{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T00:26:41Z","timestamp":1793752001768,"version":"4.6.1"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,6,14]],"date-time":"2026-06-14T00:00:00Z","timestamp":1781395200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,14]],"date-time":"2026-06-14T00:00:00Z","timestamp":1781395200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Wake Forest University","id":[{"id":"https:\/\/ror.org\/0207ad724","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Urogynecol J"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction and Hypothesis<\/jats:title>\n                    <jats:p>Autologous pubovaginal slings are an important option for the management of stress urinary incontinence (SUI) but are associated with higher risks of voiding dysfunction. There is no standardized method for tensioning that balances the effectiveness of treatment with the prevention of voiding dysfunction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We present a video demonstrating the surgical steps of a novel combination of a fascia lata sling combined with an adjustable tensioning system, as well as an accompanying case series of short-term outcomes. The video demonstrates the use of this system for a 59-year-old female with chronic pain and tobacco use who presented with severe, recurrent SUI after Burch colposuspension.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In 2025, a total of 9 cases of fascial slings combined with the adjustable tensioning system were performed at this institution, with all patients demonstrating a negative cough stress test after tensioning and with no cases of postoperative urinary retention or voiding dysfunction at least 6\u00a0months postoperatively. Data collection for long-term outcomes is ongoing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The combination of an autologous fascial sling with a personalized adjustable tensioning system offers a unique modification to a commercially available system that may provide women with complex SUI and risk factors for mesh complications with a feasible way of achieving continence while mitigating the risks of voiding dysfunction typically seen with a fascial sling.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00192-026-06595-7","type":"journal-article","created":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T22:02:30Z","timestamp":1781388150000},"page":"3639-3642","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Adjustable Autologous Pubovaginal Sling for Complex Stress Urinary Incontinence: A Technical Surgical Video with a Case Series"],"prefix":"10.1007","volume":"37","author":[{"given":"Marisa N.","family":"Duong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christina M.","family":"Mezes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amr S.","family":"El Haraki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Catherine A.","family":"Matthews","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,14]]},"reference":[{"issue":"21","key":"6595_CR1","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.1056\/NEJMoa070416","volume":"356","author":"ME Albo","year":"2007","unstructured":"Albo ME, Richter HE, Brubaker L, Norton P, Kraus SR, Zimmern PE, et al. Burch colposuspension versus fascial sling to reduce urinary stress incontinence. N Engl J Med. 2007;356(21):2143\u201355. https:\/\/doi.org\/10.1056\/NEJMoa070416.","journal-title":"N Engl J Med"},{"issue":"2","key":"6595_CR2","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1007\/s00192-024-05916-y","volume":"36","author":"EA Brennand","year":"2025","unstructured":"Brennand EA, Chai J, Cummings S, Huang  B, Hughes  T, Edwards A, et al. Babcock versus scissor tensioning for retropubic mid-urethral slings: comparing two intra-operative techniques through 5 years of follow-up. Int Urogynecol J. 2025;36(2):279\u201387. https:\/\/doi.org\/10.1007\/s00192-024-05916-y.","journal-title":"Int Urogynecol J"},{"issue":"4","key":"6595_CR3","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.1002\/nau.23444","volume":"37","author":"C Errando-Smet","year":"2018","unstructured":"Errando-Smet C, Ruiz CG, Bertr\u00e1n PA, Mavrich HV. A re-adjustable sling for female recurrent stress incontinence and intrinsic sphincteric deficiency: long-term results in 205 patients using the Remeex sling system. Neurourol Urodyn. 2018;37(4):1349\u201355. https:\/\/doi.org\/10.1002\/nau.23444.","journal-title":"Neurourol Urodyn"},{"issue":"9","key":"6595_CR4","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1007\/s00192-018-3568-8","volume":"29","author":"M Plata","year":"2018","unstructured":"Plata M, Robledo D, Bravo-Balado A, Casta\u00f1o  JC, Osorio  C, Salazar M, et al. Effectiveness of the Remeex system\u2122 in Colombian women with recurrent stress urinary incontinence or intrinsic sphincter deficiency. Int Urogynecol J. 2018;29(9):1371\u20138. https:\/\/doi.org\/10.1007\/s00192-018-3568-8.","journal-title":"Int Urogynecol J"},{"issue":"2","key":"6595_CR5","doi-asserted-by":"publisher","first-page":"124","DOI":"10.4111\/kju.2014.55.2.124","volume":"55","author":"MY Seo","year":"2014","unstructured":"Seo MY, Noh JH. Long-term outcome of the readjustable sling procedure for female stress urinary incontinence with intrinsic sphincter deficiency or recurrence. Korean J Urol. 2014;55(2):124\u20138. https:\/\/doi.org\/10.4111\/kju.2014.55.2.124.","journal-title":"Korean J Urol"},{"issue":"3","key":"6595_CR6","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1002\/nau.23020","volume":"36","author":"C Giberti","year":"2017","unstructured":"Giberti C, Gallo F, Cortese P, Visalli F. Mid- to long-term results of the Remeex system for the treatment of female incontinence due to intrinsic sphincter deficiency: a retrospective analysis of the first 50 patients. Neurourol Urodyn. 2017;36(3):770\u20133. https:\/\/doi.org\/10.1002\/nau.23020.","journal-title":"Neurourol Urodyn"},{"issue":"1","key":"6595_CR7","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.urology.2014.10.003","volume":"85","author":"BH Park","year":"2015","unstructured":"Park BH, Kim JC, Kim HW, Kim YH, Choi JB, Lee DH. Midterm efficacy and complications of readjustable midurethral sling (Remeex system) in female stress urinary incontinence with recurrence or intrinsic sphincter deficiency. Urology. 2015;85(1):79\u201384. https:\/\/doi.org\/10.1016\/j.urology.2014.10.003.","journal-title":"Urology"},{"issue":"4","key":"6595_CR8","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1007\/s00192-021-04972-y","volume":"33","author":"C Ros","year":"2022","unstructured":"Ros C, Escura S, Angl\u00e8s-Acedo S, Larroya  M, Bataller  E, Amat L, et al. Mid-term results of the Remeex\u00ae readjustable sling for female complex stress urinary incontinence and sonographic hypomobile urethra. Int Urogynecol J. 2022;33(4):903\u201310. https:\/\/doi.org\/10.1007\/s00192-021-04972-y.","journal-title":"Int Urogynecol J"},{"issue":"3","key":"6595_CR9","doi-asserted-by":"publisher","first-page":"S941","DOI":"10.1016\/j.ajog.2022.12.262","volume":"228","author":"CK Pfeuti","year":"2023","unstructured":"Pfeuti CK, Clark GV, Smith D, Vakili B. Adjustable autologous pubovaginal sling. Am J Obstet Gynecol. 2023;228(3):S941. https:\/\/doi.org\/10.1016\/j.ajog.2022.12.262.","journal-title":"Am J Obstet Gynecol"},{"issue":"6","key":"6595_CR10","doi-asserted-by":"publisher","first-page":"2299","DOI":"10.1097\/01.ju.0000056728.52215.d7","volume":"169","author":"A Gomelsky","year":"2003","unstructured":"Gomelsky A, Dmochowski RR. Incisional bladder hernia after rectus fascial sling. J Urol. 2003;169(6):2299. https:\/\/doi.org\/10.1097\/01.ju.0000056728.52215.d7.","journal-title":"J Urol"},{"issue":"5","key":"6595_CR11","doi-asserted-by":"publisher","first-page":"1185","DOI":"10.1002\/nau.25462","volume":"43","author":"C Johnson","year":"2024","unstructured":"Johnson C, Vollstedt A, Nakatsuka H, Orzel J, Takacs EB. Cosmetic and functional impact of fascia lata harvest for use in surgery for stress urinary incontinence. Neurourol Urodyn. 2024;43(5):1185\u201391. https:\/\/doi.org\/10.1002\/nau.25462.","journal-title":"Neurourol Urodyn"},{"issue":"2","key":"6595_CR12","doi-asserted-by":"publisher","first-page":"116","DOI":"10.5213\/inj.1732682.341","volume":"21","author":"KJ Ko","year":"2017","unstructured":"Ko KJ, Suh YS, Sung HH, Ryu GH, Lee M, Lee KS. Assessing the readjustable sling procedure (Remeex System) for female stress urinary incontinence with detrusor underactivity. Int Neurourol J. 2017;21(2):116\u201320. https:\/\/doi.org\/10.5213\/inj.1732682.341.","journal-title":"Int Neurourol J"}],"container-title":["International Urogynecology Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00192-026-06595-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00192-026-06595-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00192-026-06595-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T00:04:23Z","timestamp":1793750663000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00192-026-06595-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,14]]},"references-count":12,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["6595"],"URL":"https:\/\/doi.org\/10.1007\/s00192-026-06595-7","relation":{},"ISSN":["0937-3462","1433-3023"],"issn-type":[{"value":"0937-3462","type":"print"},{"value":"1433-3023","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,14]]},"assertion":[{"value":"11 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Catherine Matthews: grant support from Coloplast and Boston Scientific; consultant to Coloplast; honoraria from Neomedic; expert witness Johnson & Johnson.","order":1,"name":"Ethics","label":"Conflicts of Interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written informed consent was obtained from the patient and from all patients included in the case series for publication of this video article and any accompanying images.","order":2,"name":"Ethics","label":"Consent","group":{"name":"EthicsHeading","label":"Declarations"}}]}}