{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T11:14:15Z","timestamp":1790421255422,"version":"4.1.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T00:00:00Z","timestamp":1771372800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T00:00:00Z","timestamp":1771372800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsmedizin Rostock"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neuroradiology"],"published-print":{"date-parts":[[2026,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The Alberta Stroke Program Early CT Score (ASPECTS) and advances in CT reconstruction play important roles in the neurodiagnostic workflow. This study examines the effect of these reconstruction techniques on automated ASPECTS.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this retrospective study, 173 patients (median age 79 years, 39% female) with suspected middle cerebral artery infarction underwent non-contrast CT scans reconstructed with Filtered Back Projection (FBP), ASIR-V (30% and 60%), and DLIR (low, medium, and high). Automated ASPECTS were analyzed, with FBP as the reference standard.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Bland\u2013Altman analysis revealed a mean bias with ASIR and DLIR underestimating ASPECTS compared to FBP. This underestimation was less pronounced for ASIR-V 30% (-0.057 ) and DLIR-L (-0.069) than for ASIR-V 60% (-0.126), DLIR-M (-0.121), and DLIR-H (-0.086). The region with the greatest overestimation relative to FBP was M3 (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200923), while the region with the greatest underestimation was the insular ribbon (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200951). Regarding the ASPECTS\u2009&lt;\u20096 threshold, most patients were reclassified from ASPECTS\u2009\u2264\u20095 to ASPECTS\u2009\u2265\u20096 with DLIR-M (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20095), which also showed the strongest agreement with expert consensus (\u03ba\u2009=\u20090.352).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Both ASIR-V and DLIR resulted in only minor underestimation of ASPECTS compared to FBP. However, most patients became eligible for endovascular therapy due to ASPECTS reclassification with DLIR-M. DLIR-M also exhibited the highest agreement with expert consensus for automated ASPECTS. Therefore, careful selection of reconstruction parameters, as well as further optimization and standardization of these techniques, is essential for broader application in stroke imaging.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00234-026-03938-5","type":"journal-article","created":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T10:48:59Z","timestamp":1771411739000},"page":"953-963","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Influence of deep learning image reconstruction and adaptive statistical iterative reconstruction-V on automated Alberta stroke program early CT score- evaluation"],"prefix":"10.1007","volume":"68","author":[{"given":"Estelle","family":"Akl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Cantr\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"L\u00fctgens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wiebke","family":"Hermann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S\u00f6nke","family":"Langner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc-Andr\u00e9","family":"Weber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ann-Christin","family":"Klemenz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix G.","family":"Meinel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ebba","family":"Beller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,18]]},"reference":[{"key":"3938_CR1","doi-asserted-by":"publisher","first-page":"1260","DOI":"10.1001\/jamaneurol.2022.3285","volume":"79","author":"K Uchida","year":"2022","unstructured":"Uchida K, Shindo S, Yoshimura S et al (2022) Association between Alberta stroke program early computed tomography score and efficacy and safety outcomes with endovascular therapy in patients with stroke from large-Vessel occlusion: A secondary analysis of the recovery by endovascular salvage for cerebral Ultra-acute Embolism\u2014Japan large ischemic core trial (RESCUE-Japan LIMIT). JAMA Neurol 79:1260. https:\/\/doi.org\/10.1001\/jamaneurol.2022.3285","journal-title":"JAMA Neurol"},{"key":"3938_CR2","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1177\/1747493018786616","volume":"13","author":"J Boulanger","year":"2018","unstructured":"Boulanger J, Lindsay M, Gubitz G et al (2018) Canadian stroke best practice recommendations for acute stroke management: Prehospital, emergency Department, and acute inpatient stroke Care, 6th Edition, update 2018. Int J Stroke 13:949\u2013984. https:\/\/doi.org\/10.1177\/1747493018786616","journal-title":"Int J Stroke"},{"key":"3938_CR3","doi-asserted-by":"publisher","unstructured":"Powers WJ, Rabinstein AA, Ackerson T et al (2018) 2018 guidelines for the early management of patients with acute ischemic stroke: A guideline for healthcare professionals from the American heart association\/American stroke association. Stroke 49. https:\/\/doi.org\/10.1161\/STR.0000000000000158","DOI":"10.1161\/STR.0000000000000158"},{"key":"3938_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2021\/5935170","volume":"2021","author":"A Esmael","year":"2021","unstructured":"Esmael A, Elsherief M, Eltoukhy K (2021) Predictive value of the Alberta stroke program early CT score (ASPECTS) in the outcome of the acute ischemic stroke and its correlation with stroke Subtypes, NIHSS, and cognitive impairment. Stroke Res Treat 2021:1\u201310. https:\/\/doi.org\/10.1155\/2021\/5935170","journal-title":"Stroke Res Treat"},{"key":"3938_CR5","doi-asserted-by":"publisher","first-page":"95","DOI":"10.5853\/jos.2023.02292","volume":"26","author":"SS Elawady","year":"2024","unstructured":"Elawady SS, Saway BF, Matsukawa H et al (2024) Thrombectomy in stroke patients with low Alberta stroke program early computed tomography score: is modified thrombolysis in cerebral infarction (mTICI) 2c\/3 superior to mTICI 2b? J Stroke 26:95\u2013103. https:\/\/doi.org\/10.5853\/jos.2023.02292","journal-title":"J Stroke"},{"issue":"10","key":"3938_CR6","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1001\/jamaneurol.2024.2500","volume":"81","author":"H Chen","year":"2024","unstructured":"Chen H, Lee JS, Michel P et al (2024) Endovascular stroke thrombectomy for patients with large ischemic core. JAMA Neurol 81(10):1085\u20131093. https:\/\/doi.org\/10.1001\/jamaneurol.2024.2500","journal-title":"JAMA Neurol"},{"key":"3938_CR7","doi-asserted-by":"publisher","first-page":"20230084","DOI":"10.1259\/bjr.20230084","volume":"96","author":"AA Baig","year":"2023","unstructured":"Baig AA, Bouslama M, Turner RC et al (2023) Mechanical thrombectomy in low Alberta stroke program early CT score (ASPECTS) in hyperacute stroke\u2014a systematic review and meta-analysis. Br J Radiol 96:20230084. https:\/\/doi.org\/10.1259\/bjr.20230084","journal-title":"Br J Radiol"},{"key":"3938_CR8","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1161\/STROKEAHA.124.050052","volume":"56","author":"HC Kniep","year":"2025","unstructured":"Kniep HC, Gelli\u00dfen S, Thomalla G et al (2025) Thrombectomy with low ASPECTS: the roles of infarct volume and postacute neurological status. Stroke 56:1116\u20131127. https:\/\/doi.org\/10.1161\/STROKEAHA.124.050052","journal-title":"Stroke"},{"key":"3938_CR9","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3174\/ajnr.A6883","volume":"42","author":"JE Soun","year":"2021","unstructured":"Soun JE, Chow DS, Nagamine M et al (2021) Artificial intelligence and acute stroke imaging. Am J Neuroradiol 42:2\u201311. https:\/\/doi.org\/10.3174\/ajnr.A6883","journal-title":"Am J Neuroradiol"},{"key":"3938_CR10","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1148\/radiol.2019181228","volume":"291","author":"C Maegerlein","year":"2019","unstructured":"Maegerlein C, Fischer J, M\u00f6nch S et al (2019) Automated calculation of the Alberta stroke program early CT score: feasibility and reliability. Radiology 291:141\u2013148. https:\/\/doi.org\/10.1148\/radiol.2019181228","journal-title":"Radiology"},{"key":"3938_CR11","doi-asserted-by":"publisher","first-page":"1418060","DOI":"10.3389\/fneur.2024.1418060","volume":"15","author":"Y Liu","year":"2024","unstructured":"Liu Y, Wen Z, Wang Y et al (2024) Artificial intelligence in ischemic stroke images: current applications and future directions. Front Neurol 15:1418060. https:\/\/doi.org\/10.3389\/fneur.2024.1418060","journal-title":"Front Neurol"},{"key":"3938_CR12","doi-asserted-by":"publisher","first-page":"e221257","DOI":"10.1148\/radiol.221257","volume":"306","author":"LR Koetzier","year":"2023","unstructured":"Koetzier LR, Mastrodicasa D, Szczykutowicz TP et al (2023) Deep learning image reconstruction for CT: technical principles and clinical prospects. Radiology 306:e221257. https:\/\/doi.org\/10.1148\/radiol.221257","journal-title":"Radiology"},{"key":"3938_CR13","doi-asserted-by":"publisher","unstructured":"Willemink MJ, de Jong PA, Leiner T (2013) Iterative reconstruction techniques for computed tomography part 1: technical principles. Eur Radio 23(6):1623\u201331. https:\/\/doi.org\/10.1007\/s00330-012-2765-y","DOI":"10.1007\/s00330-012-2765-y"},{"key":"3938_CR14","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.3390\/diagnostics11112037","volume":"11","author":"A Heinrich","year":"2021","unstructured":"Heinrich A, Streckenbach F, Beller E et al (2021) Deep Learning-Based image reconstruction for CT angiography of the aorta. Diagnostics 11:2037. https:\/\/doi.org\/10.3390\/diagnostics11112037","journal-title":"Diagnostics"},{"key":"3938_CR15","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1007\/s00234-020-02574-x","volume":"63","author":"I Kim","year":"2021","unstructured":"Kim I, Kang H, Yoon HJ et al (2021) Deep learning\u2013based image reconstruction for brain CT: improved image quality compared with adaptive statistical iterative reconstruction-Veo (ASIR-V). Neuroradiology 63:905\u2013912. https:\/\/doi.org\/10.1007\/s00234-020-02574-x","journal-title":"Neuroradiology"},{"key":"3938_CR16","doi-asserted-by":"publisher","unstructured":"Prakash P, Kalra MK, Digumarthy SR et al (2010) Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique initial experience. J Comput Assist Tomogr 34(1):40\u20135. https:\/\/doi.org\/10.1097\/RCT.0b013e3181b26c67","DOI":"10.1097\/RCT.0b013e3181b26c67"},{"key":"3938_CR17","doi-asserted-by":"publisher","first-page":"e13796","DOI":"10.1002\/acm2.13796","volume":"23","author":"Q Tian","year":"2022","unstructured":"Tian Q, Li X, Li J et al (2022) Image quality improvement in low-dose chest CT with deep learning image reconstruction. J Appl Clin Med Phys 23:e13796. https:\/\/doi.org\/10.1002\/acm2.13796","journal-title":"J Appl Clin Med Phys"},{"key":"3938_CR18","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1016\/S1474-4422(18)30242-4","volume":"17","author":"alR Luis","year":"2018","unstructured":"Luis alR, SanBerkhemer, Olvert A et (2018) Imaging features and safety and efficacy of endovascular stroke treatment: a meta-analysis of individual patient-level data. Lancet Neurol 17:895\u2013904","journal-title":"Lancet Neurol"},{"key":"3938_CR19","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1161\/STROKEAHA.113.004260","volume":"45","author":"AJ Yoo","year":"2014","unstructured":"Yoo AJ, Zaidat OO, Chaudhry ZA et al (2014) Impact of pretreatment Noncontrast CT Alberta stroke program early CT score on clinical outcome after Intra-Arterial stroke therapy. Stroke 45:746\u2013751. https:\/\/doi.org\/10.1161\/STROKEAHA.113.004260","journal-title":"Stroke"},{"key":"3938_CR20","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1177\/17474930241273561","volume":"20","author":"C Kaveeta","year":"2025","unstructured":"Kaveeta C, Alhabli I, Bala F et al (2025) The treatment effect across ASPECTS in acute ischemic stroke: analysis from the act trial. Int J Stroke 20:64\u201374. https:\/\/doi.org\/10.1177\/17474930241273561","journal-title":"Int J Stroke"},{"key":"3938_CR21","doi-asserted-by":"publisher","first-page":"2259","DOI":"10.1016\/j.acra.2024.03.020","volume":"31","author":"A-C Klemenz","year":"2024","unstructured":"Klemenz A-C, Beckert L, Manzke M et al (2024) Influence of deep learning based image reconstruction on quantitative results of coronary artery calcium scoring. Acad Radiol 31:2259\u20132267. https:\/\/doi.org\/10.1016\/j.acra.2024.03.020","journal-title":"Acad Radiol"},{"key":"3938_CR22","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-025-03733-8","author":"M Pula","year":"2025","unstructured":"Pula M, Kucharczyk E, Piersiak M et al (2025) Improved CTA imaging for stroke evaluation \u2013 deep learning and iterative reconstruction comparative study. Neuroradiology. https:\/\/doi.org\/10.1007\/s00234-025-03733-8","journal-title":"Neuroradiology"},{"key":"3938_CR23","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1007\/s00261-021-03373-5","volume":"47","author":"M Nishikawa","year":"2022","unstructured":"Nishikawa M, Machida H, Shimizu Y et al (2022) Image quality and radiologists\u2019 subjective acceptance using model-based iterative and deep learning reconstructions as adjuncts to ultrahigh-resolution CT in low-dose contrast-enhanced abdominopelvic CT: Phantom and clinical pilot studies. Abdom Radiol 47:891\u2013902. https:\/\/doi.org\/10.1007\/s00261-021-03373-5","journal-title":"Abdom Radiol"},{"key":"3938_CR24","doi-asserted-by":"publisher","first-page":"1534","DOI":"10.3390\/diagnostics13091534","volume":"13","author":"S Altmann","year":"2023","unstructured":"Altmann S, Abello Mercado MA, Ucar FA et al (2023) Ultra-High-Resolution CT of the head and neck with deep learning Reconstruction\u2014Assessment of image quality and radiation exposure and intraindividual comparison with Normal-Resolution CT. Diagnostics 13:1534. https:\/\/doi.org\/10.3390\/diagnostics13091534","journal-title":"Diagnostics"},{"key":"3938_CR25","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1186\/s12880-021-00637-w","volume":"21","author":"J Sun","year":"2021","unstructured":"Sun J, Li H, Wang B et al (2021) Application of a deep learning image reconstruction (DLIR) algorithm in head CT imaging for children to improve image quality and lesion detection. BMC Med Imaging 21:108. https:\/\/doi.org\/10.1186\/s12880-021-00637-w","journal-title":"BMC Med Imaging"},{"key":"3938_CR26","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1007\/s10140-021-02012-2","volume":"29","author":"Z Alagic","year":"2022","unstructured":"Alagic Z, Diaz Cardenas J, Halldorsson K et al (2022) Deep learning versus iterative image reconstruction algorithm for head CT in trauma. Emerg Radiol 29:339\u2013352. https:\/\/doi.org\/10.1007\/s10140-021-02012-2","journal-title":"Emerg Radiol"},{"key":"3938_CR27","doi-asserted-by":"publisher","first-page":"20220625","DOI":"10.1259\/bjr.20220625","volume":"96","author":"X Huang","year":"2023","unstructured":"Huang X, Zhao W, Wang G et al (2023) Improving image quality with deep learning image reconstruction in double-low-dose head CT angiography compared with standard dose and adaptive statistical iterative reconstruction. Br J Radiol 96:20220625. https:\/\/doi.org\/10.1259\/bjr.20220625","journal-title":"Br J Radiol"},{"key":"3938_CR28","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1136\/neurintsurg-2019-015442","volume":"12","author":"A Neuhaus","year":"2020","unstructured":"Neuhaus A, Seyedsaadat SM, Mihal D et al (2020) Region-specific agreement in ASPECTS Estimation between neuroradiologists and e-ASPECTS software. J NeuroInterventional Surg 12:720\u2013724. https:\/\/doi.org\/10.1136\/neurintsurg-2019-015442","journal-title":"J NeuroInterventional Surg"},{"key":"3938_CR29","doi-asserted-by":"publisher","first-page":"6285","DOI":"10.1007\/s00330-019-06252-2","volume":"29","author":"F Austein","year":"2019","unstructured":"Austein F, Wodarg F, J\u00fcrgensen N et al (2019) Automated versus manual imaging assessment of early ischemic changes in acute stroke: comparison of two software packages and expert consensus. Eur Radiol 29:6285\u20136292. https:\/\/doi.org\/10.1007\/s00330-019-06252-2","journal-title":"Eur Radiol"},{"key":"3938_CR30","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1177\/15910199211011861","volume":"27","author":"M Waleed Brinjikji","year":"2021","unstructured":"Waleed Brinjikji M, Abbasi C, Arnold et al (2021) E-ASPECTS software improves interobserver agreement and accuracy of interpretation of aspects score. Interv Neuroradiol 27:781","journal-title":"Interv Neuroradiol"},{"key":"3938_CR31","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1111\/jon.12810","volume":"31","author":"MT L\u00f6ffler","year":"2021","unstructured":"L\u00f6ffler MT, Sollmann N, M\u00f6nch S et al (2021) Improved reliability of automated ASPECTS evaluation using iterative model reconstruction from head CT scans. J Neuroimaging 31:341\u2013347. https:\/\/doi.org\/10.1111\/jon.12810","journal-title":"J Neuroimaging"},{"key":"3938_CR32","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1111\/jon.12562","volume":"29","author":"J Fatih Seker","year":"2018","unstructured":"Fatih Seker J, Pfaff S, Nagel et al (2018) CT reconstruction levels affect automated and Reader-Based ASPECTS ratings in acute ischemic stroke. J Neuroimaging 29:62\u201364","journal-title":"J Neuroimaging"},{"key":"3938_CR33","doi-asserted-by":"publisher","unstructured":"Konno M, Otani T, Matsuda M et al (2025) Deep learning-based computed tomography reconstruction improves image quality but does not significantly affect Alberta stroke program early CT score evaluation in acute middle cerebral artery territory infarction. Neuroradiology. https:\/\/doi.org\/10.1007\/s00234-025-03804-w","DOI":"10.1007\/s00234-025-03804-w"},{"key":"3938_CR34","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1007\/s00062-020-00988-x","volume":"31","author":"N Van Horn","year":"2021","unstructured":"Van Horn N, Kniep H, Broocks G et al (2021) ASPECTS interobserver agreement of 100 investigators from the TENSION study. Clin Neuroradiol 31:1093\u20131100. https:\/\/doi.org\/10.1007\/s00062-020-00988-x","journal-title":"Clin Neuroradiol"},{"key":"3938_CR35","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1055\/s-0041-107200","volume":"188","author":"D Kaul","year":"2015","unstructured":"Kaul D, Kahn J, Huizing L et al (2015) Reducing radiation dose in adult head CT using iterative Reconstruction \u2013 A clinical study in 177 Patients. R\u00f6Fo - Fortschritte auf dem geb R\u00f6ntgenstrahlen. Bildgeb Verfahr 188:155\u2013162. https:\/\/doi.org\/10.1055\/s-0041-107200","journal-title":"Bildgeb Verfahr"},{"key":"3938_CR36","doi-asserted-by":"publisher","first-page":"3253","DOI":"10.1007\/s00330-023-09559-3","volume":"33","author":"Y Nagayama","year":"2023","unstructured":"Nagayama Y, Iwashita K, Maruyama N et al (2023) Deep learning-based reconstruction can improve the image quality of low radiation dose head CT. Eur Radiol 33:3253\u20133265. https:\/\/doi.org\/10.1007\/s00330-023-09559-3","journal-title":"Eur Radiol"}],"container-title":["Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-026-03938-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00234-026-03938-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-026-03938-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T06:43:01Z","timestamp":1777876981000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00234-026-03938-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,18]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,4]]}},"alternative-id":["3938"],"URL":"https:\/\/doi.org\/10.1007\/s00234-026-03938-5","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-7904400\/v1","asserted-by":"object"}]},"ISSN":["0028-3940","1432-1920"],"issn-type":[{"value":"0028-3940","type":"print"},{"value":"1432-1920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,18]]},"assertion":[{"value":"20 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human ethics and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}