{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T03:31:46Z","timestamp":1788406306216,"version":"build-2803163510"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2017,3,3]],"date-time":"2017-03-03T00:00:00Z","timestamp":1488499200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100006141","name":"Military University of Technology","doi-asserted-by":"crossref","award":["PBS\/23-656\/2016"],"award-info":[{"award-number":["PBS\/23-656\/2016"]}],"id":[{"id":"10.13039\/501100006141","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100006141","name":"Military University of Technology","doi-asserted-by":"crossref","award":["RMN\/08-787\/2016"],"award-info":[{"award-number":["RMN\/08-787\/2016"]}],"id":[{"id":"10.13039\/501100006141","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2017,5]]},"DOI":"10.1007\/s00216-017-0265-2","type":"journal-article","created":{"date-parts":[[2017,3,3]],"date-time":"2017-03-03T07:42:45Z","timestamp":1488526965000},"page":"3223-3231","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["Nitrogen oxides as dopants for the detection of aromatic compounds with ion mobility spectrometry"],"prefix":"10.1007","volume":"409","author":[{"given":"Urszula","family":"Gaik","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mika","family":"Sillanp\u00e4\u00e4","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zygfryd","family":"Witkiewicz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaros\u0142aw","family":"Puton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,3,3]]},"reference":[{"key":"265_CR1","doi-asserted-by":"crossref","DOI":"10.1201\/b16109","volume-title":"Ion mobility spectrometry","author":"GA Eiceman","year":"2013","unstructured":"Eiceman GA, Karpas Z, Hill HH. Ion mobility spectrometry. 3rd ed. Boca Raton: CRC Press Taylor & Francis Group; 2013.","edition":"3"},{"key":"265_CR2","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1039\/C4AN01100G","volume":"140","author":"R Cumeras","year":"2015","unstructured":"Cumeras R, Figueras E, Davis CE, Baumbach JI, Gr\u00e0cia I. Review on ion mobility spectrometry. Part 1: current instrumentation. Analyst. 2015;140:1376\u201390.","journal-title":"Analyst"},{"key":"265_CR3","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.aca.2011.07.021","volume":"703","author":"S Armenta","year":"2011","unstructured":"Armenta S, Alcala M, Blanco M. A review of recent, unconventional applications of ion mobility spectrometry (IMS). Anal Chim Acta. 2011;703:114\u201323.","journal-title":"Anal Chim Acta"},{"key":"265_CR4","doi-asserted-by":"publisher","first-page":"9594","DOI":"10.1021\/ac100931n","volume":"82","author":"MA M\u00e4kinen","year":"2010","unstructured":"M\u00e4kinen MA, Anttalainen OA, Sillanp\u00e4\u00e4 MET. Ion mobility spectrometry and its applications in detection of chemical warfare agents. Anal Chem. 2010;82:9594\u2013600.","journal-title":"Anal Chem"},{"key":"265_CR5","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/S0301-2115(03)00210-0","volume":"111","author":"W Chaim","year":"2003","unstructured":"Chaim W, Karpas Z, Lorber A. New technology for diagnosis of bacterial vaginosis. Eur J Obstet Gynecol Reprod Biol. 2003;111:83\u20137.","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"265_CR6","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1002\/(SICI)1520-6521(1997)1:3<119::AID-FACT2>3.0.CO;2-S","volume":"1","author":"HH Hill Jr","year":"1997","unstructured":"Hill Jr HH, Simpson G. Capabilities and limitations of ion mobility spectrometry for field screening applications. Field Anal Chem Technol. 1997;1:119\u201334.","journal-title":"Field Anal Chem Technol"},{"key":"265_CR7","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1016\/j.theriogenology.2012.03.022","volume":"78","author":"S Marcus","year":"2012","unstructured":"Marcus S, Menda A, Shore L, Cohen G, Atweh E, Friedman N, et al. A novel method for the diagnosis of bacterial contamination in the anterior vagina of sows based on measurement of biogenic amines by ion mobility spectrometry: a field trial. Theriogenology. 2012;78:753\u20138.","journal-title":"Theriogenology"},{"key":"265_CR8","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1248\/jhs.49.325","volume":"49","author":"A Miki","year":"2003","unstructured":"Miki A, Katagi M, Tsuchihashi H. Recent improvements in forensic hair analysis for illicit drugs. J Health Sci. 2003;49:325\u201332.","journal-title":"J Health Sci"},{"key":"265_CR9","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.ejogrb.2012.03.022","volume":"163","author":"JD Sobel","year":"2012","unstructured":"Sobel JD, Karpas Z, Lorber A. Diagnosing vaginal infections through measurement of biogenic amines by ion mobility spectrometry. Eur J Obstet Gynecol Reprod Biol. 2012;163:81\u20134.","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"265_CR10","doi-asserted-by":"crossref","first-page":"390A","DOI":"10.1021\/ac041665c","volume":"76","author":"GA Eiceman","year":"2004","unstructured":"Eiceman GA, Stone JA. Ion mobility spectrometers in national defence. Anal Chem. 2004;76:390A\u20137A.","journal-title":"Anal Chem"},{"key":"265_CR11","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1016\/j.talanta.2007.04.058","volume":"73","author":"AB Kanu","year":"2007","unstructured":"Kanu AB, Hill Jr HH. Identity confirmation of drugs and explosives in ion mobility spectrometry using a secondary drift gas. Talanta. 2007;73:692\u20139.","journal-title":"Talanta"},{"key":"265_CR12","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1016\/S0039-9140(00)00565-8","volume":"54","author":"RG Ewing","year":"2001","unstructured":"Ewing RG, Atkinson DA, Eiceman GA, Ewing GJ. A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds. Talanta. 2001;54:515\u201329.","journal-title":"Talanta"},{"key":"265_CR13","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/0165-9936(94)87064-0","volume":"13","author":"RB Turner","year":"1994","unstructured":"Turner RB, Brokenshire JL. Hand-held ion mobility spectrometers. Trends Anal Chem. 1994;13:275\u201380.","journal-title":"Trends Anal Chem"},{"key":"265_CR14","doi-asserted-by":"publisher","first-page":"978","DOI":"10.1016\/j.talanta.2008.05.031","volume":"76","author":"J Puton","year":"2008","unstructured":"Puton J, Nousiainen M, Sillanp\u00e4\u00e4 M. Ion mobility spectrometers with doped gases. Talanta. 2008;76:978\u201387.","journal-title":"Talanta"},{"key":"265_CR15","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/j.trac.2016.06.009","volume":"82","author":"E Waraksa","year":"2016","unstructured":"Waraksa E, Perycz U, Namie\u015bnik J, Sillanp\u00e4\u00e4 M, Dymerski T, W\u00f3jtowicz M, et al. Dopants and gas modifiers in ion mobility spectrometry. TrAC Trends Anal Chem. 2016;82:237\u201349.","journal-title":"TrAC Trends Anal Chem"},{"key":"265_CR16","doi-asserted-by":"publisher","first-page":"1794","DOI":"10.1021\/ac00275a010","volume":"56","author":"CJ Proctor","year":"1984","unstructured":"Proctor CJ, Todd JFJ. Alternative reagent ions for plasma chromatography. Anal Chem. 1984;56:1794\u20137.","journal-title":"Anal Chem"},{"key":"265_CR17","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/S0003-2670(02)00378-1","volume":"463","author":"Z Karpas","year":"2002","unstructured":"Karpas Z, Tilman B, Gdalevsky R, Lorber A. Determination of volatile biogenic amines in muscle food products by ion mobility spectrometry. Anal Chim Acta. 2002;463:155\u201363.","journal-title":"Anal Chim Acta"},{"key":"265_CR18","doi-asserted-by":"publisher","first-page":"1696","DOI":"10.1021\/ac00061a011","volume":"65","author":"GA Eiceman","year":"1993","unstructured":"Eiceman GA, Salazar MR, Rodriguez MR, Limero TF, Beck SW, Cross JH, et al. Ion mobility spectrometry of hydrazine, monomethylhydrazine, and ammonia in air with 5-nonanone reagent gas. Anal Chem. 1993;65:1696\u2013702.","journal-title":"Anal Chem"},{"key":"265_CR19","doi-asserted-by":"crossref","first-page":"9131","DOI":"10.1021\/ac3018108","volume":"84","author":"J Puton","year":"2012","unstructured":"Puton J, Holopainen SI, M\u00e4kinen MA, Sillanp\u00e4\u00e4 MET. Quantitative response of IMS detector for mixtures containing two active components. Anal Chem. 2012;84:9131\u20138.","journal-title":"Anal Chem"},{"key":"265_CR20","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.ijms.2014.09.008","volume":"373","author":"J Puton","year":"2014","unstructured":"Puton J, Augustyniak D, Perycz U, Witkiewicz Z. Conservation of dimer peak intensity in ion mobility spectrometers with ketone-doped carrier gas. Int J Mass Spectrom. 2014;373:43\u20139.","journal-title":"Int J Mass Spectrom"},{"key":"265_CR21","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.snb.2013.06.079","volume":"188","author":"S Zimmermann","year":"2013","unstructured":"Zimmermann S, Gunzer F. Simultaneous detection of benzene and toluene using a pulsed ion mobility spectrometer. Sensors Actuators B Chem. 2013;188:106\u201310.","journal-title":"Sensors Actuators B Chem"},{"key":"265_CR22","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1002\/1520-6521(2000)4:4<157::AID-FACT2>3.0.CO;2-#","volume":"4","author":"S Sielemann","year":"2000","unstructured":"Sielemann S, Baumbach JI, Schmidt H, Pilzecker P. Quantitative analysis of benzene, toluene, and m-xylene with the use of a UV-ion mobility spectrometer. Field Anal Chem Technol. 2000;4:157\u201369.","journal-title":"Field Anal Chem Technol"},{"key":"265_CR23","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.1016\/S0584-8547(02)00110-6","volume":"57","author":"F Li","year":"2002","unstructured":"Li F, Xie Z, Schmidt H, Sielemann S, Baumbach JI. Ion mobility spectrometer for online monitoring of trace compounds. Spectrochim Acta Part B At Spectrosc. 2002;57:1563\u201374.","journal-title":"Spectrochim Acta Part B At Spectrosc"},{"key":"265_CR24","doi-asserted-by":"crossref","unstructured":"Walte A, Ungethum B, Munchmeyer W. Measuring toxic gases in low concentrations with IMS\u2014overview with the technology, its advantages and disadvantages. 11 Dresdner Sens Symp. 2013;119\u2013126.","DOI":"10.5162\/11dss2013\/7.1"},{"key":"265_CR25","doi-asserted-by":"publisher","first-page":"1748","DOI":"10.1109\/JSEN.2011.2179117","volume":"12","author":"W Baether","year":"2012","unstructured":"Baether W, Zimmermann S, Gunzer F. Pulsed ion mobility spectrometer for the detection of toluene 2,4-diisocyanate in ambient air. IEEE Sens J. 2012;12:1748\u201354.","journal-title":"IEEE Sens J"},{"key":"265_CR26","doi-asserted-by":"publisher","first-page":"5327","DOI":"10.1021\/ac300722s","volume":"84","author":"M Sabo","year":"2012","unstructured":"Sabo M, Matej\u010d\u00edk \u0160. Corona discharge ion mobility spectrometry with orthogonal acceleration time of flight mass spectrometry for monitoring of volatile organic compounds. Anal Chem. 2012;84:5327\u201334.","journal-title":"Anal Chem"},{"key":"265_CR27","doi-asserted-by":"publisher","first-page":"6907","DOI":"10.1039\/c3an00964e","volume":"138","author":"M Sabo","year":"2013","unstructured":"Sabo M, Matej\u010d\u00edk \u0160. A corona discharge atmospheric pressure chemical ionization source with selective NO+ formation and its application for monoaromatic VOC detection. Analyst. 2013;138:6907\u201312.","journal-title":"Analyst"},{"key":"265_CR28","doi-asserted-by":"publisher","first-page":"808","DOI":"10.1109\/TPS.2005.844530","volume":"33","author":"J Chen","year":"2005","unstructured":"Chen J, Wang P. Effect of relative humidity on electron distribution and ozone production by DC coronas in air. IEEE Trans Plasma Sci. 2005;33:808\u201312.","journal-title":"IEEE Trans Plasma Sci"},{"key":"265_CR29","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1002\/mas.20033","volume":"24","author":"D Smith","year":"2005","unstructured":"Smith D, Spanel P. Selected ion flow tube mass spectrometry (SIFT-IMS) for on-line trace gas analysis. Mass Spectrom Rev. 2005;24:661\u2013700.","journal-title":"Mass Spectrom Rev"},{"key":"265_CR30","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1021\/ac50025a036","volume":"50","author":"SC Subba Rao","year":"1978","unstructured":"Subba Rao SC, Fenselau C. Evaluation of benzene as a charge exchange reagent. Anal Chem. 1978;50:511\u20135.","journal-title":"Anal Chem"},{"key":"265_CR31","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1007\/s12127-013-0137-1","volume":"16","author":"M Darzi","year":"2013","unstructured":"Darzi M, Tabrizchi M. An NO+ reactant ion source for ion mobility spectrometry. Int J Ion Mobil Spectrom. 2013;16:275\u201380.","journal-title":"Int J Ion Mobil Spectrom"},{"key":"265_CR32","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1021\/ac60342a020","volume":"46","author":"FW Karasek","year":"1974","unstructured":"Karasek FW, Denney DW. Role of nitric oxyde in positive reactant ions in plasma chromatography. Anal Chem. 1974;46:633\u20137.","journal-title":"Anal Chem"},{"key":"265_CR33","first-page":"22","volume":"5","author":"GA Eiceman","year":"2002","unstructured":"Eiceman GA, Kelly K, Nazarov EG. Nitric oxide as a reagent gas in ion mobility spectrometry. Int J Ion Mobil Spectrom. 2002;5:22\u201330.","journal-title":"Int J Ion Mobil Spectrom"},{"key":"265_CR34","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/S0003-2670(98)00674-6","volume":"381","author":"D Young","year":"1999","unstructured":"Young D, Thomas CLP, Breach J, Brittain AH, Eiceman GA. Extending the concentration and linear dynamic range of ion mobility spectrometry with a sheath flow inlet. Anal Chim Acta. 1999;381:69\u201383.","journal-title":"Anal Chim Acta"},{"key":"265_CR35","unstructured":"Clement RE, Jr HHH, Siu KWM. Instrumentation for trace organic monitoring. CRC Press, Boca Raton; 1991."},{"key":"265_CR36","doi-asserted-by":"publisher","first-page":"2006","DOI":"10.1021\/ac50036a018","volume":"50","author":"SH Kim","year":"1978","unstructured":"Kim SH, Betty KR, Karasek FW. Mobility behavior and composition of hydrated positive reactant ions in plasma chromatography with nitrogen carrier gas. Anal Chem. 1978;50:2006\u201312.","journal-title":"Anal Chem"},{"key":"265_CR37","unstructured":"NIST WebBook. http:\/\/webbook.nist.gov\/ . Accessed 18 May 2016"},{"key":"265_CR38","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1016\/j.snb.2015.04.102","volume":"218","author":"H Borsdorf","year":"2015","unstructured":"Borsdorf H, Fiedler P, Mayer T. The effect of humidity on gas sensing with ion mobility spectrometry. Sensors Actuators B Chem. 2015;218:184\u201390.","journal-title":"Sensors Actuators B Chem"}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-017-0265-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00216-017-0265-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-017-0265-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,25]],"date-time":"2022-07-25T03:42:22Z","timestamp":1658720542000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00216-017-0265-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,3]]},"references-count":38,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2017,5]]}},"alternative-id":["265"],"URL":"https:\/\/doi.org\/10.1007\/s00216-017-0265-2","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,3]]}}}