{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T04:00:22Z","timestamp":1788321622745,"version":"build-2803163510"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2022,3,2]],"date-time":"2022-03-02T00:00:00Z","timestamp":1646179200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,3,2]],"date-time":"2022-03-02T00:00:00Z","timestamp":1646179200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2022,5]]},"DOI":"10.1007\/s00216-022-03984-x","type":"journal-article","created":{"date-parts":[[2022,3,2]],"date-time":"2022-03-02T05:03:23Z","timestamp":1646197403000},"page":"3541-3549","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["An automated magnetic bead extraction method for measuring plasma metanephrines and 3-methoxytyramine using liquid chromatography tandem mass spectrometry"],"prefix":"10.1007","volume":"414","author":[{"given":"Songlin","family":"Yu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiyan","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jialei","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shenyan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xu","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huanhong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoli","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yutong","family":"Zou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danchen","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shaowei","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiuzhi","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,3,2]]},"reference":[{"key":"3984_CR1","doi-asserted-by":"crossref","unstructured":"Shi J, Dhaliwal P, Zheng Y Zi, Straseski JA, Cervinski MA, Shajani-Yi Z, et al. An intact ACTH LC-MS\/MS assay as an arbiter of clinically discordant immunoassay results. Clin Chem. 2019; 10.1373\/clinchem.2019.306365","DOI":"10.1373\/clinchem.2019.306365"},{"key":"3984_CR2","doi-asserted-by":"publisher","DOI":"10.1258\/000456307779595896","author":"J Kane","year":"2007","unstructured":"Kane J, Middle J, Cawood M. Measurement of serum testosterone in women; what should we do? Ann Clin Biochem. 2007. https:\/\/doi.org\/10.1258\/000456307779595896.","journal-title":"Ann Clin Biochem."},{"key":"3984_CR3","doi-asserted-by":"publisher","DOI":"10.1373\/clinchem.2014.233551","author":"MJ Wright","year":"2015","unstructured":"Wright MJ, Thomas RL, Stanford PE, Horvath AR. Multiple reaction monitoring with multistage fragmentation (MRM3) detection enhances selectivity for LC-MS\/MS analysis of plasma free metanephrines. Clin Chem. 2015. https:\/\/doi.org\/10.1373\/clinchem.2014.233551.","journal-title":"Clin Chem."},{"key":"3984_CR4","doi-asserted-by":"publisher","unstructured":"Lagerstedt SA, O'Kane DJ, Singh RJ. Measurement of plasma free metanephrine and normetanephrine by liquid chromatography-tandem mass spectrometry for diagnosis of pheochromocytoma. Clin Chem. 2004;https:\/\/ doi:https:\/\/doi.org\/10.1373\/clinchem.2003.024703","DOI":"10.1373\/clinchem.2003.024703"},{"key":"3984_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpba.2019.113018","author":"D Virag","year":"2020","unstructured":"Virag D, Kiraly M, Drahos L, Edes AE, Gecse K, Bagdy G, et al. Development, validation and application of LC-MS\/MS method for quantification of amino acids, kynurenine and serotonin in human plasma. J Pharm Biomed Anal. 2020. https:\/\/doi.org\/10.1016\/j.jpba.2019.113018.","journal-title":"J Pharm Biomed Anal."},{"key":"3984_CR6","doi-asserted-by":"publisher","DOI":"10.1210\/jc.2014-1498","author":"JW Lenders","year":"2014","unstructured":"Lenders JW, Duh QY, Eisenhofer G, Gimenez-Roqueplo AP, Grebe SK, Murad MH, et al. Pheochromocytoma and paraganglioma: an endocrine society clinical practice guideline. J Clin Endocrinol Metab. 2014. https:\/\/doi.org\/10.1210\/jc.2014-1498.","journal-title":"J Clin Endocrinol Metab."},{"key":"3984_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsbmb.2010.05.001","author":"FZ Stanczyk","year":"2010","unstructured":"Stanczyk FZ, Clarke NJ. Advantages and challenges of mass spectrometry assays for steroid hormones. J Steroid Biochem Mol Biol. 2010. https:\/\/doi.org\/10.1016\/j.jsbmb.2010.05.001.","journal-title":"J Steroid Biochem Mol Biol."},{"key":"3984_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem.2010.06.005","author":"M Vogeser","year":"2011","unstructured":"Vogeser M, Kirchhoff F. Progress in automation of LC-MS in laboratory medicine. Clin Biochem. 2011. https:\/\/doi.org\/10.1016\/j.clinbiochem.2010.06.005.","journal-title":"Clin Biochem."},{"key":"3984_CR9","doi-asserted-by":"publisher","unstructured":"van Faassen M, Bischoff R, Eijkelenkamp K, de Jong WHA, van der Ley CP, Kema IP. In matrix derivatization combined with LC-MS\/MS results in ultrasensitive quantification of plasma free metanephrines and catecholamines. Anal Chem. 2020. doi:https:\/\/doi.org\/10.1021\/acs.analchem.0c01263","DOI":"10.1021\/acs.analchem.0c01263"},{"key":"3984_CR10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchromb.2019.121805","volume":"1129","author":"S Yu","year":"2019","unstructured":"Yu S, Yin Y, Li Q, Yu J, Liu W, Wang D, et al. Validation of an improved liquid chromatography tandem mass spectrometry method for rapid and simultaneous analysis of plasma catecholamine and their metabolites. J Chromatogr B Analyt Technol Biomed Life Sci. 2019;1129: 121805. https:\/\/doi.org\/10.1016\/j.jchromb.2019.121805.","journal-title":"J Chromatogr B Analyt Technol Biomed Life Sci."},{"key":"3984_CR11","doi-asserted-by":"publisher","unstructured":"Chen H, Sippel RS, O'Dorisio MS, Vinik AI, Lloyd RV, Pacak K. The North American Neuroendocrine Tumor Society consensus guideline for the diagnosis and management of neuroendocrine tumors: pheochromocytoma, paraganglioma, and medullary thyroid cancer. Pancreas. 2010. https:\/\/doi.org\/10.1097\/MPA.0b013e3181ebb4f0","DOI":"10.1097\/MPA.0b013e3181ebb4f0"},{"key":"3984_CR12","unstructured":"Wayne P (2014) Liquid chromatography-mass spectrometry methods; Approved Guidelines. CLSI. Clinical and Laboratory Standards Institute;CLSI document C62-A."},{"key":"3984_CR13","doi-asserted-by":"publisher","unstructured":"Peitzsch M, Prejbisz A, Kroiss M, Beuschlein F, Arlt W, Januszewicz A, et al. (2013) Analysis of plasma 3-methoxytyramine, normetanephrine, and metanephrine by ultraperformance liquid chromatography-tandem mass spectrometry: utility for diagnosis of dopamine-producing metastatic phaeochromocytoma. Ann Clin Biochem. https:\/\/doi.org\/10.1258\/acb.2012.012112","DOI":"10.1258\/acb.2012.012112"},{"key":"3984_CR14","unstructured":"Wayne,CLSI (2005) CLSI document EP15-A2. User verification of performance for precision and trueness ag, 23d, CLSI"},{"key":"3984_CR15","doi-asserted-by":"publisher","unstructured":"Matuszewski BK, Constanzer ML, Chavez-Eng CM (2003) Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS\/MS. Anal Chem. https:\/\/doi.org\/10.1021\/ac020361s","DOI":"10.1021\/ac020361s"},{"key":"3984_CR16","doi-asserted-by":"publisher","unstructured":"Yadav M, Trivedi V, Upadhyay V, Shah G, Baxi GA, Goswami S, et al. Comparison of extraction procedures for assessment of matrix effect for selective and reliable determination of atazanavir in human plasma by LC-ESI-MS\/MS. J Chromatogr B Analyt Technol Biomed Life Sci. https:\/\/doi.org\/10.1016\/j.jchromb.2011.12.031","DOI":"10.1016\/j.jchromb.2011.12.031"},{"key":"3984_CR17","unstructured":"NCCLS (2002) Method comparison and bias estimation using patient samples; Approved Guideline\u2014Second Edition. NCCLS document EP9-A2"},{"key":"3984_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejca.2011.07.016","author":"G Eisenhofer","year":"2012","unstructured":"Eisenhofer G, Lenders JW, Siegert G, Bornstein SR, Friberg P, Milosevic D, et al. Plasma methoxytyramine: a novel biomarker of metastatic pheochromocytoma and paraganglioma in relation to established risk factors of tumour size, location and SDHB mutation status. Eur J Cancer. 2012. https:\/\/doi.org\/10.1016\/j.ejca.2011.07.016.","journal-title":"Eur J Cancer."},{"key":"3984_CR19","doi-asserted-by":"publisher","unstructured":"de Jong WH, Graham KS, van der Molen JC, Links TP, Morris MR, Ross HA, et al. (2007) Plasma free metanephrine measurement using automated online solid-phase extraction HPLC tandem mass spectrometry. Clin Chem. https:\/\/doi.org\/10.1373\/clinchem.2007.087114","DOI":"10.1373\/clinchem.2007.087114"},{"key":"3984_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem.2020.03.004","author":"C Seger","year":"2020","unstructured":"Seger C, Salzmann L. After another decade: LC-MS\/MS became routine in clinical diagnostics. Clin Biochem. 2020. https:\/\/doi.org\/10.1016\/j.clinbiochem.2020.03.004.","journal-title":"Clin Biochem."}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-022-03984-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00216-022-03984-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-022-03984-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,20]],"date-time":"2022-04-20T09:07:53Z","timestamp":1650445673000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00216-022-03984-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,2]]},"references-count":20,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2022,5]]}},"alternative-id":["3984"],"URL":"https:\/\/doi.org\/10.1007\/s00216-022-03984-x","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,2]]},"assertion":[{"value":"3 December 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 February 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the Ethics Committee of Peking Union Medical College & Chinese Academy of Medical Sciences, Peking Union Medical College Hospital (JS-2956)","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Plasma for the method validation and comparison was obtained from that remaining from patient samples in the Department of Laboratory Medicine, Peking Union Medical College Hospital.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Source of biological material"}}]}}