{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T00:39:00Z","timestamp":1760920740214,"version":"build-2065373602"},"reference-count":25,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2013,7,10]],"date-time":"2013-07-10T00:00:00Z","timestamp":1373414400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Knee surg. sports traumatol. arthrosc."],"published-print":{"date-parts":[[2014,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>Previously, the clinical and radiological results of the self\u2010aligning cruciate retaining total knee prosthesis at 5\u2010years follow\u2010up were described. The 10\u2010year follow\u2010up is now reported to determine the clinical and radiological results and the survival of the prosthesis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A 10\u2010year follow\u2010up was performed in this prospectively followed cohort of 246 (232 patients) self\u2010aligning, cruciate retaining total knee arthroplasties performed between 1995 and 1998. Because patients had died and others suffered from comorbidities making them unable to attend a follow\u2010up consultation, data could be obtained for 105 prostheses. Clinical results were evaluated by the Knee Society Score, and radiological follow\u2010up was performed on standard AP and lateral X\u2010rays. All radiographs were evaluated for the presence of radiolucencies, osteolysis and wear.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>At the 10\u2010year follow\u2010up, there were no new cases of revision so that the cumulative survival rate at 10 years remains 95 %. The 10\u2010year follow\u2010up shows good clinical results with an average Knee Society Score of 154 (SD 35.7) and an average range of motion of 109\u00b0 (SD 13.7). After excluding 25 prostheses for comorbidities, the mean 10\u2010year KSS score increased from 154 to 163 (SD 26.2). On the other hand, for the ROM, the exclusion of the 25 prostheses had no influence on the mean ROM value of 109\u00b0. At the 10\u2010year follow\u2010up, none of the 100 available radiographs showed any radiolucencies &gt;2\u00a0mm on any component.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Long\u2010term follow\u2010up of the mobile bearing, cruciate retaining, SAL\u2010II total knee arthroplasty shows excellent clinical and radiological results without bearing dislocation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Level of evidence<\/jats:title><jats:p>Prospective cohort, Level IV.<\/jats:p><\/jats:sec>","DOI":"10.1007\/s00167-013-2601-1","type":"journal-article","created":{"date-parts":[[2013,7,9]],"date-time":"2013-07-09T01:05:14Z","timestamp":1373331914000},"page":"2728-2734","source":"Crossref","is-referenced-by-count":3,"title":["The self\u2010aligning knee prosthesis: clinical and radiological outcome and survival analysis of a cruciate retaining meniscal bearing knee at 10\u2010year follow\u2010up"],"prefix":"10.1002","volume":"22","author":[{"given":"R. A.","family":"van Stralen","sequence":"first","affiliation":[{"name":"Sint Maartenskliniek Postbus 9011, Hengstdal 3 6500 GM Nijmegen The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P. G.","family":"Anderson","sequence":"additional","affiliation":[{"name":"Sint Maartenskliniek Postbus 9011, Hengstdal 3 6500 GM Nijmegen The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. B.","family":"Wymenga","sequence":"additional","affiliation":[{"name":"Sint Maartenskliniek Postbus 9011, Hengstdal 3 6500 GM Nijmegen The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2013,7,10]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000063562.90853.6a"},{"key":"e_1_2_6_3_1","first-page":"247","article-title":"The role of rotating platform total knee replacements: design considerations, kinematics, and clinical results","volume":"15","author":"Bourne RB","year":"2002","journal-title":"J Knee Surg"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.I.01012"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010007\u20100434\u20105"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447\u201020121120\u201012"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198911000-00003"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010011\u20101758\u20108"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200102000-00010"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2006.07.002"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198911000-00004"},{"key":"e_1_2_6_12_1","first-page":"CD003130","article-title":"Mobile bearing vs fixed bearing prostheses for total knee arthroplasty for post\u2010operative functional status in patients with osteoarthritis and rheumatoid arthritis","volume":"2","author":"Jacobs W","year":"2004","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010011\u20101684\u20109"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086\u2010199910000\u201000025"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0883\u20105403(97)90179\u20100"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010004\u20100492\u2010x"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2010.09.031"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200403000-00010"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.02.015"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2011.02.013"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999\u2010010\u20101429\u2010y"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/1097\u20104636(2001)58:3<282::AID\u2010JBM1018>3.0.CO;2\u2010S"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2010.12.017"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010009\u20100909\u20107"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086\u2010200408000\u201000029"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010009\u20100973\u2010z"}],"container-title":["Knee Surgery, Sports Traumatology, Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00167-013-2601-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00167-013-2601-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1007\/s00167-013-2601-1","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T12:55:34Z","timestamp":1760878534000},"score":1,"resource":{"primary":{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/10.1007\/s00167-013-2601-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,10]]},"references-count":25,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2014,11]]}},"alternative-id":["10.1007\/s00167-013-2601-1"],"URL":"https:\/\/doi.org\/10.1007\/s00167-013-2601-1","archive":["Portico"],"relation":{},"ISSN":["0942-2056","1433-7347"],"issn-type":[{"type":"print","value":"0942-2056"},{"type":"electronic","value":"1433-7347"}],"subject":[],"published":{"date-parts":[[2013,7,10]]}}}