{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T05:49:43Z","timestamp":1784958583034,"version":"3.55.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"22","license":[{"start":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T00:00:00Z","timestamp":1719878400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T00:00:00Z","timestamp":1719878400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100021171","name":"Guangdong Basic and Applied Basic Research Foundation","doi-asserted-by":"crossref","award":["2021A1515220149"],"award-info":[{"award-number":["2021A1515220149"]}],"id":[{"id":"10.13039\/501100021171","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2024,9]]},"DOI":"10.1007\/s00216-024-05415-5","type":"journal-article","created":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T14:03:38Z","timestamp":1719929018000},"page":"4897-4906","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Evaluation and clinical application of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for serum theophylline"],"prefix":"10.1007","volume":"416","author":[{"given":"Yuanyuan","family":"Du","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiaofang","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Zhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiaoxuan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Di","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pengwei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianbing","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xianzhang","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0092-9966","authenticated-orcid":false,"given":"Liqiao","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,7,2]]},"reference":[{"issue":"8","key":"5415_CR1","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1164\/rccm.201302-0388PP","volume":"188","author":"PJ Barnes","year":"2013","unstructured":"Barnes PJ. Theophylline. Am J Respir Crit Care Med. 2013;188(8):901\u20136.","journal-title":"Am J Respir Crit Care Med."},{"issue":"6","key":"5415_CR2","doi-asserted-by":"publisher","first-page":"5884","DOI":"10.3390\/ijms24065884","volume":"24","author":"J Reyes-Garc\u00eda","year":"2023","unstructured":"Reyes-Garc\u00eda J, D\u00edaz-Hern\u00e1ndez V, Carbajal-Garc\u00eda A, Casas-Hern\u00e1ndez MF, Sommer B, Monta\u00f1o LM. Theophylline-induced relaxation is enhanced after testosterone treatment via increased KV1.2 and KV1.5 protein expression in guinea pig tracheal smooth muscle. Int J Mol Sci. 2023;24(6):5884.","journal-title":"Int J Mol Sci."},{"issue":"3","key":"5415_CR3","doi-asserted-by":"publisher","first-page":"725","DOI":"10.3390\/ph3030725","volume":"3","author":"PJ Barnes","year":"2010","unstructured":"Barnes PJ. Theophylline. Pharmaceuticals (Basel). 2010;3(3):725\u201347.","journal-title":"Pharmaceuticals (Basel)."},{"issue":"6","key":"5415_CR4","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1164\/rccm.200210-1142PP","volume":"167","author":"PJ Barnes","year":"2003","unstructured":"Barnes PJ. Theophylline: new perspectives for an old drug. Am J Respir Crit Care Med. 2003;167(6):813\u20138.","journal-title":"Am J Respir Crit Care Med."},{"key":"5415_CR5","doi-asserted-by":"publisher","first-page":"124207","DOI":"10.1016\/j.ijpharm.2024.124207","volume":"658","author":"T Pflieger","year":"2024","unstructured":"Pflieger T, Venkatesh R, Dachtler M, Cooke K, Laufer S, Lunter D. Influence of design parameters on sustained drug release properties of 3D-printed theophylline tablets. Int J Pharm. 2024;658:124207.","journal-title":"Int J Pharm."},{"issue":"4","key":"5415_CR6","doi-asserted-by":"publisher","first-page":"211","DOI":"10.4103\/2229-4708.93388","volume":"2","author":"AR Babu","year":"2011","unstructured":"Babu AR, Thippeswamy B, Vinod AB, Ramakishore EG, Anand S, Senthil D. Determination of theophylline in rabbit plasma by triple quadrupole LC\/MS. Pharm Methods. 2011;2(4):211\u20137.","journal-title":"Pharm Methods."},{"issue":"6","key":"5415_CR7","first-page":"312","volume":"65","author":"FI Al-Jenoobi","year":"2015","unstructured":"Al-Jenoobi FI, Ahad A, Raish M, Al-Mohizea AM, Alam MA. Investigating the potential effect of Commiphora myrrha on the pharmacokinetics of theophylline, a narrow therapeutic index drug. Drug Res (Stuttg). 2015;65(6):312\u20136.","journal-title":"Drug Res (Stuttg)."},{"issue":"12","key":"5415_CR8","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1056\/NEJM197309202891202","volume":"289","author":"PA Mitenko","year":"1973","unstructured":"Mitenko PA, Ogilvie RI. Rational intravenous doses of theophylline. N Engl J Med. 1973;289(12):600\u20133.","journal-title":"N Engl J Med."},{"issue":"7","key":"5415_CR9","doi-asserted-by":"publisher","first-page":"2301","DOI":"10.1007\/s00216-011-5304-9","volume":"401","author":"T Tachi","year":"2011","unstructured":"Tachi T, Hase T, Okamoto Y, Kaji N, Arima T, Matsumoto H, et al. A clinical trial for therapeutic drug monitoring using microchip-based fluorescence polarization immunoassay. Anal Bioanal Chem. 2011;401(7):2301\u20135.","journal-title":"Anal Bioanal Chem."},{"issue":"2","key":"5415_CR10","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1039\/C8LC01105B","volume":"19","author":"K Nishiyama","year":"2019","unstructured":"Nishiyama K, Sugiura K, Kaji N, Tokeshi M, Baba Y. Development of a microdevice for facile analysis of theophylline in whole blood by a cloned enzyme donor immunoassay. Lab Chip. 2019;19(2):233\u201340.","journal-title":"Lab Chip."},{"issue":"1","key":"5415_CR11","first-page":"31","volume":"20","author":"MA Sarkar","year":"1992","unstructured":"Sarkar MA, Hunt C, Guzelian PS, Karnes HT. Characterization of human liver cytochromes P-450 involved in theophylline metabolism. Drug Metab Dispos. 1992;20(1):31\u20137.","journal-title":"Drug Metab Dispos."},{"key":"5415_CR12","unstructured":"ISO 15193. In vitro diagnostic medical devices \u2013 measurement of quantities in samples of biological origin \u2013 requirements for content and presentation of reference measurement procedures. Geneva: International Organization for Standardization; 2009."},{"key":"5415_CR13","unstructured":"ISO 15194. In vitro diagnostic medical devices \u2013 measurement of quantities in samples of biological origin \u2013 requirements for certified reference materials and the content of supporting documentation. Geneva: International Organization for Standardization; 2009."},{"key":"5415_CR14","unstructured":"ISO 15195. Laboratory medicine \u2013 requirements for the competence of calibration laboratories using reference measurement procedures. Geneva: International Organization for Standardization; 2018."},{"issue":"4\u20135","key":"5415_CR15","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.clinbiochem.2008.09.098","volume":"42","author":"M Panteghini","year":"2009","unstructured":"Panteghini M. Traceability as a unique tool to improve standardization in laboratory medicine. Clin Biochem. 2009;42(4\u20135):236\u201340.","journal-title":"Clin Biochem."},{"key":"5415_CR16","unstructured":"Joint Committee for Traceability of Laboratory Medicine. Database of higher order reference materials; measurement methods\/procedures and services. http:\/\/www.bipm.org\/jctlm\/. Accessed Jan 2024."},{"issue":"2","key":"5415_CR17","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/S0378-4347(00)85151-8","volume":"336","author":"M D\u00e9sage","year":"1984","unstructured":"D\u00e9sage M, Soubeyrand J, Soun A, Brazier JL, Georges Y. Automated theophylline assay using gas chromatography and a mass-selective detector. J Chromatogr. 1984;336(2):285\u201391.","journal-title":"J Chromatogr."},{"issue":"8","key":"5415_CR18","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.1093\/clinchem\/40.8.1503","volume":"40","author":"LM Thienpont","year":"1994","unstructured":"Thienpont LM, Van Nieuwenhove B, St\u00f6ckl D, De Leenheer AP. Candidate reference method for determining serum theophylline applied to target-setting in external quality assessment and routine method evaluation. Clin Chem. 1994;40(8):1503\u201311.","journal-title":"Clin Chem."},{"issue":"9\u201310","key":"5415_CR19","first-page":"535","volume":"48","author":"M Kress","year":"2002","unstructured":"Kress M, Meissner D, Kaiser P, Hanke R, Wood WG. The measurement of theophylline in human serum or plasma using gas chromatography and isotope dilution-mass spectrometry (GC-IDMS) taking other substituted xanthines into consideration. Clin Lab. 2002;48(9\u201310):535\u201340.","journal-title":"Clin Lab."},{"issue":"1\u20132","key":"5415_CR20","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.cca.2008.08.023","volume":"398","author":"Y Zhang","year":"2008","unstructured":"Zhang Y, Mehrotra N, Budha NR, Christensen ML, Meibohm B. A tandem mass spectrometry assay for the simultaneous determination of acetaminophen, caffeine, phenytoin, ranitidine, and theophylline in small volume pediatric plasma specimens. Clin Chim Acta. 2008;398(1\u20132):105\u201312.","journal-title":"Clin Chim Acta."},{"key":"5415_CR21","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.jchromb.2012.01.028","volume":"889\u2013890","author":"JW Chae","year":"2012","unstructured":"Chae JW, Kim DH, Lee BY, Kim EJ, Kwon KI. Development and validation of a sensitive LC-MS\/MS method for the simultaneous quantitation of theophylline and its metabolites in rat plasma. J Chromatogr B Analyt Technol Biomed Life Sci. 2012;889\u2013890:44\u20139.","journal-title":"J Chromatogr B Analyt Technol Biomed Life Sci."},{"key":"5415_CR22","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.jpba.2018.09.023","volume":"162","author":"L Han","year":"2019","unstructured":"Han L, Huang X, Zhang L, Zhang Q, Wang J, Lin H, et al. Candidate reference measurement procedure for determination of urea in serum by liquid chromatography-tandem mass spectrometry. J Pharm Biomed Anal. 2019;162:124\u20139.","journal-title":"J Pharm Biomed Anal."},{"issue":"24","key":"5415_CR23","doi-asserted-by":"publisher","first-page":"6257","DOI":"10.1007\/s00216-018-1236-y","volume":"410","author":"X Huang","year":"2018","unstructured":"Huang X, Zhang Q, Zheng S, Wang J, Han L, Lin H, et al. Measurement of human serum unconjugated estriol without derivatization using liquid chromatography-tandem mass spectrometry candidate reference method and compared with two immunoassays. Anal Bioanal Chem. 2018;410(24):6257\u201367.","journal-title":"Anal Bioanal Chem."},{"issue":"19","key":"5415_CR24","doi-asserted-by":"publisher","first-page":"5615","DOI":"10.1007\/s00216-015-8733-z","volume":"407","author":"EM Mineva","year":"2015","unstructured":"Mineva EM, Schleicher RL, Chaudhary-Webb M, Maw KL, Botelho JC, Vesper HW, et al. A candidate reference measurement procedure for quantifying serum concentrations of 25-hydroxyvitamin D\u2083 and 25-hydroxyvitamin D\u2082 using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal Bioanal Chem. 2015;407(19):5615\u201324.","journal-title":"Anal Bioanal Chem."},{"key":"5415_CR25","doi-asserted-by":"publisher","first-page":"116911","DOI":"10.1016\/j.ijms.2022.116911","volume":"482","author":"J Yan","year":"2022","unstructured":"Yan J, Lin H, Xu Y, Yu L, Chen S, Zhang Q, et al. Measurement of serum uric acid by isotope dilution liquid chromatography tandem mass spectrometry: modification of a candidate reference measurement method and its clinical application. Int J Mass Spectrom. 2022;482:116911.","journal-title":"Int J Mass Spectrom."},{"key":"5415_CR26","unstructured":"CLSI. Evaluation of precision of quantitative measurement procedures; Approved guideline \u2013 third edition. CLSI document EP5-A3. Wayne: Clinical and Laboratory Standards Institute; 2014."},{"key":"5415_CR27","unstructured":"CLSI. User verification of performance for precision and trueness; Approved guideline \u2013 second edition. CLSI document EP15-A2. Wayne: Clinical and Laboratory Standards Institute; 2006."},{"key":"5415_CR28","unstructured":"CLSI. Evaluation of linearity of quantitative measurement procedures \u2013 a statistical approach; Approved guideline. CLSI document EP6-A. Wayne: Clinical and Laboratory Standards Institute; 2006."},{"key":"5415_CR29","unstructured":"CLSI. Interference testing in clinical chemistry; Approved guideline \u2013 second edition. CLSI document EP7-A2. Wayne: Clinical and Laboratory Standards Institute; 2005."},{"key":"5415_CR30","unstructured":"CLSI. Evaluation of matrix effects; Approved guideline \u2013 second edition. CLSI document EP14-A2. Wayne: Clinical and Laboratory Standards Institute; 2005."},{"key":"5415_CR31","unstructured":"CLSI. Liquid chromatography-mass spectrometry methods; Approved guideline. CLSI document C62-A. William C: Clinical and Laboratory Standards Institute; 2014."},{"key":"5415_CR32","unstructured":"ISO\/IEC. Guide 98\u20133:2008. Uncertainty of measurement \u2013 Part 3: Guide to the expression of uncertainty in measurement. Geneva: International Organization for Standardization; 2008."},{"key":"5415_CR33","doi-asserted-by":"crossref","unstructured":"Westgard JO. Managing quality vs. measuring uncertainty in the medical laboratory. Clin Chem Lab Med. 2010;48(1):31-40.","DOI":"10.1515\/CCLM.2010.024"},{"key":"5415_CR34","unstructured":"CLSI. Measurement procedure comparison and bias estimation using patient samples; Approved guideline \u2013 third edition. CLSI document EP09-A3. Wayne: Clinical and Laboratory Standards Institute; 2013."},{"key":"5415_CR35","unstructured":"International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). RELA-IFCC external quality assessment scheme for reference laboratories in laboratory medicine. http:\/\/dgkl-rfb.de:81\/. Accessed Jan 2024."},{"key":"5415_CR36","unstructured":"ISO Guide 35. Technical Committee ISO\/TC 334 Reference materials, 2017. ISO Guide 35:2017 Reference Materials \u2013 Guidance for Characterization and Assessment of Homogeneity and Stability, 2022."}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-024-05415-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00216-024-05415-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-024-05415-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,17]],"date-time":"2024-08-17T07:03:23Z","timestamp":1723878203000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00216-024-05415-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,2]]},"references-count":36,"journal-issue":{"issue":"22","published-print":{"date-parts":[[2024,9]]}},"alternative-id":["5415"],"URL":"https:\/\/doi.org\/10.1007\/s00216-024-05415-5","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,2]]},"assertion":[{"value":"20 May 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 June 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The collection of leftover serum samples was approved by the Ethics Committee of the Second Affiliated Hospital of Guangzhou University of Chinese Medicine (ZE2019-149-01).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The ethics committee approved the exemption of informed consent.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}