{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T05:29:07Z","timestamp":1786685347840,"version":"build-2736575974"},"reference-count":131,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T00:00:00Z","timestamp":1785283200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T00:00:00Z","timestamp":1785283200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100014132","name":"European Metrology Programme for Innovation and Research","doi-asserted-by":"publisher","award":["23FUN06 ProMET"],"award-info":[{"award-number":["23FUN06 ProMET"]}],"id":[{"id":"10.13039\/100014132","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Physikalisch-Technische Bundesanstalt (PTB)"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Anal Bioanal Chem"],"DOI":"10.1007\/s00216-026-06689-7","type":"journal-article","created":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T04:12:38Z","timestamp":1785298358000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The development and use of isotope dilution mass spectrometry methods for the quantification of target proteins in certified reference materials"],"prefix":"10.1007","author":[{"given":"Claudia","family":"Swart","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gavin","family":"O\u2019Connor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristian","family":"Arsene","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernd","family":"G\u00fcttler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luise","family":"Luckau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Milena","family":"Quaglia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karen","family":"Phinney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liesbet","family":"Deprez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guy","family":"Auclair","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qinde","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liqing","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent","family":"Delatour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amandine","family":"Boeuf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Bunk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,29]]},"reference":[{"issue":"2120","key":"6689_CR1","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1126\/science.82.2120.156","volume":"82","author":"R Schoenheimer","year":"1935","unstructured":"Schoenheimer R, Rittenberg D. Deuterium as an Indicator in the study of intermediary metabolism. Science. 1935;82(2120):156\u20137. https:\/\/doi.org\/10.1126\/science.82.2120.156.","journal-title":"Science"},{"key":"6689_CR2","unstructured":"Hevesy G, Paneth FA. A manual of radioactivity. Second edition. Oxford University Press, H Milford; 1926."},{"issue":"1","key":"6689_CR3","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1002\/mas.1280110104","volume":"11","author":"KG Heumann","year":"1992","unstructured":"Heumann KG. Isotope dilution mass spectrometry (IDMS) of the elements. Mass Spectrom Rev. 1992;11(1):41\u201367. https:\/\/doi.org\/10.1002\/mas.1280110104.","journal-title":"Mass Spectrom Rev"},{"key":"6689_CR4","doi-asserted-by":"publisher","unstructured":"Zeisler R, Murphy KE, Becker DA, Davis WC, Kelly WR, Long SE. Standard Reference Materials\u00ae (SRMs) for measurement of inorganic environmental contaminants. Anal Bioanal Chem. 2006;386(4):1137\u201351. https:\/\/doi.org\/10.1007\/s00216-006-0785-7.","DOI":"10.1007\/s00216-006-0785-7"},{"issue":"3","key":"6689_CR5","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1007\/s12647-010-0017-7","volume":"25","author":"J Vogl","year":"2010","unstructured":"Vogl J, Pritzkow W. Isotope dilution mass spectrometry \u2014 a primary method of measurement and its role for RM certification. Mapan. 2010;25(3):135\u201364. https:\/\/doi.org\/10.1007\/s12647-010-0017-7.","journal-title":"Mapan"},{"issue":"4","key":"6689_CR6","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1002\/mas.1280110402","volume":"11","author":"AP de Leenheer","year":"1992","unstructured":"de Leenheer AP, Thienpont LM. Applications of isotope dilution-mass spectrometry in clinical chemistry, pharmacokinetics, and toxicology. Mass Spectrom Rev. 1992;11(4):249\u2013307. https:\/\/doi.org\/10.1002\/mas.1280110402.","journal-title":"Mass Spectrom Rev"},{"key":"6689_CR7","doi-asserted-by":"publisher","unstructured":"White V E, Welch MJ, Sun T, Sniegoski LT, Schafter R, Hertz HS. The accurate determination of serum glucose by isotope dilution mass spectrometry\u2014two methods. Biomed Mass Spectrom. 1982;9(9):395\u2013405. https:\/\/doi.org\/10.1002\/bms.1200090907.","DOI":"10.1002\/bms.1200090907"},{"key":"6689_CR8","doi-asserted-by":"publisher","unstructured":"Cohen A, Hertz HS, Mandel J, Paule RC, Schaffer R, Sniegoski LT, u.\u00a0a. Total serum cholesterol by isotope dilution\/mass spectrometry: a candidate definitive method. [accessed 9 April 2026]. https:\/\/doi.org\/10.1093\/clinchem\/26.7.854.","DOI":"10.1093\/clinchem\/26.7.854"},{"key":"6689_CR9","doi-asserted-by":"publisher","unstructured":"Welch MJ, Cohen Alex, Hertz HS, Ng KJ, Schaffer Robert, Van Der Lijn Pieter, u.\u00a0a. Determination of serum creatinine by isotope dilution mass spectrometry as a candidate definitive method. Anal Chem. 1986;58(8):1681\u20135. https:\/\/doi.org\/10.1021\/ac00121a018.","DOI":"10.1021\/ac00121a018"},{"key":"6689_CR10","doi-asserted-by":"publisher","unstructured":"Siekmann L, Breuer H. Determination of cortisol in human plasma by isotope dilution-mass spectrometry. Definitive methods in clinical chemistry, I. Bd. 20. 1982;Clinical Chemistry and Laboratory Medicine (CCLM)20(12):883\u201392. https:\/\/doi.org\/10.1515\/cclm.1982.20.12.883.","DOI":"10.1515\/cclm.1982.20.12.883"},{"issue":"1","key":"6689_CR11","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1002\/mas.21497","volume":"36","author":"WD Lehmann","year":"2017","unstructured":"Lehmann WD. A timeline of stable isotopes and mass spectrometry in the life sciences. Mass Spectrom Rev. 2017;36(1):58\u201385.","journal-title":"Mass Spectrom Rev"},{"key":"6689_CR12","unstructured":"CCQM: Report of the 1st meeting. 1995. https:\/\/www.bipm.org\/documents\/20126\/40255962\/1st+meeting.pdf\/806db6f8-cf68-ee09-824b-4088d6df4347. Accessed 13 Mar 2026."},{"key":"6689_CR13","unstructured":"BIPM. Published CCQM-OAWG Key Comparisons. https:\/\/www.bipm.org\/en\/committees\/cc\/ccqm\/wg\/ccqm-oawg\/key-comparisons. Accessed 10 Apr 2026."},{"key":"6689_CR14","doi-asserted-by":"publisher","unstructured":"Wise SA, Phinney KW, Duewer DL, Sniegoski LT, Welch MJ, Pabello G. CCQM K6.2 determination of total cholesterol in human serum. Metrologia. 2018;55(1A):08011. https:\/\/doi.org\/10.1088\/0026-1394\/55\/1A\/08011.","DOI":"10.1088\/0026-1394\/55\/1A\/08011"},{"key":"6689_CR15","doi-asserted-by":"publisher","unstructured":"Wise SA, Phinney KW, Duewer DL, Sniegoski LT, Welch MJ, Pritchett J. CCQM-K11.2 determination of glucose in human serum and CCQM-K12.2 determination of creatinine in human serum. Metrologia. 2018;55(1A):08012. https:\/\/doi.org\/10.1088\/0026-1394\/55\/1A\/08012.","DOI":"10.1088\/0026-1394\/55\/1A\/08012"},{"issue":"1","key":"6689_CR16","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1021\/ac101950r","volume":"83","author":"KW Phinney","year":"2011","unstructured":"Phinney KW, Rimmer CA, Thomas JB, Sander LC, Sharpless KE, Wise SA. Isotope dilution liquid chromatography - mass spectrometry methods for fat- and water-soluble vitamins in nutritional formulations. Anal Chem. 2011;83(1):92\u20138. https:\/\/doi.org\/10.1021\/ac101950r.","journal-title":"Anal Chem"},{"issue":"18","key":"6689_CR17","doi-asserted-by":"publisher","first-page":"14607","DOI":"10.1021\/acs.jafc.6c01298","volume":"74","author":"CQ Burdette","year":"2026","unstructured":"Burdette CQ, Yen JH, Kuszak AJ, Wise SA. Value assignment of vitamin D and 25-hydroxyvitamin D in food-matrix standard reference materials (SRMs) using isotope dilution liquid chromatography\u2013tandem mass spectrometry (ID LC\u2013MS\/MS). J Agric Food Chem. 2026;74(18):14607\u201318. https:\/\/doi.org\/10.1021\/acs.jafc.6c01298.","journal-title":"J Agric Food Chem"},{"key":"6689_CR18","doi-asserted-by":"crossref","unstructured":"Zeleny R, Rummel A, Jansson D, Dorner BG. Challenges in the development of reference materials for protein toxins. In: Merkley ED, Herausgeber. ACS Symposium Series. Washington, DC: American Chemical Society; 2019;S:185\u2013202. https:\/\/pubs.acs.org\/doi\/abs\/10.1021\/bk-2019-1339.ch012.","DOI":"10.1021\/bk-2019-1339.ch012"},{"key":"6689_CR19","volume-title":"Versuch einer allgemeinen physiologischen Chemie","author":"GJ Mulder","year":"1844","unstructured":"Mulder GJ. Versuch einer allgemeinen physiologischen Chemie. Braunschweig: Friedrich Vieweg und Sohn; 1844."},{"issue":"1","key":"6689_CR20","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s13317-017-0097-2","volume":"8","author":"L Cinquanta","year":"2017","unstructured":"Cinquanta L, Fontana DE, Bizzaro N. Chemiluminescent immunoassay technology: what does it change in autoantibody detection? Autoimmun Highlights. 2017;8(1):9. https:\/\/doi.org\/10.1007\/s13317-017-0097-2.","journal-title":"Autoimmun Highlights"},{"key":"6689_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.talanta.2023.125529","volume":"270","author":"R Dong","year":"2024","unstructured":"Dong R, Yi N, Jiang D. Advances in single molecule arrays (SIMOA) for ultra-sensitive detection of biomolecules. Talanta. 2024;270:125529. https:\/\/doi.org\/10.1016\/j.talanta.2023.125529.","journal-title":"Talanta"},{"issue":"3","key":"6689_CR22","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1021\/jasms.0c00379","volume":"32","author":"NPM Smit","year":"2021","unstructured":"Smit NPM, Ruhaak LR, Romijn FPHTM, Pieterse MM, van der Burgt YEM, Cobbaert CM. The time has come for quantitative protein mass spectrometry tests that target unmet clinical needs. J Am Soc Mass Spectrom. 2021;32(3):636\u201347. https:\/\/doi.org\/10.1021\/jasms.0c00379.","journal-title":"J Am Soc Mass Spectrom"},{"key":"6689_CR23","doi-asserted-by":"publisher","unstructured":"Qualit\u00e4tssicherung laboratoriumsmedizinischer Untersuchungen \u2013 Rili-B\u00c4K. Dtsch \u00c4rztebl Online. 2023. https:\/\/doi.org\/10.3238\/arztebl.2023.rili_baek_QS_Labor.","DOI":"10.3238\/arztebl.2023.rili_baek_QS_Labor"},{"issue":"sup1","key":"6689_CR24","doi-asserted-by":"publisher","first-page":"S9","DOI":"10.1080\/13102818.2021.2011413","volume":"36","author":"S Wilson","year":"2022","unstructured":"Wilson S, Steele S, Adeli K. Innovative technological advancements in laboratory medicine: predicting the lab of the future. Biotechnol Biotechnol Equip. 2022;36(sup1):S9-21. https:\/\/doi.org\/10.1080\/13102818.2021.2011413.","journal-title":"Biotechnol Biotechnol Equip"},{"key":"6689_CR25","unstructured":"About. IFCC. https:\/\/ifcc.org\/about\/. Accessed 13 Mar 2026."},{"key":"6689_CR26","unstructured":"Dtsch \u00c4rztebl Int. 1971;31:7772\u201331."},{"key":"6689_CR27","unstructured":"Directive 98\/79\/EC of the european parliament and of the councIL of 27 October 1998 on in vitro diagnostic medical devices (OI L 331, 7.12.1998. p. 1\u201337)."},{"key":"6689_CR28","unstructured":"Regulation (EU) 2017\/746 of the european parliament and of the council of 5 April 2017 on in vitro diagnostic medical devices and repealing Directive 98\/79\/EC and Commission Decision 2010\/227\/EU, OJ L 117, 5.5.2017. p. 176\u2013332."},{"key":"6689_CR29","doi-asserted-by":"publisher","unstructured":"Reinmuth-Selzle K, Tchipilov T, Backes AT, Tscheuschner G, Tang K, Ziegler K. Determination of the protein content of complex samples by aromatic amino acid analysis, liquid chromatography-UV absorbance, and colorimetry. Anal Bioanal Chem. 2022;414(15):4457\u201370. https:\/\/doi.org\/10.1007\/s00216-022-03910-1.","DOI":"10.1007\/s00216-022-03910-1"},{"issue":"1","key":"6689_CR30","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.jim.2009.06.003","volume":"347","author":"AN Hoofnagle","year":"2009","unstructured":"Hoofnagle AN, Wener MH. The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry. J Immunol Methods. 2009;347(1):3\u201311. https:\/\/doi.org\/10.1016\/j.jim.2009.06.003.","journal-title":"J Immunol Methods"},{"issue":"8","key":"6689_CR31","doi-asserted-by":"publisher","first-page":"1200","DOI":"10.1515\/cclm-2019-1128","volume":"58","author":"M Panteghini","year":"2020","unstructured":"Panteghini M, Braga F. Implementation of metrological traceability in laboratory medicine: where we are and what is missing. Clin Chem Lab Med CCLM. 2020;58(8):1200\u20134. https:\/\/doi.org\/10.1515\/cclm-2019-1128.","journal-title":"Clin Chem Lab Med CCLM"},{"key":"6689_CR32","doi-asserted-by":"publisher","unstructured":"Josephs RD, Martos G, Li M, Wu L, Melanson JE, Quaglia M. Establishment of measurement traceability for peptide and protein quantification through rigorous purity assessment\u2014a review. Metrologia. 2019;56(4):044006. https:\/\/doi.org\/10.1088\/1681-7575\/ab27e5.","DOI":"10.1088\/1681-7575\/ab27e5"},{"key":"6689_CR33","doi-asserted-by":"publisher","unstructured":"Barber M, Bordoli RS, Sedgwick RD, Tyler AN. Fast atom bombardment of solids (F.A.B.): a new ion source for mass spectrometry. J Chem Soc Chem Commun. 1981;(7):325\u20137. https:\/\/doi.org\/10.1039\/C39810000325.","DOI":"10.1039\/C39810000325"},{"issue":"1\u20132","key":"6689_CR34","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/s0021-9673(97)00670-5","volume":"794","author":"DM Desiderio","year":"1998","unstructured":"Desiderio DM, Zhu X. Quantitative analysis of methionine enkephalin and beta-endorphin in the pituitary by liquid secondary ion mass spectrometry and tandem mass spectrometry. J Chromatogr A. 1998;794(1\u20132):85\u201396. https:\/\/doi.org\/10.1016\/s0021-9673(97)00670-5.","journal-title":"J Chromatogr A"},{"issue":"4926","key":"6689_CR35","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1126\/science.2675315","volume":"246","author":"JB Fenn","year":"1989","unstructured":"Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM. Electrospray ionization for mass spectrometry of large biomolecules. Science. 1989;246(4926):64\u201371. https:\/\/doi.org\/10.1126\/science.2675315.","journal-title":"Science"},{"key":"6689_CR36","doi-asserted-by":"crossref","unstructured":"Barr JR, Maggio VL, Patterson DG, Cooper GR, Henderson LO, Turner WE. Isotope dilution--mass spectrometric quantification of specific proteins: model application with apolipoprotein A-I. Clin Chem. 1996;42(10):1676\u201382.","DOI":"10.1093\/clinchem\/42.10.1676"},{"key":"6689_CR37","doi-asserted-by":"publisher","unstructured":"R\u00f6mmert AK, Ohlendorf R, Arsene C, Zhai R, Chu Z, Jin Y. CCQM-K177 - Determination of growth hormone in serum using isotope dilution mass spectrometry. Metrologia. 2025;62(1A):08026. https:\/\/doi.org\/10.1088\/0026-1394\/62\/1A\/08026.","DOI":"10.1088\/0026-1394\/62\/1A\/08026"},{"key":"6689_CR38","doi-asserted-by":"publisher","unstructured":"Jeong JS, Yim YH, Liu Q, Yong S, Liu H, Beltr\u00e3o P. Key comparison study on protein quantification: purity-assessed recombinant protein contents in buffer solution using insulin analogue. Metrologia. 2021;58(1A):08007. https:\/\/doi.org\/10.1088\/0026-1394\/58\/1A\/08007.","DOI":"10.1088\/0026-1394\/58\/1A\/08007"},{"key":"6689_CR39","doi-asserted-by":"publisher","unstructured":"Prohaska T, Irrgeher J, Benefield J, B\u00f6hlke JK, Chesson LA, Coplen TB. Standard atomic weights of the elements 2021 (IUPAC Technical Report). Pure Appl Chem. 2022;94(5):573\u2013600. https:\/\/doi.org\/10.1515\/pac-2019-0603.","DOI":"10.1515\/pac-2019-0603"},{"issue":"13","key":"6689_CR40","doi-asserted-by":"publisher","first-page":"4034","DOI":"10.1021\/ac050256t","volume":"77","author":"CF Harrington","year":"2005","unstructured":"Harrington CF, Vidler DS, Watts MJ, Hall JF. Potential for using isotopically altered metalloproteins in species-specific isotope dilution analysis of proteins by HPLC coupled to inductively coupled plasma mass spectrometry. Anal Chem. 2005;77(13):4034\u201341. https:\/\/doi.org\/10.1021\/ac050256t.","journal-title":"Anal Chem"},{"issue":"7","key":"6689_CR41","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1007\/s002160050625","volume":"359","author":"P De Bi\u00e8vre","year":"1997","unstructured":"De Bi\u00e8vre P, Peiser HS. Basic equations and uncertainties in isotope-dilution mass spectrometry for traceability to SI of values obtained by this primary method. Fresenius J Anal Chem. 1997;359(7):523\u20135. https:\/\/doi.org\/10.1007\/s002160050625.","journal-title":"Fresenius J Anal Chem"},{"key":"6689_CR42","doi-asserted-by":"publisher","unstructured":"Laeter JR de, B\u00f6hlke JK, Bi\u00e8vre PD, Hidaka H, Peiser HS, Rosman KJR. Atomic weights of the elements. Review 2000 (IUPAC Technical Report). Pure Appl Chem. 2003;75(6):683\u2013800. https:\/\/doi.org\/10.1351\/pac200375060683.","DOI":"10.1351\/pac200375060683"},{"issue":"6","key":"6689_CR43","doi-asserted-by":"publisher","first-page":"2127","DOI":"10.1039\/D6JA00070C","volume":"41","author":"A Pramann","year":"2026","unstructured":"Pramann A, Rienitz O. Blank correction in IDMS: possible pitfalls. J Anal At Spectrom. 2026;41(6):2127\u201336. https:\/\/doi.org\/10.1039\/D6JA00070C.","journal-title":"J Anal At Spectrom"},{"issue":"3","key":"6689_CR44","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1002\/rcm.5306","volume":"26","author":"J Vogl","year":"2012","unstructured":"Vogl J. Measurement uncertainty in single, double and triple isotope dilution mass spectrometry. Rapid Commun Mass Spectrom. 2012;26(3):275\u201381. https:\/\/doi.org\/10.1002\/rcm.5306.","journal-title":"Rapid Commun Mass Spectrom"},{"issue":"5","key":"6689_CR45","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1088\/0026-1394\/52\/5\/619","volume":"52","author":"HS Lee","year":"2015","unstructured":"Lee HS, Kim SH, Jeong JS, Lee YM, Yim YH. Sulfur-based absolute quantification of proteins using isotope dilution inductively coupled plasma mass spectrometry. Metrologia. 2015;52(5):619. https:\/\/doi.org\/10.1088\/0026-1394\/52\/5\/619.","journal-title":"Metrologia"},{"issue":"2","key":"6689_CR46","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1007\/s00216-007-1607-2","volume":"390","author":"C Rappel","year":"2008","unstructured":"Rappel C, Schauml\u00f6ffel D. The role of sulfur and sulfur isotope dilution analysis in quantitative protein analysis. Anal Bioanal Chem. 2008;390(2):605\u201315. https:\/\/doi.org\/10.1007\/s00216-007-1607-2.","journal-title":"Anal Bioanal Chem"},{"key":"6689_CR47","doi-asserted-by":"publisher","unstructured":"Busto ME del C, Oster C, Cuello-Nu\u00f1ez S, Deitrich CL, Raab A, Konopka A. Accurate quantification of selenoproteins in human plasma\/serum by isotope dilution ICP-MS: focus on selenoprotein P. J Anal At Spectrom. 2016;31(9):1904\u201312. https:\/\/doi.org\/10.1039\/C6JA00122J.","DOI":"10.1039\/C6JA00122J"},{"key":"6689_CR48","doi-asserted-by":"publisher","unstructured":"Coverdale JamesPC, Harrington CF, Solovyev N. Review: Advances in the accuracy and traceability of metalloprotein measurements using isotope dilution inductively coupled plasma mass spectrometry. Crit Rev Anal Chem. 2024;54(7):2259\u201376. https:\/\/doi.org\/10.1080\/10408347.2022.2162811.","DOI":"10.1080\/10408347.2022.2162811"},{"issue":"6","key":"6689_CR49","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1016\/j.jprot.2009.05.003","volume":"72","author":"J Bettmer","year":"2009","unstructured":"Bettmer J, Montes Bay\u00f3n M, Ruiz Encinar J, Fern\u00e1ndez S\u00e1nchez ML, Fern\u00e1ndez de la Campa M, Sanz Medel A. The emerging role of ICP-MS in proteomic analysis. J Proteomics. 2009;72(6):989\u20131005.","journal-title":"J Proteomics"},{"issue":"2","key":"6689_CR50","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1016\/j.ab.2008.02.010","volume":"376","author":"WI Burkitt","year":"2008","unstructured":"Burkitt WI, Pritchard C, Arsene C, Henrion A, Bunk D, O\u2019Connor G. Toward Syst\u00e8me International d\u2019Unit\u00e9-traceable protein quantification: from amino acids to proteins. Anal Biochem. 2008;376(2):242\u201351.","journal-title":"Anal Biochem"},{"key":"6689_CR51","doi-asserted-by":"publisher","unstructured":"Bunk DM, Lowenthal MS. Isotope dilution liquid chromatography-tandem mass spectrometry for quantitative amino acid analysis. In: Alterman MA, Hunziker P, Herausgeber. Amino acid analysis: methods and protocols. Totowa, NJ: Humana Press; 2012;S:29\u201338. https:\/\/doi.org\/10.1007\/978-1-61779-445-2_3.","DOI":"10.1007\/978-1-61779-445-2_3"},{"issue":"1","key":"6689_CR52","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.ab.2010.08.037","volume":"408","author":"A Mu\u00f1oz","year":"2011","unstructured":"Mu\u00f1oz A, Kral R, Schimmel H. Quantification of protein calibrants by amino acid analysis using isotope dilution mass spectrometry. Anal Biochem. 2011;408(1):124\u201331.","journal-title":"Anal Biochem"},{"issue":"1","key":"6689_CR53","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1007\/s00216-012-6097-1","volume":"404","author":"T Kinumi","year":"2012","unstructured":"Kinumi T, Goto M, Eyama S, Kato M, Kasama T, Takatsu A. Development of SI-traceable C-peptide certified reference material NMIJ CRM 6901-a using isotope-dilution mass spectrometry-based amino acid analyses. Anal Bioanal Chem. 2012;404(1):13\u201321. https:\/\/doi.org\/10.1007\/s00216-012-6097-1.","journal-title":"Anal Bioanal Chem"},{"issue":"8","key":"6689_CR54","doi-asserted-by":"publisher","first-page":"318","DOI":"10.4319\/lom.2005.3.318","volume":"3","author":"K Kaiser","year":"2005","unstructured":"Kaiser K, Benner R. Hydrolysis-induced racemization of amino acids. Limnol Oceanogr Methods. 2005;3(8):318\u201325. https:\/\/doi.org\/10.4319\/lom.2005.3.318.","journal-title":"Limnol Oceanogr Methods"},{"issue":"13","key":"6689_CR55","doi-asserted-by":"publisher","first-page":"5437","DOI":"10.1021\/ja00039a072","volume":"114","author":"ES Eberhardt","year":"1992","unstructured":"Eberhardt ES, Loh SN, Hinck AP, Raines RT. Solvent effects on the energetics of prolyl peptide bond isomerization. J Am Chem Soc. 1992;114(13):5437\u20139. https:\/\/doi.org\/10.1021\/ja00039a072.","journal-title":"J Am Chem Soc"},{"key":"6689_CR56","doi-asserted-by":"crossref","unstructured":"Li J, Li J, He H, Li M, Ma P, Song D. Comparative study for purity assessment of recombinant human growth hormone using mass balance approach and amino acid-based isotope dilution mass spectrometry. Microchem J. 2024;205:111144.","DOI":"10.1016\/j.microc.2024.111144"},{"issue":"21","key":"6689_CR57","doi-asserted-by":"publisher","first-page":"4907","DOI":"10.1007\/s00216-025-06007-7","volume":"417","author":"J Li","year":"2025","unstructured":"Li J, Li J, Li M, Ma P, Song D, Fei Q. Quantification of parathyroid hormone in high-purity materials by two isotope dilution mass spectrometry methods. Anal Bioanal Chem. 2025;417(21):4907\u201316.","journal-title":"Anal Bioanal Chem"},{"key":"6689_CR58","doi-asserted-by":"publisher","DOI":"10.1016\/j.foodchem.2022.132674","volume":"385","author":"J Yan","year":"2022","unstructured":"Yan J, Wang M, Yang M, Zhou J, Xue X, Wang T. Study of SI-traceable purity assessment of bovine lactoferrin using mass balance approach and amino acid-based isotope dilution liquid chromatography-mass spectrometry. Food Chem. 2022;385:132674.","journal-title":"Food Chem"},{"key":"6689_CR59","doi-asserted-by":"publisher","unstructured":"Hoofnagle AN, Whiteaker JR, Carr SA, Kuhn E, Liu T, Massoni SA. Recommendations for the generation, quantification, storage, and handling of peptides used for mass spectrometry\u2013based assays. Clin Chem. 2016;62(1):48\u201369. https:\/\/doi.org\/10.1373\/clinchem.2015.250563.","DOI":"10.1373\/clinchem.2015.250563"},{"issue":"6","key":"6689_CR60","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1002\/mas.21542","volume":"37","author":"F Calder\u00f3n-Celis","year":"2018","unstructured":"Calder\u00f3n-Celis F, Encinar JR, Sanz-Medel A. Standardization approaches in absolute quantitative proteomics with mass spectrometry. Mass Spectrom Rev. 2018;37(6):715\u201337. https:\/\/doi.org\/10.1002\/mas.21542.","journal-title":"Mass Spectrom Rev"},{"issue":"9","key":"6689_CR61","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1074\/mcp.O112.017145","volume":"11","author":"CM Shuford","year":"2012","unstructured":"Shuford CM, Sederoff RR, Chiang VL, Muddiman DC. Peptide production and decay rates affect the quantitative accuracy of protein cleavage isotope dilution mass spectrometry (PC-IDMS)*. Mol Cell Proteomics. 2012;11(9):814\u201323. https:\/\/doi.org\/10.1074\/mcp.O112.017145.","journal-title":"Mol Cell Proteomics"},{"key":"6689_CR62","doi-asserted-by":"publisher","unstructured":"Arsene CG, Ohlendorf R, Burkitt W, Pritchard C, Henrion A, O\u2019Connor G. Protein quantification by isotope dilution mass spectrometry of proteolytic fragments: cleavage rate and accuracy. Anal Chem. 2008;80(11):4154\u201360. https:\/\/doi.org\/10.1021\/ac7024738.","DOI":"10.1021\/ac7024738"},{"key":"6689_CR63","doi-asserted-by":"publisher","unstructured":"Carr SA, Abbatiello SE, Ackermann BL, Borchers C, Domon B, Deutsch EW. Targeted peptide measurements in biology and medicine: best practices for mass spectrometry-based assay development using a fit-for-purpose approach. Mol Cell Proteomics MCP. 2014;13(3):907\u201317. https:\/\/doi.org\/10.1074\/mcp.M113.036095.","DOI":"10.1074\/mcp.M113.036095"},{"issue":"2","key":"6689_CR64","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1021\/pr015516b","volume":"1","author":"R Zhang","year":"2002","unstructured":"Zhang R, Regnier FE. Minimizing resolution of isotopically coded peptides in comparative proteomics. J Proteome Res. 2002;1(2):139\u201347. https:\/\/doi.org\/10.1021\/pr015516b.","journal-title":"J Proteome Res"},{"issue":"1","key":"6689_CR65","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6501\/ac2fe9","volume":"33","author":"G Martos","year":"2021","unstructured":"Martos G, Westwood S, Bedu M, Josephs RD, Wielgosz R. qNMR characterization of potential peptide calibrators for isotope dilution LC\u2013MS quantification of a SARS-CoV-2 IgG monoclonal antibody. Meas Sci Technol. 2021;33(1):014003. https:\/\/doi.org\/10.1088\/1361-6501\/ac2fe9.","journal-title":"Meas Sci Technol"},{"issue":"11","key":"6689_CR66","doi-asserted-by":"publisher","first-page":"5145","DOI":"10.1021\/pr300273g","volume":"11","author":"T Glatter","year":"2012","unstructured":"Glatter T, Ludwig C, Ahrn\u00e9 E, Aebersold R, Heck AJR, Schmidt A. Large-scale quantitative assessment of different in-solution protein digestion protocols reveals superior cleavage efficiency of tandem Lys-C\/trypsin proteolysis over trypsin digestion. J Proteome Res. 2012;11(11):5145\u201356. https:\/\/doi.org\/10.1021\/pr300273g.","journal-title":"J Proteome Res"},{"key":"6689_CR67","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.aca.2014.07.041","volume":"844","author":"SC Diaz","year":"2014","unstructured":"Diaz SC, Encinar JR, Alonso JIG. Evaluation of online carbon isotope dilution mass spectrometry for the purity assessment of synthetic peptide standards. Anal Chim Acta. 2014;844:48\u201353.","journal-title":"Anal Chim Acta"},{"key":"6689_CR68","doi-asserted-by":"publisher","unstructured":"Zhou D, Wang X, Zou J, Song J, Su P, Yang Y. Determination of [Glu1]-fibrinopeptide B purity by gas chromatography \u2013 isotope dilution mass spectrometry. Anal Methods. 2024;16(12):1741\u20137. https:\/\/doi.org\/10.1039\/D3AY02114A.","DOI":"10.1039\/D3AY02114A"},{"key":"6689_CR69","doi-asserted-by":"publisher","unstructured":"Frank C, Brauckmann C, Palos M, Arsene CG, Neukammer J, Del Castillo Busto ME. Comparison of potential higher order reference methods for total haemoglobin quantification\u2014an interlaboratory study. Anal Bioanal Chem. 2017;409(9):2341\u201351. https:\/\/doi.org\/10.1007\/s00216-016-0176-7.","DOI":"10.1007\/s00216-016-0176-7"},{"key":"6689_CR70","doi-asserted-by":"crossref","unstructured":"Song J, Zhou D, Wu L, Wang Z, Jiang X, Su P. A potential primary method for peptide purity analysis by gas chromatography-isotope dilution infrared spectrometry. Anal Bioanal Chem. 2023;415(19):4795\u2013804.","DOI":"10.1007\/s00216-023-04772-x"},{"key":"6689_CR71","doi-asserted-by":"crossref","unstructured":"Little RR, Wielgosz RI, Josephs R, Kinumi T, Takatsu A, Li H. Implementing a reference measurement system for C-peptide: successes and lessons learned. Clin Chem. 2017;63(9):1447\u201356.","DOI":"10.1373\/clinchem.2016.269274"},{"issue":"12","key":"6689_CR72","doi-asserted-by":"publisher","first-page":"3085","DOI":"10.1007\/s00216-024-05258-0P","volume":"416","author":"S Ma","year":"2024","unstructured":"Ma S, He R, Jiang T, Hu Z, Ye Z, Mi W. Development of an isotope dilution mass spectrometry assay for the quantification of insulin based on signature peptide analysis. Anal Bioanal Chem. 2024;416(12):3085\u201396. https:\/\/doi.org\/10.1007\/s00216-024-05258-0P.","journal-title":"Anal Bioanal Chem"},{"key":"6689_CR73","doi-asserted-by":"crossref","unstructured":"Wu L, Takatsu A, Park SR, Yang B, Yang H, Kinumi T. Development and co-validation of porcine insulin certified reference material by high-performance liquid chromatography\u2013isotope dilution mass spectrometry. Anal Bioanal Chem. 2015;407(11):3125\u201335.","DOI":"10.1007\/s00216-014-8385-4"},{"key":"6689_CR74","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchromb.2024.124112","volume":"1240","author":"J Wu","year":"2024","unstructured":"Wu J, Liu J, Sun H, Xing T, Liu X, Song D. Absolute quantification methods for prostate-specific antigen by isotope-dilution mass spectrometry. J Chromatogr B. 2024;1240:124112.","journal-title":"J Chromatogr B"},{"key":"6689_CR75","doi-asserted-by":"crossref","unstructured":"Liu Z, Zhao X, Liu Y, Shi L, Wu L, Yuan H. Development of an insulin-like growth factor-1 certified reference material by SI-traceable isotope-dilution mass spectrometry. Talanta. 2024;273:125812.","DOI":"10.1016\/j.talanta.2024.125812"},{"key":"6689_CR76","doi-asserted-by":"crossref","unstructured":"Zhu M, Li J, Chu Z, Li L, Meng B, Zhao Y. Development of cancer biomarker heat shock protein 90\u03b1 certified reference material using two different isotope dilution mass spectrometry techniques. Anal Bioanal Chem. 2024;416(4):913\u201323.","DOI":"10.1007\/s00216-023-05079-7"},{"key":"6689_CR77","doi-asserted-by":"crossref","unstructured":"Yan R, Wang L, Ji H, Pei D, Chen X, Cheng Z, Wei W. Characterization and development of an interleukin-6 reference material by SI-traceable isotope-dilution mass spectrometry. J Chromatogr B. 2026; 1275: 125002.","DOI":"10.1016\/j.jchromb.2026.125002"},{"key":"6689_CR78","doi-asserted-by":"crossref","unstructured":"Yu Z, Wang J, Xia W, Wang Y, Zhang Y, Tang J. The development of an isotope dilution mass spectrometry method for interleukin-6 quantification. Int J Mol Sci. 2024;25(12):6777.","DOI":"10.3390\/ijms25126777"},{"key":"6689_CR79","doi-asserted-by":"crossref","unstructured":"Bao C, Wang J, Xia W, Yang K, Shi X, Yang X. Absolute quantification of tumor necrosis factor-alpha by isotope dilution mass spectrometry. Front Chem. 2026;13:1667885.","DOI":"10.3389\/fchem.2025.1667885"},{"issue":"10","key":"6689_CR80","doi-asserted-by":"publisher","first-page":"4146","DOI":"10.1021\/acs.analchem.1c03061","volume":"94","author":"HH Huynh","year":"2022","unstructured":"Huynh HH, Delatour V, Derbez-Morin M, Liu Q, Boeuf A, Vinh J. Candidate high-resolution mass spectrometry-based reference method for the quantification of procalcitonin in human serum using a characterized recombinant protein as a primary calibrator. Anal Chem. 2022;94(10):4146\u201354. https:\/\/doi.org\/10.1021\/acs.analchem.1c03061.","journal-title":"Anal Chem"},{"key":"6689_CR81","doi-asserted-by":"crossref","unstructured":"Pierce-Ruiz C, Santana WI, Sutton WJ, Fischler DA, Cooper HC, Marc LR. Quantification of SARS-CoV-2 spike and nucleocapsid proteins using isotope dilution tandem mass spectrometry. Vaccine. 2021;39(36):5106\u201315.","DOI":"10.1016\/j.vaccine.2021.07.066"},{"issue":"10","key":"6689_CR82","doi-asserted-by":"publisher","first-page":"2423","DOI":"10.1007\/s00216-024-05205-z","volume":"416","author":"G Martos","year":"2024","unstructured":"Martos G, Bedu M, Josephs R, Westwood S, Wielgosz R. Quantification of SARS-CoV-2 monoclonal IgG mass fraction by isotope dilution mass spectrometry. Anal Bioanal Chem. 2024;416(10):2423\u201337.","journal-title":"Anal Bioanal Chem"},{"key":"6689_CR83","doi-asserted-by":"publisher","unstructured":"Shuford CM, Walters JJ, Holland PM, Sreenivasan U, Askari N, Ray K. Absolute protein quantification by mass spectrometry: not as simple as advertised. Anal Chem. 2017;89(14):7406\u201315. https:\/\/doi.org\/10.1021\/acs.analchem.7b00858.","DOI":"10.1021\/acs.analchem.7b00858"},{"key":"6689_CR84","doi-asserted-by":"publisher","unstructured":"Oeckl P, Steinacker P, Otto M. Comparison of internal standard approaches for SRM analysis of alpha-synuclein in cerebrospinal fluid. J Proteome Res. 2018;17(1):516\u201323. https:\/\/doi.org\/10.1021\/acs.jproteome.7b00660.","DOI":"10.1021\/acs.jproteome.7b00660"},{"key":"6689_CR85","doi-asserted-by":"publisher","unstructured":"Asicioglu M, Swart C, Saban E, Yurek E, Karaguler NG, Oztug M. Comparative evaluation of peptide vs. protein-based calibration for quantification of cardiac troponin I using ID-LC-MS\/MS. Clin Chem Lab Med CCLM. 2025;63(5):1016\u201330. https:\/\/doi.org\/10.1515\/cclm-2024-0999.","DOI":"10.1515\/cclm-2024-0999"},{"key":"6689_CR86","doi-asserted-by":"publisher","unstructured":"Nouri-Nigjeh E, Zhang M, Ji T, Yu H, An B, Duan X. Effects of calibration approaches on the accuracy for LC\u2013MS targeted quantification of therapeutic protein. Anal Chem. 2014;86(7):3575\u201384. https:\/\/doi.org\/10.1021\/ac5001477.","DOI":"10.1021\/ac5001477"},{"issue":"3","key":"6689_CR87","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1093\/clinchem\/hvaa256","volume":"67","author":"AN Hoofnagle","year":"2021","unstructured":"Hoofnagle AN, Cobbaert CM, Delatour V, Kelleher NL, Lowenthal MS, Shuford CM. Should LC-MS\/MS be the reference measurement procedure to determine protein concentrations in human samples? Clin Chem. 2021;67(3):466\u201371. https:\/\/doi.org\/10.1093\/clinchem\/hvaa256.","journal-title":"Clin Chem"},{"issue":"2","key":"6689_CR88","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1039\/C9MO00154A","volume":"16","author":"KA Cupp-Sutton","year":"2020","unstructured":"Cupp-Sutton KA, Wu S. High-throughput quantitative top-down proteomics. Mol Omics. 2020;16(2):91\u20139. https:\/\/doi.org\/10.1039\/C9MO00154A.","journal-title":"Mol Omics"},{"key":"6689_CR89","doi-asserted-by":"publisher","unstructured":"Torma AF, Groves K, Biesenbruch S, Mussell C, Reid A, Ellison S. A candidate liquid chromatography mass spectrometry reference method for the quantification of the cardiac marker 1-32 B-type natriuretic peptide. Clin Chem Lab Med CCLM. 2017;55(9):1397\u2013406. https:\/\/doi.org\/10.1515\/cclm-2016-1054.","DOI":"10.1515\/cclm-2016-1054"},{"key":"6689_CR90","doi-asserted-by":"publisher","unstructured":"Pritchard C, Groves KJ, Biesenbruch S, O\u2019Connor G, Ashcroft AE, Arsene C. Quantification of human growth hormone in serum with a labeled protein as an internal standard: essential considerations. Anal Chem. 2014;86(13):6525\u201332. https:\/\/doi.org\/10.1021\/ac501032q.","DOI":"10.1021\/ac501032q"},{"issue":"2","key":"6689_CR91","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1586\/14789450.4.2.175","volume":"4","author":"BL Ackermann","year":"2007","unstructured":"Ackermann BL, Berna MJ. Coupling immunoaffinity techniques with MS for quantitative analysis of low-abundance protein biomarkers. Expert Rev Proteomics. 2007;4(2):175\u201386. https:\/\/doi.org\/10.1586\/14789450.4.2.175.","journal-title":"Expert Rev Proteomics"},{"key":"6689_CR92","unstructured":"ISO 15194:2009: In vitro diagnostic medical devices \u2014 measurement of quantities in samples of biological origin \u2014 requirements for certified reference materials and the content of supporting documentation."},{"key":"6689_CR93","unstructured":"ISO 15193:2009: In vitro diagnostic medical devices \u2013 measurement of quantities in samples of biological origin \u2013 requirements for content and presentation of reference measurement procedures."},{"key":"6689_CR94","unstructured":"ISO 17511:2020: In vitro diagnostic medical devices \u2014 requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples."},{"key":"6689_CR95","doi-asserted-by":"publisher","unstructured":"Zegers I, Beetham R, Keller T, Sheldon J, Bullock D, MacKenzie F. The importance of commutability of reference materials used as calibrators: the example of ceruloplasmin. Clin Chem. 2013;59(9):1322\u20139. https:\/\/doi.org\/10.1373\/clinchem.2012.201954.","DOI":"10.1373\/clinchem.2012.201954"},{"issue":"4","key":"6689_CR96","doi-asserted-by":"publisher","first-page":"59","DOI":"10.3390\/scipharm93040059","volume":"93","author":"M Radenkovi\u0107","year":"2025","unstructured":"Radenkovi\u0107 M. Biopharmaceuticals\u2014current information and new challenges. Sci Pharm. 2025;93(4):59. https:\/\/doi.org\/10.3390\/scipharm93040059.","journal-title":"Sci Pharm"},{"issue":"2","key":"6689_CR97","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1016\/j.xphs.2024.12.011","volume":"114","author":"RK Gupta","year":"2025","unstructured":"Gupta RK. The vital role of biological standardization in ensuring efficacy and safety of biological products \u2013 historical perspectives. J Pharm Sci. 2025;114(2):690\u2013700. https:\/\/doi.org\/10.1016\/j.xphs.2024.12.011.","journal-title":"J Pharm Sci"},{"issue":"2","key":"6689_CR98","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1007\/s00216-025-06036-2","volume":"418","author":"DR Cunha","year":"2026","unstructured":"Cunha DR, Quinaz MB, Segundo MA. Biopharmaceutical analysis \u2014 current analytical challenges, limitations, and perspectives. Anal Bioanal Chem. 2026;418(2):373\u201394. https:\/\/doi.org\/10.1007\/s00216-025-06036-2.","journal-title":"Anal Bioanal Chem"},{"key":"6689_CR99","unstructured":"NIBSC - WHO international standards. https:\/\/nibsc.org\/products\/brm_product_catalogue\/who_standards.aspx. Accessed 13 May 2026."},{"issue":"8","key":"6689_CR100","doi-asserted-by":"publisher","first-page":"2067","DOI":"10.1007\/s00216-017-0844-2","volume":"410","author":"JE Schiel","year":"2018","unstructured":"Schiel JE, Turner A. The NISTmAb Reference Material 8671 lifecycle management and quality plan. Anal Bioanal Chem. 2018;410(8):2067\u201378. https:\/\/doi.org\/10.1007\/s00216-017-0844-2.","journal-title":"Anal Bioanal Chem"},{"key":"6689_CR101","unstructured":"NIST Monoclonal Antibody Reference Material 8671. NIST.\u00a0https:\/\/www.nist.gov\/programs-projects\/nist-monoclonal-antibody-reference-material-8671. Accessed 13 May 2026."},{"key":"6689_CR102","unstructured":"Commission Regulation (EC) No 41\/2009 of 20 January 2009 concerning the composition and labelling of foodstuffs suitable for people intolerant to gluten. OJ L 2009. http:\/\/data.europa.eu\/eli\/reg\/2009\/41\/oj. Accessed 31 May 2026"},{"key":"6689_CR103","unstructured":"Regulation (EU) No 1169\/2011 of the European Parliament and of the Council of 25 October 2011 on the provision of food information to consumers, amending Regulations (EC) No 1924\/2006 and (EC) No 1925\/2006 of the European Parliament and of the Council, and repealing Commission Directive 87\/250\/EEC, Council Directive 90\/496\/EEC, Commission Directive 1999\/10\/EC, Directive 2000\/13\/EC of the European Parliament and of the Council, Commission Directives 2002\/67\/EC and 2008\/5\/EC and Commission Regulation (EC) No 608\/2004 Text with EEA relevance. OJ L. 25. Oktober 2011. Verf\u00fcgbar unter: http:\/\/data.europa.eu\/eli\/reg\/2011\/1169\/oj. Accessed 31 May 2026"},{"key":"6689_CR104","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.foodchem.2017.04.092","volume":"234","author":"M Rzychon","year":"2017","unstructured":"Rzychon M, Broh\u00e9e M, Cordeiro F, Haraszi R, Ulberth F, O\u2019Connor G. The feasibility of harmonizing gluten ELISA measurements. Food Chem. 2017;234:144\u201354. https:\/\/doi.org\/10.1016\/j.foodchem.2017.04.092.","journal-title":"Food Chem"},{"key":"6689_CR105","doi-asserted-by":"publisher","unstructured":"Bugyi Z, T\u00f6r\u00f6k K, Hajas L, Adonyi Z, Poms RE, Popping B. Development of incurred reference material for improving conditions of gluten quantification. J AOAC Int. 2012;95(2):382\u20137. https:\/\/doi.org\/10.5740\/jaoacint.SGE_Bugyi.","DOI":"10.5740\/jaoacint.SGE_Bugyi"},{"key":"6689_CR106","unstructured":"Codex Alimentarius. (1979 rev. 2008). Codex standard for foods for special dietary use for persons intolerant to gluten. 2008. (CODEX STAN 118\u20131979)."},{"issue":"5","key":"6689_CR107","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1094\/CCHEM-11-16-0266-R","volume":"94","author":"MJ Mart\u00ednez-Esteso","year":"2017","unstructured":"Mart\u00ednez-Esteso MJ, Broh\u00e9e M, N\u00f8rgaard J, O\u2019Connor G. Label-free proteomic analysis of wheat gluten proteins and their immunoreactivity to ELISA antibodies. Cereal Chem. 2017;94(5):820\u20136. https:\/\/doi.org\/10.1094\/CCHEM-11-16-0266-R.","journal-title":"Cereal Chem"},{"key":"6689_CR108","doi-asserted-by":"publisher","unstructured":"Taylor SL, Baumert JL, Kruizinga AG, Remington BC, Crevel RWR, Brooke-Taylor S. Establishment of reference doses for residues of allergenic foods: report of the VITAL Expert Panel. Food Chem Toxicol. 2014;63:9\u201317. https:\/\/doi.org\/10.1016\/j.fct.2013.10.032.","DOI":"10.1016\/j.fct.2013.10.032"},{"key":"6689_CR109","doi-asserted-by":"publisher","unstructured":"Holzhauser T, Johnson P, Hindley JP, O\u2019Connor G, Chan CH, Costa J. Are current analytical methods suitable to verify VITAL\u00ae 2.0\/3.0 allergen reference doses for EU allergens in foods? Food Chem Toxicol. 2020;145:111709. https:\/\/doi.org\/10.1016\/j.fct.2020.111709.","DOI":"10.1016\/j.fct.2020.111709"},{"key":"6689_CR110","doi-asserted-by":"publisher","DOI":"10.1016\/j.foodchem.2023.136391","volume":"424","author":"E Cubero-Leon","year":"2023","unstructured":"Cubero-Leon E, Emons H, O\u2019Connor G, N\u00f8rgaard J, Robouch P. Food allergen analysis: considerations for establishing a reference measurement system to implement EU legislation. Food Chem. 2023;424:136391. https:\/\/doi.org\/10.1016\/j.foodchem.2023.136391.","journal-title":"Food Chem"},{"issue":"16","key":"6689_CR111","doi-asserted-by":"publisher","first-page":"3463","DOI":"10.1007\/s00216-019-01816-z","volume":"411","author":"C Nitride","year":"2019","unstructured":"Nitride C, N\u00f8rgaard J, Omar J, Emons H, Esteso MJM, O\u2019Connor G. An assessment of the impact of extraction and digestion protocols on multiplexed targeted protein quantification by mass spectrometry for egg and milk allergens. Anal Bioanal Chem. 2019;411(16):3463\u201375. https:\/\/doi.org\/10.1007\/s00216-019-01816-z.","journal-title":"Anal Bioanal Chem"},{"key":"6689_CR112","doi-asserted-by":"publisher","unstructured":"Martinez-Esteso MJ, O\u2019Connor G, N\u00f8rgaard J, Breidbach A, Broh\u00e9e M, Cubero-Leon E. A reference method for determining the total allergenic protein content in a processed food: the case of milk in cookies as proof of concept. Anal Bioanal Chem. 2020;412(30):8249\u201367. https:\/\/doi.org\/10.1007\/s00216-020-02959-0.","DOI":"10.1007\/s00216-020-02959-0"},{"key":"6689_CR113","doi-asserted-by":"publisher","unstructured":"Cordeiro F, Cubero-Leon E, N\u00f8rgaard J, Martinez-Esteso MJ, Broh\u00e9e M, Breidbach A. Total cow\u2019s milk protein in cookies: the first interlaboratory comparison with a well-defined measurand fit for food allergen risk assessment. Accreditation Qual Assur. 2021;26(3):177\u201381. https:\/\/doi.org\/10.1007\/s00769-021-01470-y.","DOI":"10.1007\/s00769-021-01470-y"},{"key":"6689_CR114","doi-asserted-by":"publisher","unstructured":"Holcombe G, Walker MJ, Singh M, Gray K, Cowen S, Ellison SLR. Clinically and industrially relevant incurred reference materials to improve analysis of food allergens, milk, egg, almond, hazelnut and walnut. Food Chem. 2024;434:137391. https:\/\/doi.org\/10.1016\/j.foodchem.2023.137391.","DOI":"10.1016\/j.foodchem.2023.137391"},{"key":"6689_CR115","doi-asserted-by":"publisher","unstructured":"Campbell JJ, Almond N, Bae YK, Bhuller R, Briones A, Cho SJ. Standards and metrology for viral vectors as molecular tools: outcomes from a CCQM Workshop. Biologics. 2024;4(2):187\u2013201. https:\/\/doi.org\/10.3390\/biologics4020013.","DOI":"10.3390\/biologics4020013"},{"key":"6689_CR116","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpba.2023.115696","volume":"236","author":"J Castel","year":"2023","unstructured":"Castel J, Delaux S, Hernandez-Alba O, Cianf\u00e9rani S. Recent advances in structural mass spectrometry methods in the context of biosimilarity assessment: from sequence heterogeneities to higher order structures. J Pharm Biomed Anal. 2023;236:115696. https:\/\/doi.org\/10.1016\/j.jpba.2023.115696.","journal-title":"J Pharm Biomed Anal"},{"key":"6689_CR117","doi-asserted-by":"publisher","unstructured":"Castel J, Botzanowski T, Brooks I, Frechard A, Bey G, Schroeter M. Deciphering molecular determinants of GPBAR1-Gs protein interactions by HDX-MS and cryo-EM. Sci Rep. 2025;15(1):31517. https:\/\/doi.org\/10.1038\/s41598-025-16529-w.","DOI":"10.1038\/s41598-025-16529-w"},{"key":"6689_CR118","doi-asserted-by":"publisher","unstructured":"Masson GR, Burke JE, Ahn NG, Anand GS, Borchers C, Brier S. Recommendations for performing, interpreting and reporting hydrogen deuterium exchange mass spectrometry (HDX-MS) experiments. Nat Methods. 2019;16(7):595\u2013602. https:\/\/doi.org\/10.1038\/s41592-019-0459-y.","DOI":"10.1038\/s41592-019-0459-y"},{"issue":"15","key":"6689_CR119","doi-asserted-by":"publisher","first-page":"8865","DOI":"10.1021\/acs.analchem.8b00912","volume":"90","author":"O Hernandez-Alba","year":"2018","unstructured":"Hernandez-Alba O, Wagner-Rousset E, Beck A, Cianf\u00e9rani S. Native mass spectrometry, ion mobility, and collision-induced unfolding for conformational characterization of IgG4 monoclonal antibodies. Anal Chem. 2018;90(15):8865\u201372. https:\/\/doi.org\/10.1021\/acs.analchem.8b00912.","journal-title":"Anal Chem"},{"key":"6689_CR120","doi-asserted-by":"publisher","unstructured":"Desligni\u00e8re E, Ollivier S, Ehkirch A, Martelet A, Ropartz D, Lechat N. Combination of IM-based approaches to unravel the coexistence of two conformers on a therapeutic multispecific mAb. Anal Chem. 2022;94(22):7981\u20139. https:\/\/doi.org\/10.1021\/acs.analchem.2c00928.","DOI":"10.1021\/acs.analchem.2c00928"},{"key":"6689_CR121","doi-asserted-by":"publisher","unstructured":"Eldrid C, Ben-Younis A, Ujma J, Britt H, Cragnolini T, Kalfas S. Cyclic ion mobility\u2013collision activation experiments elucidate protein behavior in the gas phase. J Am Soc Mass Spectrom. 2021;32(6):1545\u201352. https:\/\/doi.org\/10.1021\/jasms.1c00018.","DOI":"10.1021\/jasms.1c00018"},{"issue":"23","key":"6689_CR122","doi-asserted-by":"publisher","first-page":"3893","DOI":"10.1002\/rcm.3794","volume":"22","author":"W Burkitt","year":"2008","unstructured":"Burkitt W, O\u2019Connor G. Assessment of the repeatability and reproducibility of hydrogen\/deuterium exchange mass spectrometry measurements. Rapid Commun Mass Spectrom. 2008;22(23):3893\u2013901. https:\/\/doi.org\/10.1002\/rcm.3794.","journal-title":"Rapid Commun Mass Spectrom"},{"issue":"15","key":"6689_CR123","doi-asserted-by":"publisher","first-page":"7205","DOI":"10.1021\/ac400927s","volume":"85","author":"C Pritchard","year":"2013","unstructured":"Pritchard C, O\u2019Connor G, Ashcroft AE. The role of ion mobility spectrometry-mass spectrometry in the analysis of protein reference standards. Anal Chem. 2013;85(15):7205\u201312. https:\/\/doi.org\/10.1021\/ac400927s.","journal-title":"Anal Chem"},{"issue":"8","key":"6689_CR124","doi-asserted-by":"publisher","first-page":"7500","DOI":"10.1021\/acs.chemrev.1c00786","volume":"122","author":"L Piersimoni","year":"2022","unstructured":"Piersimoni L, Kastritis PL, Arlt C, Sinz A. Cross-linking mass spectrometry for investigating protein conformations and protein\u2013protein interactions\u2500a method for all seasons. Chem Rev. 2022;122(8):7500\u201331. https:\/\/doi.org\/10.1021\/acs.chemrev.1c00786.","journal-title":"Chem Rev"},{"issue":"9","key":"6689_CR125","doi-asserted-by":"publisher","first-page":"3780","DOI":"10.1021\/acs.jproteome.4c00088","volume":"23","author":"M Shi","year":"2024","unstructured":"Shi M, Huang C, Chen R, Chen DDY, Yan B. A new evaluation metric for quantitative accuracy of LC\u2013MS\/MS-based proteomics with data-independent acquisition. J Proteome Res. 2024;23(9):3780\u201390. https:\/\/doi.org\/10.1021\/acs.jproteome.4c00088.","journal-title":"J Proteome Res"},{"key":"6689_CR126","doi-asserted-by":"publisher","unstructured":"Hartl J, Kurth F, Kappert K, Horst D, M\u00fclleder M, Hartmann G. Quantitative protein biomarker panels: a path to improved clinical practice through proteomics. EMBO Mol Med. 2023;15(4):EMMM202216061. https:\/\/doi.org\/10.15252\/emmm.202216061.","DOI":"10.15252\/emmm.202216061"},{"issue":"5","key":"6689_CR127","doi-asserted-by":"publisher","DOI":"10.1007\/s11250-024-04037-4","volume":"56","author":"M Adnane","year":"2024","unstructured":"Adnane M, de Almeida AM, Chapwanya A. Unveiling the power of proteomics in advancing tropical animal health and production. Trop Anim Health Prod. 2024;56(5):182. https:\/\/doi.org\/10.1007\/s11250-024-04037-4.","journal-title":"Trop Anim Health Prod"},{"key":"6689_CR128","doi-asserted-by":"publisher","DOI":"10.1016\/j.foodchem.2021.129299","volume":"352","author":"I Battisti","year":"2021","unstructured":"Battisti I, Ebinezer LB, Lomolino G, Masi A, Arrigoni G. Protein profile of commercial soybean milks analyzed by label-free quantitative proteomics. Food Chem t. 2021;352:129299. https:\/\/doi.org\/10.1016\/j.foodchem.2021.129299.","journal-title":"Food Chem t"},{"key":"6689_CR129","doi-asserted-by":"publisher","unstructured":"Kontogiannis T, McElroy C, Quaglia M, Foy C, Whale AS, Braybrook J. Development of LC-MS methods for AAV capsid protein quantification and host cell protein profiling. Mol Ther Methods Clin Dev. 2025;33(3):101562. https:\/\/doi.org\/10.1016\/j.omtm.2025.101562.","DOI":"10.1016\/j.omtm.2025.101562"},{"issue":"11","key":"6689_CR130","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1124\/dmd.124.001600","volume":"52","author":"B Prasad","year":"2024","unstructured":"Prasad B, Al-Majdoub ZM, Wegler C, Rostami-Hodjegan A, Achour B. Quantitative proteomics for translational pharmacology and precision medicine: state of the art and future outlook. Drug Metab Dispos. 2024;52(11):1208\u201316. https:\/\/doi.org\/10.1124\/dmd.124.001600.","journal-title":"Drug Metab Dispos"},{"key":"6689_CR131","doi-asserted-by":"publisher","unstructured":"Zheng Y, Liu Y, Yang J, Dong L, Zhang R, Tian S. Multi-omics data integration using ratio-based quantitative profiling with Quartet reference materials. Nat Biotechnol. 2024;42(7):1133\u201349. https:\/\/doi.org\/10.1038\/s41587-023-01934-1.","DOI":"10.1038\/s41587-023-01934-1"}],"updated-by":[{"DOI":"10.1007\/s00216-026-06749-y","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T00:00:00Z","timestamp":1786665600000}}],"container-title":["Analytical and Bioanalytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-026-06689-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00216-026-06689-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00216-026-06689-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T05:12:42Z","timestamp":1786684362000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00216-026-06689-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,29]]},"references-count":131,"alternative-id":["6689"],"URL":"https:\/\/doi.org\/10.1007\/s00216-026-06689-7","relation":{},"ISSN":["1618-2642","1618-2650"],"issn-type":[{"value":"1618-2642","type":"print"},{"value":"1618-2650","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,29]]},"assertion":[{"value":"31 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 August 2026","order":6,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":7,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The original online version of this article was revised: \"Qinde Liu\" has been incorrectly spelled as Qinde Lui.","order":8,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 August 2026","order":9,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":10,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":11,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s00216-026-06749-y","URL":"https:\/\/doi.org\/10.1007\/s00216-026-06749-y","order":12,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Certain equipment, instruments, software, or materials, commercial or noncommercial, are identified in this paper in order to specify the experimental procedure adequately. Such identification does not imply recommendation or endorsement of any product or service by NIST, nor does it imply that the materials or equipment identified are necessarily the best available for the purpose.","order":2,"name":"Ethics","label":"Disclaimer","group":{"name":"EthicsHeading","label":"Declarations"}}]}}