{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T18:18:56Z","timestamp":1781893136790,"version":"3.54.5"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2021,10,25]],"date-time":"2021-10-25T00:00:00Z","timestamp":1635120000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,10,25]],"date-time":"2021-10-25T00:00:00Z","timestamp":1635120000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Orthop\u00e4de"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s00132-021-04180-y","type":"journal-article","created":{"date-parts":[[2021,10,25]],"date-time":"2021-10-25T11:12:00Z","timestamp":1635160320000},"page":"972-978","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Lockerungsdiagnostik in der Knieendoprothetik","Diagnosis of loosening after knee arthroplasty"],"prefix":"10.1007","volume":"50","author":[{"given":"Christoph","family":"Stotter","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"von Roth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,10,25]]},"reference":[{"issue":"9","key":"4180_CR1","doi-asserted-by":"publisher","first-page":"715","DOI":"10.2106\/JBJS.M.01534","volume":"97","author":"K Thiele","year":"2015","unstructured":"Thiele\u00a0K et\u00a0al (2015) Current failure mechanisms after knee arthroplasty have changed: polyethylene wear is less common in revision surgery. J\u00a0Bone Joint Surg Am 97(9):715\u2013720","journal-title":"J Bone Joint Surg Am"},{"issue":"Suppl 1","key":"4180_CR2","doi-asserted-by":"publisher","first-page":"S6","DOI":"10.1186\/ar2170","volume":"9","author":"Y Abu-Amer","year":"2007","unstructured":"Abu-Amer\u00a0Y, Darwech\u00a0I, Clohisy\u00a0JC (2007) Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies. Arthritis Res Ther 9(Suppl 1):S6","journal-title":"Arthritis Res Ther"},{"issue":"1","key":"4180_CR3","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1007\/s11999-012-2467-4","volume":"471","author":"D Arsoy","year":"2013","unstructured":"Arsoy\u00a0D et\u00a0al (2013) Aseptic tibial debonding as a\u00a0cause of early failure in a\u00a0modern total knee arthroplasty design. Clin Orthop Relat Res 471(1):94\u2013101","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"4180_CR4","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1055\/s-0037-1603756","volume":"30","author":"PM Bonutti","year":"2017","unstructured":"Bonutti\u00a0PM et al (2017) Unusually high rate of early failure of tibial component in ATTUNE total knee arthroplasty system at implant-cement interface. J\u00a0Knee Surg 30(5):435\u2013439","journal-title":"J Knee Surg"},{"key":"4180_CR5","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1097\/00003086-198911000-00003","volume":"248","author":"FC Ewald","year":"1989","unstructured":"Ewald\u00a0FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9\u201312","journal-title":"Clin Orthop Relat Res"},{"key":"4180_CR6","volume-title":"Revision total knee arthroplasty","author":"H Levine","year":"2018","unstructured":"Levine\u00a0H, Madoff\u00a0S, Newman\u00a0JS (2018) Imaging of total knee arthroplasty. In: Scott\u00a0RD, Bono\u00a0JV (Hrsg) Revision total knee arthroplasty. Springer Nature, Cham"},{"issue":"11S","key":"4180_CR7","first-page":"S421","volume":"14","author":"Expert Panel on Musculoskeletal\u00a0Imaging","year":"2017","unstructured":"Expert Panel on Musculoskeletal\u00a0Imaging (2017) ACR appropriateness criteria((R)) imaging after total knee arthroplasty. J\u00a0Am Coll Radiol 14(11S):S421\u2013S448","journal-title":"J Am Coll Radiol"},{"issue":"1","key":"4180_CR8","doi-asserted-by":"publisher","first-page":"W76","DOI":"10.2214\/AJR.13.11308","volume":"202","author":"H Mulcahy","year":"2014","unstructured":"Mulcahy\u00a0H, Chew\u00a0FS (2014) Current concepts in knee replacement: complications. AJR Am J Roentgenol 202(1):W76\u201386","journal-title":"AJR Am J Roentgenol"},{"key":"4180_CR9","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1097\/00003086-199610000-00032","volume":"331","author":"TK Fehring","year":"1996","unstructured":"Fehring\u00a0TK, McAvoy\u00a0G (1996) Fluoroscopic evaluation of the painful total knee arthroplasty. Clin Orthop Relat Res 331:226\u2013233","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"4180_CR10","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/S0009-9260(05)81699-X","volume":"41","author":"BR Duus","year":"1990","unstructured":"Duus\u00a0BR, Boeckstyns\u00a0M, Stadeager\u00a0C (1990) The natural course of radionuclide bone scanning in the evaluation of total knee replacement\u2014a 2 year prospective study. Clin Radiol 41(5):341\u2013343","journal-title":"Clin Radiol"},{"issue":"2","key":"4180_CR11","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1016\/S0033-8389(22)00420-1","volume":"33","author":"AM Allen","year":"1995","unstructured":"Allen\u00a0AM, Ward\u00a0WG, Pope\u00a0TL Jr. (1995) Imaging of the total knee arthroplasty. Radiol Clin North Am 33(2):289\u2013303","journal-title":"Radiol Clin North Am"},{"issue":"3","key":"4180_CR12","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1053\/crad.2000.0620","volume":"56","author":"SL Smith","year":"2001","unstructured":"Smith\u00a0SL, Wastie\u00a0ML, Forster\u00a0I (2001) Radionuclide bone scintigraphy in the detection of significant complications after total knee joint replacement. Clin Radiol 56(3):221\u2013224","journal-title":"Clin Radiol"},{"key":"4180_CR13","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1097\/00003086-199002000-00031","volume":"251","author":"AA Hofmann","year":"1990","unstructured":"Hofmann\u00a0AA et\u00a0al (1990) Bone scans after total knee arthroplasty in asymptomatic patients. Cemented versus cementless. Clin Orthop Relat Res 251:183\u2013188","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"4180_CR14","doi-asserted-by":"publisher","first-page":"359","DOI":"10.2106\/JBJS.20.00301","volume":"17","author":"J Pinski","year":"2021","unstructured":"Pinski\u00a0J et\u00a0al (2021) Nuclear medicine scans in total joint replacement. J\u00a0Bone Joint Surg Am 17(4):359\u2013372","journal-title":"J Bone Joint Surg Am"},{"key":"4180_CR15","doi-asserted-by":"publisher","DOI":"10.1186\/s41824-021-00098-y","author":"B Bao","year":"2021","unstructured":"Bao\u00a0B et\u00a0al (2021) Diagnostic accuracy of SPECT\/CT arthrography in patients with suspected aseptic joint prostheses loosening. Eur J Hybrid Imaging. https:\/\/doi.org\/10.1186\/s41824-021-00098-y","journal-title":"Eur J Hybrid Imaging"},{"issue":"2","key":"4180_CR16","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.ijsu.2006.05.002","volume":"5","author":"T Sterner","year":"2007","unstructured":"Sterner\u00a0T et\u00a0al (2007) The role of [18F]fluoride positron emission tomography in the early detection of aseptic loosening of total knee arthroplasty. Int J Surg 5(2):99\u2013104","journal-title":"Int J Surg"},{"key":"4180_CR17","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/1471-2474-7-20","volume":"7","author":"KS Delank","year":"2006","unstructured":"Delank\u00a0KS et al (2006) The implications of 18F-FDG PET for the diagnosis of endoprosthetic loosening and infection in hip and knee arthroplasty: results from a\u00a0prospective, blinded study. BMC Musculoskelet Disord 7:20","journal-title":"BMC Musculoskelet Disord"},{"issue":"10","key":"4180_CR18","doi-asserted-by":"publisher","first-page":"1565","DOI":"10.1007\/s00256-019-03215-y","volume":"48","author":"L Barnsley","year":"2019","unstructured":"Barnsley\u00a0L, Barnsley\u00a0L (2019) Detection of aseptic loosening in total knee replacements: a\u00a0systematic review and meta-analysis. Skelet Radiol 48(10):1565\u20131572","journal-title":"Skelet Radiol"},{"key":"4180_CR19","unstructured":"von Roth P et al (2020) Handlungsempfehlung f\u00fcr die radiologische Verlaufskontrolle von prim\u00e4ren H\u00fcft- und Knieendoprothesen. https:\/\/www.ae-germany.com\/die-ae\/ae-publikationen\/ae-handlungsempfehlungen\/232-5-radiologische-verlaufskontrolle-von-primaeren-hueft-und-knieendoprothesen. Zugegriffen: 24. August 2021"},{"issue":"1","key":"4180_CR20","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1007\/s00132-015-3196-7","volume":"45","author":"K Thiele","year":"2016","unstructured":"Thiele\u00a0K et\u00a0al (2016) The Berlin diagnostic algorithm for painful knee TKA. Orthopade 45(1):38\u201346","journal-title":"Orthopade"},{"issue":"1","key":"4180_CR21","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1186\/s12891-020-03390-3","volume":"21","author":"H Verburg","year":"2020","unstructured":"Verburg\u00a0H et\u00a0al (2020) Reliability of two different measuring techniques with computer tomography for penetration and distribution of cement in the proximal tibia after total knee arthroplasty. BMC Musculoskelet Disord 21(1):374","journal-title":"BMC Musculoskelet Disord"}],"container-title":["Der Orthop\u00e4de"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00132-021-04180-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00132-021-04180-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00132-021-04180-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,13]],"date-time":"2023-01-13T17:18:54Z","timestamp":1673630334000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00132-021-04180-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,25]]},"references-count":21,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["4180"],"URL":"https:\/\/doi.org\/10.1007\/s00132-021-04180-y","relation":{},"ISSN":["0085-4530","1433-0431"],"issn-type":[{"value":"0085-4530","type":"print"},{"value":"1433-0431","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,25]]},"assertion":[{"value":"24 September 2021","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 October 2021","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}},{"value":"C.\u00a0Stotter und P.\u00a0von Roth geben an, dass kein Interessenkonflikt besteht.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}},{"value":"F\u00fcr diesen Beitrag wurden von den Autoren keine Studien an Menschen oder Tieren durchgef\u00fchrt. F\u00fcr die aufgef\u00fchrten Studien gelten die jeweils dort angegebenen ethischen Richtlinien.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}}]}}