{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T03:19:38Z","timestamp":1787627978720,"version":"build-2736575974"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"27","license":[{"start":{"date-parts":[[2018,8,31]],"date-time":"2018-08-31T00:00:00Z","timestamp":1535673600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2018,8,31]],"date-time":"2018-08-31T00:00:00Z","timestamp":1535673600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"UMB-UMBC Research and Innovation Partnership Grant Program"},{"DOI":"10.13039\/100009633","name":"Eunice Kennedy Shriver National Institute of Child Health and Human Development","doi-asserted-by":"publisher","award":["R41HD088223"],"award-info":[{"award-number":["R41HD088223"]}],"id":[{"id":"10.13039\/100009633","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2018,11]]},"DOI":"10.1007\/s00216-018-1336-8","type":"journal-article","created":{"date-parts":[[2018,8,31]],"date-time":"2018-08-31T04:44:55Z","timestamp":1535690695000},"page":"7249-7260","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Minimally invasive technique for measuring transdermal glucose with a fluorescent biosensor"],"prefix":"10.1007","volume":"410","author":[{"given":"Sheniqua","family":"Brown","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paige N.","family":"Zambrana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xudong","family":"Ge","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dayanand","family":"Bagdure","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Audra L.","family":"Stinchcomb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Govind","family":"Rao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leah","family":"Tolosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,8,31]]},"reference":[{"key":"1336_CR1","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1111\/j.1399-5448.2009.00569.x","volume":"10","author":"J Wolfsdorf","year":"2009","unstructured":"Wolfsdorf J, Craig ME, Daneman D, Dunger D, Edge J, Lee W, et al. Diabetic ketoacidosis in children and adolescents with diabetes. Pediatr Diabetes. 2009;10:118\u201333. https:\/\/doi.org\/10.1111\/j.1399-5448.2009.00569.x .","journal-title":"Pediatr Diabetes"},{"issue":"3","key":"1336_CR2","doi-asserted-by":"publisher","first-page":"1176","DOI":"10.1542\/peds.2006-0347","volume":"118","author":"HG Piper","year":"2006","unstructured":"Piper HG, Alexander JL, Shukla A, Pigula F, Costello JM, Laussen PC, et al. Real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery. Pediatrics. 2006;118(3):1176\u201384. http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/16951013","journal-title":"Pediatrics"},{"issue":"2","key":"1336_CR3","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1097\/PCC.0b013e3181668b33","volume":"9","author":"HF Allen","year":"2008","unstructured":"Allen HF, Rake A, Roy M, Brenner D, McKiernan CA. Prospective detection of hyperglycemia in critically ill children using continuous glucose monitoring*. Pediatr Crit Care Med. 2008;9(2):153\u20138. https:\/\/insights.ovid.com\/crossref?an=00130478-200803000-00003","journal-title":"Pediatr Crit Care Med"},{"issue":"66","key":"1336_CR4","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1177\/193229680900300611","volume":"33","author":"JI Joseph","year":"2009","unstructured":"Joseph JI, Hipszer B, Mraovic B, Chervoneva I, Joseph M, Grunwald Z. Clinical need for continuous glucose monitoring in the hospital. J Diabetes Sci Technol. 2009;33(66):1309\u201318. https:\/\/doi.org\/10.1177\/193229680900300611 .","journal-title":"J Diabetes Sci Technol"},{"key":"1336_CR5","unstructured":"Bridges BC, Preissig CM, Maher KO, Rigby MR. Continuous glucose monitors prove highly accurate in critically ill children https:\/\/ccforum.biomedcentral.com\/track\/pdf\/10.1186\/cc9280"},{"issue":"3","key":"1336_CR6","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1016\/j.jpeds.2010.02.003","volume":"26","author":"R Barrio Castellanos","year":"2010","unstructured":"Barrio Castellanos R, Harris DL, Battin MR, Weston PJ, Harding JE. Continuous glucose monitoring in newborn babies at risk of hypoglycemia. Av en Diabetol. 2010;26(3):209\u201310. https:\/\/doi.org\/10.1016\/j.jpeds.2010.02.003 .","journal-title":"Av en Diabetol"},{"issue":"3","key":"1336_CR7","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1177\/193229681000400317","volume":"4","author":"M Signal","year":"2010","unstructured":"Signal M, Pretty CG, Chase JG, Le Compte A, Shaw GM. Continuous glucose monitors and the burden of tight glycemic control in critical care: can they cure the time cost? J Diabetes Sci Technol. 2010;4(3):625\u201335. Available from: http:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2901040&tool=pmcentrez&rendertype=abstract","journal-title":"J Diabetes Sci Technol"},{"issue":"1","key":"1336_CR8","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1177\/193229681000400103","volume":"4","author":"CG Pretty","year":"2010","unstructured":"Pretty CG, Chase JG, Le Compte A, Shaw GM, Signal M. Hypoglycemia detection in critical care using continuous glucose monitors: an in silico proof of concept analysis. J Diabetes Sci Technol. 2010;4(1):15\u201324. Available from: http:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=2825620&tool=pmcentrez&rendertype=abstract","journal-title":"J Diabetes Sci Technol"},{"issue":"4","key":"1336_CR9","doi-asserted-by":"publisher","first-page":"F307","DOI":"10.1136\/adc.2004.051979","volume":"90","author":"K Beardsall","year":"2005","unstructured":"Beardsall K, Ogilvy-Stuart AL, Ahluwalia J, Thompson M, Dunger DB. The continuous glucose monitoring sensor in neonatal intensive care. Arch Dis Child Fetal Neonatal Ed. 2005;90(4):F307\u201310. Available from: http:\/\/fn.bmj.com\/content\/90\/4\/F307.long","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"1","key":"1336_CR10","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1177\/193229681200600102","volume":"6","author":"Kupper A. Wintergerst","year":"2012","unstructured":"Wintergerst KA, Foster MB, Sullivan JE, Woods CR, Affiliations A. Association of hyperglycemia, glucocorticoids, and insulin use with morbidity and mortality in the pediatric intensive care unit. J Diabetes Sci Technol. 2012;6(1) https:\/\/doi.org\/10.1177\/193229681200600102 .","journal-title":"Journal of Diabetes Science and Technology"},{"issue":"1","key":"1336_CR11","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1542\/peds.2005-1819","volume":"118","author":"KA Wintergerst","year":"2006","unstructured":"Wintergerst KA, Buckingham B, Gandrud L, Wong BJ, Kache S, Wilson DM. Association of hypoglycemia, hyperglycemia, and glucose variability with morbidity and death in the pediatric intensive care unit. Pediatrics. 2006;118(1):173\u20139. Available from: http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/16818563","journal-title":"Pediatrics"},{"issue":"3","key":"1336_CR12","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1021\/bp070411k","volume":"24","author":"X Ge","year":"2008","unstructured":"Ge X, Rao G, Tolosa L. On the possibility of real-time monitoring of glucose in cell culture by microdialysis using a fluorescent glucose binding protein sensor. Biotechnol Prog. 2008;24(3):691\u20137.","journal-title":"Biotechnol Prog"},{"issue":"5","key":"1336_CR13","doi-asserted-by":"publisher","first-page":"1403","DOI":"10.1021\/ac035063p","volume":"76","author":"X Ge","year":"2004","unstructured":"Ge X, Tolosa L, Rao G. Dual-labeled glucose binding protein for ratiometric measurements of glucose. Anal Chem. 2004;76(5):1403\u201310.","journal-title":"Anal Chem"},{"issue":"1","key":"1336_CR14","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1177\/193229681300700102","volume":"7","author":"X Ge","year":"2013","unstructured":"Ge X, Rao G, Kostov Y, Kanjananimmanont S, Viscardi RM, Woo H, et al. Detection of trace glucose on the surface of a semipermeable membrane using a fluorescently labeled glucose-binding protein: a promising approach to noninvasive glucose monitoring. J Diabetes Sci Technol. 2013;7(1):4\u201312. http:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=3692211&tool=pmcentrez&rendertype=abstract","journal-title":"J Diabetes Sci Technol"},{"issue":"6","key":"1336_CR15","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1177\/193229680700100610","volume":"1","author":"X Ge","year":"2007","unstructured":"Ge X, Lam H, Modi SJ, LaCourse WR, Rao G, Tolosa L. Comparing the performance of the optical glucose assay based on glucose binding protein with high-performance anion-exchange chromatography with pulsed electrochemical detection: efforts to design a low-cost point-of-care glucose sensor. J Diabetes Sci Technol. 2007;1(6):864\u201372.","journal-title":"J Diabetes Sci Technol"},{"key":"1336_CR16","doi-asserted-by":"publisher","first-page":"e275","DOI":"10.7717\/peerj.275","volume":"2","author":"AV Fonin","year":"2014","unstructured":"Fonin AV, Stepanenko OV, Povarova OI, Volova CA, Philippova EM, Bublikov GS, et al. Spectral characteristics of the mutant form GGBP\/H152C of D-glucose\/D-galactose-binding protein labeled with fluorescent dye BADAN: influence of external factors. PeerJ. 2014;2:e275. Available from: https:\/\/peerj.com\/articles\/275","journal-title":"PeerJ"},{"issue":"1","key":"1336_CR17","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ab.2009.11.035","volume":"399","author":"F Khan","year":"2010","unstructured":"Khan F, Saxl TE, Pickup JC. Fluorescence intensity- and lifetime-based glucose sensing using an engineered high-Kd mutant of glucose\/galactose-binding protein. Anal Biochem. 2010;399(1):39\u201343. https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0003269709008112","journal-title":"Anal Biochem"},{"issue":"7","key":"1336_CR18","doi-asserted-by":"publisher","first-page":"1595","DOI":"10.1021\/cb500132g","volume":"9","author":"S Joel","year":"2014","unstructured":"Joel S, Turner KB, Daunert S. Glucose recognition proteins for glucose sensing at physiological concentrations and temperatures. ACS Chem Biol. 2014;9(7):1595\u2013602. https:\/\/doi.org\/10.1021\/cb500132g .","journal-title":"ACS Chem Biol"},{"issue":"1236","key":"1336_CR19","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1098\/rstb.1990.0016","volume":"326","author":"FA Quiocho","year":"1990","unstructured":"Quiocho FA. Atomic structures of periplasmic binding proteins and the high-affinity active transport systems in bacteria. Philos Trans R Soc Lond Ser B Biol Sci. 1990;326(1236):341\u201352. http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/1970641","journal-title":"Philos Trans R Soc Lond Ser B Biol Sci"},{"issue":"6","key":"1336_CR20","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1002\/bit.10830","volume":"84","author":"X Ge","year":"2003","unstructured":"Ge X, Tolosa L, Simpson J, Rao G. Genetically engineered binding proteins as biosensors for fermentation and cell culture. Biotechnol Bioeng. 2003;84(6):723\u201331.","journal-title":"Biotechnol Bioeng"},{"issue":"1","key":"1336_CR21","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1006\/abio.2001.5131","volume":"294","author":"LL Salins","year":"2001","unstructured":"Salins LL, Ware RA, Ensor CM, Daunert S. A novel reagentless sensing system for measuring glucose based on the galactose\/glucose-binding protein. Anal Biochem. 2001;294(1):19\u201326.","journal-title":"Anal Biochem"},{"issue":"2","key":"1336_CR22","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1177\/1932296813519994","volume":"8","author":"S Kanjananimmanont","year":"2014","unstructured":"Kanjananimmanont S, Ge X, Mupparapu K, Rao G, Potts R, Tolosa L. Passive diffusion of transdermal glucose: noninvasive glucose sensing using a fluorescent glucose binding protein. J Diabetes Sci Technol. 2014;8(2):291\u20138. http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/24876581","journal-title":"J Diabetes Sci Technol"},{"key":"1336_CR23","doi-asserted-by":"publisher","first-page":"3475","DOI":"10.1007\/s00216-017-0289-7","volume":"409","author":"C Tiangco","year":"2017","unstructured":"Tiangco C, Andar A, Quarterman J, Ge X, Sevilla Iii F, Rao G, et al. Measuring transdermal glucose levels in neonates by passive diffusion: an in vitro porcine skin model. Anal Bioanal Chem. 2017;409:3475\u201382. https:\/\/link.springer.com\/content\/pdf\/10.1007%2Fs00216-017-0289-7.pdf","journal-title":"Anal Bioanal Chem"},{"issue":"6","key":"1336_CR24","doi-asserted-by":"publisher","first-page":"1122","DOI":"10.1177\/193229680800200621","volume":"2","author":"P Khanna","year":"2008","unstructured":"Khanna P, Strom JA, Malone JI, Bhansali S. Microneedle-based automated therapy for diabetes mellitus. J Diabetes Sci Technol. 2008;2(6):1122\u20139. Available from: http:\/\/dst.sagepub.com\/content\/2\/6\/1122.abstract","journal-title":"J Diabetes Sci Technol"},{"issue":"1\u20132","key":"1336_CR25","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.mseb.2006.02.008","volume":"132","author":"AL Teo","year":"2006","unstructured":"Teo AL, Shearwood C, Ng KC, Lu J, Moochhala S. Transdermal microneedles for drug delivery applications. Mater Sci Eng B. 2006;132(1\u20132):151\u20134.","journal-title":"Mater Sci Eng B"},{"key":"1336_CR26","unstructured":"Yadav JD, Vaidya KA, Kulkarni PR, Raut RA. Microneedles: promising technique for transdermal drug delivery. Int J Pharm Bio Sci. 2011;2:684\u2013708."},{"issue":"8","key":"1336_CR27","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1021\/js980042+","volume":"87","author":"S Henry","year":"1998","unstructured":"Henry S, McAllister DV, Allen MG, Prausnitz MR. Microfabricated microneedles: a novel approach to transdermal drug delivery. J Pharm Sci. 1998;87(8):922\u20135. http:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0022354915506242","journal-title":"J Pharm Sci"},{"issue":"1","key":"1336_CR28","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1089\/dia.2005.7.131","volume":"7","author":"PM Wang","year":"2005","unstructured":"Wang PM, Cornwell M, Prausnitz MR. Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles. Diabetes Technol Ther. 2005;7(1):131\u201341. https:\/\/doi.org\/10.1089\/dia.2005.7.131 .","journal-title":"Diabetes Technol Ther"},{"issue":"6","key":"1336_CR29","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1089\/dia.2011.0255","volume":"14","author":"K Sakaguchi","year":"2012","unstructured":"Sakaguchi K, Hirota Y, Hashimoto N, Ogawa W, Sato T, Okada S, et al. A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology: evaluation of the accuracy and usefulness with oral glucose tolerance tests in subjects with and without diabetes. Diabetes Technol Ther. 2012;14(6):485\u201391. https:\/\/doi.org\/10.1089\/dia.2011.0255 .","journal-title":"Diabetes Technol Ther"},{"key":"1336_CR30","doi-asserted-by":"crossref","unstructured":"Donnelly RF, Mooney K, Caffarel-Salvador E, Torrisi BM, Eltayib E, McElnay JC. Microneedle-mediated minimally invasive patient monitoring. Ther Drug Monit. 2013; http:\/\/content.wkhealth.com\/linkback\/openurl?sid=WKPTLP:landingpage&an=00007691-900000000-99442","DOI":"10.1097\/FTD.0000000000000022"},{"issue":"21","key":"1336_CR31","doi-asserted-by":"publisher","first-page":"10520","DOI":"10.1021\/ac503823p","volume":"86","author":"AV Romanyuk","year":"2014","unstructured":"Romanyuk AV, Zvezdin VN, Samant P, Grenader MI, Zemlyanova M, Prausnitz MR. Collection of analytes from microneedle patches. Anal Chem. 2014;86(21):10520\u20133. https:\/\/doi.org\/10.1021\/ac503823p .","journal-title":"Anal Chem"},{"key":"1336_CR32","doi-asserted-by":"crossref","unstructured":"Caffarel-Salvador E, Brady AJ, Eltayib E, Meng T, Alonso-Vicente A, Gonzalez-Vazquez P, et al. Hydrogel-forming microneedle arrays allow detection of drugs and glucose in vivo: potential for use in diagnosis and therapeutic drug monitoring. Chan C, editor. PLoS One. 2015;10(12):e0145644. Available from: http:\/\/journals.plos.org\/plosone\/article\/file?id=10.1371\/journal.pone.0145644&type=printable","DOI":"10.1371\/journal.pone.0145644"},{"issue":"37","key":"1336_CR33","doi-asserted-by":"publisher","first-page":"1702243","DOI":"10.1002\/adma.201702243","volume":"29","author":"H Chang","year":"2017","unstructured":"Chang H, Zheng M, Yu X, Than A, Seeni RZ, Kang R, et al. A swellable microneedle patch to rapidly extract skin interstitial fluid for timely metabolic analysis. Adv Mater. 2017;29(37):1702243. https:\/\/doi.org\/10.1002\/adma.201702243 .","journal-title":"Adv Mater"},{"issue":"4","key":"1336_CR34","doi-asserted-by":"publisher","first-page":"43","DOI":"10.3390\/pharmaceutics9040043","volume":"9","author":"T Kiang","year":"2017","unstructured":"Kiang T, Ranamukhaarachchi S, Ensom M. Revolutionizing therapeutic drug monitoring with the use of interstitial fluid and microneedles technology. Pharmaceutics. 2017;9(4):43. http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/29019915","journal-title":"Pharmaceutics"},{"key":"1336_CR35","doi-asserted-by":"crossref","unstructured":"Zimmermann S, Fienbork D, Stoeber B, Flounders AW, Liepmann D. A microneedle-based glucose monitor: fabricated on a wafer-level using in-device enzyme immobilization. In: TRANSDUCERS\u201903 12th International Conference on Solid-State Sensors, Actuators and Microsystems Digest of Technical Papers (Cat No03TH8664). IEEE;. p. 99\u2013102. http:\/\/ieeexplore.ieee.org\/document\/1215262\/","DOI":"10.1109\/SENSOR.2003.1215262"},{"key":"1336_CR36","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/S0925-4005(03)00552-5","volume":"99","author":"S Zimmermann","year":"2004","unstructured":"Zimmermann S, Fienbork D, Flounders AW, Liepmann D. In-device enzyme immobilization: wafer-level fabrication of an integrated glucose sensor. Sensors Actuators B. 2004;99:163\u201373. Available from: https:\/\/ac.els-cdn.com\/S0925400503005525\/1-s2.0-S0925400503005525-main.pdf?_tid=020881da-3da9-4b06-84bf-c64ada008838&acdnat=1533673088_35e97cd3db5f6bd17c320720a55d18b0","journal-title":"Sensors Actuators B"},{"key":"1336_CR37","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.sna.2003.11.008","volume":"114","author":"EV Mukerjee","year":"2004","unstructured":"Mukerjee EV, Collins SD, Isseroff RR, Smith RL. Microneedle array for transdermal biological fluid extraction and in situ analysis. Sensors Actuators A. 2004;114:267\u201375. Available from: https:\/\/ac.els-cdn.com\/S0924424703006381\/1-s2.0-S0924424703006381-main.pdf?_tid=516bf37c-6980-4149-88a5-63fb8c136f85&acdnat=1533668749_77d67ae1d55cee1ddb39130ed33ed624","journal-title":"Sensors Actuators A"},{"key":"1336_CR38","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/j.bios.2014.11.010","volume":"66","author":"L.M. Strambini","year":"2015","unstructured":"Strambini LM, Longo A, Scarano S, Prescimone T, Palchetti I, Minunni M, et al. Self-powered microneedle-based biosensors for pain-free high-accuracy measurement of glycaemia in interstitial fluid. 2014; Available from: https:\/\/doi.org\/10.1016\/j.bios.2014.11.010","journal-title":"Biosensors and Bioelectronics"},{"issue":"29","key":"1336_CR39","doi-asserted-by":"publisher","first-page":"8427","DOI":"10.1007\/s00216-016-9961-6","volume":"408","author":"S Sharma","year":"2016","unstructured":"Sharma S, Huang Z, Rogers M, Boutelle M, Cass AEG. Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring. Anal Bioanal Chem. 2016;408(29):8427\u201335. https:\/\/doi.org\/10.1007\/s00216-016-9961-6 .","journal-title":"Anal Bioanal Chem"},{"issue":"3","key":"1336_CR40","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1177\/1932296814526191","volume":"8","author":"A Jina","year":"2014","unstructured":"Jina A, Tierney MJ, Tamada JA, McGill S, Desai S, Chua B, et al. Design, development, and evaluation of a novel microneedle array-based continuous glucose monitor. J Diabetes Sci Technol. 2014;8(3):483\u20137. Available from: http:\/\/www.pubmedcentral.nih.gov\/articlerender.fcgi?artid=4455438&tool=pmcentrez&rendertype=abstract","journal-title":"J Diabetes Sci Technol."},{"key":"1336_CR41","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1016\/j.sna.2013.09.026","volume":"203","author":"B Chua","year":"2013","unstructured":"Chua B, Desai SP, Tierney MJ, Tamada JA, Jina AN. Effect of microneedles shape on skin penetration and minimally invasive continuous glucose monitoring in vivo. Sensors Actuators A Phys. 2013;203:373\u201381. https:\/\/doi.org\/10.1016\/j.sna.2013.09.026 .","journal-title":"Sensors Actuators A Phys"},{"issue":"1","key":"1336_CR42","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.ab.2008.08.018","volume":"383","author":"H Lam","year":"2008","unstructured":"Lam H, Kostov Y, Rao G, Tolosa L. Low-cost optical lifetime assisted ratiometric glutamine sensor based on glutamine binding protein. Anal Biochem. 2008;383(1):61\u20137.","journal-title":"Anal Biochem"},{"issue":"10","key":"1336_CR43","doi-asserted-by":"publisher","first-page":"1602","DOI":"10.1023\/A:1018916907263","volume":"16","author":"VK Gupta","year":"1999","unstructured":"Gupta VK, Zatz JL, Rerek M. Percutaneous absorption of sunscreens through micro-Yucatan pig skin in vitro. Pharm Res. 1999;16(10):1602\u20137. https:\/\/doi.org\/10.1023\/A:1018916907263 .","journal-title":"Pharm Res"},{"key":"1336_CR44","unstructured":"Milewski M. Microneedle-assisted transdermal delivery of naltrexone species: in vitro permeation and in vivo pharmacokinetics studies. Vol. 160. University of Kentucky Doctoral Dissertations; 2011. Available from: https:\/\/uknowledge.uky.edu\/gradschool_diss\/160"},{"key":"1336_CR45","unstructured":"Tiangco C, Fon D, Sardesai N, Kostov Y, Sevilla F, Rao G, et al. A fiber optic biosensor for umolar levels of glucose less figures. Sensors Actuators. 2015;"},{"key":"1336_CR46","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.jconrel.2017.05.029","volume":"260","author":"S Bhatnagar","year":"2017","unstructured":"Bhatnagar S, Dave K, Venuganti VVK. Microneedles in the clinic. J Control Release. 2017;260:164\u201382. Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S016836591730603X","journal-title":"J Control Release"},{"issue":"8","key":"1336_CR47","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1111\/exd.12723","volume":"24","author":"MTC McCrudden","year":"2015","unstructured":"McCrudden MTC, McAlister E, Courtenay AJ, Gonz\u00e1lez-V\u00e1zquez P, Raj Singh TR, Donnelly RF. Microneedle applications in improving skin appearance. Exp Dermatol. 2015;24(8):561\u20136. https:\/\/doi.org\/10.1111\/exd.12723 .","journal-title":"Exp Dermatol"}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00216-018-1336-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-018-1336-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-018-1336-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,6]],"date-time":"2025-07-06T18:34:19Z","timestamp":1751826859000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00216-018-1336-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,31]]},"references-count":47,"journal-issue":{"issue":"27","published-print":{"date-parts":[[2018,11]]}},"alternative-id":["1336"],"URL":"https:\/\/doi.org\/10.1007\/s00216-018-1336-8","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8,31]]},"assertion":[{"value":"15 June 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 August 2018","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 August 2018","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2018","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no conflict of interest. Yucatan minipig skin was purchased from Sinclair BioResources who comply with multiple agencies and are a USDA licensed breeder (43-A-5793). The company is in full compliance with the Animal Welfare Act and has maintained accreditation by the Association for Assessment and Accreditation of Laboratory Animal Care International (AAALAC International) since 1995.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The studies on human subjects were conducted in accordance with the Declaration of Helsinki, and the protocol was approved by the Office of Research Protections and Compliance of UMBC (Protocol Y17LT05060) on November 9, 2016.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}}]}}