{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T07:15:43Z","timestamp":1763018143695},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2019,12,19]],"date-time":"2019-12-19T00:00:00Z","timestamp":1576713600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,12,19]],"date-time":"2019-12-19T00:00:00Z","timestamp":1576713600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Cardiol"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1007\/s00246-019-02270-5","type":"journal-article","created":{"date-parts":[[2019,12,19]],"date-time":"2019-12-19T17:03:36Z","timestamp":1576775016000},"page":"382-388","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Different CMR Imaging Modalities for Native and Patch-Repaired Right Ventricular Outflow Tract Sizing: Impact on Percutaneous Pulmonary Valve Replacement Planning"],"prefix":"10.1007","volume":"41","author":[{"given":"Irene","family":"Ferrari","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nerejda","family":"Shehu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naira","family":"Mkrtchyan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Martinoff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Eicken","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heiko","family":"Stern","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Ewert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Meierhofer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,12,19]]},"reference":[{"issue":"23","key":"2270_CR1","doi-asserted-by":"publisher","first-page":"2915","DOI":"10.1093\/eurheartj\/ehq249","volume":"31","author":"Baumgartner H, Bonhoeffer P, De Groot NM, de Haan F, Deanfield JE, Galie N, Gatzoulis MA, Gohlke-Baerwolf C, Kaemmerer H, Kilner P, Meijboom F, Mulder BJ, Oechslin E, Oliver JM, Serraf A, Szatmari A, Thaulow E, Vouhe PR, Walma E, Task Force on the Management of Grown-up Congenital Heart Disease of the European Society of C, Association for European Paediatric C, Guidelines ESCCfP","year":"2010","unstructured":"Baumgartner H, Bonhoeffer P, De Groot NM, de Haan F, Deanfield JE, Galie N, Gatzoulis MA, Gohlke-Baerwolf C, Kaemmerer H, Kilner P, Meijboom F, Mulder BJ, Oechslin E, Oliver JM, Serraf A, Szatmari A, Thaulow E, Vouhe PR, Walma E, Task Force on the Management of Grown-up Congenital Heart Disease of the European Society of C, Association for European Paediatric C, Guidelines ESCCfP (2010) ESC Guidelines for the management of grown-up congenital heart disease (new version 2010). Eur Heart J 31(23):2915\u20132957. https:\/\/doi.org\/10.1093\/eurheartj\/ehq249","journal-title":"Eur Heart J"},{"issue":"3","key":"2270_CR2","doi-asserted-by":"publisher","first-page":"195","DOI":"10.14503\/THIJ-14-4276","volume":"42","author":"AM Qureshi","year":"2015","unstructured":"Qureshi AM, Prieto LR (2015) Percutaneous pulmonary valve placement. Tex Heart Inst J 42(3):195\u2013201. https:\/\/doi.org\/10.14503\/THIJ-14-4276","journal-title":"Tex Heart Inst J"},{"issue":"1","key":"2270_CR3","doi-asserted-by":"publisher","first-page":"57","DOI":"10.2459\/01.JCM.0000247437.05194.8e","volume":"8","author":"S Khambadkone","year":"2007","unstructured":"Khambadkone S, Nordmeyer J, Bonhoeffer P (2007) Percutaneous implantation of the pulmonary and aortic valves: indications and limitations. J Cardiovasc Med (Hagerstown) 8(1):57\u201361. https:\/\/doi.org\/10.2459\/01.JCM.0000247437.05194.8e","journal-title":"J Cardiovasc Med (Hagerstown)"},{"issue":"20","key":"2270_CR4","doi-asserted-by":"publisher","first-page":"1859","DOI":"10.1016\/j.jacc.2008.08.061","volume":"53","author":"TS Momenah","year":"2009","unstructured":"Momenah TS, El Oakley R, Al Najashi K, Khoshhal S, Al Qethamy H, Bonhoeffer P (2009) Extended application of percutaneous pulmonary valve implantation. J Am Coll Cardiol 53(20):1859\u20131863. https:\/\/doi.org\/10.1016\/j.jacc.2008.08.061","journal-title":"J Am Coll Cardiol"},{"issue":"8\u20139","key":"2270_CR5","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1016\/j.acvd.2012.05.002","volume":"105","author":"Y Boudjemline","year":"2012","unstructured":"Boudjemline Y, Brugada G, Van-Aerschot I, Patel M, Basquin A, Bonnet C, Legendre A, Bonnet D, Iserin L (2012) Outcomes and safety of transcatheter pulmonary valve replacement in patients with large patched right ventricular outflow tracts. Arch Cardiovasc Dis 105(8\u20139):404\u2013413. https:\/\/doi.org\/10.1016\/j.acvd.2012.05.002","journal-title":"Arch Cardiovasc Dis"},{"issue":"11","key":"2270_CR6","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1016\/j.acvd.2014.07.045","volume":"107","author":"S Malekzadeh-Milani","year":"2014","unstructured":"Malekzadeh-Milani S, Ladouceur M, Cohen S, Iserin L, Boudjemline Y (2014) Results of transcatheter pulmonary valvulation in native or patched right ventricular outflow tracts. Arch Cardiovasc Dis 107(11):592\u2013598. https:\/\/doi.org\/10.1016\/j.acvd.2014.07.045","journal-title":"Arch Cardiovasc Dis"},{"issue":"3","key":"2270_CR7","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1161\/CIRCINTERVENTIONS.114.001225","volume":"7","author":"JJ Meadows","year":"2014","unstructured":"Meadows JJ, Moore PM, Berman DP, Cheatham JP, Cheatham SL, Porras D, Gillespie MJ, Rome JJ, Zahn EM, McElhinney DB (2014) Use and performance of the Melody transcatheter pulmonary valve in native and postsurgical, nonconduit right ventricular outflow tracts. Circ Cardiovasc Interv 7(3):374\u2013380. https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.114.001225","journal-title":"Circ Cardiovasc Interv"},{"issue":"9","key":"2270_CR8","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1136\/hrt.2009.189944","volume":"96","author":"RA Bertels","year":"2010","unstructured":"Bertels RA, Blom NA, Schalij MJ (2010) Edwards SAPIEN transcatheter heart valve in native pulmonary valve position. Heart 96(9):661. https:\/\/doi.org\/10.1136\/hrt.2009.189944","journal-title":"Heart"},{"issue":"5","key":"2270_CR9","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1093\/ejcts\/ezr130","volume":"41","author":"P Guccione","year":"2012","unstructured":"Guccione P, Milanesi O, Hijazi ZM, Pongiglione G (2012) Transcatheter pulmonary valve implantation in native pulmonary outflow tract using the Edwards SAPIEN transcatheter heart valve. Eur J Cardiothorac Surg 41(5):1192\u20131194. https:\/\/doi.org\/10.1093\/ejcts\/ezr130","journal-title":"Eur J Cardiothorac Surg"},{"key":"2270_CR10","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.ijcard.2015.03.108","volume":"186","author":"B Cools","year":"2015","unstructured":"Cools B, Brown SC, Heying R, Jansen K, Boshoff DE, Budts W, Gewillig M (2015) Percutaneous pulmonary valve implantation for free pulmonary regurgitation following conduit-free surgery of the right ventricular outflow tract. Int J Cardiol 186:129\u2013135. https:\/\/doi.org\/10.1016\/j.ijcard.2015.03.108","journal-title":"Int J Cardiol"},{"issue":"1","key":"2270_CR11","doi-asserted-by":"publisher","first-page":"E28","DOI":"10.1002\/ccd.26480","volume":"88","author":"T Rockefeller","year":"2016","unstructured":"Rockefeller T, Shahanavaz S, Zajarias A, Balzer D (2016) Transcatheter implantation of SAPIEN 3 valve in native right ventricular outflow tract for severe pulmonary regurgitation following tetralogy of fallot repair. Catheter Cardiovasc Interv 88(1):E28\u201333. https:\/\/doi.org\/10.1002\/ccd.26480","journal-title":"Catheter Cardiovasc Interv"},{"key":"2270_CR12","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.ijcard.2017.10.015","volume":"250","author":"NA Haas","year":"2018","unstructured":"Haas NA, Carere RG, Kretschmar O, Horlick E, Rodes-Cabau J, de Wolf D, Gewillig M, Mullen M, Lehner A, Deutsch C, Bramlage P, Ewert P (2018) Early outcomes of percutaneous pulmonary valve implantation using the Edwards SAPIEN XT transcatheter heart valve system. Int J Cardiol 250:86\u201391. https:\/\/doi.org\/10.1016\/j.ijcard.2017.10.015","journal-title":"Int J Cardiol"},{"issue":"1","key":"2270_CR13","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1111\/joic.12443","volume":"31","author":"A Esmaeili","year":"2018","unstructured":"Esmaeili A, Bollmann S, Khalil M, De Rosa R, Fichtlscherer S, Akintuerk H, Schranz D (2018) Percutaneous pulmonary valve implantation for reconstruction of a patch-repaired right ventricular outflow tract. J Interv Cardiol 31(1):106\u2013111. https:\/\/doi.org\/10.1111\/joic.12443","journal-title":"J Interv Cardiol"},{"issue":"6","key":"2270_CR14","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1002\/ccd.24594","volume":"81","author":"DE Boshoff","year":"2013","unstructured":"Boshoff DE, Cools BL, Heying R, Troost E, Kefer J, Budts W, Gewillig M (2013) Off-label use of percutaneous pulmonary valved stents in the right ventricular outflow tract: time to rewrite the label? Catheter Cardiovasc Interv 81(6):987\u2013995. https:\/\/doi.org\/10.1002\/ccd.24594","journal-title":"Catheter Cardiovasc Interv"},{"key":"2270_CR15","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.ijcard.2017.11.091","volume":"258","author":"S Georgiev","year":"2018","unstructured":"Georgiev S, Tanase D, Ewert P, Meierhofer C, Hager A, von Ohain JP, Eicken A (2018) Percutaneous pulmonary valve implantation in patients with dysfunction of a \"native\" right ventricular outflow tract\u2014mid-term results. Int J Cardiol 258:31\u201335. https:\/\/doi.org\/10.1016\/j.ijcard.2017.11.091","journal-title":"Int J Cardiol"},{"issue":"4","key":"2270_CR16","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1080\/10976640601187596","volume":"9","author":"S Schievano","year":"2007","unstructured":"Schievano S, Coats L, Migliavacca F, Norman W, Frigiola A, Deanfield J, Bonhoeffer P, Taylor AM (2007) Variations in right ventricular outflow tract morphology following repair of congenital heart disease: implications for percutaneous pulmonary valve implantation. J Cardiovasc Magn Reson 9(4):687\u2013695. https:\/\/doi.org\/10.1080\/10976640601187596","journal-title":"J Cardiovasc Magn Reson"},{"issue":"2","key":"2270_CR17","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1148\/radiol.2422051994","volume":"242","author":"S Schievano","year":"2007","unstructured":"Schievano S, Migliavacca F, Coats L, Khambadkone S, Carminati M, Wilson N, Deanfield JE, Bonhoeffer P, Taylor AM (2007) Percutaneous pulmonary valve implantation based on rapid prototyping of right ventricular outflow tract and pulmonary trunk from MR data. Radiology 242(2):490\u2013497. https:\/\/doi.org\/10.1148\/radiol.2422051994","journal-title":"Radiology"},{"key":"2270_CR18","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1186\/1532-429X-15-51","volume":"15","author":"S Fratz","year":"2013","unstructured":"Fratz S, Chung T, Greil GF, Samyn MM, Taylor AM, Valsangiacomo Buechel ER, Yoo SJ, Powell AJ (2013) Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease. J Cardiovasc Magn Reson 15:51. https:\/\/doi.org\/10.1186\/1532-429X-15-51","journal-title":"J Cardiovasc Magn Reson"},{"issue":"12","key":"2270_CR19","doi-asserted-by":"publisher","first-page":"1764","DOI":"10.1016\/j.amjcard.2009.02.030","volume":"103","author":"S Fratz","year":"2009","unstructured":"Fratz S, Schuhbaeck A, Buchner C, Busch R, Meierhofer C, Martinoff S, Hess J, Stern H (2009) Comparison of accuracy of axial slices versus short-axis slices for measuring ventricular volumes by cardiac magnetic resonance in patients with corrected tetralogy of fallot. Am J Cardiol 103(12):1764\u20131769. https:\/\/doi.org\/10.1016\/j.amjcard.2009.02.030","journal-title":"Am J Cardiol"},{"issue":"1","key":"2270_CR20","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1002\/mrm.21099","volume":"57","author":"P Martirosian","year":"2007","unstructured":"Martirosian P, Greil GF, Fenchel M, Kramer U, Miller S, Greiser A, Claussen CD, Schick F, Sieverding L (2007) Optimization of blood-myocardial contrast in 3D true FISP cardiac imaging at 1.5 T. Magn Reson Med 57(1):213\u2013219. https:\/\/doi.org\/10.1002\/mrm.21099","journal-title":"Magn Reson Med"},{"issue":"4","key":"2270_CR21","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1016\/s0002-9149(00)01394-1","volume":"87","author":"C Kondo","year":"2001","unstructured":"Kondo C, Takada K, Yokoyama U, Nakajima Y, Momma K, Sakai F (2001) Comparison of three-dimensional contrast-enhanced magnetic resonance angiography and axial radiographic angiography for diagnosing congenital stenoses in small pulmonary arteries. Am J Cardiol 87(4):420\u2013424. https:\/\/doi.org\/10.1016\/s0002-9149(00)01394-1","journal-title":"Am J Cardiol"},{"issue":"4","key":"2270_CR22","doi-asserted-by":"publisher","first-page":"902","DOI":"10.2214\/AJR.07.2997","volume":"190","author":"CJ Francois","year":"2008","unstructured":"Francois CJ, Tuite D, Deshpande V, Jerecic R, Weale P, Carr JC (2008) Unenhanced MR angiography of the thoracic aorta: initial clinical evaluation. AJR Am J Roentgenol 190(4):902\u2013906. https:\/\/doi.org\/10.2214\/AJR.07.2997","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2270_CR23","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1002\/jmri.22016","volume":"31","author":"S Potthast","year":"2010","unstructured":"Potthast S, Mitsumori L, Stanescu LA, Richardson ML, Branch K, Dubinsky TJ, Maki JH (2010) Measuring aortic diameter with different MR techniques: comparison of three-dimensional (3D) navigated steady-state free-precession (SSFP), 3D contrast-enhanced magnetic resonance angiography (CE-MRA), 2D T2 black blood, and 2D cine SSFP. J Magn Reson Imaging 31(1):177\u2013184. https:\/\/doi.org\/10.1002\/jmri.22016","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"2270_CR24","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1093\/ehjci\/jev188","volume":"17","author":"P Ruile","year":"2016","unstructured":"Ruile P, Blanke P, Krauss T, Dorfs S, Jung B, Jander N, Leipsic J, Langer M, Neumann FJ, Pache G (2016) Pre-procedural assessment of aortic annulus dimensions for transcatheter aortic valve replacement: comparison of a non-contrast 3D MRA protocol with contrast-enhanced cardiac dual-source CT angiography. Eur Heart J Cardiovasc Imaging 17(4):458\u2013466. https:\/\/doi.org\/10.1093\/ehjci\/jev188","journal-title":"Eur Heart J Cardiovasc Imaging"},{"issue":"7","key":"2270_CR25","doi-asserted-by":"publisher","first-page":"564","DOI":"10.1016\/S1474-4422(17)30158-8","volume":"16","author":"Gulani V, Calamante F, Shellock FG, Kanal E, Reeder SB, International Society for Magnetic Resonance in M","year":"2017","unstructured":"Gulani V, Calamante F, Shellock FG, Kanal E, Reeder SB, International Society for Magnetic Resonance in M (2017) Gadolinium deposition in the brain: summary of evidence and recommendations. Lancet Neurol 16(7):564\u2013570. https:\/\/doi.org\/10.1016\/S1474-4422(17)30158-8","journal-title":"Lancet Neurol"}],"container-title":["Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-019-02270-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00246-019-02270-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-019-02270-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,18]],"date-time":"2020-12-18T01:05:05Z","timestamp":1608253505000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00246-019-02270-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,19]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["2270"],"URL":"https:\/\/doi.org\/10.1007\/s00246-019-02270-5","relation":{},"ISSN":["0172-0643","1432-1971"],"issn-type":[{"value":"0172-0643","type":"print"},{"value":"1432-1971","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,19]]},"assertion":[{"value":"8 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"None of the authors have any conflict of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}},{"value":"Since study design was retrospective, no informed consent was needed.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed Consent"}}]}}