{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T09:08:44Z","timestamp":1790672924046,"version":"4.1.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"21","license":[{"start":{"date-parts":[[2016,6,18]],"date-time":"2016-06-18T00:00:00Z","timestamp":1466208000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2016,8]]},"DOI":"10.1007\/s00216-016-9691-9","type":"journal-article","created":{"date-parts":[[2016,6,18]],"date-time":"2016-06-18T04:49:40Z","timestamp":1466225380000},"page":"5677-5687","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Combined use of direct analysis in real-time\/Orbitrap mass spectrometry and micro-Raman spectroscopy for the comprehensive characterization of real explosive samples"],"prefix":"10.1007","volume":"408","author":[{"given":"Maxime C.","family":"Bridoux","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adri\u00e1n","family":"Schwarzenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S\u00e9bastien","family":"Schramm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard B.","family":"Cole","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,6,18]]},"reference":[{"key":"9691_CR1","doi-asserted-by":"crossref","first-page":"7237","DOI":"10.1021\/ac101116r","volume":"82","author":"CM Mahoney","year":"2010","unstructured":"Mahoney CM, Fahey AJ, Steffens KL, Benner BA, Lareau RT. Characterization of composition C4 explosives using time-of-flight secondary ion mass spectrometry and X-ray photoelectron spectroscopy. Anal Chem. 2010;82:7237\u201348.","journal-title":"Anal Chem"},{"key":"9691_CR2","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1002\/prep.200900084","volume":"35","author":"JM Nilles","year":"2010","unstructured":"Nilles JM, Connell TR, Stokes ST, Dupont H. Explosives detection using direct analysis in real time (DART) mass spectrometry. Propellants Explos Pyrotech. 2010;35:446\u201361.","journal-title":"Propellants Explos Pyrotech"},{"key":"9691_CR3","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.forsciint.2013.07.006","volume":"232","author":"E Sisco","year":"2013","unstructured":"Sisco E, Dake J, Bridge C. Screening for trace explosives by AccuTOF\u2122-DART\u00ae: an in-depth validation study. Forensic Sci Int. 2013;232:160\u20138.","journal-title":"Forensic Sci Int"},{"key":"9691_CR4","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1002\/jrs.2649","volume":"41","author":"S Botti","year":"2010","unstructured":"Botti S, Cantarini L, Palucci A. Surface-enhanced Raman spectroscopy for trace-level detection of explosives. J Raman Spectrosc. 2010;41:866\u201386.","journal-title":"J Raman Spectrosc"},{"key":"9691_CR5","doi-asserted-by":"crossref","first-page":"2009","DOI":"10.1002\/jrs.2360","volume":"40","author":"EMA Ali","year":"2009","unstructured":"Ali EMA, Edwards HGM, Scowen IJ. Detection of explosives on human nail using confocal Raman microscopy. J Raman Spectrosc. 2009;40:2009\u201314.","journal-title":"J Raman Spectrosc"},{"key":"9691_CR6","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1002\/jrs.2574","volume":"41","author":"NA Hatab","year":"2010","unstructured":"Hatab NA, Eres G, Hatzinger PB, Gu B. Detection and analysis of cyclotrimethylenetrinitramine (RDX) in environmental samples by surface-enhanced Raman spectroscopy. J Raman Spectrosc. 2010;41:1131\u201336.","journal-title":"J Raman Spectrosc"},{"key":"9691_CR7","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1002\/jrs.4203","volume":"44","author":"S Botti","year":"2013","unstructured":"Botti S, Almaviva S, Cantarini L, Palucci A, Puiu A, Rufoloni A. Trace level detection and identification of nitro-based explosives by surface-enhanced Raman spectroscopy. J Raman Spectrosc. 2013;44:463\u201368.","journal-title":"J. Raman. Spectrosc."},{"key":"9691_CR8","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1007\/s00216-006-0640-x","volume":"387","author":"HGM Edward","year":"2007","unstructured":"Edward HGM, Stern B, Villar SEJ, David AR. Combined FT\u2013Raman spectroscopic and mass spectrometric study of ancient Egyptian sarcophagal fragments. Anal Bioanal Chem. 2007;387:829\u201336.","journal-title":"Anal Bioanal Chem"},{"key":"9691_CR9","doi-asserted-by":"crossref","first-page":"6732","DOI":"10.1039\/c3an01135f","volume":"138","author":"SR Fagerer","year":"2013","unstructured":"Fagerer SR, Schmid T, Ibanez AJ, Pabst M, Steinhoff R, Jefimovs K, et al. Analysis of single algal cells by combining mass spectrometry with Raman and fluorescence mapping. Analyst. 2013;138:6732\u20136.","journal-title":"Analyst"},{"key":"9691_CR10","doi-asserted-by":"crossref","first-page":"L915","DOI":"10.1143\/JJAP.43.L915","volume":"43","author":"KT Esaka","year":"2004","unstructured":"Esaka KT, Esaka F, Inagawa J, Iguchi K, Lee CG, Sakurai S, et al. Application of fission track technique for the analysis of individual particles containing uranium in safeguard swipe samples. Jap J Appl Phys. 2004;43:L915\u20136.","journal-title":"Jap J Appl Phys"},{"key":"9691_CR11","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1111\/1556-4029.12276","volume":"58","author":"JR Swider","year":"2013","unstructured":"Swider JR. Optimizing Accu time-of-flight\/direct analysis in real time for explosive residue analysis. J Forensic Sci. 2013;58:1601\u201306.","journal-title":"J Forensic Sci"},{"key":"9691_CR12","doi-asserted-by":"crossref","first-page":"2057","DOI":"10.1002\/rcm.6664","volume":"27","author":"MC Bridoux","year":"2013","unstructured":"Bridoux MC, Machuron-Mandard X. Capabilities and limitations of direct analysis in real time orbitrap mass spectrometry and tandem mass spectrometry for the analysis of synthetic and natural polymers. Rapid Commun Mass Spectrom. 2013;27:2057\u201370.","journal-title":"Rapid Commun Mass Spectrom"},{"key":"9691_CR13","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1002\/(SICI)1097-4555(199909)30:9<827::AID-JRS454>3.0.CO;2-S","volume":"30","author":"RH Clarke","year":"1999","unstructured":"Clarke RH, Londhe S, Premasiri WR, Womble ME. Low-resolution Raman spectroscopy: instrumentation and applications in chemical analysis. J Raman Spectrosc. 1999;30:827\u201332.","journal-title":"J Raman Spectrosc"},{"key":"9691_CR14","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.vibspec.2005.04.002","volume":"38","author":"MR Lewis","year":"2005","unstructured":"Lewis MR, Lewis IR, Griffiths PR. Evaluation of a dispersive Raman spectrometer with a Ge array detector and a 1064 nm laser for the study of explosives. Vib Spectrosc. 2005;38:11\u20138.","journal-title":"Vib Spectrosc"},{"key":"9691_CR15","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1021\/j150647a005","volume":"88","author":"RJ Karpowicz","year":"1984","unstructured":"Karpowicz RJ, Brill TB. Comparison of the molecular structure of hexahydro-1,3,5-trinitro-s-triazine in the vapor, solution and solid phases. J Phys Chem. 1984;88:348\u201352.","journal-title":"J Phys Chem"},{"key":"9691_CR16","doi-asserted-by":"crossref","first-page":"8799","DOI":"10.1021\/jp0373550","volume":"108","author":"P Torres","year":"2004","unstructured":"Torres P, Mercado L, Cottes I, Hernandez SP, Min N, Santana A, et al. Vibrational spectroscopy study of \u03b2 and \u03b1 RDX deposits. J Phys Chem B. 2004;108:8799\u2013805.","journal-title":"J Phys Chem B"},{"key":"9691_CR17","doi-asserted-by":"crossref","first-page":"1854","DOI":"10.1366\/0003702971939686","volume":"51","author":"IR Lewis","year":"1997","unstructured":"Lewis IR, Daniel Jr NW, Griffiths PR. Interpretation of Raman spectra of nitro-containing explosive materials. Part I: group frequency and structural class membership. Appl Spectrosc. 1997;51:1854\u201367.","journal-title":"Appl Spectrosc"},{"key":"9691_CR18","doi-asserted-by":"crossref","first-page":"1868","DOI":"10.1366\/0003702971939695","volume":"51","author":"NW Daniel Jr","year":"1997","unstructured":"Daniel Jr NW, Lewis IR, Griffith PR. Interpretation of Raman spectra of nitro-containing explosive materials. Part II: the implementation of neural, fuzzy, and statistical models for unsupervised pattern recognition. Appl Spectrosc. 1997;51:1868\u201379.","journal-title":"Appl Spectrosc"},{"key":"9691_CR19","doi-asserted-by":"crossref","first-page":"6197","DOI":"10.1021\/jp004425j","volume":"105","author":"YA Gruzdkov","year":"2001","unstructured":"Gruzdkov YA, Gupta YM. Vibrational properties and structure of pentaerythritol tetranitrate. J Phys Chem A. 2001;105:6197\u2013202.","journal-title":"J Phys Chem A"},{"key":"9691_CR20","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1016\/j.talanta.2008.09.060","volume":"77","author":"O Vigneau","year":"2009","unstructured":"Vigneau O, Machuron-Mandard X. A LC\u2013MS method allowing the analysis of HMX and RDX present at the picogram level in natural aqueous samples without a concentration step. Talanta. 2009;77:1609\u201313.","journal-title":"Talanta"},{"key":"9691_CR21","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.jasms.2008.09.016","volume":"20","author":"L Song","year":"2009","unstructured":"Song L, Dykstra AB, Yao H, Bartmess JE. Ionization mechanism of negative ion-direct analysis in real time: a comparative study with negative ion-atmospheric pressure photoionization. J Am Soc Mass Spectrom. 2009;20:42\u201350.","journal-title":"J Am Soc Mass Spectrom"},{"key":"9691_CR22","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1021\/ac0108818","volume":"74","author":"Y Cai","year":"2002","unstructured":"Cai Y, Cole RB. Stabilization of anionic adducts in negative ion electrospray mass spectrometry. Anal Chem. 2002;74:985\u201391.","journal-title":"Anal Chem"},{"key":"9691_CR23","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1002\/jms.3337","volume":"49","author":"C Hubert","year":"2014","unstructured":"Hubert C, Schwarzenberg A, Dossmann H, Cole RB, Machuron-Mandard X, Tabet J-C. Clarification of the 30 Da releases from the [M-H]\u2212 and M\u2212\u2022 ions of trinitrotoluene by electrospray high resolution mass spectrometry. J Mass Spectrom. 2014;49:327\u201330.","journal-title":"J Mass Spectrom"},{"key":"9691_CR24","doi-asserted-by":"crossref","DOI":"10.1002\/9783527628803","volume-title":"High energy materials: propellants, explosives and pyrotechnics","author":"JP Agarwal","year":"2010","unstructured":"Agarwal JP. High energy materials: propellants, explosives and pyrotechnics. Wiley-VCH: Weinheim; 2010."},{"key":"9691_CR25","volume-title":"Energetic polymers. Binders and plasticizers for enhancing performance","author":"HG Ang","year":"2010","unstructured":"Ang HG, Pisharath S. Energetic polymers. Binders and plasticizers for enhancing performance. Wiley-VCH: Weinheim; 2010."},{"key":"9691_CR26","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1021\/cr9901081","volume":"101","author":"SD Hanton","year":"2001","unstructured":"Hanton SD. Mass spectrometry of polymers and polymer surfaces. Chem Rev. 2001;101:527\u201369.","journal-title":"Chem Rev"},{"key":"9691_CR27","doi-asserted-by":"crossref","first-page":"4555","DOI":"10.1021\/ma200542p","volume":"44","author":"X Li","year":"2011","unstructured":"Li X, Guo L, Casiano-Maldonado M, Zhang D, Wesdemiotis C. Top-down multidimensional mass spectrometry methods for synthetic polymer analysis. Macromolecules. 2011;44:4555\u201364.","journal-title":"Macromolecules"},{"key":"9691_CR28","doi-asserted-by":"crossref","first-page":"3957","DOI":"10.1021\/ac0606249","volume":"78","author":"PM Peacock","year":"2006","unstructured":"Peacock PM, McEwen CN. Mass spectrometry of synthetic polymers. Anal Chem. 2006;78:3957\u201364.","journal-title":"Anal Chem"},{"key":"9691_CR29","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.trac.2013.04.012","volume":"50","author":"CW Klampfl","year":"2013","unstructured":"Klampfl CW. Mass spectrometry as a useful tool for the analysis of stabilizers in polymer materials. TrAC Trend Anal Chem. 2013;50:53\u201364.","journal-title":"TrAC Trend Anal Chem"},{"key":"9691_CR30","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1039\/b514057a","volume":"8","author":"M Nefliu","year":"2006","unstructured":"Nefliu M, Venter A, Cooks RG. Desorption electrospray ionization and electrosonic spray ionization for solid- and solution-phase analysis of industrial polymers. Chem Commun. 2006;8:888\u201390.","journal-title":"Chem Commun"},{"key":"9691_CR31","doi-asserted-by":"crossref","first-page":"1693","DOI":"10.1002\/rcm.3008","volume":"21","author":"JP Williams","year":"2007","unstructured":"Williams JP, Hilton GR, Thalassinos K, Jackson AT, Scrivens JH. The rapid characterisation of poly(ethylene glycol) oligomers using desorption electrospray ionisation tandem mass spectrometry combined with novel product ion peak assignment software. Rapid Commun Mass Spectrom. 2007;21:1693\u2013704.","journal-title":"Rapid Commun Mass Spectrom"},{"key":"9691_CR32","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1002\/jms.3057","volume":"47","author":"M Friia","year":"2012","unstructured":"Friia M, Legros V, Tortajada J, Buchmann W. Desorption electrospray ionization - orbitrap mass spectrometry of synthetic polymers and copolymers. J Mass Spectrom. 2012;47:1023\u201333.","journal-title":"J Mass Spectrom"},{"key":"9691_CR33","doi-asserted-by":"crossref","first-page":"2829","DOI":"10.1002\/rcm.4194","volume":"23","author":"T Rothenbacher","year":"2009","unstructured":"Rothenbacher T, Schwack W. Rapid and nondestructive analysis of phthalic acid esters in toys made of poly(vinyl chloride) by direct analysis in real time single-quadrupole massspectrometry. Rapid Commun Mass Spectrom. 2009;23:2829\u201335.","journal-title":"Rapid Commun Mass Spectrom"}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-016-9691-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00216-016-9691-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-016-9691-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T16:37:17Z","timestamp":1498322237000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00216-016-9691-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6,18]]},"references-count":33,"journal-issue":{"issue":"21","published-print":{"date-parts":[[2016,8]]}},"alternative-id":["9691"],"URL":"https:\/\/doi.org\/10.1007\/s00216-016-9691-9","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,6,18]]}}}