{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T02:36:09Z","timestamp":1768790169609,"version":"3.49.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"24","license":[{"start":{"date-parts":[[2019,4,23]],"date-time":"2019-04-23T00:00:00Z","timestamp":1555977600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000857","name":"Loughborough University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100000857","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2019,9]]},"DOI":"10.1007\/s00216-019-01790-6","type":"journal-article","created":{"date-parts":[[2019,4,23]],"date-time":"2019-04-23T03:48:39Z","timestamp":1555991319000},"page":"6309-6317","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Combined hydrophilic interaction liquid chromatography-scanning field asymmetric waveform ion mobility spectrometry-time-of-flight mass spectrometry for untargeted metabolomics"],"prefix":"10.1007","volume":"411","author":[{"given":"Katarzyna M.","family":"Szyku\u0142a","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joris","family":"Meurs","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew A.","family":"Turner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Colin S.","family":"Creaser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James C.","family":"Reynolds","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,4,23]]},"reference":[{"key":"1790_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.chroma.2014.11.050","volume":"1374","author":"P Yin","year":"2014","unstructured":"Yin P, Xu G. Current state-of-the-art of nontargeted metabolomics based on liquid chromatography-mass spectrometry with special emphasis in clinical applications. J Chromatogr A. 2014;1374:1\u201313.","journal-title":"J Chromatogr A"},{"key":"1790_CR2","doi-asserted-by":"publisher","first-page":"4184","DOI":"10.1021\/ac503775m","volume":"87","author":"PA Vorkas","year":"2015","unstructured":"Vorkas PA, Isaac G, Anwar MA, Davies AH, Want EJ, Nicholson JK, et al. Untargeted UPLC-MS profiling pipeline to expand tissue metabolome coverage: application to cardiovascular disease. Anal Chem. 2015;87:4184\u201393.","journal-title":"Anal Chem"},{"key":"1790_CR3","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.aca.2016.12.029","volume":"955","author":"Y Gagnebin","year":"2017","unstructured":"Gagnebin Y, Tonoli D, Lescuyer P, Ponte B, de Seigneux S, Martin PY, et al. Metabolomic analysis of urine samples by UHPLC-QTOF-MS: impact of normalization strategies. Anal Chim Acta. 2017;955:27\u201335.","journal-title":"Anal Chim Acta"},{"key":"1790_CR4","doi-asserted-by":"publisher","first-page":"1897","DOI":"10.1007\/s13361-016-1469-y","volume":"27","author":"AC Schrimpe-Rutledge","year":"2016","unstructured":"Schrimpe-Rutledge AC, Codreanu SG, Sherrod SD, McLean JA. Untargeted metabolomics strategies\u2014challenges and emerging directions. J Am Soc Mass Spectrom. 2016;27:1897\u2013905.","journal-title":"J Am Soc Mass Spectrom"},{"key":"1790_CR5","volume-title":"Ion mobility spectrometry","author":"GA Eiceman","year":"2016","unstructured":"Eiceman GA, Karpas Z, Hill HH. Ion mobility spectrometry. 3rd ed. Boca Raton: CRC Press; 2016.","edition":"3"},{"key":"1790_CR6","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.ijms.2010.02.007","volume":"298","author":"P Dwivedi","year":"2010","unstructured":"Dwivedi P, Schultz AJ Jr, Hill HH. Metabolic profiling of human blood by high-resolution ion mobility mass spectrometry (IM-MS). Int J Mass Spectrom. 2010;298:78\u201390.","journal-title":"Int J Mass Spectrom"},{"key":"1790_CR7","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.jchromb.2008.04.043","volume":"871","author":"EL Harry","year":"2008","unstructured":"Harry EL, Weston DJ, Bristow AWT, Wilson IA, Creaser CS. An approach to enhancing coverage of the urinary metabonome using liquid chromatography-ion mobility-mass spectrometry. J Chromatogr B. 2008;871:357\u201361.","journal-title":"J Chromatogr B"},{"key":"1790_CR8","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1007\/s11306-013-0541-x","volume":"9","author":"A Malkar","year":"2013","unstructured":"Malkar A, Devenport NA, Martin HJ, Patel P, Turner MA, Watson P, et al. Metabolic profiling of human saliva before and after induced physiological stress by ultra-high performance liquid chromatography\u2013ion mobility\u2013mass spectrometry. Metabolomics. 2013;9:1192\u2013201.","journal-title":"Metabolomics."},{"key":"1790_CR9","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/0168-1176(93)87062-W","volume":"128","author":"IA Buryakov","year":"1993","unstructured":"Buryakov IA, Krylov EV, Nazarov EG, Rasulev UK. A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric field. Int J Mass Spectrom Ion Process. 1993;128:143\u20138.","journal-title":"Int J Mass Spectrom Ion Process"},{"key":"1790_CR10","doi-asserted-by":"publisher","DOI":"10.1201\/9781420051070","volume-title":"Differential ion mobility spectrometry: nonlinear ion transport and fundamentals of FAIMS","author":"AA Shvartsburg","year":"2008","unstructured":"Shvartsburg AA. Differential ion mobility spectrometry: nonlinear ion transport and fundamentals of FAIMS. Boca Raton: CRC Press; 2008."},{"key":"1790_CR11","doi-asserted-by":"publisher","first-page":"2346","DOI":"10.1021\/ac981380y","volume":"71","author":"RW Purves","year":"1999","unstructured":"Purves RW, Guevremont R. Electrospray ionization high-field asymmetric waveform ion mobility spectrometry-mass spectrometry. Anal Chem. 1999;71:2346\u201357.","journal-title":"Anal Chem"},{"key":"1790_CR12","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1586\/epr.12.50","volume":"9","author":"KE Swearingen","year":"2012","unstructured":"Swearingen KE, Moritz RL. High-field asymmetric waveform ion mobility spectrometry for mass spectrometry-based proteomics. Expert Rev Proteomics. 2012;9:505\u201317.","journal-title":"Expert Rev Proteomics"},{"key":"1790_CR13","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1093\/jat\/25.2.81","volume":"25","author":"MA McCooeye","year":"2001","unstructured":"McCooeye MA, Ells B, Barnett DA, Purves RW, Guevremont R. Quantitation of morphine and codeine in human urine using high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometric detection. J Anal Toxicol. 2001;25:81\u20137.","journal-title":"J Anal Toxicol"},{"key":"1790_CR14","doi-asserted-by":"publisher","first-page":"2555","DOI":"10.1007\/s00216-011-5444-y","volume":"402","author":"E Varesio","year":"2012","unstructured":"Varesio E, Le Blanc JCY, Hopfgartner G. Real-time 2D separation by LC \u00d7 differential ion mobility hyphenated to mass spectrometry. Anal Bioanal Chem. 2012;402:2555\u201364.","journal-title":"Anal Bioanal Chem"},{"key":"1790_CR15","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.chroma.2012.12.065","volume":"1278","author":"RW Smith","year":"2013","unstructured":"Smith RW, Toutoungi DE, Reynolds JC, Bristow AWT, Ray A, Sage A, et al. Enhanced performance in the determination of ibuprofen 1-\u03b2-O-acyl glucuronide in urine by combining high field asymmetric waveform ion mobility spectrometry with liquid chromatography-time-of-flight mass spectrometry. J Chromatogr A. 2013;1278:76\u201381.","journal-title":"J Chromatogr A"},{"key":"1790_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.aca.2016.09.027","volume":"946","author":"PS Chen","year":"2016","unstructured":"Chen PS, Chen SH, Chen JH, Haung WY, Liu HT, Kong PH, et al. Modifier-assisted differential mobility\u2013tandem mass spectrometry method for detection and quantification of amphetamine-type stimulants in urine. Anal Chim Acta. 2016;946:1\u20138.","journal-title":"Anal Chim Acta"},{"key":"1790_CR17","doi-asserted-by":"publisher","first-page":"7431","DOI":"10.1021\/acs.analchem.7b00940","volume":"89","author":"KL Arthur","year":"2017","unstructured":"Arthur KL, Turner MA, Brailsford AD, Kicman AT, Cowan DA, Reynolds JC, et al. Rapid analysis of anabolic steroid metabolites in urine by combining field asymmetric waveform ion mobility spectrometry with liquid chromatography and mass spectrometry. Anal Chem. 2017;89:7431\u20137.","journal-title":"Anal Chem"},{"key":"1790_CR18","doi-asserted-by":"publisher","first-page":"1626","DOI":"10.1007\/s13361-016-1438-5","volume":"27","author":"Z Chen","year":"2016","unstructured":"Chen Z, Coy SL, Pannkuk EL, Laiakis EC, Hall AB, Fornace AJ Jr, et al. Rapid and high-throughput detection and quantitation of radiation biomarkers in human and nonhuman primates by differential mobility spectrometry-mass spectrometry. J Am Soc Mass Spectrom. 2016;27:1626\u201336.","journal-title":"J Am Soc Mass Spectrom"},{"key":"1790_CR19","doi-asserted-by":"publisher","first-page":"1650","DOI":"10.1007\/s13361-018-1977-z","volume":"29","author":"Z Chen","year":"2018","unstructured":"Chen Z, Coy SL, Pannkuk EL, Laiakis EC, Fornace AJ Jr, Vuoros P. Differential mobility spectrometry-mass spectrometry (DMS-MS) in radiation biodosimetry: rapid and high-throughput quantitation of multiple radiation biomarkers in nonhuman primate urine. J Am Soc Mass Spectrom. 2018;29:1650\u201364.","journal-title":"J Am Soc Mass Spectrom"},{"key":"1790_CR20","doi-asserted-by":"publisher","unstructured":"Arthur KL, Wilson LS, Turner MA, Lindley MR, Reynolds JC, Creaser CS. The determination of salivary oxipurines before and after exercise by combined liquid chromatography-field asymmetric waveform ion mobility spectrometry-time-of-flight mass spectrometry. Int J Ion Mobil Spectrom. 2018. https:\/\/doi.org\/10.1007\/s12127-018-0232-4 .","DOI":"10.1007\/s12127-018-0232-4"},{"key":"1790_CR21","doi-asserted-by":"publisher","first-page":"11771","DOI":"10.1021\/ac4020353","volume":"85","author":"T Porta","year":"2013","unstructured":"Porta T, Varesio E, Hopfgartner G. Gas-phase separation of drugs and metabolites using modifier-assisted differential ion mobility spectrometry hyphenated to liquid extraction surface analysis and mass spectrometry. Anal Chem. 2013;85:11771\u20139.","journal-title":"Anal Chem"},{"key":"1790_CR22","doi-asserted-by":"publisher","first-page":"9107","DOI":"10.1021\/ac202044h","volume":"83","author":"DG Beach","year":"2011","unstructured":"Beach DG, Gabryelski W. Nontarget analysis of urine by electrospray ionization-high field asymmetric waveform ion mobility-tandem mass spectrometry. Anal Chem. 2011;83:9107\u201313.","journal-title":"Anal Chem"},{"key":"1790_CR23","doi-asserted-by":"publisher","first-page":"2127","DOI":"10.1021\/ac3027542","volume":"85","author":"DG Beach","year":"2013","unstructured":"Beach DG, Gabryelski W. Linear and nonlinear regimes of electrospray signal response in analysis of urine by ESI-FAIMS-MS and implications for nontarget quantification. Anal Chem. 2013;85:2127\u201334.","journal-title":"Anal Chem"},{"key":"1790_CR24","unstructured":"Harry E. The development of ion mobility-mass spectrometry for complex mixture analysis. Loughborough University PhD thesis. 2011. https:\/\/dspace.lboro.ac.uk\/2134\/9119 . Accessed 6 Sept 2018."},{"key":"1790_CR25","doi-asserted-by":"publisher","first-page":"3452","DOI":"10.1021\/acs.analchem.6b04315","volume":"89","author":"KL Arthur","year":"2017","unstructured":"Arthur KL, Turner MA, Reynolds JC, Creaser CS. Increasing peak capacity in non-targeted omics applications by combining full scan field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry. Anal Chem. 2017;89:3452\u20139.","journal-title":"Anal Chem"},{"key":"1790_CR26","doi-asserted-by":"publisher","first-page":"2865","DOI":"10.1007\/s00216-018-0978-x","volume":"410","author":"S Wernisch","year":"2018","unstructured":"Wernisch S, Afshinnia F, Rajendiran T, Pennathur S. Probing the application range and selectivity of a differential mobility spectrometry\u2013mass spectrometry platform for metabolomics. Anal Bioanal Chem. 2018;410:2865\u201377.","journal-title":"Anal Bioanal Chem"},{"key":"1790_CR27","doi-asserted-by":"publisher","unstructured":"Gabelica V, Shvartsburg AA, Afonso C, Barran P, Benesch JLP, et al. Recommendations for reporting ion mobility mass spectrometry measurements. Mass Spectrom Rev. 2019. https:\/\/doi.org\/10.1002\/mas.21585 .","DOI":"10.1002\/mas.21585"},{"key":"1790_CR28","doi-asserted-by":"publisher","first-page":"2534","DOI":"10.1093\/bioinformatics\/btn323","volume":"24","author":"D Kessner","year":"2008","unstructured":"Kessner D, Chambers M, Burke R, Agus D, Mallick P. ProteoWizard: open source software for rapid proteomics tools development. Bioinformatics. 2008;24:2534\u20136.","journal-title":"Bioinformatics"},{"key":"1790_CR29","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1111\/j.2517-6161.1995.tb02031.x","volume":"57","author":"YB Hochberg","year":"1995","unstructured":"Hochberg YB, Benjamini Y. Controlling the false discovery rate: a practical and powerful approach to multiple testing. J R Stat Soc Ser B. 1995;57:289\u2013300.","journal-title":"J R Stat Soc Ser B"},{"key":"1790_CR30","doi-asserted-by":"publisher","first-page":"5407","DOI":"10.1039\/C6AY00938G","volume":"8","author":"A Malkar","year":"2016","unstructured":"Malkar A, Wilson E, Harrrison T, Shaw D, Creaser CS. Untargeted metabolic profiling of saliva by liquid chromatography-mass spectrometry for the identification of potential diagnostic biomarkers of asthma. Anal Methods. 2016;8:5407\u201313.","journal-title":"Anal Methods"},{"key":"1790_CR31","doi-asserted-by":"publisher","first-page":"4095","DOI":"10.1021\/ac300212r","volume":"84","author":"LJ Brown","year":"2012","unstructured":"Brown LJ, Smith RW, Toutoungi DE, Reynolds JC, Bristow AWT, Ray A, et al. Enhanced analyte detection using in-source fragmentation of field asymmetric waveform ion mobility spectrometry-selected ions in combination with time-of-flight mass spectrometry. Anal Chem. 2012;84:4095\u2013103.","journal-title":"Anal Chem"},{"key":"1790_CR32","doi-asserted-by":"publisher","first-page":"6429","DOI":"10.1021\/ac300829f","volume":"84","author":"A Roux","year":"2012","unstructured":"Roux A, Xu Y, Heilier JF, Olivier M-F, Ezan E, Tabet J-C, et al. Annotation of the human adult urinary metabolome and metabolite identification using ultra high performance liquid chromatography coupled to a linear quadrupole ion trap-orbitrap mass spectrometer. Anal Chem. 2012;84:6429\u201337.","journal-title":"Anal Chem"},{"key":"1790_CR33","unstructured":"Human Metabolome Database. http:\/\/www.hmdb.ca\/ . Accessed 24 Jul 2017."}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-019-01790-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00216-019-01790-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-019-01790-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T04:42:38Z","timestamp":1721191358000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00216-019-01790-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4,23]]},"references-count":33,"journal-issue":{"issue":"24","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["1790"],"URL":"https:\/\/doi.org\/10.1007\/s00216-019-01790-6","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4,23]]},"assertion":[{"value":"3 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 March 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 April 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ethical approval for this study was granted by Loughborough University Ethics Approval Committee (human participants). All participants completed a healthscreen questionnaire and then gave informed consent before donating a urine sample. Samples were anonymised and then pooled to give the pooled urine sample used in this study. All experiments were done in accordance with the WMA Declaration of Helsinki, June 1964.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}