{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T16:01:15Z","timestamp":1776787275806,"version":"3.51.2"},"reference-count":28,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2017,9,25]],"date-time":"2017-09-25T00:00:00Z","timestamp":1506297600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100008450","name":"Biomet","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008450","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Knee Surg Sports Traumatol Arthrosc"],"published-print":{"date-parts":[[2018,6]]},"DOI":"10.1007\/s00167-017-4721-5","type":"journal-article","created":{"date-parts":[[2017,9,25]],"date-time":"2017-09-25T09:25:56Z","timestamp":1506331556000},"page":"1751-1758","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis"],"prefix":"10.1002","volume":"26","author":[{"given":"A. J.","family":"Kievit","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. G. G.","family":"Dobbe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G. J.","family":"Streekstra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.","family":"Blankevoort","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. U.","family":"Schafroth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,9,25]]},"reference":[{"key":"4721_CR1","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1007\/s00167-004-0533-5","volume":"13","author":"J Arora","year":"2005","unstructured":"Arora J, Sharma S, Blyth M (2005) The role of pre-operative templating in primary total knee replacement. Knee Surg Sport Traumatol Arthrosc 13:187\u2013189","journal-title":"Knee Surg Sport Traumatol Arthrosc"},{"key":"4721_CR2","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1111\/j.1365-2753.2004.00509.x","volume":"11","author":"N Aslam","year":"2005","unstructured":"Aslam N, Lo S (2005) Pre-operative planning and the role of templating in total knee arthroplasty. J Eval Clin Pract 11:93\u201394","journal-title":"J Eval Clin Pract"},{"key":"4721_CR3","first-page":"560","volume":"70","author":"N Aslam","year":"2004","unstructured":"Aslam N, Lo S, Nagarajah K, Pasapula C, Akmal M (2004) Reliability of preoperative templating in total knee arthroplasty. Acta Orthop Belg 70:560\u2013564","journal-title":"Acta Orthop Belg"},{"key":"4721_CR4","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1302\/0301-620X.94B11.30834","volume":"94","author":"RL Barrack","year":"2012","unstructured":"Barrack RL, Ruh EL, Williams BM, Ford AD, Foreman K, Nunley RM (2012) Patient specific cutting blocks are currently of no proven value. J Bone Joint Surg Br 94:95\u201399","journal-title":"J Bone Joint Surg Br"},{"key":"4721_CR5","doi-asserted-by":"crossref","first-page":"261","DOI":"10.2106\/JBJS.F.00601","volume":"89","author":"K Bauwens","year":"2007","unstructured":"Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A et al (2007) Navigated total knee replacement. A meta-analysis. J Bone Joint Surg Am 89:261\u2013269","journal-title":"J Bone Joint Surg Am"},{"key":"4721_CR6","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1302\/0301-620X.95B3.29903","volume":"95-B","author":"K Chareancholvanich","year":"2013","unstructured":"Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C (2013) A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J 95-B:354\u2013359","journal-title":"Bone Joint J"},{"key":"4721_CR7","doi-asserted-by":"crossref","first-page":"2194","DOI":"10.1007\/s00167-012-2098-z","volume":"21","author":"F Conteduca","year":"2013","unstructured":"Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G et al (2013) Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sport Traumatol Arthrosc 21:2194\u20132199","journal-title":"Knee Surg Sport Traumatol Arthrosc"},{"key":"4721_CR8","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1007\/s00264-012-1732-1","volume":"37","author":"K Daniilidis","year":"2013","unstructured":"Daniilidis K, Tibesku CO (2013) Frontal plane alignment after total knee arthroplasty using patient-specific instruments. Int Orthop 37:45\u201350","journal-title":"Int Orthop"},{"key":"4721_CR9","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1097\/00003086-199809000-00007","volume":"354","author":"SL Delp","year":"1998","unstructured":"Delp SL, Stulberg SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop Relat Res 354:49\u201356","journal-title":"Clin Orthop Relat Res"},{"key":"4721_CR10","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1109\/TBME.2010.2084576","volume":"58","author":"JG Dobbe","year":"2011","unstructured":"Dobbe JG, Strackee SD, Schreurs AW, Jonges R, Carelsen B, Vroemen JC et al (2011) Computer-assisted planning and navigation for corrective distal radius osteotomy, based on pre- and intraoperative imaging. IEEE Trans Biomed Eng 58:182\u2013190","journal-title":"IEEE Trans Biomed Eng"},{"key":"4721_CR11","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1016\/j.medengphy.2014.05.012","volume":"36","author":"JGG Dobbe","year":"2014","unstructured":"Dobbe JGG, Kievit AJ, Schafroth MU, Blankevoort L, Streekstra GJ (2014) Evaluation of a CT-based technique to measure the transfer accuracy of a virtually planned osteotomy. Med Eng Phys 36:1081\u20131087","journal-title":"Med Eng Phys"},{"key":"4721_CR12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3928\/01477447-20090728-29","volume":"32","author":"D Fang","year":"2009","unstructured":"Fang D, Ritter MA (2009) Malalignment: forewarned is forearmed. Orthopedics 32:1","journal-title":"Orthopedics"},{"key":"4721_CR13","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1097\/01.blo.0000201148.06454.ef","volume":"444","author":"MA Hafez","year":"2006","unstructured":"Hafez MA, Chelule KL, Seedhom BB, Sherman KP (2006) Computer-assisted total knee arthroplasty using patient-specific templating. Clin Orthop Relat Res 444:184\u2013192","journal-title":"Clin Orthop Relat Res"},{"key":"4721_CR14","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1054\/arth.2002.27258","volume":"17","author":"J Heal","year":"2002","unstructured":"Heal J, Blewitt N (2002) Kinemax total knee arthroplasty: trial by template. J Arthroplasty 17:90\u201394","journal-title":"J Arthroplasty"},{"key":"4721_CR15","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.knee.2012.10.009","volume":"21","author":"TJ Heyse","year":"2014","unstructured":"Heyse TJ, Tibesku CO (2014) Improved femoral component rotation in TKA using patient-specific instrumentation. Knee 21:268\u2013271","journal-title":"Knee"},{"key":"4721_CR16","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.knee.2006.05.002","volume":"13","author":"DW Howcroft","year":"2006","unstructured":"Howcroft DW, Fehily MJ, Peck C, Fox A, Dillon B, Johnson DS (2006) The role of preoperative templating in total knee arthroplasty: comparison of three prostheses. Knee 13:427\u2013429","journal-title":"Knee"},{"key":"4721_CR17","doi-asserted-by":"crossref","first-page":"165","DOI":"10.3109\/17453674.2013.785908","volume":"84","author":"B Kerens","year":"2013","unstructured":"Kerens B, Boonen B, Schotanus M, Kort N (2013) Patient-specific guide for revision of medial unicondylar knee arthroplasty to total knee arthroplasty. Acta Orthop 84:165\u2013169","journal-title":"Acta Orthop"},{"key":"4721_CR18","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.arth.2007.10.001","volume":"23","author":"BA Klatt","year":"2008","unstructured":"Klatt BA, Goyal N, Austin MS, Hozack WJ (2008) Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty 23:26\u201329","journal-title":"J Arthroplasty"},{"key":"4721_CR19","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1302\/0301-620X.94B11.29350","volume":"94","author":"SP Krishnan","year":"2012","unstructured":"Krishnan SP, Dawood A, Richards R, Henckel J, Hart AJ (2012) A review of rapid prototyped surgical guides for patient-specific total knee replacement. J Bone Joint Surg Br 94:1457\u20131461","journal-title":"J Bone Joint Surg Br"},{"key":"4721_CR20","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/j.arth.2012.07.012","volume":"28","author":"S Lustig","year":"2013","unstructured":"Lustig S, Scholes CJ, Oussedik SI, Kinzel V, Coolican MR, Parker DA (2013) Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. J Arthroplasty 28:469\u2013473","journal-title":"J Arthroplasty"},{"key":"4721_CR21","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.knee.2012.12.009","volume":"20","author":"D Nam","year":"2013","unstructured":"Nam D, Maher PA, Rebolledo BJ, Nawabi DH, McLawhorn AS, Pearle AD (2013) Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty. Knee 20:263\u2013267","journal-title":"Knee"},{"key":"4721_CR22","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1007\/s11999-011-1996-6","volume":"470","author":"VY Ng","year":"2012","unstructured":"Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99\u2013107","journal-title":"Clin Orthop Relat Res"},{"key":"4721_CR23","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1007\/s11999-011-2222-2","volume":"470","author":"RM Nunley","year":"2012","unstructured":"Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470:895\u2013902","journal-title":"Clin Orthop Relat Res"},{"key":"4721_CR24","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1007\/s00167-013-2639-0","volume":"22","author":"AF Silva","year":"2014","unstructured":"Silva AF, Sampaio RF, Pinto E (2014) Patient-specific instrumentation improves tibial component rotation in TKA. Knee Surg Sports Traumatol Arthrosc 22:636\u2013642","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"4721_CR25","doi-asserted-by":"crossref","first-page":"2227","DOI":"10.1007\/s00167-013-2626-5","volume":"21","author":"E Thienpont","year":"2013","unstructured":"Thienpont E, Bellemans J, Delport H, Van Overschelde P, Stuyts B, Brabants K et al (2013) Patient-specific instruments: industry\u2019s innovation with a surgeon\u2019s interest. Knee Surg Sport Traumatol Arthrosc 21:2227\u20132233","journal-title":"Knee Surg Sport Traumatol Arthrosc"},{"key":"4721_CR26","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1002\/rcs.201","volume":"4","author":"D White","year":"2008","unstructured":"White D, Chelule KL, Seedhom BB (2008) Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgery. Int J Med Robot 4:224\u2013231","journal-title":"Int J Med Robot"},{"key":"4721_CR27","first-page":"1237","volume":"2011","author":"W Wittmann","year":"2011","unstructured":"Wittmann W, Wenger T, Loewe E, Lueth TC (2011) Official measurement protocol and accuracy results for an optical surgical navigation system (NPU). Conf Proc IEEE Eng Med Biol Soc 2011:1237\u20131240","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"4721_CR28","doi-asserted-by":"crossref","first-page":"2841","DOI":"10.1007\/s00167-015-3949-1","volume":"25","author":"F Zambianchi","year":"2017","unstructured":"Zambianchi F, Colombelli A, Digennaro V, Marcovigi A, Mugnai R, Fiacchi F et al (2017) Assessment of patient-specific instrumentation precision through bone resection measurements. Knee Surg Sport Traumatol Arthrosc 25:2841\u20132848","journal-title":"Knee Surg Sport Traumatol Arthrosc"}],"container-title":["Knee Surgery, Sports Traumatology, Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00167-017-4721-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00167-017-4721-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00167-017-4721-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,15]],"date-time":"2023-12-15T19:17:37Z","timestamp":1702667857000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00167-017-4721-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9,25]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018,6]]}},"alternative-id":["4721"],"URL":"https:\/\/doi.org\/10.1007\/s00167-017-4721-5","relation":{},"ISSN":["0942-2056","1433-7347"],"issn-type":[{"value":"0942-2056","type":"print"},{"value":"1433-7347","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,9,25]]}}}