{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T16:15:31Z","timestamp":1771258531750,"version":"3.50.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2010,4,13]],"date-time":"2010-04-13T00:00:00Z","timestamp":1271116800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neuroradiology"],"published-print":{"date-parts":[[2010,12]]},"DOI":"10.1007\/s00234-010-0689-2","type":"journal-article","created":{"date-parts":[[2010,4,12]],"date-time":"2010-04-12T09:21:39Z","timestamp":1271064099000},"page":"1095-1100","source":"Crossref","is-referenced-by-count":20,"title":["Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study"],"prefix":"10.1007","volume":"52","author":[{"name":"Brain Research Group","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"In Hyouk","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua H.","family":"You","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ji Yong","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kum","family":"Whang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Myung Soon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young Ju","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Myeong Sub","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,4,13]]},"reference":[{"key":"689_CR1","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.rcl.2008.10.008","volume":"47","author":"CJ Ledezma","year":"2009","unstructured":"Ledezma CJ, Wintermark M (2009) Multimodal ct in stroke imaging: new concepts. Radiol Clin North Am 47:109\u2013116","journal-title":"Radiol Clin North Am"},{"key":"689_CR2","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1148\/radiology.209.1.9769817","volume":"209","author":"M Koenig","year":"1998","unstructured":"Koenig M, Klotz E, Luka B, Venderink DJ, Spittler JF, Heuser L (1998) Perfusion ct of the brain: diagnostic approach for early detection of ischemic stroke. Radiology 209:85\u201393","journal-title":"Radiology"},{"key":"689_CR3","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1001\/archneur.57.8.1161","volume":"57","author":"J Rother","year":"2000","unstructured":"Rother J, Jonetz-Mentzel L, Fiala A et al (2000) Hemodynamic assessment of acute stroke using dynamic single-slice computed tomographic perfusion imaging. Arch Neurol 57:1161\u20131166","journal-title":"Arch Neurol"},{"key":"689_CR4","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1148\/radiology.213.1.r99oc03141","volume":"213","author":"DG Nabavi","year":"1999","unstructured":"Nabavi DG, Cenic A, Craen RA et al (1999) Ct assessment of cerebral perfusion: experimental validation and initial clinical experience. Radiology 213:141\u2013149","journal-title":"Radiology"},{"key":"689_CR5","first-page":"1077","volume":"22","author":"HC Roberts","year":"2001","unstructured":"Roberts HC, Roberts TP, Smith WS, Lee TJ, Fischbein NJ, Dillon WP (2001) Multisection dynamic ct perfusion for acute cerebral ischemia: the \"Toggling-table\" technique. AJNR Am J Neuroradiol 22:1077\u20131080","journal-title":"AJNR Am J Neuroradiol"},{"key":"689_CR6","first-page":"104","volume":"26","author":"M Wintermark","year":"2005","unstructured":"Wintermark M, Fischbein NJ, Smith WS, Ko NU, Quist M, Dillon WP (2005) Accuracy of dynamic perfusion ct with deconvolution in detecting acute hemispheric stroke. AJNR Am J Neuroradiol 26:104\u2013112","journal-title":"AJNR Am J Neuroradiol"},{"key":"689_CR7","doi-asserted-by":"crossref","first-page":"W120","DOI":"10.2214\/AJR.07.2519","volume":"191","author":"SW Youn","year":"2008","unstructured":"Youn SW, Kim JH, Weon YC, Kim SH, Han MK, Bae HJ (2008) Perfusion ct of the brain using 40-mm-wide detector and toggling table technique for initial imaging of acute stroke. AJR Am J Roentgenol 191:W120\u2013W126","journal-title":"AJR Am J Roentgenol"},{"key":"689_CR8","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1097\/00004424-198301000-00018","volume":"18","author":"L Axel","year":"1983","unstructured":"Axel L (1983) Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique. Invest Radiol 18:94\u201399","journal-title":"Invest Radiol"},{"key":"689_CR9","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1212\/WNL.42.2.289","volume":"42","author":"EB Ringelstein","year":"1992","unstructured":"Ringelstein EB, Biniek R, Weiller C, Ammeling B, Nolte PN, Thron A (1992) Type and extent of hemispheric brain infarctions and clinical outcome in early and delayed middle cerebral artery recanalization. Neurology 42:289\u2013298","journal-title":"Neurology"},{"key":"689_CR10","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1148\/radiol.2282011860","volume":"228","author":"HL Kundel","year":"2003","unstructured":"Kundel HL, Polansky M (2003) Measurement of observer agreement. Radiology 228:303\u2013308","journal-title":"Radiology"},{"key":"689_CR11","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1002\/ana.10136","volume":"51","author":"M Wintermark","year":"2002","unstructured":"Wintermark M, Reichhart M, Thiran JP et al (2002) Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients. Ann Neurol 51:417\u2013432","journal-title":"Ann Neurol"},{"key":"689_CR12","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1097\/00004728-200411000-00004","volume":"28","author":"S Bisdas","year":"2004","unstructured":"Bisdas S, Donnerstag F, Ahl B, Bohrer I, Weissenborn K, Becker H (2004) Comparison of perfusion computed tomography with diffusion-weighted magnetic resonance imaging in hyperacute ischemic stroke. J Comput Assist Tomogr 28:747\u2013755","journal-title":"J Comput Assist Tomogr"},{"key":"689_CR13","doi-asserted-by":"crossref","first-page":"2025","DOI":"10.1161\/01.STR.0000023579.61630.AC","volume":"33","author":"M Wintermark","year":"2002","unstructured":"Wintermark M, Reichhart M, Cuisenaire O et al (2002) Comparison of admission perfusion computed tomography and qualitative diffusion- and perfusion-weighted magnetic resonance imaging in acute stroke patients. Stroke 33:2025\u20132031","journal-title":"Stroke"},{"key":"689_CR14","first-page":"720","volume":"25","author":"M Wintermark","year":"2004","unstructured":"Wintermark M, Smith WS, Ko NU, Quist M, Schnyder P, Dillon WP (2004) Dynamic perfusion ct: optimizing the temporal resolution and contrast volume for calculation of perfusion ct parameters in stroke patients. AJNR Am J Neuroradiol 25:720\u2013729","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-010-0689-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00234-010-0689-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-010-0689-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,24]],"date-time":"2019-05-24T13:34:59Z","timestamp":1558704899000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00234-010-0689-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,4,13]]},"references-count":14,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2010,12]]}},"alternative-id":["689"],"URL":"https:\/\/doi.org\/10.1007\/s00234-010-0689-2","relation":{},"ISSN":["0028-3940","1432-1920"],"issn-type":[{"value":"0028-3940","type":"print"},{"value":"1432-1920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,4,13]]}}}