{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T07:24:09Z","timestamp":1794036249573,"version":"4.8.0"},"reference-count":61,"publisher":"Springer Science and Business Media LLC","issue":"23","license":[{"start":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T00:00:00Z","timestamp":1784505600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T00:00:00Z","timestamp":1784505600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4t des Saarlandes","id":[{"id":"https:\/\/ror.org\/01jdpyv68","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"published-print":{"date-parts":[[2026,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>In gas measurements, there is inherent competition between sensors and analytical systems, often made difficult by a lack of understanding of approaches and constraints from both sides. This leads to controversies, sometimes simple to avoid or defuse, but sometimes leading to harsh discussions and resentment of \u201cwrong\u201d concepts from the respective other side. Meanwhile, collaboration between disciplines is often a key to scientific and, in the long term, economic and societal success. This is especially true today, when digitization is the pervasive topic in our society and where \u201csensors act as a bridge between biology and digitization.\u201d This article addresses this conflict for the field of high-performance gas measurement systems, where the two worlds of low-cost sensor systems on the one hand and high-performance analytical instruments on the other are still often at odds.<\/jats:p>","DOI":"10.1007\/s00216-026-06675-z","type":"journal-article","created":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T21:00:38Z","timestamp":1784581238000},"page":"7739-7746","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["High-performance gas measurement systems\u2014bridging the gap between sensors and analytics"],"prefix":"10.1007","volume":"418","author":[{"given":"Andreas","family":"Sch\u00fctze","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tilman","family":"Sauerwald","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Bur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,20]]},"reference":[{"key":"6675_CR1","doi-asserted-by":"publisher","DOI":"10.1007\/s00216-026-06332-5","author":"G Gauglitz","year":"2026","unstructured":"Gauglitz G. Spotlight on sensors as tools for biointelligence. Anal Bioanal Chem. 2026. https:\/\/doi.org\/10.1007\/s00216-026-06332-5.","journal-title":"Anal Bioanal Chem"},{"key":"6675_CR2","unstructured":"Jaaniso R, Tan OK. (eds.) Semiconductor Gas Sensors 2nd Edition, 2019 Woodhead Publishing. https:\/\/shop.elsevier.com\/books\/semiconductor-gas-sensors\/jaaniso\/978-0-08-102559-8."},{"issue":"1\u20133","key":"6675_CR3","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1016\/0925-4005(94)87085-3","volume":"18","author":"JW Gardner","year":"1994","unstructured":"Gardner JW, Bartlett PN. A brief history of electronic noses. Sens Actuators B Chem. 1994;18(1\u20133):210\u20131. https:\/\/doi.org\/10.1016\/0925-4005(94)87085-3.","journal-title":"Sens Actuators B Chem"},{"key":"6675_CR4","doi-asserted-by":"publisher","DOI":"10.1002\/3527601597","author":"TC Pearce","year":"2003","unstructured":"Pearce TC, Schiffman SS, Nagle HT, Gardner JW. Handbook of machine olfaction: electronic nose technology. Wiley-VCH. 2003. https:\/\/doi.org\/10.1002\/3527601597.","journal-title":"Wiley-VCH"},{"issue":"2","key":"6675_CR5","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1021\/cr068121q","volume":"108","author":"F R\u00f6ck","year":"2008","unstructured":"R\u00f6ck F, Barsan N, Weimar U. Electronic nose: current status and future trends. Chem Rev. 2008;108(2):705\u201325. https:\/\/doi.org\/10.1021\/cr068121q.","journal-title":"Chem Rev"},{"key":"6675_CR6","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1038\/299352a0","volume":"299","author":"K Persaud","year":"1982","unstructured":"Persaud K, Dodd G. Analysis of discrimination mechanisms in the mammalian olfactory system using a model nose. Nature. 1982;299:352\u20135. https:\/\/doi.org\/10.1038\/299352a0.","journal-title":"Nature"},{"issue":"1","key":"6675_CR7","first-page":"231","volume":"1","author":"JN Andres","year":"2021","unstructured":"Andres JN, Siddiqui H, Fong M. The chemists\u2019 gold: an analysis of gas chromatography-mass spectrometry and future directions. Voices of Forensic Science. 2021;1(1):231\u201349.","journal-title":"Voices of Forensic Science"},{"key":"6675_CR8","unstructured":"Directive 2008\/50\/EC of the European Parliament and the Council of 21 May 2008 on ambient air quality and cleaner air for Europe, Official Journal of the European Union L 152\/1 of 11.6. 2008. http:\/\/eur-lex.europa.eu. Accessed 26 Apr 2026."},{"key":"6675_CR9","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/j.pmcj.2014.11.008","volume":"16","author":"D Hasenfratz","year":"2015","unstructured":"Hasenfratz D, Saukh O, Walser C, Hueglin C, Fierz M, Arn T, Beutel J, Thiele L. Deriving high-resolution urban air pollution maps using mobile sensor nodes. Pervasive Mob Comput. 2015;16:268\u201385. https:\/\/doi.org\/10.1016\/j.pmcj.2014.11.008.","journal-title":"Pervasive Mob Comput"},{"key":"6675_CR10","doi-asserted-by":"publisher","DOI":"10.3390\/environments8120137","volume":"8","author":"P Brimblecombe","year":"2021","unstructured":"Brimblecombe P, Chu M-Y, Liu C-H, Ning Z. NOx and CO fluctuations in a busy street canyon. Environments (Basel). 2021;8: 137. https:\/\/doi.org\/10.3390\/environments8120137.","journal-title":"Environments (Basel)"},{"key":"6675_CR11","doi-asserted-by":"publisher","DOI":"10.3390\/s18041052","volume":"18","author":"D R\u00fcffer","year":"2018","unstructured":"R\u00fcffer D, Hoehne F, B\u00fchler J. New digital metal-oxide (MOx) sensor platform. Sensors (Basel). 2018;18: 1052.","journal-title":"Sensors (Basel)"},{"key":"6675_CR12","doi-asserted-by":"publisher","DOI":"10.3389\/fsens.2023.1317533","author":"W Reimringer","year":"2023","unstructured":"Reimringer W, Bur C. Promoting quality in low-cost gas sensor devices for real-world applications. Front Sens. 2023. https:\/\/doi.org\/10.3389\/fsens.2023.1317533.","journal-title":"Front Sens"},{"key":"6675_CR13","unstructured":"Sensirion: Datasheet SGP41 - Air quality sensor for VOC and NOx measurements, version 1.0 \u2013; 2021.https:\/\/sensirion.com\/media\/documents\/5FE8673C\/61E96F50\/Sensirion_Gas_Sensors_Datasheet_SGP41.pdf. Accessed 26 Apr 2026."},{"key":"6675_CR14","unstructured":"ScioSense: ENS160 - Digital metal-oxide multi-gas sensor, datasheet version 1.3 SC-001224-DS-9, March 2023.  https:\/\/www.sciosense.com\/wp-content\/uploads\/2023\/12\/ENS160-Datasheet.pdf. Accessed 26 Apr 2026."},{"key":"6675_CR15","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/19\/5\/055205","volume":"19","author":"W Maziarz","year":"2008","unstructured":"Maziarz W, Pisarkiewicz T. Gas sensors in a dynamic operation mode. Meas Sci Technol. 2008;19: 055205. https:\/\/doi.org\/10.1088\/0957-0233\/19\/5\/055205.","journal-title":"Meas Sci Technol"},{"key":"6675_CR16","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1016\/B978-0-08-102559-8.00012-4","volume-title":"Semiconductor gas sensors","author":"A Sch\u00fctze","year":"2020","unstructured":"Sch\u00fctze A, Sauerwald T. Dynamic operation of semiconductor sensors. In: Jaaniso R, Kiang Tan O, editors. Semiconductor gas sensors. 2nd ed. Woodhead Publishing; 2020. p. 385\u2013412. https:\/\/doi.org\/10.1016\/B978-0-08-102559-8.00012-4.","edition":"2"},{"key":"6675_CR17","unstructured":"CEN\/TS 17660\u20131 Air quality \u2014 Performance evaluation of air quality sensor systems \u2014 Part 1: Gaseous pollutants in ambient air; 2021.  https:\/\/www.boutique.afnor.org\/en-gb\/standard\/din-cen-ts-176601\/air-quality-performance-evaluation-of-air-quality-sensor-systems-part-1-gas\/eu174644\/322334. Accessed 26 Apr 2026."},{"key":"6675_CR18","doi-asserted-by":"publisher","unstructured":"Yatkin S, Gerboles M, Borowiak A, Signorini M. Guidance on low-cost air quality sensor deployment for non-experts based on the AirSensEUR experience, Publications Office of the European Union. Luxembourg. 2022. https:\/\/doi.org\/10.2760\/180094,JRC130628.","DOI":"10.2760\/180094,JRC130628"},{"key":"6675_CR19","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/25\/5\/055903","volume":"25","author":"N Helwig","year":"2014","unstructured":"Helwig N, Sch\u00fcler M, Bur C, Sch\u00fctze A, Sauerwald T. Gas mixing apparatus for automated gas sensor characterization. Meas Sci Technol. 2014;25: 055903. https:\/\/doi.org\/10.1088\/0957-0233\/25\/5\/055903.","journal-title":"Meas Sci Technol"},{"issue":"12","key":"6675_CR20","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1515\/teme-2023-0075","volume":"90","author":"D Arendes","year":"2023","unstructured":"Arendes D, Amann J, Tessier C, Brieger O, Sch\u00fctze A, Bur C. Qualification and optimisation of a gas mixing apparatus for complex trace gas mixtures. tm-Tech Mess. 2023;90(12):822\u201334. https:\/\/doi.org\/10.1515\/teme-2023-0075.","journal-title":"tm-Tech Mess"},{"key":"6675_CR21","doi-asserted-by":"publisher","unstructured":"Spinelle L, Michel G, Aleixandre M. Report of laboratory and in-situ validation of micro-sensor for monitoring ambient air pollution, Publication Office of the European Union. Luxembourg. 2014. https:\/\/doi.org\/10.2788\/4277.","DOI":"10.2788\/4277"},{"issue":"11","key":"6675_CR22","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.3390\/atmos12111487","volume":"12","author":"Y Robin","year":"2021","unstructured":"Robin Y, Amann J, Baur T, Goodarzi P, Schultealbert C, Schneider T, Sch\u00fctze A. High-performance VOC quantification for IAQ monitoring using advanced sensor systems and deep learning. Atmosphere (Basel). 2021;12(11):1487. https:\/\/doi.org\/10.3390\/atmos12111487.","journal-title":"Atmosphere (Basel)"},{"key":"6675_CR23","doi-asserted-by":"publisher","first-page":"411","DOI":"10.5194\/jsss-9-411-2020","volume":"9","author":"T Baur","year":"2020","unstructured":"Baur T, Bastuck M, Schultealbert C, Sauerwald T, Sch\u00fctze A. Random gas mixtures for efficient gas sensor calibration. J Sens Sens Syst. 2020;9:411\u201324. https:\/\/doi.org\/10.5194\/jsss-9-411-2020.","journal-title":"J Sens Sens Syst"},{"key":"6675_CR24","doi-asserted-by":"publisher","unstructured":"Russell HS, Frederickson LB, Kwiatkowski S, Emygdio APM, Kumar P, Schmidt JA, et al. Enhanced ambient sensing environment \u2014 a new method for calibrating low-cost gas sensors. Sensors (Basel). 2022;22(7238):1\u201329.  https:\/\/doi.org\/10.3390\/s22197238.","DOI":"10.3390\/s22197238"},{"key":"6675_CR25","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1016\/j.snb.2016.07.036","volume":"238","author":"L Spinelle","year":"2017","unstructured":"Spinelle L, Gerboles M, Villani MG, Aleixandre M, Bonavitacola F. Field calibration of a cluster of low-cost commercially available sensors for air quality monitoring. Part B: NO, CO and CO2. Sens Actuators B Chem. 2017;238:706\u201315. https:\/\/doi.org\/10.1016\/j.snb.2016.07.036.","journal-title":"Sens Actuators B Chem"},{"issue":"3","key":"6675_CR26","doi-asserted-by":"publisher","DOI":"10.3390\/atmos12030366","volume":"12","author":"C Schultealbert","year":"2021","unstructured":"Schultealbert C, Amann J, Baur T, Sch\u00fctze A. Measuring hydrogen in indoor air with a selective metal oxide semiconductor sensor. Atmosphere (Basel). 2021;12(3): 366. https:\/\/doi.org\/10.3390\/atmos12030366.","journal-title":"Atmosphere (Basel)"},{"issue":"3","key":"6675_CR27","doi-asserted-by":"publisher","DOI":"10.3390\/s25030831","volume":"25","author":"P Goodarzi","year":"2025","unstructured":"Goodarzi P, Schauer J, Sch\u00fctze A. Robust distribution-aware ensemble learning for multi-sensor systems. Sensors (Basel). 2025;25(3): 831. https:\/\/doi.org\/10.3390\/s25030831.","journal-title":"Sensors (Basel)"},{"issue":"4","key":"6675_CR28","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1515\/teme-2021-0129","volume":"89","author":"P Goodarzi","year":"2022","unstructured":"Goodarzi P, Sch\u00fctze A, Schneider T. Comparison of different ML methods concerning prediction quality, domain adaptation and robustness. tm-Tech Mess. 2022;89(4):224\u201339. https:\/\/doi.org\/10.1515\/teme-2021-0129.","journal-title":"tm-Tech Mess"},{"key":"6675_CR29","doi-asserted-by":"publisher","DOI":"10.3390\/atmos12050647","volume":"12","author":"T Baur","year":"2021","unstructured":"Baur T, Amann J, Schultealbert C, Sch\u00fctze A. Field study of metal oxide semiconductor gas sensors in temperature cycled operation for selective VOC monitoring in indoor air. Atmosphere (Basel). 2021;12: 647. https:\/\/doi.org\/10.3390\/atmos12050647.","journal-title":"Atmosphere (Basel)"},{"key":"6675_CR30","doi-asserted-by":"publisher","first-page":"898","DOI":"10.1038\/s41586-026-10099-1","volume":"650","author":"JD Patterson","year":"2026","unstructured":"Patterson JD, Aydin M, Miranda MH, Saltzman ES. Atmospheric H2 variability over the past 1,100 years. Nature. 2026;650:898\u2013902. https:\/\/doi.org\/10.1038\/s41586-026-10099-1.","journal-title":"Nature"},{"key":"6675_CR31","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1016\/j.snb.2018.06.097","volume":"273","author":"M Bastuck","year":"2018","unstructured":"Bastuck M, Baur T, Richter M, Mull B, Sch\u00fctze A, Sauerwald T. Comparison of ppb-level gas measurements with a metal-oxide semiconductor gas sensor in two independent laboratories. Sens Actuators B Chem. 2018;273:1037\u201346. https:\/\/doi.org\/10.1016\/j.snb.2018.06.097.","journal-title":"Sens Actuators B Chem"},{"issue":"2","key":"6675_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2025.138396","volume":"444","author":"O Brieger","year":"2025","unstructured":"Brieger O, Bur C, Sch\u00fctze A, Sauerwald T. Setup for characterization of MOS gas sensors as GC detector. Sens Actuators B Chem. 2025;444(2): 138396. https:\/\/doi.org\/10.1016\/j.snb.2025.138396.","journal-title":"Sens Actuators B Chem"},{"key":"6675_CR33","doi-asserted-by":"publisher","first-page":"75","DOI":"10.5194\/jsss-14-75-2025","volume":"14","author":"M Koehne","year":"2025","unstructured":"Koehne M, Penagos Carrascal OT, Czerny M, Zeh G, Sauerwald T. A versatile development platform for odor monitoring systems. J Sens Sens Syst. 2025;14:75\u201388. https:\/\/doi.org\/10.5194\/jsss-14-75-2025.","journal-title":"J Sens Sens Syst"},{"key":"6675_CR34","doi-asserted-by":"publisher","first-page":"235","DOI":"10.5194\/jsss-7-235-2018","volume":"7","author":"T Sauerwald","year":"2018","unstructured":"Sauerwald T, Baur T, Leidinger M, Reimringer W, Spinelle L, Gerboles M, Kok G, Sch\u00fctze A. Highly sensitive benzene detection with metal oxide semiconductor gas sensors \u2013 an inter-laboratory comparison. J Sens Sens Syst. 2018;7:235\u201343. https:\/\/doi.org\/10.5194\/jsss-7-235-2018.","journal-title":"J Sens Sens Syst"},{"key":"6675_CR35","doi-asserted-by":"publisher","unstructured":"Fagiani M, Squartini S, Severini M, Piazza F. A novelty detection approach to identify the occurrence of leakage in smart gas and water grids. 2015 International Joint Conference on Neural Networks (IJCNN), Killarney, Ireland; 2015. pp. 1\u20138, https:\/\/doi.org\/10.1109\/IJCNN.2015.7280473.","DOI":"10.1109\/IJCNN.2015.7280473"},{"issue":"3","key":"6675_CR36","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1109\/JSEN.2006.874015","volume":"6","author":"A Perera","year":"2006","unstructured":"Perera A, Papamichail N, Barsan N, Weimar U, Marco S. On-line novelty detection by recursive dynamic principal component analysis and gas sensor arrays under drift conditions. IEEE Sens J. 2006;6(3):770\u201383. https:\/\/doi.org\/10.1109\/JSEN.2006.874015.","journal-title":"IEEE Sens J"},{"issue":"11","key":"6675_CR37","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1515\/teme-2019-0086","volume":"86","author":"T Schneider","year":"2019","unstructured":"Schneider T, Klein S, Sch\u00fctze A. Machine learning in industrial measurement technology for detection of known and unknown faults of equipment and sensors. tm - Tech Mess. 2019;86(11):706\u201318. https:\/\/doi.org\/10.1515\/teme-2019-0086.","journal-title":"tm - Tech Mess"},{"key":"6675_CR38","doi-asserted-by":"publisher","first-page":"101684","DOI":"10.1016\/j.uclim.2023.101684","volume":"52","author":"LB Frederickson","year":"2023","unstructured":"Frederickson LB, Russell HS, Fessa D, Khan J, Schmidt JA, Johnson MS, Hertel O. Hyperlocal air pollution in an urban environment \u2013 measured with low-cost sensors. Urban Climate. 2023;52:101684\u201399. https:\/\/doi.org\/10.1016\/j.uclim.2023.101684.","journal-title":"Urban Climate"},{"key":"6675_CR39","doi-asserted-by":"publisher","unstructured":"Kabadayi S, Pridgen A, Julien C. Virtual sensors: abstracting data from physical sensors. International Symposium on a World of Wireless, Mobile and Multimedia Networks. 2006;587\u2013592.  https:\/\/doi.org\/10.1109\/WOWMOM.2006.115.","DOI":"10.1109\/WOWMOM.2006.115"},{"key":"6675_CR40","doi-asserted-by":"publisher","first-page":"359","DOI":"10.5194\/jsss-7-359-2018","volume":"7","author":"A Sch\u00fctze","year":"2018","unstructured":"Sch\u00fctze A, Helwig N, Schneider T. Sensors 4.0 - smart sensors and measurement technology enable Industry 4.0. J Sens Sens Syst. 2018;7:359\u201371. https:\/\/doi.org\/10.5194\/jsss-7-359-2018.","journal-title":"J Sens Sens Syst"},{"key":"6675_CR41","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/j.snb.2016.08.002","volume":"239","author":"C Schultealbert","year":"2017","unstructured":"Schultealbert C, Baur T, Sch\u00fctze A, B\u00f6ttcher S, Sauerwald T. A novel approach towards calibrated measurement of trace gases using metal oxide semiconductor sensors. Sens Actuators B Chem. 2017;239:390\u20136. https:\/\/doi.org\/10.1016\/j.snb.2016.08.002.","journal-title":"Sens Actuators B Chem"},{"key":"6675_CR42","doi-asserted-by":"publisher","first-page":"988","DOI":"10.1016\/j.snb.2016.04.064","volume":"236","author":"M Leidinger","year":"2016","unstructured":"Leidinger M, Rieger M, Sauerwald T, Al\u00e9p\u00e9e C, Sch\u00fctze A. Integrated pre-concentrator gas sensor microsystem for ppb level benzene detection. Sens Actuators B Chem. 2016;236:988\u201396. https:\/\/doi.org\/10.1016\/j.snb.2016.04.064.","journal-title":"Sens Actuators B Chem"},{"key":"6675_CR43","doi-asserted-by":"publisher","unstructured":"Zampolli S, Elmi I, Cardinali GC, Masini L, Zani A, Severi M, Betti P, Dalcanale E. A palm-sized gas-chromatographic system for sub-ppb VOC detection in air quality monitoring applications, IEEE SENSORS 2006, Daegu, Korea (South), 1163\u20131166 (2006).  https:\/\/doi.org\/10.1109\/ICSENS.2007.355837.","DOI":"10.1109\/ICSENS.2007.355837"},{"key":"6675_CR44","doi-asserted-by":"publisher","first-page":"35","DOI":"10.5194\/jsss-15-35-2026","volume":"15","author":"W Reimringer","year":"2026","unstructured":"Reimringer W, Haug H, Sauerwald T. Inline gas-phase sampling methods for contaminant monitoring in polyolefin recycling. J Sens Sens Syst. 2026;15:35\u201346. https:\/\/doi.org\/10.5194\/jsss-15-35-2026.","journal-title":"J Sens Sens Syst"},{"key":"6675_CR45","unstructured":"Bur C, Amann J, Jungbluth T, Fichtinger T, Siebenhandl A, Stieger S, Sch\u00fctze A. Indoor Air Quality and Adolescents\u2019 Cognitive Performance: First Results of CO2 and VOC Levels of a Longitudinal Large-Scale Field Study, Healthy Buildings Europe 2025, Reykjavik, Iceland, 872 (2025)."},{"key":"6675_CR46","unstructured":"Frederickson LB. Assessment of Air Quality in Primary Schools in Denmark using Multimodal Sensor Nodes, Healthy Buildings 2025, Reykjavik, Iceland, 792 (2025)."},{"issue":"2","key":"6675_CR47","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1016\/j.foodchem.2009.09.097","volume":"120","author":"DL Garc\u00eda-Gonz\u00e1lez","year":"2010","unstructured":"Garc\u00eda-Gonz\u00e1lez DL, Aparicio R. Coupling MOS sensors and gas chromatography to interpret the sensor responses to complex food aroma: application to virgin olive oil. Food Chem. 2010;120(2):572\u20139. https:\/\/doi.org\/10.1016\/j.foodchem.2009.09.097.","journal-title":"Food Chem"},{"issue":"3","key":"6675_CR48","doi-asserted-by":"publisher","DOI":"10.3390\/chemosensors14030073","volume":"14","author":"J Joppich","year":"2026","unstructured":"Joppich J, Sch\u00fctze A, Bur C. Using human assessment and GC-MS to identify potential use cases for evaluating food condition with gas sensor systems. Chemosensors. 2026;14(3): 73. https:\/\/doi.org\/10.3390\/chemosensors14030073.","journal-title":"Chemosensors"},{"issue":"7","key":"6675_CR49","doi-asserted-by":"publisher","DOI":"10.3390\/chemosensors14070148","volume":"14","author":"L Masi","year":"2026","unstructured":"Masi L, Gurusamy R, Garcia-Romeo D, Sch\u00fctze A, Pag\u00e1n R, Bur C. Assessment of cooked meatballs\u2019 edibility using calibrated MOS sensors and microbiological validation. Chemosensors. 2026;14(7): 148. https:\/\/doi.org\/10.3390\/chemosensors14070148.","journal-title":"Chemosensors"},{"issue":"2","key":"6675_CR50","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7155\/8\/2\/027112","volume":"8","author":"N Queralto","year":"2014","unstructured":"Queralto N, Berliner AN, Goldsmith B, Martino R, Rhodes P, Lim SH. Detecting cancer by breath volatile organic compound analysis: a review of array-based sensors. J Breath Res. 2014;8(2): 027112. https:\/\/doi.org\/10.1088\/1752-7155\/8\/2\/027112.","journal-title":"J Breath Res"},{"key":"6675_CR51","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.aca.2014.03.014","volume":"824","author":"C Di Natale","year":"2014","unstructured":"Di Natale C, Paolesse R, Martinelli E, Capuano R. Solid-state gas sensors for breath analysis: a review. Anal Chim Acta. 2014;824:1\u201317. https:\/\/doi.org\/10.1016\/j.aca.2014.03.014.","journal-title":"Anal Chim Acta"},{"key":"6675_CR52","doi-asserted-by":"publisher","first-page":"38643","DOI":"10.18632\/oncotarget.5938","volume":"6","author":"A Krilaviciute","year":"2015","unstructured":"Krilaviciute A, Heiss JA, Leja M, Kupcinskas J, Haick H, Brenner H. Detection of cancer through exhaled breath: a systematic review. Oncotarget. 2015;6:38643\u201357. https:\/\/doi.org\/10.18632\/oncotarget.5938.","journal-title":"Oncotarget"},{"issue":"152","key":"6675_CR53","doi-asserted-by":"publisher","DOI":"10.1183\/16000617.0002-2019","volume":"28","author":"R Einoch Amor","year":"2019","unstructured":"Einoch Amor R, Nakhleh MK, Barash O, Haick H. Breath analysis of cancer in the present and the future. Eur Respir Rev. 2019;28(152): 190002. https:\/\/doi.org\/10.1183\/16000617.0002-2019.","journal-title":"Eur Respir Rev"},{"issue":"2","key":"6675_CR54","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1021\/acssensors.8b00937","volume":"4","author":"AT G\u00fcntner","year":"2019","unstructured":"G\u00fcntner AT, Abegg S, K\u00f6nigstein K, Gerber PA, Schmidt-Trucks\u00e4ss A, Pratsinis SE. Breath sensors for health monitoring. ACS Sensors. 2019;4(2):268\u201380. https:\/\/doi.org\/10.1021\/acssensors.8b00937.","journal-title":"ACS Sensors"},{"issue":"6","key":"6675_CR55","doi-asserted-by":"publisher","DOI":"10.3390\/chemosensors11060317","volume":"11","author":"N Lagopati","year":"2023","unstructured":"Lagopati N, Valamvanos T-F, Proutsou V, Karachalios K, Pippa N, Gatou M-A, Vagena I-A, Cela S, Pavlatou EA, Gazouli M, Efstathopoulos E. The role of nano-sensors in breath analysis for early and non-invasive disease diagnosis. Chemosensors. 2023;11(6): 317. https:\/\/doi.org\/10.3390\/chemosensors11060317.","journal-title":"Chemosensors"},{"key":"6675_CR56","doi-asserted-by":"publisher","DOI":"10.1088\/1752-7163\/ae4bfe","author":"S Radermacher","year":"2026","unstructured":"Radermacher S, Kreuer S, Maurer F, Hoffmann K, Bewersdorf N, Schulte J, Ule J, Volk T, Sessler DI, Bur C. A versatile ex-vivo model platform for detection of exhaled drugs using isolated perfused porcine lungs. J Breath Res. 2026. https:\/\/doi.org\/10.1088\/1752-7163\/ae4bfe.","journal-title":"J Breath Res"},{"key":"6675_CR57","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/00393630.2024.2339727","volume":"1\u20139","author":"G Eggert","year":"2024","unstructured":"Eggert G, Brieger O, Marschibois MS, Becker D, Bur C, Siebel KF, Grieb H. Sustainable and beneficial: pollutant absorption and relative humidity control in display cases by saturated salt solutions. Studies in Conservation. 2024;1\u20139:1. https:\/\/doi.org\/10.1080\/00393630.2024.2339727.","journal-title":"Studies in Conservation"},{"key":"6675_CR58","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1038\/s40494-025-02111-0202","volume":"13","author":"KF Siebel","year":"2025","unstructured":"Siebel KF, Grieb H, Brieger O, Pfeifer R, Bur C, Eggert G. Magnesium nitrate as sustainable solution for constant RH (53%) and pollutant absorption in display cases. npj Herit Sci. 2025;13:537. https:\/\/doi.org\/10.1038\/s40494-025-02111-0202.","journal-title":"npj Herit Sci"},{"key":"6675_CR59","doi-asserted-by":"publisher","first-page":"5679","DOI":"10.1007\/s00216-021-03554-7","volume":"413","author":"G Gauglitz","year":"2021","unstructured":"Gauglitz G. The new generation: quantum sensors. Anal Bioanal Chem. 2021;413:5679\u201380. https:\/\/doi.org\/10.1007\/s00216-021-03554-7.","journal-title":"Anal Bioanal Chem"},{"key":"6675_CR60","unstructured":"VDI\/VDE 3518 part 4:2025\u201304: Multigas sensors - Standardised test instructions and test gases for VOC detectors for indoor air quality measurement. 2025. https:\/\/www.dinmedia.de\/en\/technical-rule\/vdi-vde-3518-blatt-4\/385263233 . Accessed 26 Apr 2026."},{"key":"6675_CR61","doi-asserted-by":"publisher","first-page":"160018","DOI":"10.1038\/sdata.2016.18","volume":"3","author":"MD Wilkinson","year":"2016","unstructured":"Wilkinson MD, Dumontier M, Aalbersberg IJ, et al. The FAIR guiding principles for scientific data management and stewardship. Sci Data. 2016;3:160018. https:\/\/doi.org\/10.1038\/sdata.2016.18.","journal-title":"Sci Data"}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-026-06675-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00216-026-06675-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-026-06675-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T06:26:39Z","timestamp":1794032799000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00216-026-06675-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,20]]},"references-count":61,"journal-issue":{"issue":"23","published-print":{"date-parts":[[2026,12]]}},"alternative-id":["6675"],"URL":"https:\/\/doi.org\/10.1007\/s00216-026-06675-z","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,20]]},"assertion":[{"value":"27 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 July 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}