{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T09:49:54Z","timestamp":1779356994359,"version":"3.51.4"},"reference-count":16,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2014,5,2]],"date-time":"2014-05-02T00:00:00Z","timestamp":1398988800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2014,5,2]],"date-time":"2014-05-02T00:00:00Z","timestamp":1398988800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Knee surg. sports traumatol. arthrosc."],"published-print":{"date-parts":[[2014,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>(1) Do radiographic protocols for knee axial images vary across different clinic locations? (2) Does variability between radiographic positioning protocols (knee flexion angle, beam positioning) yield different radiographic measurements that could influence clinical assumptions?<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Radiographic positioning, including beam angle and knee flexion, was measured using a photograph taken of a phantom leg and (human) model set\u2010up. An axial radiograph of a phantom leg was taken at seven different outpatients musculoskeletal clinics to assess patella position (lateral tilt\/translation). The phantom leg patella was placed in an abnormal position for the radiographic image across all sites.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Knee flexion &lt;30\u00b0 was less accurate in obtaining requested knee flexion than higher knee flexion angles (phantom limb error averaged 6\u00b0, range 4\u00b0\u20137\u00b0 human model error averaged 15\u00b0, range 11\u00b0\u201325\u00b0). Of the five sites utilizing a \u2018Merchants\u2019 axial radiographs, the congruence angle varied from +12\u00b0 to +29\u00b0, being normal at one site (+12\u00b0) and abnormal (&gt;+16\u00b0) at three sites, and negative at one site (\u221215\u00b0).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Radiographic protocols for knee axial imaging are inconsistent in radiographic positioning and imaging. This variability can lead to disparity in radiographic image results used for clinical decision\u2010making. Standardization of radiographic positioning would yield more consistent imaging of patella position in early flexion, increasing clinical utility and accuracy.<\/jats:p><\/jats:sec>","DOI":"10.1007\/s00167-014-2982-9","type":"journal-article","created":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T11:39:11Z","timestamp":1398944351000},"page":"2401-2407","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Axial knee radiographs: consistency across clinic sites"],"prefix":"10.1002","volume":"22","author":[{"given":"Ashley","family":"Nord","sequence":"first","affiliation":[{"name":"Grand Rapids Medical Education Partners 49503 Grand Rapids MI USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julie","family":"Agel","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Minnesota 2450 Riverside Av., Ste. R200 55454 Minneapolis MN USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elizabeth A.","family":"Arendt","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Minnesota 2450 Riverside Av., Ste. R200 55454 Minneapolis MN USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2014,5,2]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0278\u20105919(02)00031\u20105"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199411000-00004"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.216.2.r00au07582"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/978\u20103\u2010642\u201005424\u20102_6"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546503260788"},{"key":"e_1_2_6_7_1","unstructured":"Computed radiography and digital radiography:A comparison of technology functionality patient dose and image quality(http:\/\/www.eradimaging.com\/site\/article.cfm?ID=535).ERADIMAGING.COM 2008. Accessed 17 Sept 2013"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197860010-00007"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.170.2.2911676"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197456070-00007"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.3109\/17453679708996254"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010012\u20102347\u20101"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01628492"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167\u2010003\u20100414\u20103"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2012.05.011"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00256\u2010010\u20100961\u2010x"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.3109\/17453678608994404"}],"container-title":["Knee Surgery, Sports Traumatology, Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00167-014-2982-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00167-014-2982-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1007\/s00167-014-2982-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T11:30:35Z","timestamp":1760873435000},"score":1,"resource":{"primary":{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/10.1007\/s00167-014-2982-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5,2]]},"references-count":16,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2014,10]]}},"alternative-id":["10.1007\/s00167-014-2982-9"],"URL":"https:\/\/doi.org\/10.1007\/s00167-014-2982-9","archive":["Portico"],"relation":{},"ISSN":["0942-2056","1433-7347"],"issn-type":[{"value":"0942-2056","type":"print"},{"value":"1433-7347","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5,2]]}}}