{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T03:04:02Z","timestamp":1777950242091,"version":"3.51.4"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T00:00:00Z","timestamp":1765929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T00:00:00Z","timestamp":1765929600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neuroradiology"],"published-print":{"date-parts":[[2026,4]]},"DOI":"10.1007\/s00234-025-03803-x","type":"journal-article","created":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T11:13:26Z","timestamp":1765970006000},"page":"975-985","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of deep learning reconstruction algorithms to improve image quality of dual-energy carotid CT angiography under dual-low scan"],"prefix":"10.1007","volume":"68","author":[{"given":"Shi","family":"Qiu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kai","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yankai","family":"Meng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenzi","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan","family":"Long","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenbei","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"He","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meng","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhongxiao","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aijun","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,12,17]]},"reference":[{"key":"3803_CR1","doi-asserted-by":"publisher","first-page":"e74333","DOI":"10.7759\/cureus.74333","volume":"16","author":"Y Wang","year":"2024","unstructured":"Wang Y, Wang X, Wang C, Zhou J (2024) Global, regional, and national burden of cardiovascular disease, 1990\u20132021: results from the 2021 global burden of disease study. Cureus 16:e74333. https:\/\/doi.org\/10.7759\/cureus.74333","journal-title":"Cureus"},{"key":"3803_CR2","doi-asserted-by":"publisher","first-page":"4348","DOI":"10.21037\/qims-23-1827","volume":"14","author":"N Han","year":"2024","unstructured":"Han N, Wang J, Ma Y, Ma L, Zheng Y, Fan F, Wu C, Yue S, Li J, Liang J, Zhang H, Zhou Y, Yang T, Zhang J (2024) The hemodynamic and geometric characteristics of carotid artery atherosclerotic plaque formation. Quant Imaging Med Surg 14:4348\u20134361. https:\/\/doi.org\/10.21037\/qims-23-1827","journal-title":"Quant Imaging Med Surg"},{"key":"3803_CR3","doi-asserted-by":"publisher","first-page":"e2351225","DOI":"10.1001\/jamanetworkopen.2023.51225","volume":"7","author":"J Fu","year":"2024","unstructured":"Fu J, Deng Y, Ma Y, Man S, Yang X, Yu C, Lv J, Wang B, Li L (2024) National and provincial-level prevalence and risk factors of carotid atherosclerosis in Chinese adults. JAMA Netw Open 7:e2351225. https:\/\/doi.org\/10.1001\/jamanetworkopen.2023.51225","journal-title":"JAMA Netw Open"},{"key":"3803_CR4","doi-asserted-by":"publisher","first-page":"73","DOI":"10.3390\/life14010073","volume":"14","author":"L Saba","year":"2024","unstructured":"Saba L, Scicolone R, Johansson E, Nardi V, Lanzino G, Kakkos SK, Pontone G, Annoni AD, Paraskevas KI, Fox AJ (2024) Quantifying carotid stenosis: history, current applications, limitations, and potential: how imaging is changing the scenario. Life (Basel) 14:73. https:\/\/doi.org\/10.3390\/life14010073","journal-title":"Life (Basel)"},{"key":"3803_CR5","doi-asserted-by":"publisher","first-page":"1284","DOI":"10.1148\/rg.2020200038","volume":"40","author":"P Rajiah","year":"2020","unstructured":"Rajiah P, Parakh A, Kay F, Baruah D, Kambadakone AR, Leng S (2020) Update on multienergy CT: physics, principles, and applications. Radiographics 40:1284\u20131308. https:\/\/doi.org\/10.1148\/rg.2020200038","journal-title":"Radiographics"},{"key":"3803_CR6","doi-asserted-by":"publisher","first-page":"1633","DOI":"10.1007\/s11547-024-01889-6","volume":"129","author":"C Booz","year":"2024","unstructured":"Booz C, Bucolo GM, D\u2019Angelo T, Mazziotti S, Lanzafame LRM, Yel I, Alizadeh LS, Gruenewald LD, Koch V, Martin SS, Dimitrova M, Goekduman A, Vogl TJ, Kaatsch HL, Overhoff D, Waldeck S (2024) Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability. Radiol Med 129:1633\u20131643. https:\/\/doi.org\/10.1007\/s11547-024-01889-6","journal-title":"Radiol Med"},{"key":"3803_CR7","doi-asserted-by":"publisher","first-page":"e032665","DOI":"10.1161\/JAHA.123.032665","volume":"13","author":"J Zhang","year":"2024","unstructured":"Zhang J, Li S, Wu L, Wang H, Wang C, Zhou Y, Sui B, Zhao X (2024) Application of dual-layer spectral-detector computed tomography angiography in identifying symptomatic carotid atherosclerosis: a prospective observational study. J Am Heart Assoc 13:e032665. https:\/\/doi.org\/10.1161\/JAHA.123.032665","journal-title":"J Am Heart Assoc"},{"key":"3803_CR8","doi-asserted-by":"publisher","first-page":"6345","DOI":"10.3390\/jcm13216345","volume":"13","author":"S Guerrini","year":"2024","unstructured":"Guerrini S, Zanoni M, Sica C, Bagnacci G, Mancianti N, Galzerano G, Garosi G, Cacioppa LM, Cellina M, Zamboni GA, Minetti G, Floridi C, Mazzei MA (2024) Dual-energy CT as a well-established CT modality to reduce contrast media amount: a systematic review from the Computed Tomography Subspecialty Section of the Italian Society of Radiology. J Clin Med 13:6345. https:\/\/doi.org\/10.3390\/jcm13216345","journal-title":"J Clin Med"},{"key":"3803_CR9","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1053\/j.ajkd.2019.05.022","volume":"75","author":"MR Rudnick","year":"2020","unstructured":"Rudnick MR, Leonberg-Yoo AK, Litt HI, Cohen RM, Hilton S, Reese PP (2020) The controversy of contrast-induced nephropathy with intravenous contrast: what is the risk? Am J Kidney Dis 75:105\u2013113. https:\/\/doi.org\/10.1053\/j.ajkd.2019.05.022","journal-title":"Am J Kidney Dis"},{"key":"3803_CR10","doi-asserted-by":"publisher","first-page":"7540","DOI":"10.1007\/s00330-021-07763-7","volume":"31","author":"M Mazloumi","year":"2021","unstructured":"Mazloumi M, Van Gompel G, Kersemans V, De Mey J, Buls N (2021) The presence of contrast agent increases organ radiation dose in contrast-enhanced CT. Eur Radiol 31:7540\u20137549. https:\/\/doi.org\/10.1007\/s00330-021-07763-7","journal-title":"Eur Radiol"},{"key":"3803_CR11","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1148\/radiol.2015132766","volume":"276","author":"LL Geyer","year":"2015","unstructured":"Geyer LL, Schoepf UJ, Meinel FG, Nance JW Jr, Bastarrika G, Leipsic JA, Paul NS, Rengo M, Laghi A, De Cecco CN (2015) State of the art: iterative CT reconstruction techniques. Radiology 276:339\u2013357. https:\/\/doi.org\/10.1148\/radiol.2015132766","journal-title":"Radiology"},{"key":"3803_CR12","doi-asserted-by":"publisher","first-page":"1971","DOI":"10.1093\/bjr\/tqae185","volume":"97","author":"J Li","year":"2024","unstructured":"Li J, Xiao Y, Cao L, Cheng Y, Li Y, Jia X, Li X, Fan G, Li J, Guo J (2024) Application value of individualized tube voltage, contrast injection, and adaptive statistical iterative reconstruction V algorithm based on body mass index in renal computed tomography angiography for radiation and iodinated contrast dose reduction. Br J Radiol 97:1971\u20131978. https:\/\/doi.org\/10.1093\/bjr\/tqae185","journal-title":"Br J Radiol"},{"key":"3803_CR13","doi-asserted-by":"publisher","first-page":"3156","DOI":"10.1007\/s00330-020-07358-8","volume":"31","author":"C Park","year":"2021","unstructured":"Park C, Choo KS, Jung Y, Jeong HS, Hwang JY, Yun MS (2021) CT iterative vs deep learning reconstruction: comparison of noise and sharpness. Eur Radiol 31:3156\u20133164. https:\/\/doi.org\/10.1007\/s00330-020-07358-8","journal-title":"Eur Radiol"},{"key":"3803_CR14","doi-asserted-by":"publisher","first-page":"5499","DOI":"10.1007\/s00330-022-08647-0","volume":"32","author":"M Sato","year":"2022","unstructured":"Sato M, Ichikawa Y, Domae K, Yoshikawa K, Kanii Y, Yamazaki A, Nagasawa N, Nagata M, Ishida M, Sakuma H (2022) Deep learning image reconstruction for improving image quality of contrast-enhanced dual-energy CT in abdomen. Eur Radiol 32:5499\u20135507. https:\/\/doi.org\/10.1007\/s00330-022-08647-0","journal-title":"Eur Radiol"},{"key":"3803_CR15","doi-asserted-by":"publisher","first-page":"2955","DOI":"10.21037\/qims-23-1602","volume":"14","author":"Q Zhang","year":"2024","unstructured":"Zhang Q, Lin Y, Zhang H, Ding J, Pan J, Zhang S (2024) The application value of a vendor-specific deep learning image reconstruction algorithm in \u201ctriple low\u201d head and neck computed tomography angiography. Quant Imaging Med Surg 14:2955\u20132967. https:\/\/doi.org\/10.21037\/qims-23-1602","journal-title":"Quant Imaging Med Surg"},{"issue":"1","key":"3803_CR16","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1007\/s00234-024-03461-5","volume":"67","author":"W Jung","year":"2025","unstructured":"Jung W, Jeong G, Kim S, Hwang I, Choi SH, Jeon YH, Choi KS, Lee JY, Yoo RE, Yun TJ, Kang KM (2025) Reliability of brain volume measures of accelerated 3D T1-weighted images with deep learning-based reconstruction. Neuroradiology 67(1):171\u2013182. https:\/\/doi.org\/10.1007\/s00234-024-03461-5","journal-title":"Neuroradiology"},{"issue":"8","key":"3803_CR17","doi-asserted-by":"publisher","first-page":"1345","DOI":"10.1007\/s00234-024-03310-5","volume":"66","author":"M Tranfa","year":"2024","unstructured":"Tranfa M, Scaravilli A, Pastore C, Montella A, Lanzillo R, Kimura M, Jasperse B, Morra VB, Petracca M, Pontillo G, Brunetti A, Cocozza S (2024) The impact of image contrast, resolution and reader expertise on black hole identification in multiple sclerosis. Neuroradiology 66(8):1345\u20131352. https:\/\/doi.org\/10.1007\/s00234-024-03310-5","journal-title":"Neuroradiology"},{"key":"3803_CR18","doi-asserted-by":"publisher","first-page":"154","DOI":"10.3390\/jimaging10070154","volume":"10","author":"R Garc\u00eda-Figueiras","year":"2024","unstructured":"Garc\u00eda-Figueiras R, Oleaga L, Broncano J, Tard\u00e1guila G, Fern\u00e1ndez-P\u00e9rez G, Va\u00f1\u00f3 E, Santos-Armentia E, M\u00e9ndez R, Luna A, Baleato-Gonz\u00e1lez S (2024) What to expect (and what not) from dual-energy CT imaging now and in the future? J Imaging 10:154. https:\/\/doi.org\/10.3390\/jimaging10070154","journal-title":"J Imaging"},{"key":"3803_CR19","doi-asserted-by":"publisher","first-page":"1223","DOI":"10.3390\/diagnostics14121223","volume":"14","author":"M Sta\u0144ski","year":"2024","unstructured":"Sta\u0144ski M, Micha\u0142owska I, Lemanowicz A, Karmelita-Katulska K, Ratajczak P, S\u0142awi\u0144ska A, Serafin Z (2024) Dual-energy and photon-counting computed tomography in vascular applications\u2014technical background and post-processing techniques. Diagnostics 14:1223. https:\/\/doi.org\/10.3390\/diagnostics14121223","journal-title":"Diagnostics"},{"key":"3803_CR20","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1097\/RCT.0000000000001450","volume":"47","author":"CA Dunning","year":"2023","unstructured":"Dunning CA, Rajendran K, Inoue A, Rajiah P, Weber N, Fletcher JG, McCollough CH, Leng S (2023) Optimal virtual monoenergetic photon energy (keV) for photon-counting-detector computed tomography angiography. J Comput Assist Tomogr 47:569\u2013575. https:\/\/doi.org\/10.1097\/RCT.0000000000001450","journal-title":"J Comput Assist Tomogr"},{"key":"3803_CR21","doi-asserted-by":"publisher","first-page":"e651","DOI":"10.1016\/j.crad.2024.01.008","volume":"79","author":"Z Meng","year":"2024","unstructured":"Meng Z, Guo Y, Deng S, Xiang Q, Cao J, Zhang Y, Zhang K, Ma K, Xie S, Kang Z (2024) Improving image quality of triple-low-protocol renal artery CT angiography with deep-learning image reconstruction: a comparative study with standard-dose single-energy and dual-energy CT with adaptive statistical iterative reconstruction. Clin Radiol 79:e651\u2013e658. https:\/\/doi.org\/10.1016\/j.crad.2024.01.008","journal-title":"Clin Radiol"},{"key":"3803_CR22","doi-asserted-by":"publisher","first-page":"2979","DOI":"10.1007\/s00261-024-04221-y","volume":"49","author":"X Lin","year":"2024","unstructured":"Lin X, Gao Y, Zhu C, Song J, Liu L, Li J, Wu X (2024) Improved overall image quality in low-dose dual-energy computed tomography enterography using deep-learning image reconstruction. Abdom Radiol 49:2979\u20132987. https:\/\/doi.org\/10.1007\/s00261-024-04221-y","journal-title":"Abdom Radiol"},{"key":"3803_CR23","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s10278-023-00901-1","volume":"37","author":"J Zhong","year":"2024","unstructured":"Zhong J, Wu Z, Wang L, Chen Y, Xia Y, Wang L, Li J, Lu W, Shi X, Feng J, Dong H, Zhang H, Yao W (2024) Impacts of adaptive statistical iterative reconstruction-V and deep learning image reconstruction algorithms on robustness of CT radiomics features: opportunity for minimizing radiomics variability among scans of different dose levels. J Imaging Inform Med 37:123\u2013133. https:\/\/doi.org\/10.1007\/s10278-023-00901-1","journal-title":"J Imaging Inform Med"},{"key":"3803_CR24","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1161\/ATVBAHA.119.313830","volume":"40","author":"P Jiang","year":"2020","unstructured":"Jiang P, Chen Z, Hippe DS, Watase H, Sun B, Lin R, Yang Z, Xue Y, Zhao X, Yuan C (2020) Association between carotid bifurcation geometry and atherosclerotic plaque vulnerability: a Chinese atherosclerosis risk evaluation study. Arterioscler Thromb Vasc Biol 40:1383\u20131391. https:\/\/doi.org\/10.1161\/ATVBAHA.119.313830","journal-title":"Arterioscler Thromb Vasc Biol"},{"key":"3803_CR25","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1186\/s12968-020-00657-5","volume":"22","author":"C Strecker","year":"2020","unstructured":"Strecker C, Krafft AJ, Kaufhold L, H\u00fcllebrandt M, Weber S, Ludwig U, Wolkewitz M, Hennemuth A, Hennig J, Harloff A (2020) Carotid geometry is an independent predictor of wall thickness\u2013a 3D cardiovascular magnetic resonance study in patients with high cardiovascular risk. J Cardiovasc Magn Reson 22:67. https:\/\/doi.org\/10.1186\/s12968-020-00657-5","journal-title":"J Cardiovasc Magn Reson"},{"key":"3803_CR26","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1007\/s00330-022-09025-6","volume":"33","author":"L Saba","year":"2023","unstructured":"Saba L, Loewe C, Weikert T, Williams MC, Galea N, Budde RPJ, Vliegenthart R, Velthuis BK, Francone M, Bremerich J, Natale L, Nikolaou K, Dacher JN, Peebles C, Caobelli F, Redheuil A, Dewey M, Kreitner KF, Salgado R (2023) State-of-the-art CT and MR imaging and assessment of atherosclerotic carotid artery disease: the reporting\u2014a consensus document by the European Society of Cardiovascular Radiology (ESCR). Eur Radiol 33:1088\u20131101. https:\/\/doi.org\/10.1007\/s00330-022-09025-6","journal-title":"Eur Radiol"},{"key":"3803_CR27","doi-asserted-by":"publisher","first-page":"e14356","DOI":"10.1002\/acm2.14356","volume":"25","author":"IA Tsalafoutas","year":"2024","unstructured":"Tsalafoutas IA, Alkhazzam S, Kharita MH (2024) The impact of automatic tube current modulation related settings of a modern GE CT scanner on image quality and patient dose; details do matter. J Appl Clin Med Phys 25:e14356. https:\/\/doi.org\/10.1002\/acm2.14356","journal-title":"J Appl Clin Med Phys"}],"container-title":["Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-025-03803-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00234-025-03803-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-025-03803-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T06:42:55Z","timestamp":1777876975000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00234-025-03803-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,17]]},"references-count":27,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,4]]}},"alternative-id":["3803"],"URL":"https:\/\/doi.org\/10.1007\/s00234-025-03803-x","relation":{},"ISSN":["0028-3940","1432-1920"],"issn-type":[{"value":"0028-3940","type":"print"},{"value":"1432-1920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,17]]},"assertion":[{"value":"15 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Consent to participate: Informed consent was obtained from all individual participants included in the study. All enrolled patients provided informed consent in accordance with the Helsinki Declaration. The study was approved by the institution\u2019s ethics committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors affirm that human research participants provided informed consent for publication of the images in Fig.\u00a0\n                      \n                      , Supplementary Fig.\u00a0\n                      \n                      and Supplementary Fig.\u00a0\n                      \n                      .","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}