{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T13:14:15Z","timestamp":1781183655185,"version":"3.54.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2019,1,21]],"date-time":"2019-01-21T00:00:00Z","timestamp":1548028800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Cardiol"],"published-print":{"date-parts":[[2019,4]]},"DOI":"10.1007\/s00246-019-02051-0","type":"journal-article","created":{"date-parts":[[2019,1,21]],"date-time":"2019-01-21T13:55:39Z","timestamp":1548078939000},"page":"713-718","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Usefulness of Electroanatomical Mapping with Contact Force Monitoring for Accessory Pathways Ablation in Pediatric Population"],"prefix":"10.1007","volume":"40","author":[{"given":"Simone","family":"Gulletta","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pasquale","family":"Vergara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Gigli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"D\u2019Angelo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Radinovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carmela","family":"Melania Barbaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola","family":"Trevisi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Della Bella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,1,21]]},"reference":[{"key":"2051_CR1","doi-asserted-by":"publisher","first-page":"1481","DOI":"10.1056\/NEJM199405263302103","volume":"330","author":"JD Kugler","year":"1994","unstructured":"Kugler JD, Danford DA, Deal BJ, Gillette PC, Perry JC, Silka MJ, Van Hare GF, Walsh EP (1994) Radiofrequency catheter ablation for tachyarrhythmias in children and adolescents. The Pediatric Electrophysiology Society. N Engl J Med 330:1481\u20131487","journal-title":"N Engl J Med"},{"key":"2051_CR2","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1093\/europace\/eut082","volume":"15","author":"J Brugada","year":"2013","unstructured":"Brugada J, Blom N, Sarquella-Brugada G, Blomstrom-Lundqvist C, Deanfield J, Janousek J, Abrams D, Bauersfeld U, Brugada R, Drago F, de Groot N, Happonen JM, Hebe J, Yen Ho S, Marijon E, Paul T, Pfammatter JP, Rosenthal E, European Heart Rhythm Association, Association for European Paediatric and Congenital Cardiology (2013) Pharmacological and non-pharmacological therapy for arrhythmias in the pediatric population: EHRA and AEPC-Arrhythmia Working Group joint consensus statement. Europace 15:1337\u20131382","journal-title":"Europace"},{"key":"2051_CR3","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1046\/j.1540-8167.2004.03645.x","volume":"15","author":"GF Hare Van","year":"2004","unstructured":"Van Hare GF, Javitz H, Carmelli D, Saul JP, Tanel RE, Fischbach PS, Kanter RJ, Schaffer M, Dunnigan A, Colan S, Serwer G, Pediatric Electrophysiology Society (2004) Prospective assessment after pediatric cardiac ablation: demographics, medical profiles, and initial outcomes. J Cardiovasc Electrophysiol 15:759\u2013770","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2051_CR4","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1111\/jce.12080","volume":"24","author":"H Mizuno","year":"2013","unstructured":"Mizuno H, Vergara P, Maccabelli G, Trevisi N, Eng SC, Brombin C, Mazzone P, Della Bella P (2013) Contact force monitoring for cardiac mapping in patients with ventricular tachycardia. J Cardiovasc Electrophysiol 24:519\u2013524","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2051_CR5","doi-asserted-by":"publisher","first-page":"2426","DOI":"10.1161\/01.CIR.97.24.2426","volume":"97","author":"JL Smeets","year":"1998","unstructured":"Smeets JL, Ben-Haim SA, Rodriguez LM, Timmermans C, Wellens HJ (1998) New method for nonfluoroscopic endocardial mapping in humans: accuracy assessment and first clinical results. Circulation 97:2426\u20132432","journal-title":"Circulation"},{"key":"2051_CR6","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1093\/oxfordjournals.rpd.a006469","volume":"94","author":"R Padovani","year":"2001","unstructured":"Padovani R, Bernardi G, Malisan MR, Vano E, Morocutti G, Fioretti PM (2001) Patient dose related to the complexity of interventional cardiology procedures. Radiat Prot Dosimetry 94:189\u2013192","journal-title":"Radiat Prot Dosimetry"},{"key":"2051_CR7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1093\/jicru_ndi019","volume":"5","author":"ICRU","year":"2005","unstructured":"ICRU (2005) Patient dosimetry for X rays used in medical imaging. J ICRU 5:1\u2013113","journal-title":"J ICRU"},{"key":"2051_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.03.001","volume":"40","author":"MM Rehani","year":"2010","unstructured":"Rehani MM, Ciraj-Bjelac O, Vano E, Miller DL, Walsh S, Giordano BD, Persliden J (2010) ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department. Ann ICRP 40:1\u2013102","journal-title":"Ann ICRP"},{"key":"2051_CR9","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1093\/europace\/eut254","volume":"16","author":"S Gulletta","year":"2014","unstructured":"Gulletta S, Tsiachris D, Della Bella P (2014) Catheter ablation of an anteroseptal accessory pathway guided by contact force monitoring technology and precise electroanatomical mapping. Europace 16:825","journal-title":"Europace"},{"key":"2051_CR10","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/B978-1-4160-0312-0.50009-8","volume-title":"Catheter ablation of cardiac arrhythmias","author":"K Lin","year":"2006","unstructured":"Lin K, Chen S, Lin Y, Chang K (2006) Irrigated and cooledtip radiofrequency catheter ablation. In: Huang S, Wood M (eds) Catheter ablation of cardiac arrhythmias. WB Saunders, Philadelphia, pp\u00a035\u201348"},{"key":"2051_CR11","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1111\/pace.12268","volume":"36","author":"I Yildirim","year":"2013","unstructured":"Yildirim I, Karagoz T, Ertugrul I, Karagoz AH, Ozer S (2013) Efficacy and safety of cryoablation of parahissian accessory pathways in children: a single institution study. Pacing Clin Electrophysiol 36:1495\u20131502","journal-title":"Pacing Clin Electrophysiol"},{"key":"2051_CR12","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.jacc.2004.10.049","volume":"45","author":"JA Kirsh","year":"2005","unstructured":"Kirsh JA, Gross GJ, O\u2019Connor S, Hamilton RM, Cryocath International Patient Registry (2005) Transcatheter cryoablation of tachyarrhythmias in children: initial experience from an international registry. J Am Coll Cardiol 45:133\u2013136","journal-title":"J Am Coll Cardiol"},{"key":"2051_CR13","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1111\/j.1540-8167.2005.50054.x","volume":"16","author":"T Kriebel","year":"2005","unstructured":"Kriebel T, Broistedt C, Kroll M, Sigler M, Paul T (2005) Efficacy and safety of cryoenergy in the ablation of atrioventricular reentrant tachycardia substrates in children and adolescents. J Cardiovasc Electrophysiol 16:960\u2013966","journal-title":"J Cardiovasc Electrophysiol"},{"key":"2051_CR14","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.hrthm.2011.08.021","volume":"9","author":"KH Kuck","year":"2012","unstructured":"Kuck KH, Reddy VY, Schmidt B, Natale A, Neuzil P, Saoudi N, Kautzner J, Herrera C, Hindricks G, Jais P, Nakagawa H, Lambert H, Shah DC (2012) A novel radiofrequency ablation catheter using contact force sensing: TOCCATA study. Heart Rhythm 9:18\u201323","journal-title":"Heart Rhythm"},{"key":"2051_CR15","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1161\/CIRCEP.110.959429","volume":"4","author":"F Perna","year":"2011","unstructured":"Perna F, Heist EK, Danik SB, Barrett CD, Ruskin JN, Mansour M (2011) Assessment of the catheter tip contact force resulting in cardiac perforation in the swine atria using the force sensing technology. Circ Arrhythm Electrophysiol 4:218\u2013224","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"2051_CR16","doi-asserted-by":"publisher","first-page":"2565","DOI":"10.1161\/01.CIR.102.21.2565","volume":"102","author":"T Yamane","year":"2000","unstructured":"Yamane T, Jais P, Shah DC, Hocini M, Peng JT, Deisenhofer I, Clementy J, Haissaguerre M (2000) Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation. Circulation 102:2565\u20132568","journal-title":"Circulation"},{"key":"2051_CR17","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","volume":"64","author":"A Natale","year":"2014","unstructured":"Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT, Kantipudi C, Mansour MC, Melby DP, Packer DL, Nakagawa H, Zhang B, Stagg RB, Boo LM, Marchlinski FE (2014) Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol 64:647\u2013656","journal-title":"J Am Coll Cardiol"},{"key":"2051_CR18","doi-asserted-by":"publisher","first-page":"1789","DOI":"10.1016\/j.hrthm.2012.07.016","volume":"9","author":"VY Reddy","year":"2012","unstructured":"Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, Jais P, Hindricks G, Peichl P, Yulzari A, Lambert H, Neuzil P, Natale A, Kuck KH (2012) The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. Heart Rhythm 9:1789\u20131795","journal-title":"Heart Rhythm"},{"key":"2051_CR19","first-page":"775","volume":"19","author":"M Das","year":"2017","unstructured":"Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D (2017) Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace 19:775\u2013783","journal-title":"Europace"}],"container-title":["Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00246-019-02051-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-019-02051-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-019-02051-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,10]],"date-time":"2022-09-10T19:03:53Z","timestamp":1662836633000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00246-019-02051-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1,21]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["2051"],"URL":"https:\/\/doi.org\/10.1007\/s00246-019-02051-0","relation":{},"ISSN":["0172-0643","1432-1971"],"issn-type":[{"value":"0172-0643","type":"print"},{"value":"1432-1971","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,1,21]]},"assertion":[{"value":"29 July 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 January 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"Dr. Pasquale Vergara is a consultant for Biosense Webster. Dr. Della Bella is a consultant for St. Jude Medical and has received honoraria for lectures from Biosense Webster, St. Jude Medical, and Biotronik. The other authors have no conflict of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Research Involving Human Participants and\/or Animals"}},{"value":"Parents or their legal representatives provided written informed consent in accordance with local guidelines.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed Consent"}}]}}