{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T15:20:56Z","timestamp":1772119256216,"version":"3.50.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T00:00:00Z","timestamp":1758240000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T00:00:00Z","timestamp":1758240000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100018935","name":"Universit\u00e4tsklinikum Erlangen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100018935","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neuroradiology"],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and purpose<\/jats:title>\n                    <jats:p>Deep-learning (DL) based MRI denoising techniques promise improved image quality and shorter examination times. This advancement is particularly beneficial for 0.55T MRI, where the inherently lower signal-to-noise (SNR) ratio can compromise image quality. Sufficient SNR is crucial for the reliable detection of vestibular schwannoma (VS). The objective of this study is to evaluate the VS conspicuity and acquisition time (TA) of 0.55T MRI examinations with contrast agents using a DL-denoising algorithm.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>From January 2024 to October 2024, we retrospectively included 30 patients with VS (9 women). We acquired a clinical reference protocol of the cerebellopontine angle containing a T1w fat-saturated (fs) axial (number of signal averages [NSA] 4) and a T1w Spectral Attenuated Inversion Recovery (SPAIR) coronal (NSA 2) sequence after contrast agent (CA) application without advanced DL-based denoising (w\/o DL). We reconstructed the T1w fs CA sequence axial and the T1w SPAIR CA coronal with full DL-denoising mode without change of NSA, and secondly with 1 NSA for T1w fs CA axial and T1w SPAIR coronal (DL&amp;1NSA). Each sequence was rated on a 5-point Likert scale (1: insufficient, 3: moderate, clinically sufficient; 5: perfect) for: overall image quality; VS conspicuity, and artifacts. Secondly, we analyzed the reliability of the size measurements. Two radiologists specializing in head and neck imaging performed the reading and measurements. The Wilcoxon Signed-Rank Test was used for non-parametric statistical comparison.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The DL&amp;4NSA axial\/coronal study sequence achieved the highest overall IQ (median 4.9). The image quality (IQ) for DL&amp;1NSA was higher (M: 4.0) than for the reference sequence (w\/o DL; median 4.0 versus 3.5, each p &lt; 0.01). Similarly, the VS conspicuity was best for DL&amp;4NSA (M: 4.9), decreased for DL&amp;1NSA (M: 4.1), and was lower but still sufficient for w\/o DL (M: 3.7, each p &lt; 0.01). The TA for the axial and coronal post-contrast sequences was 8:59 minutes for DL&amp;4NSA and w\/o DL and decreased to 3:24 minutes with DL&amp;1NSA.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study underlines that advanced DL-based denoising techniques can reduce the examination time by more than half while simultaneously improving image quality.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00234-025-03758-z","type":"journal-article","created":{"date-parts":[[2025,9,19]],"date-time":"2025-09-19T09:00:00Z","timestamp":1758272400000},"page":"3565-3574","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Deep learning-based acceleration and denoising of 0.55T MRI for enhanced conspicuity of vestibular Schwannoma post contrast administration"],"prefix":"10.1007","volume":"67","author":[{"given":"Maximilian","family":"Hinsen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Armin","family":"Nagel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rafael","family":"Heiss","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"May","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Wiesmueller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claudius","family":"Mathy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Zeilinger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joachim","family":"Hornung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarina","family":"Mueller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Uder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Markus","family":"Kopp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,9,19]]},"reference":[{"issue":"2","key":"3758_CR1","doi-asserted-by":"publisher","first-page":"103337","DOI":"10.1016\/j.amjoto.2021.103337","volume":"43","author":"NLB Thai","year":"2022","unstructured":"Thai NLB, Mai NY, Vuong NL, Tin NM, Karam D, Refaey MA, Shahin KM, Soliman AL, Al Khudari R, Thuan TM, Sabbah GM, El-Qushayri AE, Karimzadeh S, Hirayama K, Huy NT (2022) Treatment for vestibular schwannoma: systematic review and single arm meta-analysis. Am J Otolaryngol 43(2):103337. https:\/\/doi.org\/10.1016\/j.amjoto.2021.103337","journal-title":"Am J Otolaryngol"},{"issue":"1","key":"3758_CR2","doi-asserted-by":"publisher","first-page":"e028","DOI":"10.1097\/ONO.0000000000000028","volume":"3","author":"S Kortebein","year":"2023","unstructured":"Kortebein S, Gu S, Dai K, Zhao E, Riska K, Kaylie D, Hoa M (2023) MRI screening in vestibular schwannoma: a deep learning-based analysis of clinical and audiometric data. Otol Neurotol Open 3(1):e028. https:\/\/doi.org\/10.1097\/ONO.0000000000000028","journal-title":"Otol Neurotol Open"},{"issue":"5","key":"3758_CR3","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1097\/MOO.0000000000000647","volume":"28","author":"L Dang","year":"2020","unstructured":"Dang L, Tu NC, Chan EY (2020) Current imaging tools for vestibular Schwannoma. Curr Opin Otolaryngol Head Neck Surg 28(5):302\u2013307. https:\/\/doi.org\/10.1097\/MOO.0000000000000647","journal-title":"Curr Opin Otolaryngol Head Neck Surg"},{"key":"3758_CR4","doi-asserted-by":"publisher","unstructured":"Biber S, Kannengiesser S, Nistler J, Braun M, Blaess S, Gebhardt M, Grodzki D, Ritter D, Seegerer G, Vester M, Schneider R (2025) Design and operation of a whole-body MRI scanner without RF shielding. magnetic resonance in medicine: official journal of the society of magnetic resonance in medicine \/ society of magnetic resonance in medicine 93(4):1842\u20131855. https:\/\/doi.org\/10.1002\/mrm.30374","DOI":"10.1002\/mrm.30374"},{"issue":"11","key":"3758_CR5","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1097\/RLI.0000000000000805","volume":"56","author":"R Heiss","year":"2021","unstructured":"Heiss R, Nagel AM, Laun FB, Uder M, Bickelhaupt S (2021) Low-Field magnetic resonance imaging: a new generation of breakthrough technology in clinical imaging. Invest Radiol 56(11):726\u2013733. https:\/\/doi.org\/10.1097\/RLI.0000000000000805","journal-title":"Invest Radiol"},{"issue":"1","key":"3758_CR6","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1002\/jmri.28408","volume":"57","author":"TC Arnold","year":"2023","unstructured":"Arnold TC, Freeman CW, Litt B, Stein JM (2023) Low-field MRI: clinical promise and challenges. J Magn Reson Imaging: JMRI 57(1):25\u201344. https:\/\/doi.org\/10.1002\/jmri.28408","journal-title":"J Magn Reson Imaging: JMRI"},{"key":"3758_CR7","doi-asserted-by":"publisher","first-page":"110927","DOI":"10.1016\/j.ejrad.2023.110927","volume":"165","author":"M Wiesmueller","year":"2023","unstructured":"Wiesmueller M, Kopp M, Sievert M, May MS, Nagel AM, Iro H, Uder M, Heiss R (2023) Comparison of vestibular Schwannoma visualization between 0.55 T and 1.5 T MRI. Eur J Radiol 165:110927. https:\/\/doi.org\/10.1016\/j.ejrad.2023.110927","journal-title":"Eur J Radiol"},{"key":"3758_CR8","unstructured":"EC COUNCIL DIRECTIVE 2013\/59\/EURATOM of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation arD"},{"issue":"3","key":"3758_CR9","doi-asserted-by":"publisher","first-page":"e240076","DOI":"10.1148\/rg.240076","volume":"45","author":"LJ Kelsey","year":"2025","unstructured":"Kelsey LJ, Seiberlich N, Morehouse J, Richardson J, Srinivasan A, Bapuraj J, Kim J, Gulani V, Mishra S (2025) Routine and advanced neurologic imaging at 0.55-T MRI: opportunities and challenges. Radiographics: Rev Publication Radiological Soc North Am Inc 45(3):e240076. https:\/\/doi.org\/10.1148\/rg.240076","journal-title":"Radiographics: Rev Publication Radiological Soc North Am Inc"},{"key":"3758_CR10","doi-asserted-by":"publisher","first-page":"111017","DOI":"10.1016\/j.ejrad.2023.111017","volume":"166","author":"KL Lee","year":"2023","unstructured":"Lee KL, Kessler DA, Dezonie S, Chishaya W, Shepherd C, Carmo B, Graves MJ, Barrett T (2023) Assessment of deep learning-based reconstruction on T2-weighted and diffusion-weighted prostate MRI image quality. Eur J Radiol 166:111017. https:\/\/doi.org\/10.1016\/j.ejrad.2023.111017","journal-title":"Eur J Radiol"},{"issue":"8","key":"3758_CR11","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1097\/RLI.0000000000000769","volume":"56","author":"H Almansour","year":"2021","unstructured":"Almansour H, Gassenmaier S, Nickel D, Kannengiesser S, Afat S, Weiss J, Hoffmann R, Othman AE (2021) Deep learning-based superresolution reconstruction for upper abdominal magnetic resonance imaging: an analysis of image quality, diagnostic confidence, and lesion conspicuity. Invest Radiol 56(8):509\u2013516. https:\/\/doi.org\/10.1097\/RLI.0000000000000769","journal-title":"Invest Radiol"},{"key":"3758_CR12","doi-asserted-by":"publisher","unstructured":"Herrmann J, Koerzdoerfer G, Nickel D, Mostapha M, Nadar M, Gassenmaier S, Kuestner T, Othman AE (2021) Feasibility and implementation of a deep learning MR reconstruction for TSE sequences in musculoskeletal imaging. Diagnostics (Basel) 11(8). https:\/\/doi.org\/10.3390\/diagnostics11081484","DOI":"10.3390\/diagnostics11081484"},{"issue":"5","key":"3758_CR13","doi-asserted-by":"publisher","first-page":"e200279","DOI":"10.1148\/ryai.2021200279","volume":"3","author":"K Zormpas-Petridis","year":"2021","unstructured":"Zormpas-Petridis K, Tunariu N, Curcean A, Messiou C, Curcean S, Collins DJ, Hughes JC, Jamin Y, Koh DM, Blackledge MD (2021) Accelerating whole-body diffusion-weighted MRI with deep learning-based denoising image filters. Radiol Artif Intell 3(5):e200279. https:\/\/doi.org\/10.1148\/ryai.2021200279","journal-title":"Radiol Artif Intell"},{"issue":"1","key":"3758_CR14","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.acra.2022.03.018","volume":"30","author":"J Herrmann","year":"2023","unstructured":"Herrmann J, Wessling D, Nickel D, Arberet S, Almansour H, Afat C, Afat S, Gassenmaier S, Othman AE (2023) Comprehensive clinical evaluation of a deep learning-accelerated, single-breath-hold abdominal HASTE at 1.5 T and 3 T. Acad Radiol 30(1):93\u2013102. https:\/\/doi.org\/10.1016\/j.acra.2022.03.018","journal-title":"Acad Radiol"},{"key":"3758_CR15","doi-asserted-by":"publisher","first-page":"100567","DOI":"10.1016\/j.ejro.2024.100567","volume":"12","author":"F Schlicht","year":"2024","unstructured":"Schlicht F, Vosshenrich J, Donners R, Seifert AC, Fenchel M, Nickel D, Obmann M, Harder D, Breit HC (2024) Advanced deep learning-based image reconstruction in lumbar spine MRI at 0.55 T - effects on image quality and acquisition time in comparison to conventional deep learning-based reconstruction. Eur J Radiol Open 12:100567. https:\/\/doi.org\/10.1016\/j.ejro.2024.100567","journal-title":"Eur J Radiol Open"},{"key":"3758_CR16","doi-asserted-by":"publisher","unstructured":"Lopez Schmidt I, Haag N, Shahzadi I, Frohwein LJ, Schneider C, Niehoff JH, Kroeger JR, Borggrefe J, Moenninghoff C (2023) Diagnostic image quality of a Low-Field (0.55T) knee MRI protocol using deep learning image reconstruction compared with a standard (1.5T) knee MRI protocol. J Clin Med 12(5). https:\/\/doi.org\/10.3390\/jcm12051916","DOI":"10.3390\/jcm12051916"},{"issue":"4","key":"3758_CR17","doi-asserted-by":"publisher","first-page":"2109","DOI":"10.1002\/mrm.28550","volume":"85","author":"J Hanspach","year":"2021","unstructured":"Hanspach J, Nagel AM, Hensel B, Uder M, Koros L, Laun FB (2021) Sample size estimation: current practice and considerations for original investigations in MRI technical development studies. Magn Reson Medicine: Official J Soc Magn Reson Med \/ Soc Magn Reson Med 85(4):2109\u20132116. https:\/\/doi.org\/10.1002\/mrm.28550","journal-title":"Magn Reson Medicine: Official J Soc Magn Reson Med \/ Soc Magn Reson Med"},{"issue":"4","key":"3758_CR18","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1002\/pst.185","volume":"4","author":"SA Julious","year":"2005","unstructured":"Julious SA (2005) Sample size of 12 per group rule of thumb for a pilot study. Pharm Stat 4(4):287\u2013291. https:\/\/doi.org\/10.1002\/pst.185","journal-title":"Pharm Stat"},{"issue":"1","key":"3758_CR19","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159\u2013174","journal-title":"Biometrics"},{"issue":"7","key":"3758_CR20","doi-asserted-by":"publisher","first-page":"4875","DOI":"10.1007\/s00330-023-09472-9","volume":"33","author":"GC Feuerriegel","year":"2023","unstructured":"Feuerriegel GC, Weiss K, Kronthaler S, Leonhardt Y, Neumann J, Wurm M, Lenhart NS, Makowski MR, Schwaiger BJ, Woertler K, Karampinos DC, Gersing AS (2023) Evaluation of a deep learning-based reconstruction method for denoising and image enhancement of shoulder MRI in patients with shoulder pain. Eur Radiol 33(7):4875\u20134884. https:\/\/doi.org\/10.1007\/s00330-023-09472-9","journal-title":"Eur Radiol"},{"key":"3758_CR21","doi-asserted-by":"publisher","unstructured":"Schuhholz M, Ruff C, Burkle E, Feiweier T, Clifford B, Kowarik M, Bender B (2024) Ultrafast brain MRI at 3 T for MS: evaluation of a 51-second deep learning-enhanced T2-EPI-FLAIR sequence. Diagnostics (Basel) 14(17). https:\/\/doi.org\/10.3390\/diagnostics14171841","DOI":"10.3390\/diagnostics14171841"},{"key":"3758_CR22","doi-asserted-by":"publisher","unstructured":"Hossain MB, Shinde RK, Oh S, Kwon KC, Kim N (2024) A systematic review and identification of the challenges of deep learning techniques for undersampled magnetic resonance image reconstruction. Sensors 24(3). https:\/\/doi.org\/10.3390\/s24030753","DOI":"10.3390\/s24030753"},{"key":"3758_CR23","doi-asserted-by":"publisher","unstructured":"Singh SP, Wang L, Gupta S, Goli H, Padmanabhan P, Gulyas B (2020) 3D deep learning on medical images: a review. Sensors 20(18). https:\/\/doi.org\/10.3390\/s20185097","DOI":"10.3390\/s20185097"}],"container-title":["Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-025-03758-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00234-025-03758-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-025-03758-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T06:14:21Z","timestamp":1769494461000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00234-025-03758-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,19]]},"references-count":23,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["3758"],"URL":"https:\/\/doi.org\/10.1007\/s00234-025-03758-z","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-6518258\/v1","asserted-by":"object"}]},"ISSN":["0028-3940","1432-1920"],"issn-type":[{"value":"0028-3940","type":"print"},{"value":"1432-1920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,19]]},"assertion":[{"value":"24 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective study was approved by the local ethics committee in accordance with the Declaration of Helsinki (Ethik-Kommission der Medizinischen Fakult\u00e4t der Universit\u00e4t Erlangen-Nuernberg, Erlangen, Germany; No 24_79_BR).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All participants consented to the MRI examination with contrast medium administration. A retrospective informed consent for study participation was waived by the local ethics committee.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"M.H. M.K. M.U., M.M., and R.H. are part of the speaker\u2019s bureau of Siemens Healthineers GmbH. The authors have no further affiliation with any organization with a direct or indirect financial interest in the subject matter discussed in the manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}