{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T18:13:55Z","timestamp":1782756835325,"version":"3.54.5"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2014,4,17]],"date-time":"2014-04-17T00:00:00Z","timestamp":1397692800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neuroradiology"],"published-print":{"date-parts":[[2014,7]]},"DOI":"10.1007\/s00234-014-1363-x","type":"journal-article","created":{"date-parts":[[2014,4,16]],"date-time":"2014-04-16T12:37:43Z","timestamp":1397651863000},"page":"543-551","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":77,"title":["Coil embolization of intracranial saccular aneurysms using the Low-profile Visualized Intraluminal Support (LVIS\u2122) device"],"prefix":"10.1007","volume":"56","author":[{"given":"Young Dae","family":"Cho","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chul-Ho","family":"Sohn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyun-Seung","family":"Kang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeong Eun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Won-Sang","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gyojun","family":"Hwang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"O-Ki","family":"Kwon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mi-Sun","family":"Ko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nam-Mi","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moon Hee","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2014,4,17]]},"reference":[{"key":"1363_CR1","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.crad.2012.07.017","volume":"68","author":"SJ Lee","year":"2013","unstructured":"Lee SJ, Cho YD, Kang HS et al (2013) Coil embolization using the self-expandable closed-cell stent for intracranial saccular aneurysm: a single-center experience of 289 consecutive aneurysms. Clin Radiol 68:256\u2013263","journal-title":"Clin Radiol"},{"key":"1363_CR2","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1161\/STROKEAHA.109.558114","volume":"41","author":"M Piotin","year":"2010","unstructured":"Piotin M, Blanc R, Spelle L et al (2010) Stent-assistedcoiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms. Stroke 41:110\u2013115","journal-title":"Stroke"},{"key":"1363_CR3","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1007\/s00234-013-1277-z","volume":"55","author":"B Gory","year":"2013","unstructured":"Gory B, Klisch J, Bonaf\u00e9 A et al (2013) Solitaire AB stent-assisted coiling of wide-necked intracranial aneurysms: short-term results from a prospective, consecutive, European multicentric study. Neuroradiology 55:1373\u20131378","journal-title":"Neuroradiology"},{"key":"1363_CR4","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1007\/s00234-013-1143-z","volume":"55","author":"Z Kulcs\u00e1r","year":"2013","unstructured":"Kulcs\u00e1r Z, G\u00f6ricke SL, Gizewski ER et al (2013) Neuroform stent-assisted treatment of intracranial aneurysms: long-term follow-up study of aneurysm recurrence and in-stent stenosis rates. Neuroradiology 55:459\u2013465","journal-title":"Neuroradiology"},{"key":"1363_CR5","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1177\/159101990701300305","volume":"13","author":"R Juszkat","year":"2007","unstructured":"Juszkat R, Nowak S, Sm\u00f3l S et al (2007) Leo stent for endovascular treatment of broad-necked and fusiform intracranial aneurysms. Interv Neuroradiol 13:255\u2013269","journal-title":"Interv Neuroradiol"},{"issue":"Suppl 3","key":"1363_CR6","doi-asserted-by":"crossref","first-page":"iii79","DOI":"10.1136\/neurintsurg-2012-010553","volume":"5","author":"AM Spiotta","year":"2013","unstructured":"Spiotta AM, Miranpuri A, Chaudry MI et al (2013) Combined balloon stent technique with the Scepter C balloon and low-profile visualized intraluminal stent for the treatment of intracranial aneurysms. J Neurointerv Surg 5(Suppl 3):iii79\u2013iii82","journal-title":"J Neurointerv Surg"},{"key":"1363_CR7","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1007\/s00234-008-0460-0","volume":"50","author":"I Wanke","year":"2008","unstructured":"Wanke I, Forsting M (2008) Stents for intracranial wide-necked aneurysms: more thanmechanical protection. Neuroradiology 50:991\u2013998","journal-title":"Neuroradiology"},{"key":"1363_CR8","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1115\/1.2796081","volume":"119","author":"M Aenis","year":"1997","unstructured":"Aenis M, Stancampiano AP, Wakhloo AK et al (1997) Modeling of flow in a straight stented and nonstented side wall aneurysm model. J Biomech Eng 119:206\u2013212","journal-title":"J Biomech Eng"},{"key":"1363_CR9","first-page":"107","volume":"47","author":"CC Phatouros","year":"2000","unstructured":"Phatouros CC, Sasaki TY, Higashida RT et al (2000) Stent-supported coil embolization: the treatment of fusiform and wide-neck aneurysms and pseudoaneurysms. Neurosurgery 47:107\u2013113","journal-title":"Neurosurgery"},{"key":"1363_CR10","doi-asserted-by":"crossref","first-page":"1998","DOI":"10.1161\/hs0901.095600","volume":"32","author":"D Roy","year":"2001","unstructured":"Roy D, Milot G, Raymond J (2001) Endovascular treatment of unruptured aneurysms. Stroke 32:1998\u20132004","journal-title":"Stroke"},{"key":"1363_CR11","doi-asserted-by":"crossref","first-page":"e63","DOI":"10.1016\/j.crad.2013.08.021","volume":"69","author":"WS Cho","year":"2014","unstructured":"Cho WS, Kang HS, Kim JE et al (2014) Angle change of the parent arteries after stent-assisted coil embolization of the wide-necked intracranial bifurcation aneurysms. Clin Radiol 69:e63\u2013e70","journal-title":"Clin Radiol"},{"key":"1363_CR12","doi-asserted-by":"crossref","first-page":"35","DOI":"10.3171\/2008.7.JNS08322","volume":"110","author":"J Mocco","year":"2009","unstructured":"Mocco J, Snyder KV, Albuquerque FC et al (2009) Treatment of intracranial aneurysms with the Enterprise stent: a multicenter registry. J Neurosurg 110:35\u201339","journal-title":"J Neurosurg"},{"key":"1363_CR13","doi-asserted-by":"crossref","first-page":"872","DOI":"10.2214\/AJR.12.8954","volume":"200","author":"Y Kadkhodayan","year":"2013","unstructured":"Kadkhodayan Y, Rhodes N, Blackburn S et al (2013) Comparison of Enterprise with Neuroform stent-assisted coiling of intracranial aneurysms. AJR Am J Roentgenol 200:872\u2013878","journal-title":"AJR Am J Roentgenol"},{"key":"1363_CR14","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.3174\/ajnr.A3379","volume":"34","author":"JC Gentric","year":"2013","unstructured":"Gentric JC, Biondi A, Piotin M et al (2013) Safety and efficacy of Neuroform for treatment of intracranial aneurysms: a prospective, consecutive, French multicentric study. AJNR Am J Neuroradiol 34:1203\u20131208","journal-title":"AJNR Am J Neuroradiol"},{"key":"1363_CR15","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1055\/s-0031-1271681","volume":"54","author":"O Krischek","year":"2011","unstructured":"Krischek O, Miloslavski E, Fischer S et al (2011) A comparison of functional and physical properties of self-expanding intracranial stents [Neuroform3, Wingspan, Solitaire, Leo+, Enterprise]. Minim Invasive Neurosurg 54:21\u201328","journal-title":"Minim Invasive Neurosurg"},{"key":"1363_CR16","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1136\/neurintsurg-2011-010187","volume":"5","author":"RD Turner","year":"2013","unstructured":"Turner RD, Turk A, Chaudry I (2013) Low-profile visible intraluminal support device: immediate outcome of the first three US cases. J Neurointerv Surg 5:157\u2013160","journal-title":"J Neurointerv Surg"},{"issue":"3 Suppl","key":"1363_CR17","first-page":"130","volume":"64","author":"M Valdivia y Alvarado","year":"2009","unstructured":"Valdivia y Alvarado M, Ebrahimi N, Benndorf G (2009) Study of conformability of the new leo plus stent to a curved vascular model using flat-panel detector computed tomography (DynaCT). Neurosurgery 64(3 Suppl):130\u2013134","journal-title":"Neurosurgery"},{"key":"1363_CR18","doi-asserted-by":"crossref","first-page":"649","DOI":"10.3174\/ajnr.A2841","volume":"33","author":"B Gao","year":"2012","unstructured":"Gao B, Baharoglu MI, Cohen AD et al (2012) Stent-assisted coiling of intracranial bifurcation aneurysms leads to immediate and delayed intracranial vascular angle remodeling. AJNR Am J Neuroradiol 33:649\u2013654","journal-title":"AJNR Am J Neuroradiol"},{"key":"1363_CR19","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1227\/NEU.0b013e3182846d9f","volume":"72","author":"B Gao","year":"2013","unstructured":"Gao B, Baharoglu MI, Cohen AD et al (2013) Y-Stent coiling of basilar bifurcation aneurysms induces a dynamic angular vascular remodeling with alteration of the apical wall shear stress pattern. Neurosurgery 72:617\u2013629","journal-title":"Neurosurgery"},{"key":"1363_CR20","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1227\/NEU.0b013e318228490c","volume":"69","author":"J Mocco","year":"2011","unstructured":"Mocco J, Fargen KM, Albuquerque FC et al (2011) Delayed thrombosis or stenosis following Enterprise-assisted stent-coiling: is it safe?: midterm results of the Interstate Collaboration of Enterprise Stent Coiling. Neurosurgery 69:908\u2013913","journal-title":"Neurosurgery"},{"key":"1363_CR21","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1227\/01.NEU.0000219853.56553.71","volume":"59","author":"D Fiorella","year":"2006","unstructured":"Fiorella D, Albuquerque FC, Woo H et al (2006) Neuroform in-stent stenosis: incidence, natural history, and treatment strategies. Neurosurgery 59:34\u201342","journal-title":"Neurosurgery"},{"key":"1363_CR22","doi-asserted-by":"crossref","first-page":"1523","DOI":"10.1227\/NEU.0b013e3181f8d194","volume":"67","author":"H Kanaan","year":"2010","unstructured":"Kanaan H, Jankowitz B, Aleu A et al (2010) In-stent thrombosis and stenosis after neck-remodeling device-assisted coil embolization of intracranial aneurysms. Neurosurgery 67:1523\u20131532","journal-title":"Neurosurgery"},{"key":"1363_CR23","doi-asserted-by":"crossref","first-page":"485","DOI":"10.3340\/jkns.2010.48.6.485","volume":"48","author":"KW Yoon","year":"2010","unstructured":"Yoon KW, Kim YJ (2010) In-stent stenosis of stent assisted endovascular treatment on intracranial complex aneurysms. J Korean Neurosurg Soc 48:485\u2013489","journal-title":"J Korean Neurosurg Soc"},{"key":"1363_CR24","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1227\/NEU.0b013e31828046a6","volume":"72","author":"N Chalouhi","year":"2013","unstructured":"Chalouhi N, Drueding R, Starke RM et al (2013) In-stent stenosis after stent-assisted coiling: incidence, predictors and clinical outcomes of 435 cases. Neurosurgery 72:390\u2013396","journal-title":"Neurosurgery"},{"key":"1363_CR25","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1016\/S0140-6736(00)03262-1","volume":"356","author":"R K\u00f6ster","year":"2000","unstructured":"K\u00f6ster R, Vieluf D, Kiehn M et al (2000) Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 356:1895\u20131897","journal-title":"Lancet"},{"key":"1363_CR26","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.carrev.2008.01.004","volume":"10","author":"T Saito","year":"2009","unstructured":"Saito T, Hokimoto S, Oshima S et al (2009) Metal allergic reaction in chronic refractory in-stent restenosis. Cardiovasc Revasc Med 10:17\u201322","journal-title":"Cardiovasc Revasc Med"},{"key":"1363_CR27","author":"B Gao","year":"2014","unstructured":"Gao B, Safain MG, Malek AM (2014) Enterprise stenting for intracranial aneurysm treatment induces dynamic and reversible age-dependent stenosis in cerebral arteries. J Neurointerv Surg. doi: 10.1136\/neurintsurg-2013-011074","journal-title":"J Neurointerv Surg"}],"container-title":["Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-014-1363-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00234-014-1363-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-014-1363-x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,9]],"date-time":"2019-08-09T15:55:29Z","timestamp":1565366129000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00234-014-1363-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,4,17]]},"references-count":27,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2014,7]]}},"alternative-id":["1363"],"URL":"https:\/\/doi.org\/10.1007\/s00234-014-1363-x","relation":{},"ISSN":["0028-3940","1432-1920"],"issn-type":[{"value":"0028-3940","type":"print"},{"value":"1432-1920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,4,17]]}}}