{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T15:06:38Z","timestamp":1784819198443,"version":"3.55.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"S02","license":[{"start":{"date-parts":[[2004,10,27]],"date-time":"2004-10-27T00:00:00Z","timestamp":1098835200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Osteoporos Int"],"published-print":{"date-parts":[[2005,3]]},"DOI":"10.1007\/s00198-004-1777-0","type":"journal-article","created":{"date-parts":[[2004,10,26]],"date-time":"2004-10-26T13:56:21Z","timestamp":1098798981000},"page":"S107-S111","source":"Crossref","is-referenced-by-count":97,"title":["Mechanical behavior of screws in normal and osteoporotic bone"],"prefix":"10.1007","volume":"16","author":[{"given":"J.","family":"Seebeck","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Goldhahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. M.","family":"Morlock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2004,10,27]]},"reference":[{"key":"CR1","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1097\/00005131-199610000-00003","volume":"10","author":"Asnis","year":"1996","unstructured":"Asnis SE, Ernberg JJ, Bostrom MP, Wright TM, Harrington RM, Tencer A, Peterson M (1996) Cancellous bone screw thread design and holding power. J Orthop Trauma 10:462\u2013469","journal-title":"J Orthop Trauma"},{"key":"CR2","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1007\/BF00347258","volume":"5","author":"Bloom","year":"1980","unstructured":"Bloom RA (1980) A comparative estimation of the combined cortical thickness of various bone sites. Skeletal Radiol 5:167\u2013170","journal-title":"Skeletal Radiol"},{"key":"CR3","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1002\/jor.1100180220","volume":"18","author":"Brown","year":"2000","unstructured":"Brown GA, McCarthy T, Bourgeault CA, Callahan DJ (2000) Mechanical performance of standard and cannulated 4.0-mm cancellous bone screws. J Orthop Res 18:307\u2013312","journal-title":"J Orthop Res"},{"key":"CR4","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1115\/1.2796022","volume":"118","author":"Chapman","year":"1996","unstructured":"Chapman JR, Harrington RM, Lee KM, Anderson PA, Tencer AF, Kowalski D (1996) Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 118:391\u2013398","journal-title":"J Biomech Eng"},{"key":"CR5","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1097\/00005131-199004020-00012","volume":"4","author":"DeCoster","year":"1990","unstructured":"DeCoster TA, Heetderks DB, Downey DJ, Ferries JS, Jones W (1990) Optimizing bone screw pullout force. J Orthop Trauma 4:169\u2013174","journal-title":"J Orthop Trauma"},{"key":"CR6","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1359\/jbmr.2002.17.1.162","volume":"17","author":"Eckstein","year":"2002","unstructured":"Eckstein F, Lochmuller EM, Lill CA, Kuhn V, Schneider E, Delling G, Muller R (2002) Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry. J Bone Miner Res 17:162\u2013171","journal-title":"J Bone Miner Res"},{"key":"CR7","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1016\/S0021-9290(99)00076-7","volume":"32","author":"Faran","year":"1999","unstructured":"Faran KJ, Ichioka N, Trzeciak MA, Han S, Medige J, Moy OJ (1999) Effect of bone quality on the forces generated by compression screws. J Biomech 32:861\u2013864","journal-title":"J Biomech"},{"key":"CR8","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0020-1383(01)00127-9","volume":"32","author":"Frigg","year":"2001","unstructured":"Frigg R (2001) Locking compression plate (LCP): an osteosynthesis plate based on the dynamic compression plate and the Point Contact Fixator (PC-Fix). Injury 32 (Suppl) 2:63\u201366","journal-title":"Injury"},{"key":"CR9","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1016\/S0268-0033(98)00107-7","volume":"14","author":"Harnroongroj","year":"1999","unstructured":"Harnroongroj T, Techataweewan A (1999) Determination of the role of the cancellous bone in generation of screw holding power at metaphysis. Clin Biomech 14:364\u2013366","journal-title":"Clin Biomech"},{"key":"CR10","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1007\/s001170050494","volume":"39","author":"Jergas","year":"1999","unstructured":"Jergas M, Schmid G (1999) Conventional radiology of osteoporosis and radiographic absorptiometry. Radiologe 39:174\u2013185","journal-title":"Radiologe"},{"key":"CR11","doi-asserted-by":"crossref","first-page":"183","DOI":"10.3109\/10929080109146082","volume":"6","author":"Messmer","year":"2001","unstructured":"Messmer P, Long G, Suhm N, Regazzoni P, Jacob AL (2001) Volumetric model determination of the tibia based on 2D radiographs using a 2D\/3D database. Comput Aided Surg 6:183\u2013194","journal-title":"Comput Aided Surg"},{"key":"CR12","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/S0169-6009(08)80213-9","volume":"27","author":"Pearson","year":"1994","unstructured":"Pearson J, Ruegsegger P, Dequeker J, Henley M, Bright J, Reeve J, Kalender W, Felsenberg D, Laval-Jeantet AM, Adams JE (1994) European semi-anthropomorphic phantom for the cross-calibration of peripheral bone densitometers: assessment of precision accuracy and stability. Bone Miner 27:109\u2013120","journal-title":"Bone Miner"},{"key":"CR13","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1088\/0031-9155\/44\/3\/017","volume":"44","author":"Prevrhal","year":"1999","unstructured":"Prevrhal S, Engelke K, Kalender WA (1999) Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters. Phys Med Biol 44:751\u2013764","journal-title":"Phys Med Biol"},{"key":"CR14","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1002\/jor.1100090315","volume":"9","author":"Snyder","year":"1991","unstructured":"Snyder SM, Schneider E (1991) Estimation of mechanical properties of cortical bone by computed tomography. J Orthop Res 9:422\u2013431","journal-title":"J Orthop Res"},{"key":"CR15","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1016\/0020-1383(93)90314-V","volume":"24","author":"Stromsoe","year":"1993","unstructured":"Stromsoe K, Kok WL, Hoiseth A, Alho A (1993) Holding power of the 4.5\u00a0mm AO\/ASIF cortex screw in cortical bone in relation to bone mineral. Injury 24:656\u2013659","journal-title":"Injury"}],"container-title":["Osteoporosis International"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00198-004-1777-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00198-004-1777-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00198-004-1777-0","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,23]],"date-time":"2019-05-23T11:03:51Z","timestamp":1558609431000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00198-004-1777-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,10,27]]},"references-count":15,"journal-issue":{"issue":"S02","published-print":{"date-parts":[[2005,3]]}},"alternative-id":["1777"],"URL":"https:\/\/doi.org\/10.1007\/s00198-004-1777-0","relation":{},"ISSN":["0937-941X","1433-2965"],"issn-type":[{"value":"0937-941X","type":"print"},{"value":"1433-2965","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,10,27]]}}}