{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T09:21:09Z","timestamp":1780478469010,"version":"3.54.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2025,2,5]],"date-time":"2025-02-05T00:00:00Z","timestamp":1738713600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,2,5]],"date-time":"2025-02-05T00:00:00Z","timestamp":1738713600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002954","name":"Universit\u00e0 degli Studi di Milano - Bicocca","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002954","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Microsampling, especially dried blood spots (DBS), emerged in recent years as a viable alternative to conventional blood collection since it\u00a0is rapid, simple, minimally invasive, and has\u00a0user-friendly characteristics. Moreover, DBS are able to avoid analyte degradation thanks to their great stability. Due to their versatility, clinical applications with DBS have\u00a0increased, including mass spectrometry\u2013based metabolomics and lipidomics studies. In this work, we evaluated and optimized extraction protocols testing five different extraction solutions to perform metabolomics and lipidomics studies on the same spot considering three commercially available microsampling devices, Capitainer, Whatman, and Telimmune. Parallelly, we also evaluated the\u00a0short-term stability of the three devices at room temperature for\u00a0up to 5\u00a0days. Our results showed that pure methanol was the best compromise to simultaneously extract from the same spot both the\u00a0lipidome and polar metabolome. However, we also propose a two-step protocol combining methanol and water extraction that improves polar metabolite extraction and shows improved reproducibility in Capitainer and Whatman. Short-term stability results highlighted that both polar metabolites and lipids were stable for\u00a0up to 6\u00a0days using the\u00a0Capitainer device, while with Whatman and Telimmune, some significant variations were observed after 3\u00a0days for some classes of metabolites\/lipids, suggesting the need for cold-chain storage when working with these devices.<\/jats:p>","DOI":"10.1007\/s00216-025-05760-z","type":"journal-article","created":{"date-parts":[[2025,2,5]],"date-time":"2025-02-05T06:03:19Z","timestamp":1738735399000},"page":"1791-1805","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Pre-analytic assessment of dried blood and dried plasma spots: integration in mass spectrometry\u2013based metabolomics and lipidomics workflow"],"prefix":"10.1007","volume":"417","author":[{"given":"Eleonora","family":"Bossi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simone","family":"Serrao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierluigi","family":"Reveglia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonietta","family":"Ferrara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marta","family":"Nobile","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elena","family":"Limo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gaetano","family":"Corso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Paglia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,2,5]]},"reference":[{"issue":"7","key":"5760_CR1","first-page":"175","volume":"9","author":"JL Roberts","year":"2022","unstructured":"Roberts JL, Whiley L, Gray N, Gay M, Lawler NG. Advanced microsamples: current applications and considerations for mass spectrometry-based metabolic phenotyping pipelines. Sep. 2022;9(7):175.","journal-title":"Sep"},{"issue":"4","key":"5760_CR2","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1007\/s10544-019-0412-y","volume":"21","author":"BUW Lei","year":"2019","unstructured":"Lei BUW, Prow TW. A review of microsampling techniques and their social impact. Biomed Microdevices. 2019;21(4):81.","journal-title":"Biomed Microdevices"},{"issue":"11","key":"5760_CR3","doi-asserted-by":"publisher","first-page":"277","DOI":"10.3390\/metabo9110277","volume":"9","author":"OP Trifonova","year":"2019","unstructured":"Trifonova OP, Maslov DL, Balashova EE, Lokhov PG. Evaluation of dried blood spot sampling for clinical metabolomics: effects of different papers and sample storage stability. Metabolites. 2019;9(11):277.","journal-title":"Metabolites"},{"issue":"5","key":"5760_CR4","doi-asserted-by":"publisher","first-page":"e23390","DOI":"10.1002\/ajhb.23390","volume":"32","author":"EM Crimmins","year":"2020","unstructured":"Crimmins EM, Zhang YS, Kim JK, Frochen S, Kang H, Shim H, et al. Dried blood spots: effects of less than optimal collection, shipping time, heat, and humidity. Am J Hum Biol. 2020;32(5):e23390.","journal-title":"Am J Hum Biol"},{"issue":"4","key":"5760_CR5","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1039\/b919622f","volume":"135","author":"G Paglia","year":"2010","unstructured":"Paglia G, D\u2019Apolito O, Gelzo M, Dello Russo A, Corso G. Direct analysis of sterols from dried plasma\/blood spots by an atmospheric pressure thermal desorption chemical ionization mass spectrometry (APTDCI-MS) method for a rapid screening of Smith\u2013Lemli\u2013Opitz syndrome. Analyst. 2010;135(4):789.","journal-title":"Analyst"},{"issue":"23","key":"5760_CR6","doi-asserted-by":"publisher","first-page":"3809","DOI":"10.1002\/rcm.3799","volume":"22","author":"G Paglia","year":"2008","unstructured":"Paglia G, D\u2019Apolito O, Corso G. Precursor ion scan profiles of acylcarnitines by atmospheric pressure thermal desorption chemical ionization tandem mass spectrometry. Rapid Commun Mass Spectrom. 2008;22(23):3809\u201315.","journal-title":"Rapid Commun Mass Spectrom"},{"issue":"11","key":"5760_CR7","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.4155\/bio.10.149","volume":"2","author":"G Corso","year":"2010","unstructured":"Corso G, D\u2019Apolito O, Gelzo M, Paglia G, Dello Russo A. A powerful couple in the future of clinical biochemistry: in situ analysis of dried blood spots by ambient mass spectrometry. Bioanalysis. 2010;2(11):1883\u201391.","journal-title":"Bioanalysis"},{"issue":"24","key":"5760_CR8","doi-asserted-by":"publisher","first-page":"7085","DOI":"10.1007\/s00216-022-04221-1","volume":"414","author":"HB Ferreira","year":"2022","unstructured":"Ferreira HB, Guerra IMS, Melo T, Rocha H, Moreira ASP, Paiva A, et al. Dried blood spots in clinical lipidomics: optimization and recent findings. Anal Bioanal Chem. 2022;414(24):7085\u2013101.","journal-title":"Anal Bioanal Chem"},{"issue":"1","key":"5760_CR9","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s00216-022-04399-4","volume":"415","author":"LM Bishop","year":"2023","unstructured":"Bishop LM, Fiehn O. Comprehensive lipidomic profiling by plasma separation cards. Anal Bioanal Chem. 2023;415(1):193\u2013201.","journal-title":"Anal Bioanal Chem"},{"issue":"3","key":"5760_CR10","doi-asserted-by":"publisher","first-page":"82","DOI":"10.3390\/metabo10030082","volume":"10","author":"K Li","year":"2020","unstructured":"Li K, Naviaux JC, Monk JM, Wang L, Naviaux RK. Improved dried blood spot-based metabolomics: a targeted, broad-spectrum, single-injection method. Metabolites. 2020;10(3):82.","journal-title":"Metabolites"},{"issue":"3","key":"5760_CR11","doi-asserted-by":"publisher","first-page":"35","DOI":"10.3390\/metabo7030035","volume":"7","author":"J Drolet","year":"2017","unstructured":"Drolet J, Tolstikov V, Williams B, Greenwood B, Hill C, Vishnudas V, et al. Integrated metabolomics assessment of human dried blood spots and urine strips. Metabolites. 2017;7(3):35.","journal-title":"Metabolites"},{"issue":"22","key":"5760_CR12","doi-asserted-by":"publisher","first-page":"14306","DOI":"10.1021\/acs.analchem.9b02577","volume":"91","author":"EA Palmer","year":"2019","unstructured":"Palmer EA, Cooper HJ, Dunn WB. Investigation of the 12-month stability of dried blood and urine spots applying untargeted UHPLC-MS metabolomic assays. Anal Chem. 2019;91(22):14306\u201313.","journal-title":"Anal Chem"},{"issue":"4","key":"5760_CR13","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1021\/jasms.2c00358","volume":"34","author":"F Ottosson","year":"2023","unstructured":"Ottosson F, Russo F, Abrahamsson A, MacSween N, Courraud J, Nielsen ZK, et al. Effects of long-term storage on the biobanked neonatal dried blood spot metabolome. J Am Soc Mass Spectrom. 2023;34(4):685\u201394.","journal-title":"J Am Soc Mass Spectrom"},{"issue":"1","key":"5760_CR14","doi-asserted-by":"publisher","first-page":"46","DOI":"10.3390\/metabo14010046","volume":"14","author":"E Bossi","year":"2024","unstructured":"Bossi E, Limo E, Pagani L, Monza N, Serrao S, Denti V, et al. Revolutionizing blood collection: innovations, applications, and the potential of microsampling technologies for monitoring metabolites and lipids. Metabolites. 2024;14(1):46.","journal-title":"Metabolites"},{"issue":"D1","key":"5760_CR15","doi-asserted-by":"publisher","first-page":"D608","DOI":"10.1093\/nar\/gkx1089","volume":"46","author":"DS Wishart","year":"2018","unstructured":"Wishart DS, Feunang YD, Marcu A, Guo AC, Liang K, V\u00e1zquez-Fresno R, et al. HMDB 4.0: the Human Metabolome Database for 2018. Nucleic Acids Res. 2018;46(D1):D608-17.","journal-title":"Nucleic Acids Res"},{"issue":"5","key":"5760_CR16","doi-asserted-by":"publisher","first-page":"3156","DOI":"10.1021\/acs.analchem.7b04424","volume":"90","author":"C Guijas","year":"2018","unstructured":"Guijas C, Montenegro-Burke JR, Domingo-Almenara X, Palermo A, Warth B, Hermann G, et al. METLIN: a technology platform for identifying knowns and unknowns. Anal Chem. 2018;90(5):3156\u201364.","journal-title":"Anal Chem"},{"issue":"W1","key":"5760_CR17","doi-asserted-by":"publisher","first-page":"W398","DOI":"10.1093\/nar\/gkae253","volume":"52","author":"Z Pang","year":"2024","unstructured":"Pang Z, Lu Y, Zhou G, Hui F, Xu L, Viau C, et al. MetaboAnalyst 6.0: towards a unified platform for metabolomics data processing, analysis and interpretation. Nucleic Acids Res. 2024;52(W1):W398-406.","journal-title":"Nucleic Acids Res"},{"issue":"3","key":"5760_CR18","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1007\/s11306-007-0082-2","volume":"3","author":"LW Sumner","year":"2007","unstructured":"Sumner LW, Amberg A, Barrett D, Beale MH, Beger R, Daykin CA, et al. Proposed minimum reporting standards for chemical analysis. Metabolomics. 2007;3(3):211\u201321.","journal-title":"Metabolomics"},{"issue":"5","key":"5760_CR19","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1002\/bimj.201000030","volume":"52","author":"A Albert","year":"2010","unstructured":"Albert A, Zhang L. A novel definition of the multivariate coefficient of variation. Biom J. 2010;52(5):667\u201375.","journal-title":"Biom J"},{"issue":"23","key":"5760_CR20","doi-asserted-by":"publisher","first-page":"11501","DOI":"10.1021\/ac402735y","volume":"85","author":"JH Kim","year":"2013","unstructured":"Kim JH, Woenker T, Adamec J, Regnier FE. Simple, miniaturized blood plasma extraction method. Anal Chem. 2013;85(23):11501\u20138.","journal-title":"Anal Chem"},{"issue":"10","key":"5760_CR21","doi-asserted-by":"publisher","first-page":"2191","DOI":"10.1007\/s00216-019-02241-y","volume":"412","author":"T Z\u00fcllig","year":"2020","unstructured":"Z\u00fcllig T, Tr\u00f6tzm\u00fcller M, K\u00f6feler HC. Lipidomics from sample preparation to data analysis: a primer. Anal Bioanal Chem. 2020;412(10):2191\u2013209.","journal-title":"Anal Bioanal Chem"},{"issue":"12","key":"5760_CR22","doi-asserted-by":"publisher","first-page":"495","DOI":"10.3390\/metabo10120495","volume":"10","author":"J Medina","year":"2020","unstructured":"Medina J, van der Velpen V, Teav T, Guitton Y, Gallart-Ayala H, Ivanisevic J. Single-step extraction coupled with targeted HILIC-MS\/MS approach for comprehensive analysis of human plasma lipidome and polar metabolome. Metabolites. 2020;10(12):495.","journal-title":"Metabolites"},{"key":"5760_CR23","doi-asserted-by":"publisher","first-page":"6263","DOI":"10.1007\/s00216-017-0571-8","volume":"409","author":"C Volani","year":"2017","unstructured":"Volani C, Caprioli G, Calderisi G, Sigurdsson BB, Rainer J, Gentilini I, et al. Pre-analytic evaluation of volumetric absorptive microsampling and integration in a mass spectrometry-based metabolomics workflow. Anal Bioanal Chem. 2017;409:6263\u201376.","journal-title":"Anal Bioanal Chem"},{"issue":"2","key":"5760_CR24","doi-asserted-by":"publisher","first-page":"146","DOI":"10.3390\/metabo13020146","volume":"13","author":"C Volani","year":"2023","unstructured":"Volani C, Malfertheiner C, Caprioli G, Fjelstrup S, Pramstaller PP, Rainer J, et al. VAMS-based blood capillary sampling for mass spectrometry-based human metabolomics studies. Metabolites. 2023;13(2):146.","journal-title":"Metabolites"}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-025-05760-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00216-025-05760-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-025-05760-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,17]],"date-time":"2025-03-17T08:07:26Z","timestamp":1742198846000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00216-025-05760-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,5]]},"references-count":24,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["5760"],"URL":"https:\/\/doi.org\/10.1007\/s00216-025-05760-z","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,5]]},"assertion":[{"value":"2 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 January 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the local Ethics Committee \u201cComitato Etico Interprovinciale Area 1\u201d (number: 45\/CE\/2021 31 March 2021).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Institutional review board statement"}},{"value":"The study was conducted according to principles of the Declaration of Helsinki (2008) and the International Conference on Harmonization, Good Clinical Practice guidelines. Written informed consent was obtained from all participants in the present study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}