{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T06:18:29Z","timestamp":1773901109246,"version":"3.50.1"},"reference-count":22,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2006,2,15]],"date-time":"2006-02-15T00:00:00Z","timestamp":1139961600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Knee surg. sports traumatol. arthrosc."],"published-print":{"date-parts":[[2006,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Poly\u2010<jats:sc>l<\/jats:sc>\u2010lactic acid biodegradable screws have been used effectively for graft fixation in anterior cruciate ligament (ACL) reconstruction. The overall complication rate associated with the use of this implant is low, although some authors reported complications, such as osteolysis and aseptic effusion of the knee joint. We report a case of a 29\u2010year\u2010old female patient with a failure of a biodegradable interference screw at 22\u00a0months after ACL reconstruction using bone\u2013patellar tendon\u2013bone graft. In this illustrated case, the screw broke and migrated into the knee joint. In addition, we performed a detailed review of the medical literature from 1990\u20132005 to identify possible causes of biodegradable screw failures. We identified six published cases of bioabsorbable interference screw failure with migration into the knee joint. Several authors have reported small diameter of the screw, poor bone quality, bone resorption, and screw divergence as potential causes for intraarticular migration of metallic interference screws. With regard to bioscrews, no specific risk factors for screw breakage and intraarticular migration have been reported. ACL reconstruction with the use of bioabsorbable interference screws for fixation is considered to be reliable. However, we need to be aware of potential problems associated with the use of this implant. Early recognition of bioscrew failure may prevent associated morbidities, such as subsequent cartilage damage.<\/jats:p>","DOI":"10.1007\/s00167-006-0049-2","type":"journal-article","created":{"date-parts":[[2006,2,14]],"date-time":"2006-02-14T13:25:57Z","timestamp":1139923557000},"page":"865-868","source":"Crossref","is-referenced-by-count":48,"title":["Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction"],"prefix":"10.1002","volume":"14","author":[{"given":"M. H.","family":"Baums","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery Georg\u2010August\u2010University of G\u00f6ttingen Robert\u2010Koch\u2010Strasse 40 37075 G\u00f6ttingen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B. A.","family":"Zelle","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Georg\u2010August\u2010University of G\u00f6ttingen Robert\u2010Koch\u2010Strasse 40 37075 G\u00f6ttingen Germany"},{"name":"Department of Orthopaedic Surgery University of Pittsburgh Medical Center Pittsburgh PA USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W.","family":"Schultz","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Georg\u2010August\u2010University of G\u00f6ttingen Robert\u2010Koch\u2010Strasse 40 37075 G\u00f6ttingen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Ernstberger","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Georg\u2010August\u2010University of G\u00f6ttingen Robert\u2010Koch\u2010Strasse 40 37075 G\u00f6ttingen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.\u2010M.","family":"Klinger","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Georg\u2010August\u2010University of G\u00f6ttingen Robert\u2010Koch\u2010Strasse 40 37075 G\u00f6ttingen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,2,15]]},"reference":[{"key":"e_1_2_4_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749\u20108063(99)70052\u20106"},{"key":"e_1_2_4_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142\u20109612(00)00130\u20107"},{"key":"e_1_2_4_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749\u20108063(95)90015\u20102"},{"key":"e_1_2_4_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749\u20108063(00)90126\u20109"},{"key":"e_1_2_4_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749\u20108063(00)90085\u20109"},{"key":"e_1_2_4_7_1","first-page":"32","article-title":"Migration of femoral interference screw after anterior cruciate ligament reconstruction","volume":"11","author":"Bush\u2010Joseph CA","year":"1998","journal-title":"Am J Knee Surg"},{"key":"e_1_2_4_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749\u20108063(05)80515\u20108"},{"key":"e_1_2_4_9_1","first-page":"997","article-title":"A complication of interference screw fixation in anterior cruciate ligament reconstruction","volume":"19","author":"Doerr AL","year":"1990","journal-title":"Orthop Rev"},{"key":"e_1_2_4_10_1","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2003.50070"},{"key":"e_1_2_4_11_1","doi-asserted-by":"publisher","DOI":"10.1177\/036354659402200307"},{"key":"e_1_2_4_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010004\u20100545\u20101"},{"key":"e_1_2_4_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.11.050"},{"key":"e_1_2_4_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749\u20108063(03)00382\u20107"},{"key":"e_1_2_4_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s001670050053"},{"key":"e_1_2_4_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749\u20108063(99)70042\u20103"},{"key":"e_1_2_4_17_1","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2002.36466"},{"key":"e_1_2_4_18_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199312000-00009"},{"key":"e_1_2_4_19_1","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2002.32197"},{"key":"e_1_2_4_20_1","doi-asserted-by":"publisher","DOI":"10.1177\/036354659702500223"},{"key":"e_1_2_4_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749\u20108063(97)90162\u20106"},{"key":"e_1_2_4_22_1","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2001.20661"},{"key":"e_1_2_4_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010001\u20100254\u2010y"}],"container-title":["Knee Surgery, Sports Traumatology, Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00167-006-0049-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00167-006-0049-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1007\/s00167-006-0049-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T12:29:17Z","timestamp":1760876957000},"score":1,"resource":{"primary":{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/10.1007\/s00167-006-0049-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,2,15]]},"references-count":22,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2006,9]]}},"alternative-id":["10.1007\/s00167-006-0049-2"],"URL":"https:\/\/doi.org\/10.1007\/s00167-006-0049-2","archive":["Portico"],"relation":{},"ISSN":["0942-2056","1433-7347"],"issn-type":[{"value":"0942-2056","type":"print"},{"value":"1433-7347","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,2,15]]}}}