{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T07:06:04Z","timestamp":1789455964162,"version":"build-2803163510"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T00:00:00Z","timestamp":1771459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T00:00:00Z","timestamp":1771459200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neuroradiology"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1007\/s00234-026-03930-z","type":"journal-article","created":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T09:39:44Z","timestamp":1771493984000},"page":"2343-2352","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Optimizing virtual monoenergetic imaging for dual\u2011energy CT venography assessment of intracranial venous sinus stents"],"prefix":"10.1007","volume":"68","author":[{"given":"Joel","family":"Kosowan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy Reynold","family":"Lim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akhil","family":"Nair","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asutosh","family":"Sahu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vinu","family":"Mathew","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yingming Amy","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vitor Mendes","family":"Pereira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicole","family":"Cancelliere","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shobhit","family":"Mathur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,19]]},"reference":[{"key":"3930_CR1","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1136\/neurintsurg-2021-018184","volume":"14","author":"KM Fargen","year":"2022","unstructured":"Fargen KM (2022) Venous stenting for idiopathic intracranial hypertension: lessons learned from a high-volume practice. J Neurointerv Surg 14:528\u2013532. https:\/\/doi.org\/10.1136\/neurintsurg-2021-018184","journal-title":"J Neurointerv Surg"},{"key":"3930_CR2","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1097\/WNO.0000000000001898","volume":"43","author":"MJ Dinkin","year":"2023","unstructured":"Dinkin MJ, Patsalides A (2023) Idiopathic intracranial venous hypertension: toward a better understanding of venous stenosis and the role of stenting in idiopathic intracranial hypertension. J Neuroophthalmol 43:451\u2013463. https:\/\/doi.org\/10.1097\/WNO.0000000000001898","journal-title":"J Neuroophthalmol"},{"key":"3930_CR3","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.1136\/neurintsurg-2018-014042","volume":"10","author":"KM Fargen","year":"2018","unstructured":"Fargen KM, Liu K, Garner RM et al (2018) Recommendations for the selection and treatment of patients with idiopathic intracranial hypertension for venous sinus stenting. J Neurointerv Surg 10:1203\u20131208. https:\/\/doi.org\/10.1136\/neurintsurg-2018-014042","journal-title":"J Neurointerv Surg"},{"key":"3930_CR4","doi-asserted-by":"publisher","first-page":"1126","DOI":"10.3171\/2016.8.JNS16879","volume":"127","author":"KC Liu","year":"2017","unstructured":"Liu KC, Starke RM, Durst CR et al (2017) Venous sinus stenting for reduction of intracranial pressure in IIH: a prospective pilot study. J Neurosurg 127:1126\u20131133. https:\/\/doi.org\/10.3171\/2016.8.JNS16879","journal-title":"J Neurosurg"},{"key":"3930_CR5","doi-asserted-by":"publisher","first-page":"E11","DOI":"10.3171\/2018.5.FOCUS18102","volume":"45","author":"JM Cappuzzo","year":"2018","unstructured":"Cappuzzo JM, Hess RM, Morrison JF et al (2018) Transverse venous stenting for the treatment of idiopathic intracranial hypertension, or pseudotumor cerebri. Neurosurg Focus 45:E11. https:\/\/doi.org\/10.3171\/2018.5.FOCUS18102","journal-title":"Neurosurg Focus"},{"key":"3930_CR6","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1227\/neu.0000000000002718","volume":"94","author":"J Lim","year":"2024","unstructured":"Lim J, Monteiro A, Kuo CC et al (2024) Stenting for venous sinus stenosis in patients with idiopathic intracranial hypertension: an updated systematic review and meta-analysis of the literature. Neurosurgery 94:648\u2013656. https:\/\/doi.org\/10.1227\/neu.0000000000002718","journal-title":"Neurosurgery"},{"key":"3930_CR7","doi-asserted-by":"publisher","first-page":"122948","DOI":"10.1016\/j.jns.2024.122948","volume":"459","author":"AY Azzam","year":"2024","unstructured":"Azzam AY, Mortezaei A, Morsy MM et al (2024) Venous sinus stenting for idiopathic intracranial hypertension: an updated Meta-analysis. J Neurol Sci 459:122948. https:\/\/doi.org\/10.1016\/j.jns.2024.122948","journal-title":"J Neurol Sci"},{"key":"3930_CR8","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1136\/neurintsurg-2018-014172","volume":"11","author":"P Nicholson","year":"2019","unstructured":"Nicholson P, Brinjikji W, Radovanovic I et al (2019) Venous sinus stenting for idiopathic intracranial hypertension: a systematic review and meta-analysis. J Neurointerv Surg 11:380\u2013385. https:\/\/doi.org\/10.1136\/neurintsurg-2018-014172","journal-title":"J Neurointerv Surg"},{"key":"3930_CR9","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1177\/1591019920974185","volume":"27","author":"A Patsalides","year":"2021","unstructured":"Patsalides A, Santillan A, Sundararajan SH et al (2021) Venous sinus stenting for the treatment of isolated pulsatile tinnitus: results of a prospective trial. Interv Neuroradiol 27:266\u2013274. https:\/\/doi.org\/10.1177\/1591019920974185","journal-title":"Interv Neuroradiol"},{"key":"3930_CR10","doi-asserted-by":"publisher","first-page":"e992","DOI":"10.1016\/j.wneu.2024.08.048","volume":"190","author":"D Schartz","year":"2024","unstructured":"Schartz D, Finkelstein A, Akkipeddi SMK et al (2024) Outcomes of pulsatile tinnitus after cerebral venous sinus stenting: systematic review and pooled analysis of 616 patients. World Neurosurg 190:e992\u2013e999. https:\/\/doi.org\/10.1016\/j.wneu.2024.08.048","journal-title":"World Neurosurg"},{"key":"3930_CR11","doi-asserted-by":"publisher","first-page":"81","DOI":"10.25259\/SNI_1_2021","volume":"12","author":"B Fiani","year":"2021","unstructured":"Fiani B, Kondilis A, Doan T et al (2021) Venous sinus stenting for intractable pulsatile tinnitus: A review of indications and outcomes. Surg Neurol Int 12:81. https:\/\/doi.org\/10.25259\/SNI_1_2021","journal-title":"Surg Neurol Int"},{"key":"3930_CR12","doi-asserted-by":"publisher","unstructured":"Townsend RK, Jost A, Amans MR et al (2022) Major complications of dural venous sinus stenting for idiopathic intracranial hypertension: case series and management considerations. J Neurointerv Surg 14. https:\/\/doi.org\/10.1136\/neurintsurg-2021-017361","DOI":"10.1136\/neurintsurg-2021-017361"},{"key":"3930_CR13","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1148\/radiology.198.1.8539371","volume":"198","author":"SO Casey","year":"1996","unstructured":"Casey SO, Alberico RA, Patel M et al (1996) Cerebral CT venography. Radiology 198:163\u2013170. https:\/\/doi.org\/10.1148\/radiology.198.1.8539371","journal-title":"Radiology"},{"key":"3930_CR14","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1136\/neurintsurg-2020-016456","volume":"13","author":"DP Shlapak","year":"2021","unstructured":"Shlapak DP, Lanzino G, Morris PP et al (2021) Utility of CT venography in monitoring stent patency in idiopathic intracranial hypertension: retrospective single-center study. J Neurointerv Surg 13:478\u2013482. https:\/\/doi.org\/10.1136\/neurintsurg-2020-016456","journal-title":"J Neurointerv Surg"},{"key":"3930_CR15","first-page":"1813","volume":"26","author":"G Benndorf","year":"2005","unstructured":"Benndorf G, Strother CM, Claus B et al (2005) Angiographic CT in cerebrovascular stenting. AJNR Am J Neuroradiol 26:1813\u20131818","journal-title":"AJNR Am J Neuroradiol"},{"key":"3930_CR16","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1007\/s00234-011-1002-8","volume":"54","author":"F Claren\u00e7on","year":"2012","unstructured":"Claren\u00e7on F, Piotin M, Pistocchi S et al (2012) Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms. Neuroradiology 54:1121\u20131125. https:\/\/doi.org\/10.1007\/s00234-011-1002-8","journal-title":"Neuroradiology"},{"key":"3930_CR17","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1136\/neurintsurg-2020-015949","volume":"13","author":"A El Mekabaty","year":"2021","unstructured":"El Mekabaty A, Pearl MS, Moghekar A, Gailloud P (2021) Mid-term assessment of transverse sinus stent patency in 104 patients treated for intracranial hypertension secondary to dural sinus stenosis. J Neurointerv Surg 13:182\u2013186. https:\/\/doi.org\/10.1136\/neurintsurg-2020-015949","journal-title":"J Neurointerv Surg"},{"key":"3930_CR18","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1148\/rg.2016150185","volume":"36","author":"H Machida","year":"2016","unstructured":"Machida H, Tanaka I, Fukui R et al (2016) Dual-energy spectral CT: various clinical vascular applications. Radiographics 36:1215\u20131232. https:\/\/doi.org\/10.1148\/rg.2016150185","journal-title":"Radiographics"},{"key":"3930_CR19","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1148\/radiol.2019182297","volume":"293","author":"MH Albrecht","year":"2019","unstructured":"Albrecht MH, Vogl TJ, Martin SS et al (2019) Review of clinical applications for virtual monoenergetic dual-energy CT. Radiology 293:260\u2013271. https:\/\/doi.org\/10.1148\/radiol.2019182297","journal-title":"Radiology"},{"key":"3930_CR20","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/s00234-018-1981-9","volume":"60","author":"S Winklhofer","year":"2018","unstructured":"Winklhofer S, Hinzpeter R, Stocker D et al (2018) Combining monoenergetic extrapolations from dual-energy CT with iterative reconstructions: reduction of coil and clip artifacts from intracranial aneurysm therapy. Neuroradiology 60:281\u2013291. https:\/\/doi.org\/10.1007\/s00234-018-1981-9","journal-title":"Neuroradiology"},{"key":"3930_CR21","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1007\/s00330-022-09073-y","volume":"33","author":"N Schmitt","year":"2022","unstructured":"Schmitt N, Wucherpfennig L, Rotkopf LT et al (2022) Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT \u2014 in vitro comparison of a standard brain imaging protocol. Eur Radiol 33:803\u2013811. https:\/\/doi.org\/10.1007\/s00330-022-09073-y","journal-title":"Eur Radiol"},{"key":"3930_CR22","doi-asserted-by":"publisher","first-page":"1229","DOI":"10.1136\/jnis-2024-022041","volume":"17","author":"R Ludovichetti","year":"2025","unstructured":"Ludovichetti R, Gorup D, Krepuska M et al (2025) Ultra-high resolution CT angiography for the assessment of intracranial stents and flow diverters using photon counting detector CT. J Neurointerv Surg 17:1229\u20131235. https:\/\/doi.org\/10.1136\/jnis-2024-022041","journal-title":"J Neurointerv Surg"},{"key":"3930_CR23","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1016\/j.acra.2019.07.022","volume":"27","author":"D Zhang","year":"2020","unstructured":"Zhang D, Xie Y, Wang Y et al (2020) Initial clinical experience of virtual monoenergetic imaging improves stent visualization in lower extremity run-off CT angiography by dual-layer spectral detector CT. Acad Radiol 27:825\u2013832. https:\/\/doi.org\/10.1016\/j.acra.2019.07.022","journal-title":"Acad Radiol"},{"key":"3930_CR24","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1007\/s00330-016-4422-3","volume":"27","author":"SS Martin","year":"2017","unstructured":"Martin SS, Albrecht MH, Wichmann JL et al (2017) Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement. Eur Radiol 27:705\u2013714. https:\/\/doi.org\/10.1007\/s00330-016-4422-3","journal-title":"Eur Radiol"},{"key":"3930_CR25","doi-asserted-by":"publisher","first-page":"520","DOI":"10.21037\/qims.2017.10.07","volume":"7","author":"A Almutairi","year":"2017","unstructured":"Almutairi A, Al Safran Z, AlZaabi SA, Sun Z (2017) Dual energy CT angiography in peripheral arterial stents: optimal scanning protocols with regard to image quality and radiation dose. Quant Imaging Med Surg 7:520\u2013531. https:\/\/doi.org\/10.21037\/qims.2017.10.07","journal-title":"Quant Imaging Med Surg"},{"key":"3930_CR26","doi-asserted-by":"publisher","first-page":"516","DOI":"10.3174\/ajnr.A6952","volume":"42","author":"C Zaeske","year":"2021","unstructured":"Zaeske C, Hickethier T, Borggrefe J et al (2021) Postinterventional assessment after stent and flow-diverter implantation using CT: influence of spectral image reconstructions and different device types. AJNR Am J Neuroradiol 42:516\u2013523. https:\/\/doi.org\/10.3174\/ajnr.A6952","journal-title":"AJNR Am J Neuroradiol"},{"key":"3930_CR27","doi-asserted-by":"publisher","unstructured":"Cauley KA, Yorks PJ, Flora S, Fielden SW (2021) The effects of the skull on CT imaging of the brain: a skull and brain Phantom study. Br J Radiol 94. https:\/\/doi.org\/10.1259\/bjr.20200714","DOI":"10.1259\/bjr.20200714"},{"key":"3930_CR28","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1148\/rg.2018170102","volume":"38","author":"M Katsura","year":"2018","unstructured":"Katsura M, Sato J, Akahane M et al (2018) Current and novel techniques for metal artifact reduction at CT: practical guide for radiologists. Radiographics 38:450\u2013461. https:\/\/doi.org\/10.1148\/rg.2018170102","journal-title":"Radiographics"},{"issue":"1","key":"3930_CR29","doi-asserted-by":"publisher","first-page":"17576","DOI":"10.1038\/s41598-021-97035-7","volume":"11","author":"Q Liu","year":"2021","unstructured":"Liu Q, Wang Y, Qi H et al (2021) Exploring the best monochromatic energy level in dual energy spectral imaging for coronary stents after percutaneous coronary intervention. Sci Rep 11(1):17576","journal-title":"Sci Rep"},{"key":"3930_CR30","doi-asserted-by":"crossref","unstructured":"Rajiah PS, Dunning CAS, Rajendran K et al (2023) High-Pitch multienergy coronary CT angiography in Dual-Source Photon-Counting detector CT scanner at low iodinated contrast dose. Invest Radiol","DOI":"10.1097\/RLI.0000000000000961"},{"key":"3930_CR31","doi-asserted-by":"publisher","first-page":"726","DOI":"10.21037\/qims-21-477","volume":"12","author":"D Cester","year":"2022","unstructured":"Cester D, Eberhard M, Alkadhi H, Euler A (2022) Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance. Quant Imaging Med Surg 12:726\u2013741. https:\/\/doi.org\/10.21037\/qims-21-477","journal-title":"Quant Imaging Med Surg"},{"key":"3930_CR32","doi-asserted-by":"publisher","first-page":"S9","DOI":"10.2214\/AJR.12.9121","volume":"199","author":"L Yu","year":"2012","unstructured":"Yu L, Leng S, McCollough CH (2012) Dual-energy CT\u2013based monochromatic imaging. AJR Am J Roentgenol 199:S9\u2013S15. https:\/\/doi.org\/10.2214\/AJR.12.9121","journal-title":"AJR Am J Roentgenol"},{"key":"3930_CR33","doi-asserted-by":"publisher","first-page":"20180546","DOI":"10.1259\/bjr.20180546","volume":"92","author":"T D\u2019Angelo","year":"2019","unstructured":"D\u2019Angelo T, Cicero G, Mazziotti S et al (2019) Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications. Br J Radiol 92:20180546. https:\/\/doi.org\/10.1259\/bjr.20180546","journal-title":"Br J Radiol"},{"key":"3930_CR34","doi-asserted-by":"publisher","first-page":"175","DOI":"10.5152\/dir.2022.21551","volume":"29","author":"JH Hwang","year":"2023","unstructured":"Hwang JH, Kang JM, Park S et al (2023) Advanced virtual monoenergetic imaging algorithm for lower extremity computed tomography angiography: effects on image quality, artifacts, and peripheral arterial disease evaluation. Diagn Interv Radiol 29:175\u2013182. https:\/\/doi.org\/10.5152\/dir.2022.21551","journal-title":"Diagn Interv Radiol"},{"key":"3930_CR35","doi-asserted-by":"publisher","unstructured":"Kazimierczak W, Kazimierczak N, Serafin Z (2023) Review of clinical applications of Dual-Energy CT in patients after endovascular aortic repair. J Clin Med 12. https:\/\/doi.org\/10.3390\/jcm12247766","DOI":"10.3390\/jcm12247766"},{"key":"3930_CR36","doi-asserted-by":"publisher","first-page":"4239","DOI":"10.1007\/s00330-018-5990-1","volume":"29","author":"L Qin","year":"2019","unstructured":"Qin L, Gu S, Chen C et al (2019) Initial exploration of coronary stent image subtraction using dual-layer spectral CT. Eur Radiol 29:4239\u20134248. https:\/\/doi.org\/10.1007\/s00330-018-5990-1","journal-title":"Eur Radiol"},{"key":"3930_CR37","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1093\/ehjci\/jeu282","volume":"16","author":"J Stehli","year":"2015","unstructured":"Stehli J, Fuchs TA, Singer A (2015) First experience with single-source, dual-energy CCTA for monochromatic stent imaging. Eur Heart J Cardiovasc Imaging 16:507\u201312. https:\/\/doi.org\/10.1093\/ehjci\/jeu282","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"3930_CR38","doi-asserted-by":"publisher","first-page":"e14453","DOI":"10.1002\/acm2.14453","volume":"25","author":"J Cammin","year":"2024","unstructured":"Cammin J (2024) A robust index for metal artifact quantification in computed tomography. J Appl Clin Med Phys 25:e14453. https:\/\/doi.org\/10.1002\/acm2.14453","journal-title":"J Appl Clin Med Phys"},{"key":"3930_CR39","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/j.rcl.2018.03.001","volume":"56","author":"AJ Megibow","year":"2018","unstructured":"Megibow AJ, Kambadakone A, Ananthakrishnan L (2018) Dual-Energy computed tomography. Radiol Clin North Am 56:507\u2013520. https:\/\/doi.org\/10.1016\/j.rcl.2018.03.001","journal-title":"Radiol Clin North Am"},{"key":"3930_CR40","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1016\/j.rcl.2018.03.002","volume":"56","author":"A Parakh","year":"2018","unstructured":"Parakh A, Macri F, Sahani D (2018) Dual-Energy computed tomography. Radiol Clin North Am 56:601\u2013624. https:\/\/doi.org\/10.1016\/j.rcl.2018.03.002","journal-title":"Radiol Clin North Am"},{"key":"3930_CR41","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1148\/rg.2021200049","volume":"41","author":"A Parakh","year":"2021","unstructured":"Parakh A, An C, Lennartz S (2021) Recognizing and minimizing artifacts at Dual-Energy CT. Radiographics 41:509\u2013523. https:\/\/doi.org\/10.1148\/rg.2021200049","journal-title":"Radiographics"},{"key":"3930_CR42","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1016\/j.wneu.2023.12.128","volume":"184","author":"A Pandey","year":"2024","unstructured":"Pandey A, Schreiber C, Garton ALA (2024) Future directions and innovations in venous sinus stenting. World Neurosurg 184:387\u2013394. https:\/\/doi.org\/10.1016\/j.wneu.2023.12.128","journal-title":"World Neurosurg"}],"container-title":["Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-026-03930-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00234-026-03930-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-026-03930-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T06:11:22Z","timestamp":1789452682000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00234-026-03930-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,19]]},"references-count":42,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["3930"],"URL":"https:\/\/doi.org\/10.1007\/s00234-026-03930-z","relation":{},"ISSN":["0028-3940","1432-1920"],"issn-type":[{"value":"0028-3940","type":"print"},{"value":"1432-1920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,19]]},"assertion":[{"value":"26 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective imaging analysis was conducted as a quality-assurance initiative. Institutional review determined that Research Ethics Board approval and individual informed consent were not required because the project used existing clinically acquired examinations and only de-identified data were analysed. All procedures were performed in accordance with institutional policies and the principles of the Declaration of Helsinki.","order":1,"name":"Ethics","label":"Ethical adherence","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Internal review board (IRB)","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Human ethics and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}