{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T18:55:15Z","timestamp":1783104915884,"version":"3.54.6"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T00:00:00Z","timestamp":1741910400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T00:00:00Z","timestamp":1741910400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"the Natural Science Foundation of Zhejiang Province","award":["LZ22A020005"],"award-info":[{"award-number":["LZ22A020005"]}]},{"name":"the Youth Science Foundation Program of the National Natural Science Foundation of China","award":["82204538"],"award-info":[{"award-number":["82204538"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2025,5]]},"DOI":"10.1007\/s00216-025-05825-z","type":"journal-article","created":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T07:23:47Z","timestamp":1741937027000},"page":"2361-2374","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["High-gradient microstructured hybrid microfluidic chip for rare tumor cell capture"],"prefix":"10.1007","volume":"417","author":[{"given":"Wen","family":"Ding","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wu","family":"Ye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huayan","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianbo","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chengxing","family":"Chu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huancheng","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiakang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luping","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,14]]},"reference":[{"key":"5825_CR1","doi-asserted-by":"publisher","unstructured":"Yuan QQ, Chen L, Wan MM, Mao C, Shen J. Origin, metastasis, harm, recognition and capture, and elimination of circulating tumor cells. Adv Mater Technol. 2024;9(5). https:\/\/doi.org\/10.1002\/admt.202301306.","DOI":"10.1002\/admt.202301306"},{"key":"5825_CR2","doi-asserted-by":"publisher","unstructured":"Wang XL, Wang LJ, Lin HH, Zhu YF, Huang DF, Lai M, et al. Research progress of CTC, ctDNA, and EVs in cancer liquid biopsy. Front Oncol. 2024;14. https:\/\/doi.org\/10.3389\/fonc.2024.1303335.","DOI":"10.3389\/fonc.2024.1303335"},{"key":"5825_CR3","doi-asserted-by":"publisher","unstructured":"Sha LJ, Wang W, Liu Q, Dong LJ, Zhao J, Tu M. An integrated and renewable interface for capture, release and analysis of circulating tumor cells. Anal Chim Acta. 2023;1274. https:\/\/doi.org\/10.1016\/j.aca.2023.341556.","DOI":"10.1016\/j.aca.2023.341556"},{"key":"5825_CR4","doi-asserted-by":"publisher","unstructured":"Edd JF, Mishra A, Smith KC, Kapur R, Maheswaran S, Haber DA, et al. Isolation of circulating tumor cells. Iscience. 2022;25(8). https:\/\/doi.org\/10.1016\/j.isci.2022.104696.","DOI":"10.1016\/j.isci.2022.104696"},{"issue":"3","key":"5825_CR5","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1039\/c0lc90100h","volume":"11","author":"J Den Toonder","year":"2011","unstructured":"Den Toonder J. Circulating tumor cells: the grand challenge. Lab Chip. 2011;11(3):375\u20137. https:\/\/doi.org\/10.1039\/c0lc90100h.","journal-title":"Lab Chip"},{"key":"5825_CR6","doi-asserted-by":"publisher","unstructured":"Bank\u00f3 P, Lee SY, Nagygy\u00f6rgy V, Zr\u00ednyi M, Chae CH, Cho DH, et al. Technologies for circulating tumor cell separation from whole blood. J Hematol Oncol. 2019;12. https:\/\/doi.org\/10.1186\/s13045-019-0735-4.","DOI":"10.1186\/s13045-019-0735-4"},{"issue":"1","key":"5825_CR7","doi-asserted-by":"publisher","first-page":"77","DOI":"10.3892\/or.2016.5235","volume":"37","author":"Y Chikaishi","year":"2017","unstructured":"Chikaishi Y, Yoneda K, Ohnaga T, Tanaka F. EpCAM-independent capture of circulating tumor cells with a \u2018universal CTC-chip.\u2019 Oncol Rep. 2017;37(1):77\u201382. https:\/\/doi.org\/10.3892\/or.2016.5235.","journal-title":"Oncol Rep"},{"issue":"5","key":"5825_CR8","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1039\/d2lc00904h","volume":"23","author":"N Lu","year":"2023","unstructured":"Lu N, Tay HM, Petchakup C, He LW, Gong LY, Maw KK, et al. Label-free microfluidic cell sorting and detection for rapid blood analysis. Lab Chip. 2023;23(5):1226\u201357. https:\/\/doi.org\/10.1039\/d2lc00904h.","journal-title":"Lab Chip"},{"key":"5825_CR9","doi-asserted-by":"publisher","unstructured":"Gong LY, Cretella A, Lin Y. Microfluidic systems for particle capture and release: a review. Biosens Bioelectron. 2023;236. https:\/\/doi.org\/10.1016\/j.bios.2023.115426.","DOI":"10.1016\/j.bios.2023.115426"},{"key":"5825_CR10","doi-asserted-by":"publisher","unstructured":"Ji MM, Duan JP, Zang WX, Luo ZB, Qu Z, Li XH, et al. Ultra-high precision passive particle sorting chip coupling inertial microfluidics and single row micropillar arrays. J Micromech Microeng. 2022;32(4). https:\/\/doi.org\/10.1088\/1361-6439\/ac56e9.","DOI":"10.1088\/1361-6439\/ac56e9"},{"key":"5825_CR11","doi-asserted-by":"publisher","unstructured":"Emmerich MEP, Sinnigen AS, Neubauer P, Birkholz M. Dielectrophoretic separation of blood cells. Biomed Microdevices. 2022;24(3). https:\/\/doi.org\/10.1007\/s10544-022-00623-1.","DOI":"10.1007\/s10544-022-00623-1"},{"issue":"22","key":"5825_CR12","doi-asserted-by":"publisher","first-page":"7103","DOI":"10.1039\/d0an01148g","volume":"145","author":"S Zhu","year":"2020","unstructured":"Zhu S, Jiang FT, Han Y, Xiang N, Ni ZH. Microfluidics for label-free sorting of rare circulating tumor cells. Analyst. 2020;145(22):7103\u201324. https:\/\/doi.org\/10.1039\/d0an01148g.","journal-title":"Analyst"},{"key":"5825_CR13","doi-asserted-by":"publisher","unstructured":"Vasantharajan SS, Barnett E, Gray ES, McCall JL, Rodger EJ, Eccles MR, et al. Assessment of a size-based method for enriching circulating tumour cells in colorectal cancer. Cancers. 2022;14(14). https:\/\/doi.org\/10.3390\/cancers14143446.","DOI":"10.3390\/cancers14143446"},{"key":"5825_CR14","doi-asserted-by":"publisher","unstructured":"Pedrosa VA, Chen KF, George TJ, Fan ZH. Gold nanoparticle-based microfluidic chips for capture and detection of circulating tumor cells. Biosensors. 2023;13(7). https:\/\/doi.org\/10.3390\/bios13070706.","DOI":"10.3390\/bios13070706"},{"key":"5825_CR15","doi-asserted-by":"publisher","unstructured":"Wang H, Zhang YL, Wang W, Ding H, Sun HB. On-chip laser processing for the development of multifunctional microfluidic chips. Laser Photonics Rev. 2017;11(2). https:\/\/doi.org\/10.1002\/lpor.201600116.","DOI":"10.1002\/lpor.201600116"},{"issue":"4","key":"5825_CR16","doi-asserted-by":"publisher","first-page":"1470","DOI":"10.1007\/s12010-019-03199-4","volume":"190","author":"HM Chen","year":"2020","unstructured":"Chen HM. Capturing and clinical applications of circulating tumor cells with wave microfluidic chip. Appl Biochem Biotechnol. 2020;190(4):1470\u201383. https:\/\/doi.org\/10.1007\/s12010-019-03199-4.","journal-title":"Appl Biochem Biotechnol"},{"key":"5825_CR17","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.chroma.2014.12.037","volume":"1377","author":"SW Lee","year":"2015","unstructured":"Lee SW, Hyun KA, Kim SI, Kang JY, Jung HI. Continuous enrichment of circulating tumor cells using a microfluidic lateral flow filtration chip. J Chromatogr A. 2015;1377:100\u20135. https:\/\/doi.org\/10.1016\/j.chroma.2014.12.037.","journal-title":"J Chromatogr A"},{"key":"5825_CR18","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.jare.2022.08.005","volume":"47","author":"M Rahmanian","year":"2023","unstructured":"Rahmanian M, Hematabad OS, Askari E, Shokati F, Bakhshi A, Moghadam S, et al. A micropillar array-based microfluidic chip for label-free separation of circulating tumor cells: the best micropillar geometry? J Adv Res. 2023;47:105\u201321. https:\/\/doi.org\/10.1016\/j.jare.2022.08.005.","journal-title":"J Adv Res"},{"key":"5825_CR19","doi-asserted-by":"publisher","unstructured":"Xu L, Mao XY, Imrali A, Syed F, Mutsvangwa K, Berney D, et al. Optimization and evaluation of a novel size based circulating tumor cell isolation. PLoS One. 2015;10(9). https:\/\/doi.org\/10.1371\/journal.pone.0138032.","DOI":"10.1371\/journal.pone.0138032"},{"issue":"2","key":"5825_CR20","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1515\/cclm-2022-0738","volume":"61","author":"E Obermayr","year":"2023","unstructured":"Obermayr E, Koppensteiner N, Heinzl N, Schuster E, Holzer B, Fabikan H, et al. Effect of short-term storage of blood samples on gene expression in lung cancer patients. Clin Chem Lab Med. 2023;61(2):294\u2013301. https:\/\/doi.org\/10.1515\/cclm-2022-0738.","journal-title":"Clin Chem Lab Med"},{"key":"5825_CR21","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.addr.2018.01.002","volume":"125","author":"SJ Hao","year":"2018","unstructured":"Hao SJ, Wan Y, Xia YQ, Zou X, Zheng SY. Size-based separation methods of circulating tumor cells. Adv Drug Deliver Rev. 2018;125:3\u201320. https:\/\/doi.org\/10.1016\/j.addr.2018.01.002.","journal-title":"Adv Drug Deliver Rev"},{"issue":"23","key":"5825_CR22","doi-asserted-by":"publisher","first-page":"10471","DOI":"10.1021\/ac302763n","volume":"84","author":"S Cha","year":"2012","unstructured":"Cha S, Shin T, Lee SS, Shim W, Lee G, Lee SJ, et al. Cell stretching measurement utilizing viscoelastic particle focusing. Anal Chem. 2012;84(23):10471\u20137. https:\/\/doi.org\/10.1021\/ac302763n.","journal-title":"Anal Chem"},{"key":"5825_CR23","doi-asserted-by":"publisher","first-page":"100043","DOI":"10.1016\/j.revip.2020.100043","volume":"5","author":"T Avsievich","year":"2020","unstructured":"Avsievich T, Zhu R, Popov A, Bykov A, Meglinski I. The advancement of blood cell research by optical tweezers. Rev Phys. 2020;5:100043. https:\/\/doi.org\/10.1016\/j.revip.2020.100043.","journal-title":"Rev Phys"},{"issue":"18","key":"5825_CR24","doi-asserted-by":"publisher","first-page":"6548","DOI":"10.1021\/acs.langmuir.3c00514","volume":"39","author":"YC Zhang","year":"2023","unstructured":"Zhang YC, Huang LK, Guo JJ, Ji J, Wei TY, Fu L. Study on microfluidic chip flow rate uniformity for cell activity detection. Langmuir. 2023;39(18):6548\u201355. https:\/\/doi.org\/10.1021\/acs.langmuir.3c00514.","journal-title":"Langmuir"},{"key":"5825_CR25","doi-asserted-by":"publisher","unstructured":"Coumans FAW, van Dalum G, Beck M, Terstappen L. Filter characteristics influencing circulating tumor cell enrichment from whole blood. PLoS One. 2013;8(4). https:\/\/doi.org\/10.1371\/journal.pone.0061770.","DOI":"10.1371\/journal.pone.0061770"},{"issue":"1","key":"5825_CR26","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1177\/24.1.56391","volume":"24","author":"HM Shapiro","year":"1976","unstructured":"Shapiro HM, Schildkraut ER, Curbelo R, Laird CW, Turner RB, Hirschfeld T. Combined blood-cell counting and classification with fluorochrome stains and flow instrumentation. J Histochem Cytochem. 1976;24(1):396\u2013411. https:\/\/doi.org\/10.1177\/24.1.56391.","journal-title":"J Histochem Cytochem"},{"key":"5825_CR27","doi-asserted-by":"publisher","unstructured":"Ruban GI, Kosmacheva SM, Goncharova NV, Van Bockstaele D, Loiko VA. Investigation of morphometric parameters for granulocytes and lymphocytes as applied to a solution of direct and inverse light-scattering problems. J Biomed Opt. 2007;12(4). https:\/\/doi.org\/10.1117\/1.2753466.","DOI":"10.1117\/1.2753466"},{"key":"5825_CR28","doi-asserted-by":"publisher","unstructured":"Ozkumur E, Shah AM, Ciciliano JC, Emmink BL, Miyamoto DT, Brachtel E, et al. Inertial focusing for tumor antigen-dependent and -independent sorting of rare circulating tumor cells. Sci Transl Med. 2013;5(179). https:\/\/doi.org\/10.1126\/scitranslmed.3005616.","DOI":"10.1126\/scitranslmed.3005616"},{"issue":"19","key":"5825_CR29","doi-asserted-by":"publisher","first-page":"16327","DOI":"10.1021\/acsami.8b04683","volume":"10","author":"R Li","year":"2018","unstructured":"Li R, Chen FF, Liu HQ, Wang ZX, Zhang ZT, Wang Y, et al. Efficient capture and high activity release of circulating tumor cells by using TiO2 nanorod arrays coated with soluble MnO2 nanoparticles. ACS Appl Mater Interfaces. 2018;10(19):16327\u201334. https:\/\/doi.org\/10.1021\/acsami.8b04683.","journal-title":"ACS Appl Mater Interfaces"},{"key":"5825_CR30","doi-asserted-by":"publisher","unstructured":"Sano R, Koyama K, Fukuoka N, Ueno H, Yamamura S, Suzuki T. Single-cell microarray chip with inverse-tapered wells to maintain high ratio of cell trapping. Micromachines. 2023;14(2). https:\/\/doi.org\/10.3390\/mi14020492.","DOI":"10.3390\/mi14020492"},{"key":"5825_CR31","doi-asserted-by":"publisher","unstructured":"Tokas S, Zunaid M, Ansari MA. Numerical investigation of the performance of 3D-helical passive micromixer with Newtonian fluid and non-Newtonian fluid blood. Asia Pac. J Chem Eng. 2021;16(1). https:\/\/doi.org\/10.1002\/apj.2570.","DOI":"10.1002\/apj.2570"},{"issue":"16","key":"5825_CR32","doi-asserted-by":"publisher","first-page":"3053","DOI":"10.1039\/d1lc00288k","volume":"21","author":"A Shakeri","year":"2021","unstructured":"Shakeri A, Khan S, Didar TF. Conventional and emerging strategies for the fabrication and functionalization of PDMS-based microfluidic devices. Lab Chip. 2021;21(16):3053\u201375. https:\/\/doi.org\/10.1039\/d1lc00288k.","journal-title":"Lab Chip"},{"issue":"24","key":"5825_CR33","doi-asserted-by":"publisher","first-page":"9864","DOI":"10.1016\/j.apsusc.2012.06.044","volume":"258","author":"S Hemmil\u00e4","year":"2012","unstructured":"Hemmil\u00e4 S, Cauich-Rodr\u00edguez JV, Kreutzer J, Kallio P. Rapid, simple, and cost-effective treatments to achieve long-term hydrophilic PDMS surfaces. Appl Surf Sci. 2012;258(24):9864\u201375. https:\/\/doi.org\/10.1016\/j.apsusc.2012.06.044.","journal-title":"Appl Surf Sci"},{"key":"5825_CR34","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.bios.2017.11.026","volume":"102","author":"N Sun","year":"2018","unstructured":"Sun N, Li XP, Wang ZL, Li YZ, Pei RJ. High-purity capture of CTCs based on micro-beads enhanced isolation by size of epithelial tumor cells (ISET) method. Biosens Bioelectron. 2018;102:157\u201363. https:\/\/doi.org\/10.1016\/j.bios.2017.11.026.","journal-title":"Biosens Bioelectron"},{"key":"5825_CR35","doi-asserted-by":"publisher","unstructured":"Wu C, Almuaalemi HYM, Sohan A, Yin BF. Effect of flow velocity on laminar flow in microfluidic chips. Micromachines. 2023;14(7). https:\/\/doi.org\/10.3390\/mi14071277.","DOI":"10.3390\/mi14071277"},{"key":"5825_CR36","doi-asserted-by":"publisher","unstructured":"Ramani VC, Lemaire CA, Triboulet M, Casey KM, Heirich K, Renier C, et al. Investigating circulating tumor cells and distant metastases in patient-derived orthotopic xenograft models of triple-negative breast cancer. Breast Cancer Res. 2019;21(1). https:\/\/doi.org\/10.1186\/s13058-019-1182-4.","DOI":"10.1186\/s13058-019-1182-4"},{"key":"5825_CR37","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1016\/j.bios.2016.09.092","volume":"89","author":"KF Pu","year":"2017","unstructured":"Pu KF, Li CL, Zhang NP, Wang H, Shen WJ, Zhu YM. Epithelial cell adhesion molecule independent capture of non-small lung carcinoma cells with peptide modified microfluidic chip. Biosens Bioelectron. 2017;89:927\u201331. https:\/\/doi.org\/10.1016\/j.bios.2016.09.092.","journal-title":"Biosens Bioelectron"},{"key":"5825_CR38","doi-asserted-by":"publisher","unstructured":"Tu J, Qiao Y, Xu MH, Li JJ, Liang FP, Duan MQ, et al. A cell sorting and trapping microfluidic device with an interdigital channel. Aip Adv. 2016;6(12). https:\/\/doi.org\/10.1063\/1.4972794.","DOI":"10.1063\/1.4972794"},{"key":"5825_CR39","doi-asserted-by":"publisher","unstructured":"Sun YS. Comparison of chip inlet geometry in microfluidic devices for cell studies. Molecules. 2016;21(6). https:\/\/doi.org\/10.3390\/molecules21060778.","DOI":"10.3390\/molecules21060778"},{"issue":"1","key":"5825_CR40","doi-asserted-by":"publisher","first-page":"545","DOI":"10.3390\/cancers6010545","volume":"6","author":"PRC Gascoyne","year":"2014","unstructured":"Gascoyne PRC, Shim S. Isolation of circulating tumor cells by dielectrophoresis. Cancers. 2014;6(1):545\u201379. https:\/\/doi.org\/10.3390\/cancers6010545.","journal-title":"Cancers"},{"issue":"8","key":"5825_CR41","doi-asserted-by":"publisher","first-page":"1388","DOI":"10.1002\/elps.200800373","volume":"30","author":"PRC Gascoyne","year":"2009","unstructured":"Gascoyne PRC, Noshari J, Anderson TJ, Becker FF. Isolation of rare cells from cell mixtures by dielectrophoresis. Electrophoresis. 2009;30(8):1388\u201398. https:\/\/doi.org\/10.1002\/elps.200800373.","journal-title":"Electrophoresis"},{"issue":"12","key":"5825_CR42","doi-asserted-by":"publisher","first-page":"2894","DOI":"10.1002\/ijc.30007","volume":"138","author":"GE Hvichia","year":"2016","unstructured":"Hvichia GE, Parveen Z, Wagner C, Janning M, Quidde J, Stein A, et al. A novel microfluidic platform for size and deformability based separation and the subsequent molecular characterization of viable circulating tumor cells. Int J Cancer. 2016;138(12):2894\u2013904. https:\/\/doi.org\/10.1002\/ijc.30007.","journal-title":"Int J Cancer"},{"issue":"1","key":"5825_CR43","doi-asserted-by":"publisher","first-page":"26","DOI":"10.33393\/jcb.2023.2629","volume":"12","author":"A Templeman","year":"2023","unstructured":"Templeman A, Miller MC, Cooke MJ, O\u2019Shannessy DJ, Gurung Y, Pereira T, et al. Analytical performance of the FDA-cleared Parsortix\u00ae PC1 system. J Circ Biomark. 2023;12(1):26\u201333. https:\/\/doi.org\/10.33393\/jcb.2023.2629.","journal-title":"J Circ Biomark"}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-025-05825-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00216-025-05825-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-025-05825-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T08:36:06Z","timestamp":1744619766000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00216-025-05825-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,14]]},"references-count":43,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["5825"],"URL":"https:\/\/doi.org\/10.1007\/s00216-025-05825-z","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,14]]},"assertion":[{"value":"5 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"For research involving animal studies, the experiments were performed following the guidelines and regulations for the care and use of laboratory animals as approved by the Institutional Animal Care and Use Committee (IACUC) of Chinese Academy of Sciences Hangzhou Institute of Medicine, with approval No. AP2024-10\u20130224. Efforts were made to minimize animal suffering and to use the minimum number of animals necessary for the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}