{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T18:43:07Z","timestamp":1788028987281,"version":"build-2784847793"},"reference-count":164,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,1,19]],"date-time":"2025-01-19T00:00:00Z","timestamp":1737244800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,1,19]],"date-time":"2025-01-19T00:00:00Z","timestamp":1737244800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Toxicol"],"published-print":{"date-parts":[[2025,3]]},"DOI":"10.1007\/s00204-024-03946-5","type":"journal-article","created":{"date-parts":[[2025,1,19]],"date-time":"2025-01-19T16:38:47Z","timestamp":1737304727000},"page":"865-885","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Formaldehyde and asthma: a plausibility?"],"prefix":"10.1007","volume":"99","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1933-7351","authenticated-orcid":false,"given":"Peder","family":"Wolkoff","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,1,19]]},"reference":[{"key":"3946_CR1","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1093\/chemse\/bjr094","volume":"37","author":"MH Abraham","year":"2012","unstructured":"Abraham MH, S\u00e1nchez-Moreno R, Cometto-Mu\u00f1iz JE, Cain WS (2012) An algorithm for 353 odor detection thresholds in humans. Chem Senses 37:207\u2013218","journal-title":"Chem Senses"},{"key":"3946_CR2","doi-asserted-by":"publisher","first-page":"1761","DOI":"10.1111\/all.16051","volume":"79","author":"I Agache","year":"2024","unstructured":"Agache I, Canelo-Aybar C, Annesi-Maesano I, Cecchi L, Biagioni B, Chung F, D\u2019Amato G, Damialis A, Del Giacco S et al (2024) The impact of indoor air pollution on asthma-related outcomes: a systematic review for the EAACI guidelines on environmental science for allergic diseases and asthma. Allergy 79:1761\u20131788","journal-title":"Allergy"},{"key":"3946_CR3","doi-asserted-by":"publisher","first-page":"38","DOI":"10.2500\/ajr.2008.22.3117","volume":"22","author":"LK Airaksinen","year":"2008","unstructured":"Airaksinen LK, Tuomi TO, Tuppurainen MO, Lauerma AT, Toskalae M (2008) Inhalation challenge test in the diagnosis of occupational rhinitis. Am J Rhinol 22:38\u201346","journal-title":"Am J Rhinol"},{"key":"3946_CR4","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1136\/oem.54.5.296","volume":"54","author":"F Akbar-Khanzadeh","year":"1997","unstructured":"Akbar-Khanzadeh F, Mlynek JS (1997) Changes in respiratory function after one and three hours of exposure for formaldehyde in non-smoking subjects. Occup Environ Med 54:296\u2013300","journal-title":"Occup Environ Med"},{"key":"3946_CR5","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s002040050502","volume":"72","author":"Y Alarie","year":"1998","unstructured":"Alarie Y (1998) Computer-based bioassay for evaluation of sensory irritation of airborne chemicals and its limit of detection. Arch Toxicol 72:277\u2013282","journal-title":"Arch Toxicol"},{"key":"3946_CR6","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1136\/thoraxjnl-2011-200391","volume":"68","author":"I Annesi-Maessano","year":"2012","unstructured":"Annesi-Maessano I, Hulin M, Lavaud F, Raherison C, Kopferschmitt C, de Blay F, Charpin DA, Denis C (2012) Poor air quality in classrooms related to asthma and rhinitis in primary schoolchildren of the French 6 Cities study. Thorax 68:682\u2013688","journal-title":"Thorax"},{"key":"3946_CR7","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.scitotenv.2012.02.026","volume":"423","author":"A Araki","year":"2012","unstructured":"Araki A, Kanazawa A, Kawai T, Eitaki Y, Morimoto K, Nakayama K, Shibata E, Tanaka M, Takigawa T, Yoshimura T, Chikara H, Saijo Y, Kishi R (2012) The relationship between exposure to microbial volatile organic compound and allergy prevalence in single-family houses. Sci Total Environ 423:18\u201326","journal-title":"Sci Total Environ"},{"key":"3946_CR8","doi-asserted-by":"publisher","first-page":"182","DOI":"10.3109\/08958378.2012.654857","volume":"24","author":"B Asgharin","year":"2012","unstructured":"Asgharin B, Price OT, Schroeter JD, Kimbell JS, Singal M (2012) A lung dosimetry model of vapor uptake and tissue disposition. Inhal Toxicol 24:182\u2013193","journal-title":"Inhal Toxicol"},{"key":"3946_CR9","volume":"16","author":"HK Austin","year":"2024","unstructured":"Austin HK, Schoenberg E (2024) A comprehensive literature review on the effects of formaldehyde on the upper respiratory tract. Cureus 16:e59743","journal-title":"Cureus"},{"key":"3946_CR10","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.2105\/AJPH.72.11.1283","volume":"72","author":"HE Ayer","year":"1982","unstructured":"Ayer HE, Yeager DW (1982) Irritants in cigarette smoke plumes. Am J Pub Health 72:1283\u20131285","journal-title":"Am J Pub Health"},{"key":"3946_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijheh.2020.113470","volume":"225","author":"K Azuma","year":"2020","unstructured":"Azuma K, Jinno H, Tanaka-Kagawa T, Sakai S (2020) Risk assessment concepts and approaches for indoor air chemicals in Japan. Int J Hyg Environ Health 225:113470","journal-title":"Int J Hyg Environ Health"},{"key":"3946_CR12","first-page":"404","volume":"49","author":"K Baba","year":"2000","unstructured":"Baba K, Yagi T, Sakakibara A, Hattori T, Koishikawa I, Yoshida K, Kobayashi T (2000) Measurements of formaldehyde-specific IgE antibodies in adult asthmatics. Arerugi 49:404\u2013411","journal-title":"Arerugi"},{"key":"3946_CR13","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/1745-6673-7-19","volume":"7","author":"X Baur","year":"2012","unstructured":"Baur X, Bakehe P, Vellguth H (2012) Bronchial asthma and COPD due to irritants in the workplace - an evidence-based approach. J Occup Med Toxicol 7:19","journal-title":"J Occup Med Toxicol"},{"key":"3946_CR14","doi-asserted-by":"publisher","first-page":"1342","DOI":"10.1002\/mnfr.201100279","volume":"55","author":"K Bein","year":"2011","unstructured":"Bein K, Leikauf GD (2011) Acrolein - a pulmonary hazard. Mol Nutr Food Res 55:1342\u20131360","journal-title":"Mol Nutr Food Res"},{"key":"3946_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.cbi.2024.111002","volume":"394","author":"AA Bhat","year":"2024","unstructured":"Bhat AA, Afzal M, Goyal A, Gupta G, Thapa R, Almalki WH, Kazmi I, Alzarea SI, Shahwan M, Paudel KR, Ali H, Sahu D, Prasher P, Singh SK, Dua K (2024) The impact of formaldehyde exposure on lung inflammatory disorders: insights into asthma, bronchitis, and pulmonary fibrosis. Chem-Biol Intact 394:111002","journal-title":"Chem-Biol Intact"},{"key":"3946_CR16","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1016\/j.envres.2011.02.008","volume":"111","author":"C Billionnet","year":"2011","unstructured":"Billionnet C, Gay E, Kirchner S, Leynaert B, Annesi-Maessano I (2011) Quantitative assessments of indoor air pollution and respiratory health in a population-based sample of french dwellings. Environ Res 111:425\u2013434","journal-title":"Environ Res"},{"key":"3946_CR17","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1111\/j.1365-2222.1995.tb01073.x","volume":"25","author":"E Bj\u00f6rnsson","year":"1995","unstructured":"Bj\u00f6rnsson E, Norb\u00e4ck D, Janson C, Widstr\u00f6m J, Palmgren U, Str\u00f6m G, Boman G (1995) Asthmatic symptoms and indoor levels of micro-organisms and house dust mites. Clin Exp Allergy 25:423\u2013431","journal-title":"Clin Exp Allergy"},{"key":"3946_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.scitotenv.2020.140982","volume":"745","author":"PTBS Branco","year":"2020","unstructured":"Branco PTBS, Alvim-Ferraz MCM, Martins FG, Ferraz C, Vaz LG, Sousa SIV (2020) Impact of indoor air pollution in nursery and primary schools on childhood asthma. Sci Total Environ 745:140982","journal-title":"Sci Total Environ"},{"issue":"Suppl 1","key":"3946_CR165","doi-asserted-by":"publisher","first-page":"S27","DOI":"10.1002\/alr.21597","volume":"5","author":"EP Brigham","year":"2015","unstructured":"Brigham EP, West NE (2015) Diagnosis of asthma: diagnostic testing. Int Forum Allergy Rhinol 5(Suppl 1):S27\u2013S30. https:\/\/doi.org\/10.1002\/alr.21597","journal-title":"Int Forum Allergy Rhinol"},{"key":"3946_CR19","doi-asserted-by":"publisher","first-page":"1855","DOI":"10.1007\/s00204-014-1346-z","volume":"88","author":"T Br\u00fcning","year":"2014","unstructured":"Br\u00fcning T, Bartsch R, Bolt HM, Desel H, Drexler H, Gundert-Remy U, Hartwig A, J\u00e4ckh R, Leibold E, Pallapies D, Rettenmeier AW, Schl\u00fcter G, Stropp G, Sucker K, Triebig G, Westphal G, van Thriel C (2014) Sensory irritation as a basis for setting occupational exposure limits. Arch Toxicol 88:1855\u20131879","journal-title":"Arch Toxicol"},{"key":"3946_CR20","doi-asserted-by":"publisher","first-page":"1344","DOI":"10.1111\/j.1398-9995.2006.01174.x","volume":"61","author":"A Casset","year":"2006","unstructured":"Casset A, Marchand C, Purohit A, le Calve S, Uring-Lambert B, Donnay C, Meyer P, de Blay F (2006) Inhaled formaldehyde exposure: effect on bronchial response to mite allergen in sensitized asthma patients. Allergy 61:1344\u20131350","journal-title":"Allergy"},{"key":"3946_CR21","doi-asserted-by":"publisher","first-page":"D1","DOI":"10.1080\/15459624.2012.635131","volume":"9","author":"DM Ceballos","year":"2012","unstructured":"Ceballos DM, Burr GA (2012) Evaluating a persistent nuisance odor in an office building. J Occup Environ Hyg 9:D1\u2013D6","journal-title":"J Occup Environ Hyg"},{"key":"3946_CR22","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1080\/07448481.1992.9936310","volume":"41","author":"S-E Chia","year":"1992","unstructured":"Chia S-E, Ong C-N, Foo SC, Lee HP (1992) Medical students\u2019 exposure to formaldehyde in a gross anatomy dissection laboratory. J Am Coll Health 41:115\u2013119","journal-title":"J Am Coll Health"},{"key":"3946_CR23","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.etap.2016.05.011","volume":"45","author":"A-S Claeson","year":"2016","unstructured":"Claeson A-S, Lind N (2016) Human exposure to Acrolein: time-dependence and individual variation in eye irritation. Environ Toxicol Pharmacol 45:20\u201327","journal-title":"Environ Toxicol Pharmacol"},{"key":"3946_CR24","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1016\/0091-3057(91)90063-8","volume":"39","author":"JE Cometto-Mu\u00f1iz","year":"1991","unstructured":"Cometto-Mu\u00f1iz JE, Cain WS (1991) Nasal pungency, odor, and eye iritation thresholds for homologous acetates. Pharmacol Biochem & Behavior 39:983\u2013989","journal-title":"Pharmacol Biochem & Behavior"},{"key":"3946_CR25","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1177\/0748233717750982","volume":"34","author":"JG Dahlgren","year":"2018","unstructured":"Dahlgren JG, Talbott PJ (2018) Asthma from hair straightening treatment containing formaldehyde: two cases and review of the literature. Toxicol Ind Health 34:262\u2013269","journal-title":"Toxicol Ind Health"},{"key":"3946_CR26","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1034\/j.1398-9995.2003.00044.x","volume":"58","author":"S Doi","year":"2003","unstructured":"Doi S, Suzuki S, Morishita M, Yamada M, Kanda Y, Torii S, Sakamoto T (2003) The prevalence of IgE sensitization to formaldehyde in asthmatic children. Allergy 58:668\u2013671","journal-title":"Allergy"},{"key":"3946_CR27","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1080\/10408440490269586","volume":"34","author":"RL Doty","year":"2004","unstructured":"Doty RL, Cometto-Mu\u00f1iz JE, Jalowayski AA, Dalton P, Kendall-Reed M, Hodgson M (2004) Assessment of upper respiratory tract and ocular irritative effects of volatile chemicals in humans. Crit Rev Toxicol 34:85\u2013142","journal-title":"Crit Rev Toxicol"},{"key":"3946_CR28","doi-asserted-by":"publisher","DOI":"10.1016\/j.envpol.2019.113375","volume":"256","author":"J Duan","year":"2020","unstructured":"Duan J, Xie J, Deng T, Xie X, Liu H, Li B, Chen M (2020) Exposure to formaldehyde and high relative humidity exacerbates allergic asthma by activating the TRPV4-P38 MAPK pathway in Balb\/c Mice. Environ Pollut 256:113375","journal-title":"Environ Pollut"},{"key":"3946_CR29","doi-asserted-by":"publisher","first-page":"810","DOI":"10.3109\/08958378.2015.1115567","volume":"27","author":"AM Dwivedi","year":"2015","unstructured":"Dwivedi AM, Johanson G, Lorentzen JC, Palmberg L, Sj\u00f6gren B, Ernstg\u00e5rd L (2015) Acute effects of acrolein in human volunteers during controlled exposure. Inhal Toxicol 27:810\u2013821","journal-title":"Inhal Toxicol"},{"key":"3946_CR30","unstructured":"ECHA (2019) Substance evaluation report conclusion as required by REACH Article 48 and evaluation report for formaldehyde. EC No 200-001-8, 1\u201357."},{"key":"3946_CR31","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1080\/00039896.1972.10666147","volume":"25","author":"JL Egle","year":"1972","unstructured":"Egle JL (1972) Retention of formaldehyde, propionaldehyde and acrolein in the dog. Arch Environ Health 25:119\u2013124","journal-title":"Arch Environ Health"},{"key":"3946_CR32","unstructured":"EU-LCI Group. Agreed EU-LCI values (December 2023). 2023. Brussels, European Commision, Internal Market, Industry, Entrepreneurship, and SMEs."},{"key":"3946_CR33","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1289\/ehp.9414","volume":"115","author":"V Ezratty","year":"2007","unstructured":"Ezratty V, Bonay M, Neikirch C, Orset-Guillossou G, Dehoux M, Koscielny S, Cabanes P-A, Lambrozo J, Aubier M (2007) Effect of formaldehyde on asthmatic responses to inhaled allergen challenge. Environ Health Perspec 115:210\u2013214","journal-title":"Environ Health Perspec"},{"key":"3946_CR34","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1111\/ina.12161","volume":"25","author":"MO Fadeyi","year":"2015","unstructured":"Fadeyi MO, Tham KW, Wu WY (2015) Impact of asthma, exposure period and filters on human responses during exposures to ozone and its initiated chemistry products. Indoor Air 25:512\u2013522","journal-title":"Indoor Air"},{"key":"3946_CR35","doi-asserted-by":"publisher","DOI":"10.1111\/ina.13141","volume":"32","author":"L Fang","year":"2022","unstructured":"Fang L, Liu N, Liu W, Mo J, Zhao Z, Kan H, Deng F, Huang C, Zhao B, Zeng X, Sun Y, Qian H, Sun C, Guo J, Zheng X, Zhang Y (2022) Indoor formaldehyde levels in residences, schools, and offices in china in the past 30 years: a systematic review. Indoor Air 32:e13141","journal-title":"Indoor Air"},{"key":"3946_CR36","doi-asserted-by":"publisher","DOI":"10.1183\/20734735.0002-2023","volume":"19","author":"J Feary","year":"2023","unstructured":"Feary J, Lindstrom I, Huntley CC, Suajalehto H, de la Hoz RE (2023) Occupational lung disease: when should i think of it and why is it important? Breathe 19:230002","journal-title":"Breathe"},{"key":"3946_CR37","volume":"15","author":"DA Forero","year":"2019","unstructured":"Forero DA, Lopez-Leon S, Gonz\u00e1lez-Giraldo Y, Bagos PG (2019) Ten rules for carrying out and writing meta-analyses. PLoS ONE 15:e1006922","journal-title":"PLoS ONE"},{"key":"3946_CR38","first-page":"287","volume":"47","author":"W Fransman","year":"2003","unstructured":"Fransman W, McLean D, Douwes J, Demers PA, Leung V, Pearce N (2003) Respiratory symptoms and occupational exposure in new zealand plywood mill workers. Ann Occup Hyg 47:287\u2013295","journal-title":"Ann Occup Hyg"},{"key":"3946_CR39","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/S0025-6196(12)61423-2","volume":"59","author":"E Frigas","year":"1984","unstructured":"Frigas E, Filley WV, Reed CE (1984) Bronchial challenge with formaldehyde gas: lack of bronchoconstriction in 13 patients suspected of having formaldehyde-induced asthma. Mayo Clin Proc 59:295\u2013299","journal-title":"Mayo Clin Proc"},{"key":"3946_CR40","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.1007\/s00103-016-2388-6","volume":"59","author":"H Fromme","year":"2016","unstructured":"Fromme H, Sagunski H (2016) Zur Frage Eines Asthma Ausl\u00f6senden Bzw. Verschlechternden Potenzials Von Formaldehyd in Der Innenraumluft Bei Kindern. Bundesgesundhbl 59:1028\u20131039","journal-title":"Bundesgesundhbl"},{"key":"3946_CR41","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.tox.2003.11.015","volume":"197","author":"H Fujimaki","year":"2004","unstructured":"Fujimaki H, Kurokawa Y, Kunugita N, Kikuchi M, Sato F, Arashidani K (2004) Differential immunogenic and neurogenic inflammatory responses in an allergic mouse model exposed to low levels of formaldehyde. Toxicology 197:1\u201313","journal-title":"Toxicology"},{"key":"3946_CR42","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1080\/08958370802320186","volume":"21","author":"GJM Garcia","year":"2009","unstructured":"Garcia GJM, Schroter JD, Segal RA, Stanek J, Foureman GL, Kimbell JS (2009) Dosimetry of nasal uptake of water-soluble and reactive gases: a first study of interhuman variability. Inhal Toxicol 21:607\u2013618","journal-title":"Inhal Toxicol"},{"key":"3946_CR43","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1046\/j.1365-2222.1998.00255.x","volume":"28","author":"MH Garrett","year":"1998","unstructured":"Garrett MH, Rayment PR, Hooper MA, Abramson MJ, Hooper BM (1998) Indoor airborne fungal spores, house dampness and associations with environmental factors and respiratory health in children. Clin Exp Allergy 28:459\u2013467","journal-title":"Clin Exp Allergy"},{"key":"3946_CR44","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1034\/j.1398-9995.1999.00763.x","volume":"54","author":"MH Garrett","year":"1999","unstructured":"Garrett MH, Hooper MA, Hooper BM, Rayment PR, Abramson MJ (1999) Increased risk of allergy in children due to formaldehyde exposure. Allergy 54:330\u2013337","journal-title":"Allergy"},{"key":"3946_CR45","doi-asserted-by":"publisher","first-page":"3676","DOI":"10.1016\/j.atmosenv.2011.04.037","volume":"45","author":"O Geiss","year":"2011","unstructured":"Geiss O, Giannopoulos G, Tirendi S, Barrero-Moreno J, Larsen BR, Kotzias D (2011) The AIRMEX Study - VOC measurements in public buildings and Schools\/Kindergartens in eleven European cities: statistical analysis of the Data. Atmos Environ 45:3676\u20133684","journal-title":"Atmos Environ"},{"key":"3946_CR46","first-page":"157","volume-title":"Environmental Burden of Disease Associated With Inadequate Housing","author":"NL Gilbert","year":"2011","unstructured":"Gilbert NL, Guay M (2011) Formaldehyde and respiratory symptoms in children. In: Braubach M, Jacobs DE, Ormanly D (eds) Environmental Burden of Disease Associated With Inadequate Housing. WHO Regional Office for Europe, Copenhagen, pp 157\u2013164"},{"key":"3946_CR47","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.envres.2004.09.009","volume":"99","author":"NL Gilbert","year":"2005","unstructured":"Gilbert NL, Guay M, Miller JD, Judek S, Chan CC, Dales RE (2005) Levels and determinants of formaldehyde, acetaldehyde and acrolein in residential indoor air in Prince Edward Island, Canada. Environ Res 99:11\u201317","journal-title":"Environ Res"},{"key":"3946_CR48","doi-asserted-by":"publisher","first-page":"2424","DOI":"10.1016\/j.atmosenv.2007.12.017","volume":"42","author":"NL Gilbert","year":"2008","unstructured":"Gilbert NL, Guay M, Gavin D, Dietz RN, Chan CC, L\u00e9vesque B (2008) Air change rate and concentration of formaldehyde in residential indoor air. Atmos Environ 42:2424\u20132428","journal-title":"Atmos Environ"},{"key":"3946_CR49","doi-asserted-by":"publisher","first-page":"672","DOI":"10.3109\/10408444.2011.573467","volume":"41","author":"R Golden","year":"2011","unstructured":"Golden R (2011) Identifying an indoor air exposure limit for formaldehyde considering both irritation and cancer hazards. Crit Rev Toxicol 41:672\u2013721","journal-title":"Crit Rev Toxicol"},{"key":"3946_CR50","doi-asserted-by":"publisher","first-page":"155932581769115","DOI":"10.1177\/1559325817691159","volume":"15","author":"R Golden","year":"2017","unstructured":"Golden R, Holm S (2017) Indoor air quality and asthma: has unrecognized exposure to acrolein confounded previous results? Dose-Response 15:1559325817691159","journal-title":"Dose-Response"},{"key":"3946_CR51","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/0091-6749(93)90033-C","volume":"92","author":"LC Grammer","year":"1993","unstructured":"Grammer LC, Harris KE, Cugell DW, Patterson R (1993) Evaluation of a worker with possible formaldehyde-induced asthma. J Allergy Clin Immun 92:33","journal-title":"J Allergy Clin Immun"},{"key":"3946_CR52","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1080\/15287398909531347","volume":"28","author":"DJ Green","year":"1989","unstructured":"Green DJ, Bascom R, Healey EM, Hebel JR, Sauder LR, Kulle TJ (1989) Acute pulmonary response in healthy, nonsmoking adults to inhalation of formaldehyde and carbon. J Toxicol Environ Health 28:261\u2013275","journal-title":"J Toxicol Environ Health"},{"key":"3946_CR53","doi-asserted-by":"publisher","DOI":"10.1016\/j.scitotenv.2022.156201","volume":"839","author":"CH Halios","year":"2022","unstructured":"Halios CH, Landeg-Cox C, Lowther SD, Middleton A, Marczylo T, Dimitroulopoulou S (2022) Chemicals in Europan residences - Part 1: a review of emissions, concentrations and health effects of volatile organic compounds (VOCs). Sci Total Environ 839:156201","journal-title":"Sci Total Environ"},{"key":"3946_CR54","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1007\/BF02719669","volume":"168","author":"H Harving","year":"1990","unstructured":"Harving H, Korsgaard J, Pedersen OF, M\u00f8lhave L, Dahl R (1990) Pulmonary function and bronchial reactivity in asthmatics during low-level formaldehyde exposure. Lung 168:15\u201321","journal-title":"Lung"},{"key":"3946_CR55","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ijheh.2010.08.009","volume":"214","author":"J Heinrich","year":"2011","unstructured":"Heinrich J (2011) Influence of indoor factors in dwellings on the development of childhood asthma. Int J Hyg Environ Health 214:1\u201325","journal-title":"Int J Hyg Environ Health"},{"key":"3946_CR56","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1016\/0278-6915(96)00012-9","volume":"34","author":"J Hilton","year":"1996","unstructured":"Hilton J, Dearman RJ, Basketter DA, Scholes EW, Kimber I (1996) Experimental assessment of the sensitizing properties of formaldehyde. Food Chem Toxicol 34:571\u2013578","journal-title":"Food Chem Toxicol"},{"key":"3946_CR57","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1039\/b200998f","volume":"4","author":"SSH Ho","year":"2002","unstructured":"Ho SSH, Yu JZ (2002) Concentrations of formaldehyde and other carbonyls in environments affected by incense burning. J Environ Monit 4:728\u2013733","journal-title":"J Environ Monit"},{"key":"3946_CR58","first-page":"15025","volume":"1","author":"ST Holgate","year":"2015","unstructured":"Holgate ST, Wenzel S, Postma DS, Weiss ST, Renz H (2015) Asthma. Nature Rev 1:15025","journal-title":"Nature Rev"},{"key":"3946_CR59","doi-asserted-by":"publisher","first-page":"120","DOI":"10.3109\/00016488909127488","volume":"107","author":"M Holmstr\u00f6m","year":"1989","unstructured":"Holmstr\u00f6m M, Wilhelmsson B, Hellquist H, Ros\u00e9n G (1989) Histological changes in the nasal mucosa in persons occupationally exposed to formaldehyde alone and in combination with wood dust. Acta Otolaryngol 107:120\u2013129","journal-title":"Acta Otolaryngol"},{"key":"3946_CR60","doi-asserted-by":"publisher","DOI":"10.1183\/16000617.0009-2023","volume":"32","author":"JC Holtjer","year":"2023","unstructured":"Holtjer JC, Bloemsma LD, Beijers RJHCG, Cornelissen MEB, Hilvering B, Houweling L, Vermeulen RCH, Downward GS (2023) Identifying risk factors for CORD and adult-onset asthma: an umbrella review. Eur Respir J 32:230009","journal-title":"Eur Respir J"},{"key":"3946_CR61","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.envres.2016.07.036","volume":"151","author":"C Huang","year":"2016","unstructured":"Huang C, Wang X, Liu W, Cai J, Shen L, Zou Z, Lu R, Chang J, Wei X, Sun C, Zhao Z, Sun Y, Sundell J (2016) Household indoor air quality and its association with childhood asthma in shanghai, China: on-site inspected methods and preliminary results. Environ Res 151:154\u2013167","journal-title":"Environ Res"},{"key":"3946_CR62","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1111\/j.1600-0668.2010.00673.x","volume":"20","author":"M Hulin","year":"2010","unstructured":"Hulin M, Caillard D, Annesi-Maessano I (2010) Indoor air pollution and childhood asthma: variation between urban and rural areas. Indoor Air 20:502\u2013514","journal-title":"Indoor Air"},{"key":"3946_CR63","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1080\/10962247.2016.1231145","volume":"67","author":"SH Hwang","year":"2017","unstructured":"Hwang SH, Lee GB, Kim IS, Park WM (2017) Formaldehyde and CO2 concentrations and their relationship with environmental factors in daycare centers. J Air Waste Manag Assoc 67:306\u2013312","journal-title":"J Air Waste Manag Assoc"},{"key":"3946_CR64","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.scitotenv.2018.08.391","volume":"650","author":"J Idavain","year":"2019","unstructured":"Idavain J, Juige K, Rebane T, Lang A, Orru H (2019) Respiratory symptoms, astma and levels of fractional exhaled nitric oxide in schoolchrildren in the industrial areas of estonia. Sci Total Environ 650:65\u201372","journal-title":"Sci Total Environ"},{"key":"3946_CR65","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.cpr.2009.02.006","volume":"29","author":"T Janssens","year":"2009","unstructured":"Janssens T, Verleden G, De Peuter S, Van Diest I, Van den Bergh O (2009) Inaccurate perception for asthma symptoms: a cognitive-affective framwork and implications for asthma treatment. Clin Psychol Rev 29:317\u2013327","journal-title":"Clin Psychol Rev"},{"key":"3946_CR66","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.jpsychores.2011.04.005","volume":"71","author":"T Janssens","year":"2011","unstructured":"Janssens T, Verleden G, De Peuter S, Petersen S, Van den Bergh O (2011) The influence of fear symptoms and perceived control on asthma symptom perception. J Psychosom Res 71:154\u2013159","journal-title":"J Psychosom Res"},{"key":"3946_CR67","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1080\/08958378.2017.1299260","volume":"29","author":"M Johansson","year":"2017","unstructured":"Johansson M, Gustafsson \u00c5, Johanson G, \u00d6berg M (2017) Comparison of airway response in na\u00efve and ovalbumin-sensitized mice during short-term inhalation exposure to chlorine. Inhal Toxicol 29:82\u201391","journal-title":"Inhal Toxicol"},{"key":"3946_CR68","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1289\/ehp.0901143","volume":"118","author":"McGwin JrG","year":"2010","unstructured":"JrG McGwin, Lienert J, Kennedy JI Jr (2010) Formaldehyde exposure and asthma in children: a systematic review. Environ Health Perspect 118:313\u2013317","journal-title":"Environ Health Perspect"},{"key":"3946_CR69","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1080\/10408444.2018.1518404","volume":"48","author":"C JrLA","year":"2018","unstructured":"JrLA C (2018) Modernizing the bradford hill criteria for assessing causal relationships in observational data. Crit Rev Toxicol 48:682\u2013712","journal-title":"Crit Rev Toxicol"},{"key":"3946_CR70","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1289\/ehp.1307922","volume":"123","author":"W Kanchongkittiphon","year":"2015","unstructured":"Kanchongkittiphon W, Mendell MJ, Gaffin JM, Wang G, Phipatanakul W (2015) Indoor environmental exposures and exacerbation of asthma: an update to the 2000 review by the Institute of Medicine. Environ Health Perspect 123:6\u201320","journal-title":"Environ Health Perspect"},{"key":"3946_CR71","first-page":"468","volume":"46","author":"K Kilburn","year":"1989","unstructured":"Kilburn K, Warshaw R, Thornton JC (1989) Pulmonary function in histology technicians compared with women from michigan: effects of chronic low dose formaldehyde on a national sample of women. Br J Ind Med 46:468\u2013472","journal-title":"Br J Ind Med"},{"key":"3946_CR72","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1080\/00039899909602245","volume":"54","author":"H Kim","year":"1999","unstructured":"Kim H, Kim Y-D, Cho S-H (1999) Formaldehyde exposure levels and serum antibodies to formaldehyde-human serum albumin of korean medical students. Arch Environ Health 54:115\u2013118","journal-title":"Arch Environ Health"},{"key":"3946_CR73","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1111\/j.1600-0668.2006.00466.x","volume":"17","author":"JL Kim","year":"2007","unstructured":"Kim JL, Elfman L, Mi Y, Wieslander G, Smedje G, Norb\u00e4ck D (2007) Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools - associations with asthma and respiratory symptoms in pupils. Indoor Air 17:153\u2013163","journal-title":"Indoor Air"},{"key":"3946_CR74","doi-asserted-by":"publisher","first-page":"166","DOI":"10.3346\/jkms.2011.26.2.166","volume":"26","author":"JL Kim","year":"2011","unstructured":"Kim JL, Elfman L, Wieslander G, Ferm M, Tor\u00e9n K, Norb\u00e4ck D (2011) Respiratory health among korean pupils in relation to home, school and outdoor environment. J Korean Med Sci 26:166\u2013173","journal-title":"J Korean Med Sci"},{"key":"3946_CR75","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1007\/s00204-023-03642-w","volume":"98","author":"S Kleinbeck","year":"2024","unstructured":"Kleinbeck S, Wolkoff P (2024) Exposure limits for indoor gaseous substances concerning the general population: sensory irritation in the eyes and airways. Arch Toxicol 98:617\u2013662","journal-title":"Arch Toxicol"},{"key":"3946_CR76","doi-asserted-by":"publisher","first-page":"1687","DOI":"10.1007\/s00204-020-02703-8","volume":"94","author":"S Kleinbeck","year":"2020","unstructured":"Kleinbeck S, Sch\u00e4per M, Pacharra M, Lehmann ML, Golka K, Blaszkewicz M, Br\u00fcning T, van Thriel C (2020) A short-term inhalation study to assess the reversibility of sensory irritation in human volunteers. Arch Toxicol 94:1687\u20131701","journal-title":"Arch Toxicol"},{"key":"3946_CR77","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.fct.2012.11.008","volume":"52","author":"AJ Kleinnijenhuis","year":"2013","unstructured":"Kleinnijenhuis AJ, Staal YDE, Engel R, Woutersen RA (2013) The determination of exogenous formaldehyde in blood of rats during and after inhalation exposure. Food Chem Toxicol 52:105\u2013112","journal-title":"Food Chem Toxicol"},{"key":"3946_CR78","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1002\/(SICI)1097-0274(199803)33:3<274::AID-AJIM9>3.0.CO;2-W","volume":"33","author":"A Krakowiak","year":"1998","unstructured":"Krakowiak A, Gorski P, Pazdrak K, Ruta U (1998) Airway response to formaldehyde inhalation in asthmatic subjects with suspected respiratory formaldehyde sensitization. Am J Ind Med 33:274\u2013281","journal-title":"Am J Ind Med"},{"key":"3946_CR79","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1080\/00039890109604049","volume":"56","author":"D Kriebel","year":"2001","unstructured":"Kriebel D, Myers D, Cheng M, Woskie S, Cocanour B (2001) Short-term effects of formaldehyde on peak expiratory flow and irritant symptoms. Arch Environ Health 56:11\u201318","journal-title":"Arch Environ Health"},{"key":"3946_CR80","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/S0013-9351(05)80247-6","volume":"52","author":"M Krzyzanowski","year":"1990","unstructured":"Krzyzanowski M, Quackenboss JJ, Lebowitz MD (1990) Chronic respiratory effects of indoor formaldehyde exposure. Environ Res 52:117\u2013125","journal-title":"Environ Res"},{"key":"3946_CR81","doi-asserted-by":"publisher","first-page":"S18","DOI":"10.1080\/15459624.2015.1060328","volume":"12","author":"ED Kuempel","year":"2015","unstructured":"Kuempel ED, Sweeney D, Morris JB, Jarabek AM (2015) Advances inhalation dosimetry models and methods for occupational risk assessment and exposure limit derivation. J Occup Environ Hyg 12:S18\u2013S40","journal-title":"J Occup Environ Hyg"},{"key":"3946_CR82","first-page":"323","volume":"5","author":"TJ Kulle","year":"1993","unstructured":"Kulle TJ (1993) Acute odor and irritation response in healthy nonsmokers with formaldehyde exposure. Toxicol Ind Health 5:323\u2013332","journal-title":"Toxicol Ind Health"},{"key":"3946_CR83","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1080\/08940630.1987.10466285","volume":"37","author":"TJ Kulle","year":"1987","unstructured":"Kulle TJ, Sauder LR, Hebel JR, Green DJ, Chatman MD (1987) Formaldehyde dose-response in healthy nonsmokers. JAPCA 37:919\u2013924","journal-title":"JAPCA"},{"key":"3946_CR84","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1289\/ehp.9848","volume":"115","author":"Y Kuwabara","year":"2007","unstructured":"Kuwabara Y, Alexeeff GV, Broadwin R, Salmon AG (2007) Evaluation and application of the rd50 for determining acceptable exposure levels of airborne sensory irritants for the general public. Environ Health Perspec 115:1609\u20131616","journal-title":"Environ Health Perspec"},{"key":"3946_CR85","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1111\/ina.12181","volume":"25","author":"P Lajoie","year":"2015","unstructured":"Lajoie P, Aubin D, Gingras V, Daigneault P, Ducharme F, Gauvin D, Fugler D, Leclerc J-M, Won D, Courteau M, Yang W, Schleibinger H (2015) The IVAIRE project - a randomized controlled study of the impact of ventilation on indoor air quality and the respiratory symptoms of asthmatic children in single family homes. Indoor Air 25:582\u2013597","journal-title":"Indoor Air"},{"key":"3946_CR86","doi-asserted-by":"crossref","unstructured":"Lam J, Koustas E, Sutton P, Padula A M, Cabana M D, Vesterinen H, Griffiths C, Dickie M, Daniels N, Whitaker E and Woodruff T J (2021) Exposure to Formaldehyde and Asthma Outcomes: A Systematic Review, Meta-Analysis, and Economic Assessment. PLos ONE e0248258.","DOI":"10.1371\/journal.pone.0248258"},{"key":"3946_CR87","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.yrtph.2007.08.012","volume":"50","author":"I Lang","year":"2008","unstructured":"Lang I, Bruckner T, Triebig G (2008) Formaldehyde and chemosensory irritation in humans: a controlled human exposure study. Reg Toxicol Pharmacol 50:23\u201336","journal-title":"Reg Toxicol Pharmacol"},{"key":"3946_CR88","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.taap.2013.02.006","volume":"268","author":"ST Larsen","year":"2013","unstructured":"Larsen ST, Wolkoff P, Hammer M, Kofoed-S\u00f8rensen V, Clausen PA, Nielsen GD (2013) Acute airway effects of airborne formaldehyde in sensitized and non-sensitized mice housed in dry or humid environment. Toxicol Appl Pharmacol 268:294\u2013299","journal-title":"Toxicol Appl Pharmacol"},{"key":"3946_CR89","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1080\/09603123.2010.533368","volume":"21","author":"M Larsson","year":"2011","unstructured":"Larsson M, H\u00e4gerhed-Engman L, Moniruzzaman S, Janson S, Sundell J, Bornehag C-G (2011) Can we trust cross-sectional studies when studying the risk of moisture-related problems indoor for asthma in children? Int J Environ Health Res 21:237\u2013247","journal-title":"Int J Environ Health Res"},{"key":"3946_CR90","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1007\/s00204-019-02393-x","volume":"93","author":"J Leng","year":"2019","unstructured":"Leng J, Liu C-W, Hartwell HJ, Yu R, Lai Y, Bodnar WM, Lu K, Swenberg JA (2019) Evaluation of inhaled low-dose formaldehyde-induced DNA adducts and DNA-protein cross-links by liquid chromatography-tandem mass spectrometry. Arch Toxicol 93:763\u2013773","journal-title":"Arch Toxicol"},{"key":"3946_CR91","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0179231","volume":"12","author":"L Li","year":"2017","unstructured":"Li L, Hua L, He Y, Bao Y (2017) Differential effects of formaldehyde exposure on airway inflammation and bronchial hyperresponsiveness in BALB\/c and C57BL\/6 mice. PLoS ONE 12:e0179231","journal-title":"PLoS ONE"},{"key":"3946_CR92","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.aanat.2015.08.003","volume":"202","author":"LF Lima","year":"2015","unstructured":"Lima LF, Murta GL, Bandeira ACB, Nardeli CR, Lima WG, Bezerra FS (2015) Short-term exposure to formaldehyde promotes oxidative damage and inflammation in the trachea and diaphragm muscle of adult rats. Anal Anat 202:45\u201351","journal-title":"Anal Anat"},{"key":"3946_CR93","doi-asserted-by":"publisher","first-page":"2202","DOI":"10.1016\/j.atmosenv.2005.12.005","volume":"40","author":"W Liu","year":"2006","unstructured":"Liu W, Zhang Z, Zhang L, Turpin BJ, Weisel CP, Morandi MT, Stock TH, Colome S, Korn LR (2006) Estimating contributions of indoor and outdoor sources to indoor carbonyl concentrations in three urban areas of the United States. Atmos Environ 40:2202\u20132214","journal-title":"Atmos Environ"},{"key":"3946_CR94","first-page":"305","volume":"8","author":"D Liu","year":"2011","unstructured":"Liu D, Zheng Y, Li B, Yao H, Li R, Zhang Y, Yang X (2011) Adjuvant effects of gaseous formaldehyde on the hyperresponsivenss and inflammation in a mouse asthma model immunized by ovalbumin. J Immunol 8:305\u2013314","journal-title":"J Immunol"},{"key":"3946_CR95","doi-asserted-by":"publisher","DOI":"10.1016\/j.buildenv.2023.110080","volume":"233","author":"N Liu","year":"2023","unstructured":"Liu N, Fang L, Liu W, Kan H, Zhao Z, Deng F, Huang C, Zhao B, Zeng X, Sun Y, Qian H, Mo J, Sun C, Guo J, Zheng X, Bu Z, Weschler LB, Zhang Y (2023) Health effects of exposure to indoor formaldehyde in civil buildings: a systematic review and meta-analysis on the literature in the past 40 years. Build Environ 233:110080","journal-title":"Build Environ"},{"key":"3946_CR96","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1021\/acs.chemrestox.1c00212","volume":"35","author":"K Lu","year":"2022","unstructured":"Lu K, Hsiao Y-C, Liu C-W, Schoeny R, Gentry R, Starr TB (2022a) A review of stable isotope labeling and mass spectrometry methods to distinguish exogeneous from endegeneous dna adducts and improve dose-respeonse assessments. Chem Res Toxicol 35:7\u201329","journal-title":"Chem Res Toxicol"},{"key":"3946_CR97","doi-asserted-by":"publisher","first-page":"120234","DOI":"10.1016\/j.envpol.2022.120234","volume":"215","author":"X Lu","year":"2022","unstructured":"Lu X, Gong C, Lv K, Zheng L, Li B, Zhao Y, Lu H, Wei T, Huang J, Li R (2022b) Impacts of combined exposure to formaldehyde and PM2.5 at ambient concentrations on airway inflammation in mice. Environ Pollut 215:120234","journal-title":"Environ Pollut"},{"key":"3946_CR98","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1080\/19338244.2014.965246","volume":"71","author":"D Lukcso","year":"2016","unstructured":"Lukcso D, Guidotti TL, Franklin DE, Burt A (2016) Indoor environmental and air quality characteristics, building-related health symptoms, and worker productivity in a federal government building complex. Arch Env Occup Health 71:85\u2013101","journal-title":"Arch Env Occup Health"},{"key":"3946_CR99","doi-asserted-by":"publisher","first-page":"20539","DOI":"10.1007\/s11356-016-7269-x","volume":"23","author":"J Maduereira","year":"2016","unstructured":"Maduereira J, Pici\u00eancia I, Cavaleiro-Rufo J, Fernandes EO (2016) Indoor pollutant exposure among children with or without asthma in porto, portugal, during the cold season. Environ Sci Pollut Res 23:20539\u201320552","journal-title":"Environ Sci Pollut Res"},{"key":"3946_CR100","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.scitotenv.2016.10.238","volume":"579","author":"C Mandin","year":"2017","unstructured":"Mandin C, Trantallidi M, Cattaneo A, Canha N, Mihucz VG, Szigeti T, Mabilia R, Perreca E, Spinazz\u00e8 A, Fossati S, de Kluizenaar Y, Cornelissen E, Sakellaris I, Saraga D, H\u00e4nninen O, de Oliveira APL, Ventura G, Wolkoff P, Carrer P, Bartzis J (2017) Assessment of indoor air quality in office buildings across Europe - The OFFICAIR study. Sci Total Environ 579:169\u2013178","journal-title":"Sci Total Environ"},{"key":"3946_CR101","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.annepidem.2007.07.095","volume":"18","author":"I Matsunaga","year":"2008","unstructured":"Matsunaga I, Miyake Y, Yoshida T, Miyamoto S, Ohya Y, Sasaki S, Tanaka K, Oda H, Ishiko O, Hiroto Y, the Osaka Maternal and child health study group, (2008) Ambient formaldehyde levels and allergic disorders among japanese pregnant women: baseline data from the osaka maternal and child health study. Ann Epidemiol 18:78\u201384","journal-title":"Ann Epidemiol"},{"key":"3946_CR102","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1111\/j.1600-0668.2006.00439.x","volume":"16","author":"Y-H Mi","year":"2006","unstructured":"Mi Y-H, Norb\u00e4ck D, Tao J, Mi Y-L, Ferm M (2006) Current asthma and respiratory symptoms among pupils in Shanghai, China: influence of building ventilation, nitrogen dioxide, ozone, and formaldehyde in classrooms. Indoor Air 16:454\u2013464","journal-title":"Indoor Air"},{"key":"3946_CR103","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1080\/08958378.2018.1430191","volume":"29","author":"FJ Miller","year":"2017","unstructured":"Miller FJ, Conolly RB, Kimbell JS (2017) An Updated analysis of respiratory tract cells at risk for formaldehyde carcinogenesis. Inhal Toxicol 29:586\u2013597","journal-title":"Inhal Toxicol"},{"key":"3946_CR104","doi-asserted-by":"publisher","first-page":"2.1","DOI":"10.1146\/annurev-virology-012420-022445","volume":"7","author":"M Moriyama","year":"2020","unstructured":"Moriyama M, Hugentobler WJ, Iwasaki A (2020) Seasonality of respiratory viral infections. Annu Rev Virol 7:2.1-2.19","journal-title":"Annu Rev Virol"},{"key":"3946_CR105","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s00420-012-0745-9","volume":"86","author":"JU Mueller","year":"2013","unstructured":"Mueller JU, Bruckner T, Triebig G (2013) Exposure study to examine chemosensory effects of formaldehyde on hyposensitive and hypersensitive males. Int Arch Occup Environ Health 86:107\u2013117","journal-title":"Int Arch Occup Environ Health"},{"key":"3946_CR106","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1111\/j.1600-0668.2012.00800.x","volume":"23","author":"MW Murphy","year":"2013","unstructured":"Murphy MW, Lando JF, Kierzak SM, Sutter ME, Noonan GP, Brunkard JM, McGeehin MA (2013) Formaldehyde levels in FEMA-supplied travel trailers, park models, and mobile homes in louisiana and missisipi. Indoor Air 23:134\u2013141","journal-title":"Indoor Air"},{"key":"3946_CR107","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1016\/j.yrtph.2017.09.015","volume":"90","author":"GD Nielsen","year":"2017","unstructured":"Nielsen GD, Wolkoff P (2017) Evaluation of airborne sensory irritants for setting exposure limits or guidelines: a systematic approach. Regul Toxicol Pharmacol 90:308\u2013317","journal-title":"Regul Toxicol Pharmacol"},{"key":"3946_CR108","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1191\/096032799678840246","volume":"18","author":"GD Nielsen","year":"1999","unstructured":"Nielsen GD, Hougaard KS, Larsen ST, Wolkoff P, Clausen PA, Wilkins CK, Alarie Y (1999) Acute airway effects of formaldehyde and ozone in BALB\/c Mice. Hum Exp Toxicol 18:400\u2013409","journal-title":"Hum Exp Toxicol"},{"key":"3946_CR109","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1007\/s00204-012-0975-3","volume":"87","author":"GD Nielsen","year":"2013","unstructured":"Nielsen GD, Larsen ST, Wolkoff P (2013) Recent trend in risk assessment of formaldehyde exposures from indoor air. Arch Toxicol 87:73\u201398","journal-title":"Arch Toxicol"},{"key":"3946_CR111","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1136\/oem.52.6.388","volume":"52","author":"D Norb\u00e4ck","year":"1995","unstructured":"Norb\u00e4ck D, Bj\u00f6rnsson E, Janson C, Widstr\u00f6m J, Boman G (1995) Asthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings. Occup Environ Med 52:388\u2013395","journal-title":"Occup Environ Med"},{"key":"3946_CR112","doi-asserted-by":"publisher","first-page":"13331","DOI":"10.1021\/es504106j","volume":"48","author":"AW N\u00f8rgaard","year":"2014","unstructured":"N\u00f8rgaard AW, Kofoed-S\u00f8rensen V, Mandin C, Ventura G, Mabilia R, Perreca E, Cattaneo A, Spinazze A, Mihucz VG, Szigeti T, de Kluizenaar Y, Cornelissen HJM, Trantallidi M, Carrer P, Sakellaris I, Bartzis J, Wolkoff P (2014) Ozone-initiated terpene reaction products in five european offices: replacement of a floor cleaning agent. Environ Sci Technol 48:13331\u201313339","journal-title":"Environ Sci Technol"},{"key":"3946_CR113","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1183\/09059180.00000714","volume":"24","author":"UB Nurmatov","year":"2015","unstructured":"Nurmatov UB, Tagiyeva N, Semple S, Devereux G, Sheikh A (2015) Volatile organic compounds and risk of asthma and allergy: a systematic review. Eur Respir J 24:92\u2013101","journal-title":"Eur Respir J"},{"key":"3946_CR114","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1093\/toxsci\/64.1.122","volume":"64","author":"JH Overton","year":"2001","unstructured":"Overton JH, Kimbell JS, Miller FJ (2001) Dosimetry modeling of inhaled formaldehyde: the human respiratory tract. Toxicol Sci 64:122\u2013134","journal-title":"Toxicol Sci"},{"key":"3946_CR115","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.etp.2008.05.008","volume":"61","author":"F Pariselli","year":"2009","unstructured":"Pariselli F, Sacco MG, Rembges D (2009) An optimized method for in Vitro exposure of human derived lung cells to volatile chemicals. Exp Toxicol Pathol 61:33\u201339","journal-title":"Exp Toxicol Pathol"},{"key":"3946_CR116","doi-asserted-by":"publisher","first-page":"3993","DOI":"10.3390\/ijerph120403993","volume":"12","author":"E Patelarou","year":"2014","unstructured":"Patelarou E, Tzanakis N, Kelly FJ (2014) Exposure to indoor pollutants and wheeze and asthma development during early childhood. Int J Environ Res Public Health 12:3993\u20134017","journal-title":"Int J Environ Res Public Health"},{"key":"3946_CR117","doi-asserted-by":"publisher","DOI":"10.1016\/j.tox.2021.152929","volume":"462","author":"J Pauluhn","year":"2021","unstructured":"Pauluhn J, Whalan JE (2021) Human risk assessment of inhaled irritants: role of sensory stimulation from spatially separated nociceptors. Toxicology 462:152929","journal-title":"Toxicology"},{"key":"3946_CR118","doi-asserted-by":"crossref","unstructured":"Pauluhn J (2014) Animal models for respiratory hypersensitivity, in Encyclopedia of Immunotoxicology (Vohr HW ed) Springer-Verlag, Berlin, Heidelberg, page 1\u20139.","DOI":"10.1007\/978-3-642-27786-3_68-3"},{"key":"3946_CR119","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1080\/1047322X.1997.10389531","volume":"12","author":"DJ Paustenbach","year":"1997","unstructured":"Paustenbach DJ (1997) Methods for setting limits for acute and chronic toxic ambient air contaminants. Appl Occup Environ Hyg 12:418\u2013428","journal-title":"Appl Occup Environ Hyg"},{"key":"3946_CR120","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1080\/009841097160465","volume":"50","author":"DJ Paustenbach","year":"1997","unstructured":"Paustenbach DJ, Alarie Y, Kulle T, Schachter N, Smith R, Swenberg J, Witschi H, Horowitz SB (1997) A Recommended occupational exposure limit for formaldehyde based on irritation. J Toxicol Environ Health 50:217\u2013263","journal-title":"J Toxicol Environ Health"},{"key":"3946_CR121","doi-asserted-by":"publisher","DOI":"10.1016\/j.yrtph.2024.105568","volume":"147","author":"MA Pemberton","year":"2024","unstructured":"Pemberton MA, Arts JHE, Kimber I (2024) Identification of true chemical respiratory allergens: current status, limitations and recommendations. Regul Toxicol Pharmacol 147:105568","journal-title":"Regul Toxicol Pharmacol"},{"key":"3946_CR122","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.toxlet.2012.03.799","volume":"211","author":"C Persoz","year":"2012","unstructured":"Persoz C, Achard S, Momas I, Seta N (2012) Inflammatory response modulation of airway epithelial cells exposed to formaldehyde. Toxicol Lett 211:159\u2013163","journal-title":"Toxicol Lett"},{"key":"3946_CR123","doi-asserted-by":"publisher","DOI":"10.3389\/ftox.2022.916370","volume":"4","author":"J Ponder","year":"2022","unstructured":"Ponder J, Rajagopal R, Singal M, Baker N, Patlewicz G, Roggren E, Cochrane S, Sullivan K (2022) \u201cIn Litero\u201d screening: retrospective evaluation of clinical evidence to establish a reference list of human chemicl respiratory sensitizers. Front Toxicol 4:916370","journal-title":"Front Toxicol"},{"key":"3946_CR124","doi-asserted-by":"publisher","first-page":"1200","DOI":"10.3109\/08958370902806159","volume":"21","author":"Y Qiao","year":"2009","unstructured":"Qiao Y, Li B, Yang G, Yao H, Yang J, Liu D, Yan Y, Sigsgaard T, Yang X (2009) Irritant and adjuvant effects of gaseous formaldehyde on the ovalbumin-induced hyperresponsiveness and inflammation in a rat model. Inhal Toxicol 21:1200\u20131207","journal-title":"Inhal Toxicol"},{"key":"3946_CR125","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1111\/j.1600-0668.2009.00635.x","volume":"20","author":"O Raaschou-Nielsen","year":"2010","unstructured":"Raaschou-Nielsen O, Northman Hermansen M, Loland L, Buchvald F, Bressen Pipper C, S\u00f8rensen M, Loft S, Bisgaard H (2010) Long.-Term exposure to indoor air pollution and wheezing symptoms in infants. Indoor Air 20:159\u2013167","journal-title":"Indoor Air"},{"key":"3946_CR126","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.aca.2010.04.049","volume":"669","author":"U Riess","year":"2010","unstructured":"Riess U, Tegtbur U, Fauck C, Fuhrmann F, Markewitz D, Salthammer T (2010) Experimental setup and analytical methods for the non-invasive determination of volatile organic compounds, formaldehyde and NOx in exhaled human breath. Anal Chim Acta 669:53\u201362","journal-title":"Anal Chim Acta"},{"key":"3946_CR127","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1183\/09031936.02.00245002","volume":"20","author":"K Rumchev","year":"2002","unstructured":"Rumchev K, Spickett J, Bulsara M, Philips MR, Stick SM (2002) Domestic exposure of formaldehyde significantly increases the risk of asthma in young children. Eur Respir J 20:403\u2013406","journal-title":"Eur Respir J"},{"key":"3946_CR128","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1136\/thx.2003.013680","volume":"59","author":"K Rumchev","year":"2004","unstructured":"Rumchev K, Spickett J, Bulsara M, Stick S (2004) Association of domestic exposure to volatile organic compounds with asthma in young children. Thorax 59:746\u2013751","journal-title":"Thorax"},{"key":"3946_CR129","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1080\/10408444.2021.2024142","volume":"51","author":"N Sadekar","year":"2021","unstructured":"Sadekar N, Boisleve F, Dekant W, Fryer AD, Gerberick GF, Griem P, Hickey C, Krutz NL, Lemke O, Mignatelli C, Panettieri R, Pinkerton KE, Renskers KJ, Sterchele P, Switalla S, Wolter M, Api AM (2021) Identifying a reference list of respiratory sensitizers for the evaluation of novel approaches to study respiratory sensitization. Crit Rev Toxicol 51:792\u2013804","journal-title":"Crit Rev Toxicol"},{"key":"3946_CR130","doi-asserted-by":"publisher","first-page":"3320","DOI":"10.1002\/anie.201205984","volume":"52","author":"T Salthammer","year":"2013","unstructured":"Salthammer T (2013) Formaldehyde in the ambient atmosphere: from an indoor pollutant to an outdoor pollutant. Angew Chem Int Ed 52:3320\u20133327","journal-title":"Angew Chem Int Ed"},{"key":"3946_CR131","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.buildenv.2018.12.042","volume":"150","author":"T Salthammer","year":"2019","unstructured":"Salthammer T (2019) Formaldehyde sources, formaldehyde concentrations and air exchange rates in European housing. Build Environ 150:219\u2013232","journal-title":"Build Environ"},{"key":"3946_CR132","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1097\/00043764-198606000-00008","volume":"28","author":"LR Sauder","year":"1986","unstructured":"Sauder LR, Chatman MD, Green DJ, Kulle TJ (1986) Acute pulmonary response to formaldehyde exposure in healthy nonsmokers. J Occup Med 28:420\u2013424","journal-title":"J Occup Med"},{"key":"3946_CR133","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1177\/074823378700300408","volume":"3","author":"LR Sauder","year":"1987","unstructured":"Sauder LR, Green DJ, Chatman MD, Kulle TJ (1987) Acute pulmonary response of asthmatics to 3.0 ppm formaldehyde. Toxicol Ind Health 3:569\u2013578","journal-title":"Toxicol Ind Health"},{"key":"3946_CR134","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/S0013-9351(87)80227-X","volume":"44","author":"EN Schachter","year":"1987","unstructured":"Schachter EN, Witek J Jr, Brody DJ, Tosun T, Beck GJ, Leaderer BP (1987) A study of respiratory effects from exposure to 2.0 ppm formaldehyde in occupationally exposed workers. Environl Res 44:188\u2013205","journal-title":"Environl Res"},{"key":"3946_CR135","doi-asserted-by":"publisher","first-page":"1729","DOI":"10.1039\/D1EM00221J","volume":"23","author":"A Schieweck","year":"2021","unstructured":"Schieweck A, Uhde E, Salthammer T (2021) Determination of acrolein in ambient air and in the atmosphere of enviornmental test chambers. Environ Sci Process Impacts 23:1729\u20131746","journal-title":"Environ Sci Process Impacts"},{"key":"3946_CR136","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1111\/1539-6924.00328","volume":"23","author":"PM Schlosser","year":"2003","unstructured":"Schlosser PM, Lilly PD, Conolly RB, Janszen D, Kimbell JS (2003) Becnmark dose risk assessment formaldehyde using airflow modeling and a single-compartment DNA-protein cross-link dosimetry to model human equivalent dose. Risk Anal 23:473\u2013487","journal-title":"Risk Anal"},{"key":"3946_CR137","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1093\/toxsci\/kft333","volume":"138","author":"JD Schroeter","year":"2014","unstructured":"Schroeter JD, Campbell L, Kimbell JS, Conolly RB, Clewell HJ III, Andersen ME (2014) Effects of endogenous formaldehyde in nasal tissues on inhaled formaldehyde dosimetry predictions in the rat, monkey, and human nasal passage. Toxicol Sci 138:412\u2013424","journal-title":"Toxicol Sci"},{"key":"3946_CR138","unstructured":"SCOEL. Recommendation from the Scientific Committee on Occupational Exposure Limits for Formaldehyde. SCOEL\/REC\/125, 1\u201321. 2016. European Commission Ref Type: Report."},{"key":"3946_CR139","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/0013-9351(84)90120-8","volume":"35","author":"D Sheppard","year":"1984","unstructured":"Sheppard D, Eschenbacher WL, Epstein J (1984) Lack of bronchomotor response to up to 3 ppm formaldehyde in subjects with asthma. Environ Res 35:133\u2013139","journal-title":"Environ Res"},{"key":"3946_CR140","first-page":"1059","volume":"5","author":"G Smedje","year":"2001","unstructured":"Smedje G, Norb\u00e4ck D (2001) Incidence of asthma diagnosis and self-reported allergy in relation to the school environment - a four year follow-up in school children. Int J Tuberc Lung Dis 5:1059\u20131066","journal-title":"Int J Tuberc Lung Dis"},{"key":"3946_CR141","doi-asserted-by":"publisher","first-page":"1270","DOI":"10.1111\/j.1365-2222.1997.tb01171.x","volume":"27","author":"G Smedje","year":"1997","unstructured":"Smedje G, Norb\u00e4ck D, Edling C (1997) Asthma among secondary schoolchildren in relation to the school environment. Clin Exp Allergy 27:1270\u20131278","journal-title":"Clin Exp Allergy"},{"key":"3946_CR142","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1586\/1744666X.2014.972943","volume":"10","author":"N Tagiyeva","year":"2014","unstructured":"Tagiyeva N, Sheikh A (2014) Domestic exposure to volatile organic compounds in relation to asthma and allergy in children and adults. Expert Rev Clin Immunol 10:1611\u20131639","journal-title":"Expert Rev Clin Immunol"},{"key":"3946_CR143","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1513\/AnnalsATS.201706-508ST","volume":"14","author":"S Tarlo","year":"2017","unstructured":"Tarlo S, Malo JL, de Blay F, Le Moual N, Henneberger P, Heederik D, Raulf M, Carlsten C, Cartier A (2017) An official american thoraic society workshop report: presentations and discussion of the sixth jack pepys workshop on asthma in the workplase. Ann Am Thorac Soc 14:1361\u20131372","journal-title":"Ann Am Thorac Soc"},{"key":"3946_CR144","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1016\/j.jaci.2005.12.1311","volume":"117","author":"G Tavernier","year":"2006","unstructured":"Tavernier G, Fletcher G, Gee I, Watson A, Blacklock G, Francis H, Fletcher A, Frank T, Frank P, Pickering CA, Niven R (2006) IPEADAM study: indoor endotoxin exposure, family status, and some housing characteristics in english children. J Allergy Clin Immun 117:656\u2013662","journal-title":"J Allergy Clin Immun"},{"key":"3946_CR145","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1080\/15287390701598259","volume":"71","author":"CM Thompson","year":"2008","unstructured":"Thompson CM, Grafstr\u00f6m RC (2008) Mechanistic considerations for formaldehyde-induced bronchoconstriction involving S-nitrosoglutathione reductase. J Toxicol Environ Health Part A 71:244\u2013248","journal-title":"J Toxicol Environ Health Part A"},{"key":"3946_CR146","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1002\/ajim.4700150110","volume":"15","author":"G Uba","year":"1989","unstructured":"Uba G, Pachorek D, Bernstein J, Garabrant DH, Balmes JR, Wright WE, Amar RB (1989) Prospective study of respiratory effects of formaldehyde among healthy and asthmatic medical students. Am J Ind Med 15:91\u2013101","journal-title":"Am J Ind Med"},{"key":"3946_CR147","doi-asserted-by":"publisher","first-page":"1551","DOI":"10.1007\/s00204-018-2161-8","volume":"92","author":"S Van Den Broucke","year":"2018","unstructured":"Van Den Broucke S, Pollaris L, Vande Velde G, Verbeken E, Nemery B, Vanoirbeek J, Hoet P (2018) Irritant-induced asthma to hypochlorite in mice due to impairment of the airway barrier. Arch Toxicol 92:1551\u20131561","journal-title":"Arch Toxicol"},{"key":"3946_CR148","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1136\/thorax.58.11.955","volume":"58","author":"AJ Venn","year":"2003","unstructured":"Venn AJ, Cooper M, Antoniak M, Laughlin C, Britton J, Lewis SA (2003) Effects of volatile organic compounds, damp, and other environmental exposures in the home on wheezing illness in children. Thorax 58:955\u2013960","journal-title":"Thorax"},{"key":"3946_CR149","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1034\/j.1398-9995.2000.00307.x","volume":"55","author":"F Wantke","year":"2000","unstructured":"Wantke F, Focke M, Hemmer W, Bracun R, Wolf-Abdolvahab S, G\u00f6tz M, Jarish R, Tschabitscher M, Gann M, Tappler P (2000) Exposure to formaldehyde and phenol during an anatomy dissecting course: sensitizing potency of formaldehyde and phenol in medical students. Allergy 55:84\u201387","journal-title":"Allergy"},{"key":"3946_CR150","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/BF00575156","volume":"40","author":"A Weber-Tschopp","year":"1977","unstructured":"Weber-Tschopp A, Fischer T, Gierer R, Grandjean E (1977) Experimentelle reizwirkungen von akrolein auf den mensch. Int Arch Occup Environ Health 40:117\u2013130","journal-title":"Int Arch Occup Environ Health"},{"key":"3946_CR151","first-page":"230","volume":"42","author":"J Witek Jr","year":"1987","unstructured":"Witek J Jr, Schachter EN, Tosun T, Beck GJ, Leaderer BP (1987) An evaluation of respiratory effects following exposure to 2.0 ppm formaldehyde in asthmatics: lung function, symptoms, and airway reactivity. Arch Environ Health 42:230\u2013237","journal-title":"Arch Environ Health"},{"key":"3946_CR152","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/j.ijheh.2012.08.001","volume":"216","author":"P Wolkoff","year":"2013","unstructured":"Wolkoff P (2013) Indoor air pollutants in office environments: assessment of comfort, health, and performance. Int J Hyg Environ Health 216:371\u2013394","journal-title":"Int J Hyg Environ Health"},{"key":"3946_CR153","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijheh.2023.114313","volume":"256","author":"P Wolkoff","year":"2024","unstructured":"Wolkoff P (2024) Indoor Air humidity revisited: impact on acute symptoms, work productivity, and risk of influenza and COVID-19. Int J Hyg Environ Health 256:114313","journal-title":"Int J Hyg Environ Health"},{"key":"3946_CR154","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1016\/j.envint.2010.05.012","volume":"36","author":"P Wolkoff","year":"2010","unstructured":"Wolkoff P, Nielsen GD (2010) Non-cancer effects of formaldehyde and relevance for setting an indoor air guideline. Environ Int 36:788\u2013799","journal-title":"Environ Int"},{"key":"3946_CR155","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.toxlet.2011.12.008","volume":"209","author":"P Wolkoff","year":"2012","unstructured":"Wolkoff P, Clausen PA, Larsen ST, Hammer M, Nielsen GD (2012) airway effects of repeated exposures to ozone-initiated limonene oxidation products as model of indoor air mixtures. Toxicol Lett 209:166\u2013172","journal-title":"Toxicol Lett"},{"key":"3946_CR156","unstructured":"World Health Organization (2010) Selected Pollutants. WHO Indoor Air Quality Guidelines. WHO Regional Office for Europe, Copenhagen."},{"key":"3946_CR157","doi-asserted-by":"publisher","first-page":"1066","DOI":"10.1136\/thx.53.12.1066","volume":"53","author":"RJ Wright","year":"1998","unstructured":"Wright RJ, Rodriguez M, Cohen S (1998) Review of psychosocial stress and asthma: an integrated biopsychosocial approach. Thorax 53:1066\u20131074","journal-title":"Thorax"},{"key":"3946_CR158","doi-asserted-by":"publisher","DOI":"10.1016\/j.etap.2020.103469","volume":"80","author":"Y Wu","year":"2020","unstructured":"Wu Y, Duan J, Li B, Liu H, Chen M (2020) Exposure to formaldehyde at low temperature aggravates allergic asthma involved in transient receptor potential ion channel. Environ Toxicol Pharmacol 80:103469","journal-title":"Environ Toxicol Pharmacol"},{"key":"3946_CR159","doi-asserted-by":"publisher","DOI":"10.1016\/j.ecoenv.2020.110615","volume":"197","author":"Y Yang","year":"2020","unstructured":"Yang Y, Luo H, Liu R, Li G, Yu Y, An T (2020) The exposure risk of typical VOCs to the human beings via inhalation based on the respiratory deposition rates by proton transfer reaction-time of flight-mass spectrometer. Ecotoxicol Environ Safety 197:110615","journal-title":"Ecotoxicol Environ Safety"},{"key":"3946_CR160","first-page":"8358","volume":"8","author":"Y Yao","year":"2015","unstructured":"Yao Y, Liang W, Zhu L, Duan Y, Jin Y, He L (2015) Relationship between the concentration of formaldehyde in the air and asthma in childdren: a meta-analysis. Int J Clin Exp Med 8:8358\u20138362","journal-title":"Int J Clin Exp Med"},{"key":"3946_CR161","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1164\/rccm.201810-1980LE","volume":"200","author":"D Yon","year":"2019","unstructured":"Yon D, Hwang S, Lee SW, Jee HM, Kim JH, Han MY (2019) Indoor exposure and sensitization to formaldehyde among inner-city children with increased risk for asthma and rhinitis. Am J Respir Crit Care Med 200:392","journal-title":"Am J Respir Crit Care Med"},{"key":"3946_CR162","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1111\/ina.12657","volume":"30","author":"L Yu","year":"2020","unstructured":"Yu L, Wang B, Cheng M, Gan S, Fan L, Wang D, Chen W (2020) Association between indoor formaldehyde exposure and asthma: a systematic review and meta-analysis of observational studies. Indoor Air 30:682\u2013690","journal-title":"Indoor Air"},{"key":"3946_CR163","doi-asserted-by":"publisher","first-page":"102212","DOI":"10.1007\/s11356-023-29631-1","volume":"30","author":"B Zhang","year":"2023","unstructured":"Zhang B, Xia Z, Jiang X, Yuan Y, Yin C, Chen T (2023) Indoor environment in relation to recurrent childhood asthma in Yancheng, China: a hospital-based-control study. Environ Sci Pollut Res 30:102212\u2013102221","journal-title":"Environ Sci Pollut Res"},{"key":"3946_CR164","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1289\/ehp.10576","volume":"116","author":"Z Zhao","year":"2008","unstructured":"Zhao Z, Zhang Z, Wang Z, Ferm M, Liang Y, Norb\u00e4ck D (2008) Asthmatic symptoms among pupils in relation to winter indoor and outdoor air pollution in schools in Taiyuan, China. Environ Health Perspect 116:90\u201397","journal-title":"Environ Health Perspect"}],"container-title":["Archives of Toxicology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00204-024-03946-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00204-024-03946-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00204-024-03946-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,12]],"date-time":"2025-02-12T07:37:57Z","timestamp":1739345877000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00204-024-03946-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,19]]},"references-count":164,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,3]]}},"alternative-id":["3946"],"URL":"https:\/\/doi.org\/10.1007\/s00204-024-03946-5","relation":{},"ISSN":["0340-5761","1432-0738"],"issn-type":[{"value":"0340-5761","type":"print"},{"value":"1432-0738","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,19]]},"assertion":[{"value":"11 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 December 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"PW declares no actual or potential financial conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"PW thanks the National Research Centre for the Working Environment (Denmark) for providing facilities to finalize this review. I thank Dr. Birger Heinzow for valuable comments.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}