romero J (2002) Avoidance of medial cortical fracture in high tibial osteotomy: improved technique. Clin Orthop Relat Res 395:180\u2013185","journal-title":"Clin Orthop Relat Res"},{"key":"3418_CR8","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1007\/s00132-003-0591-2","volume":"33","author":"D Pape","year":"2004","unstructured":"Pape D, Adam F, Rupp S, Seil R, Kohn D (2004) Stability, bone healing and loss of correction after valgus realignment of the tibial head. A roentgen stereometry analysis. Orthop\u00e4de 33:208\u2013217","journal-title":"Orthop\u00e4de"},{"key":"3418_CR9","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1007\/s00132-014-3026-3","volume":"43","author":"S Schroter","year":"2014","unstructured":"Schroter S, Ateschrang A, Ihle C, Stockle U, Konstantinidis L, Dobele S (2014) Lateral hinge fractures in open wedge high tibial osteotomy. Orthop\u00e4de 43:1000\u20131007","journal-title":"Orthop\u00e4de"},{"key":"3418_CR10","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1007\/s11999-013-3383-y","volume":"472","author":"AH Houten van","year":"2014","unstructured":"van Houten AH, Heesterbeek PJ, van Heerwaarden RJ, van Tienen TG, Wymenga AB (2014) Medial open wedge high tibial osteotomy: can delayed or nonunion be predicted? Clin Orthop Relat Res 472:1217\u20131223","journal-title":"Clin Orthop Relat Res"},{"key":"3418_CR11","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1080\/17453670710015508","volume":"79","author":"TM Raaij van","year":"2008","unstructured":"van Raaij TM, Brouwer RW, de Vlieger R, Reijman M, Verhaar JA (2008) Opposite cortical fracture in high tibial osteotomy: lateral closing compared to the medial opening-wedge technique. Acta Orthop 79:508\u2013514","journal-title":"Acta Orthop"},{"key":"3418_CR12","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1007\/s00167-011-1706-7","volume":"21","author":"SB Han","year":"2013","unstructured":"Han SB, Lee DH, Shetty GM, Chae DJ, Song JG, Nha KW (2013) A \u201csafe zone\u201d in medial open-wedge high tibia osteotomy to prevent lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 21:90\u201395","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3418_CR13","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.knee.2015.09.018","volume":"23","author":"T Woodacre","year":"2016","unstructured":"Woodacre T, Ricketts M, Evans JT, Pavlou G, Schranz P, Hockings M (2016) Complications associated with opening wedge high tibial osteotomy \u2013 a review of the literature and of 15 years of experience. Knee 23:282","journal-title":"Knee"},{"key":"3418_CR14","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1186\/s40634-015-0030-4","volume":"2","author":"KA Diffo","year":"2015","unstructured":"Diffo KA, Maas S, Waldmann D, Zilian A, Dueck K, Pape D (2015) Biomechanical properties of five different currently used implants for open-wedge high tibial osteotomy. J\u00a0Exp Orthop 2:14","journal-title":"J Exp Orthop"},{"key":"3418_CR15","doi-asserted-by":"publisher","first-page":"387620","DOI":"10.1155\/2013\/387620.","volume":"2013","author":"S Maas","year":"2013","unstructured":"Maas S, Diffo KA, Dueck K, Pape D (2013) Static and dynamic differences in fixation stability between a\u00a0spacer plate and a\u00a0small stature plate fixator used for high tibial osteotomies: a biomechanical bone composite study. ISRN Orthop 2013:387620. doi:\n                        10.1155\/2013\/387620","journal-title":"ISRN Orthop"},{"key":"3418_CR16","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1007\/s00167-011-1693-8","volume":"21","author":"D Pape","year":"2013","unstructured":"Pape D, Kohn D, van Giffen N, Hoffmann A, Seil R, Lorbach O (2013) Differences in fixation stability between spacer plate and plate fixator following high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 21:82\u201389","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3418_CR17","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1115\/1.2746369","volume":"129","author":"AC Chong","year":"2007","unstructured":"Chong AC, Miller F, Buxton M, Friis E (2007) Fracture toughness and fatigue crack propagation rate of short fiber reinforced epoxy composites for analogue cortical bone. J\u00a0Biomech Eng 129:487\u2013493","journal-title":"J Biomech Eng"},{"key":"3418_CR18","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1007\/s10439-009-9887-7","volume":"38","author":"MP Gardner","year":"2010","unstructured":"Gardner MP, Chong ACM, Pollock AG, Wooley PH (2010) Mechanical evaluation of large-size fourth-generation composite femur and tibia models. Ann Biomed Eng 38:613\u2013620","journal-title":"Ann Biomed Eng"},{"key":"3418_CR19","doi-asserted-by":"crossref","first-page":"3282","DOI":"10.1016\/j.jbiomech.2008.08.013","volume":"41","author":"A Heiner","year":"2008","unstructured":"Heiner A (2008) Structural properties of fourth-generation composite femurs and tibias. J\u00a0Biomech 41:3282\u20133284","journal-title":"J Biomech"},{"key":"3418_CR20","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1007\/s00264-009-0902-2","volume":"34","author":"AE Staubli","year":"2010","unstructured":"Staubli AE, Jacob HA (2010) Evolution of open-wedge high-tibial osteotomy: experience with a\u00a0special angular stable device for internal fixation without interposition material. Int Orthop 34:167\u2013172","journal-title":"Int Orthop"},{"key":"3418_CR21","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/S1060-1872(00)80022-2","volume":"8","author":"P Fowler","year":"2000","unstructured":"Fowler P, Tan L, Brown G (2000) Medial opening wedge high tibial osteotomy: How I do it. Oper Tech Sports Med 8:32\u201338","journal-title":"Oper Tech Sports Med"},{"key":"3418_CR22","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1007\/s00132-003-0585-0","volume":"33","author":"D Pape","year":"2004","unstructured":"Pape D, Seil R, Adam F, Rupp S, Kohn D, Lobenhoffer P (2004) Imaging and preoperative planning of osteotomy of tibial head osteotomy. Orthop\u00e4de 33:122\u2013134","journal-title":"Orthop\u00e4de"}],"container-title":["Der Orthop\u00e4de"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00132-017-3418-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00132-017-3418-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00132-017-3418-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,7,5]],"date-time":"2017-07-05T07:29:29Z","timestamp":1499239769000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00132-017-3418-2"}},"subtitle":["Anteroposteriore Bohrung als L\u00f6sungsansatz","The anteroposterior drill hole approach"],"short-title":[],"issued":{"date-parts":[[2017,3,31]]},"references-count":22,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2017,7]]}},"alternative-id":["3418"],"URL":"https:\/\/doi.org\/10.1007\/s00132-017-3418-2","relation":{},"ISSN":["0085-4530","1433-0431"],"issn-type":[{"value":"0085-4530","type":"print"},{"value":"1433-0431","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,31]]}}}