{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T08:04:43Z","timestamp":1789718683885,"version":"4.0.1"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neuroradiology"],"DOI":"10.1007\/s00234-026-04194-3","type":"journal-article","created":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T07:56:50Z","timestamp":1789718210000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Selective embolization of an uncatheterizable trans-osseous feeder using a dual-balloon pressure cooker technique: technical note"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8662-3588","authenticated-orcid":false,"given":"Vishnu","family":"Suresh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6882-9339","authenticated-orcid":false,"given":"Siddharth","family":"Srinivasan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Opperman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Surdell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Thorell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mithun","family":"Sattur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas","family":"Borg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,18]]},"reference":[{"issue":"1","key":"4194_CR1","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.neurad.2013.10.001","volume":"41","author":"R Chapot","year":"2014","unstructured":"Chapot R, Stracke P, Velasco A, Nordmeyer H, Heddier M, Stauder M et al (2014) The pressure cooker technique for the treatment of brain AVMs. J Neuroradiol 41(1):87\u201391. https:\/\/doi.org\/10.1016\/j.neurad.2013.10.001 PubMed PMID: 24405685","journal-title":"J Neuroradiol"},{"key":"4194_CR2","doi-asserted-by":"publisher","first-page":"e119","DOI":"10.1016\/j.wneu.2024.05.180","volume":"189","author":"A Kaul","year":"2024","unstructured":"Kaul A, Roy JM, El Naamani K, Ahmed MT, Carreras A, Mouchtouris N et al (2024) Use of the Scepter Dual-Lumen Balloon Catheter for Transarterial Onyx Embolization of Cranial Dural Arteriovenous Fistulas. World Neurosurg 189:e119\u2013e125. https:\/\/doi.org\/10.1016\/j.wneu.2024.05.180 PubMed PMID: 38848993","journal-title":"World Neurosurg"},{"issue":"(2 Suppl Operat","key":"4194_CR3","doi-asserted-by":"publisher","first-page":"ons238","DOI":"10.1227\/NEU.0000000000000186","volume":"73","author":"BD Jagadeesan","year":"2013","unstructured":"Jagadeesan BD, Grigoryan M, Hassan AE, Grande AW, Tummala RP (2013) Endovascular balloon-assisted embolization of intracranial and cervical arteriovenous malformations using dual-lumen coaxial balloon microcatheters and Onyx: initial experience. Neurosurgery 73(2 Suppl Operative):ons238-43; discussion ons243. https:\/\/doi.org\/10.1227\/NEU.0000000000000186. PMID: 24077579.","journal-title":"Neurosurgery"},{"issue":"4","key":"4194_CR4","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.neurad.2013.08.001","volume":"40","author":"S Paramasivam","year":"2013","unstructured":"Paramasivam S, Niimi Y, Fifi J, Berenstein A (2013) Onyx embolization using dual-lumen balloon catheter: initial experience and technical note. J Neuroradiol 40(4):294\u2013302. https:\/\/doi.org\/10.1016\/j.neurad.2013.08.001 PubMed PMID: 24074560","journal-title":"J Neuroradiol"},{"issue":"7","key":"4194_CR5","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1136\/neurintsurg-2013-010833","volume":"6","author":"AM Spiotta","year":"2014","unstructured":"Spiotta AM, Miranpuri AS, Vargas J, Magarick J, Turner RD, Turk AS et al (2014) Balloon augmented Onyx embolization utilizing a dual lumen balloon catheter: utility in the treatment of a variety of head and neck lesions. J Neurointerv Surg 6(7):547\u2013555. https:\/\/doi.org\/10.1136\/neurintsurg-2013-010833 PubMed PMID: 24026949","journal-title":"J Neurointerv Surg"},{"issue":"1","key":"4194_CR6","first-page":"172","volume":"28","author":"WJ van Rooij","year":"2007","unstructured":"van Rooij WJ, Sluzewski M, Beute GN (2007) Brain AVM Embolization with Onyx. AJNR Am J Neuroradiol 28(1):172\u2013177 PubMed PMID: 17213451; PubMed Central PMCID: PMC8134108","journal-title":"AJNR Am J Neuroradiol"},{"issue":"4","key":"4194_CR7","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s00234-019-02176-2","volume":"61","author":"H Xu","year":"2019","unstructured":"Xu H, Wang L, Guan S, Li D, Quan T (2019) Embolization of brain arteriovenous malformations with the diluted Onyx technique: initial experience. Neuroradiology 61(4):471\u2013478. https:\/\/doi.org\/10.1007\/s00234-019-02176-2 PubMed PMID: 30712140","journal-title":"Neuroradiology"},{"key":"4194_CR8","doi-asserted-by":"publisher","unstructured":"Newman CB, Park MS, Kerber CW, Levy ML, Barr JD, Pakbaz RS (2012) Over-the-catheter retrieval of a retained microcatheter following Onyx embolization: a technical report. J Neurointerv Surg. ;4(4):e13. https:\/\/doi.org\/10.1136\/neurintsurg-2011-010040 PubMed PMID: 21990504","DOI":"10.1136\/neurintsurg-2011-010040"},{"issue":"3","key":"4194_CR9","first-page":"34","volume":"10","author":"M Arslan","year":"2019","unstructured":"Arslan M, C\u0131nar C, Oran I (2019) Dual-Lumen Balloon Catheter Technique for Onyx Embolization of Spinal Dural Arteriovenous Fistula. J Vasc Interv Neurol 10(3):34\u201337 PubMed PMID: 31308869; PubMed Central PMCID: PMC6613489","journal-title":"J Vasc Interv Neurol"},{"issue":"11","key":"4194_CR10","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1136\/neurintsurg-2020-016013","volume":"12","author":"B Pulli","year":"2020","unstructured":"Pulli B, Sussman ES, Mayercik V, Steinberg GK, Do HM, Heit JJ (2020) Initial experience with the Scepter Mini dual-lumen balloon for transophthalmic artery embolization of anterior cranial fossa dural arteriovenous fistulae. J Neurointerv Surg 12(11):1132\u20131136. https:\/\/doi.org\/10.1136\/neurintsurg-2020-016013 PubMed PMID: 32434799","journal-title":"J Neurointerv Surg"}],"container-title":["Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-026-04194-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00234-026-04194-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00234-026-04194-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T07:56:51Z","timestamp":1789718211000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00234-026-04194-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,18]]},"references-count":10,"alternative-id":["4194"],"URL":"https:\/\/doi.org\/10.1007\/s00234-026-04194-3","relation":{},"ISSN":["0028-3940","1432-1920"],"issn-type":[{"value":"0028-3940","type":"print"},{"value":"1432-1920","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,18]]},"assertion":[{"value":"16 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This project was deemed not to constitute human subjects research by the Institutional Review Board (IRB), in accordance with 45 CFR 46.102, and was therefore exempt from full IRB review.","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The requirement for informed consent was waived by the Institutional Review Board.","order":2,"name":"Ethics","label":"Consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The requirement for informed consent was waived by the Institutional Review Board.","order":3,"name":"Ethics","label":"Consent to publish","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}