{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T11:37:51Z","timestamp":1778067471167,"version":"3.51.4"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T00:00:00Z","timestamp":1609718400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T00:00:00Z","timestamp":1609718400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Cardiol"],"published-print":{"date-parts":[[2021,3]]},"DOI":"10.1007\/s00246-020-02531-8","type":"journal-article","created":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T06:02:51Z","timestamp":1609740171000},"page":"692-699","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Ultrasound Cardiac Output Monitor (USCOM\u2122) Measurements Prove Unreliable Compared to Cardiac Magnetic Resonance Imaging in Adolescents with Cardiac Disease"],"prefix":"10.1007","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1754-9396","authenticated-orcid":false,"given":"Avichai","family":"Weissbach","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amichay","family":"Rotstein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yaniv","family":"Lakovsky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eytan","family":"Kaplan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gili","family":"Kadmon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Einat","family":"Birk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elhanan","family":"Nahum","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,1,4]]},"reference":[{"key":"2531_CR1","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1097\/CCM.0000000000002425","volume":"45","author":"AL Davis","year":"2017","unstructured":"Davis AL, Carcillo JA, Aneja RK et al (2017) The American College of Critical Care Medicine Clinical Practice Parameters for Hemodynamic Support of paediatric and neonatal septic shock. Pediatr Crit Care Med 45:1061\u20131093. https:\/\/doi.org\/10.1097\/CCM.0000000000002425","journal-title":"Pediatr Crit Care Med"},{"key":"2531_CR2","unstructured":"FDA US Food & Drug Administration, https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K043139; 2019 [accessed October 2019]"},{"key":"2531_CR3","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1213\/01.ANE.0000144774.42408.05","volume":"100","author":"LA Critchley","year":"2005","unstructured":"Critchley LA, Peng ZY, Fok BS, Lee A, Phillips RA (2005) Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth Analg 100:748\u2013753. https:\/\/doi.org\/10.1213\/01.ANE.0000144774.42408.05","journal-title":"Anesth Analg"},{"key":"2531_CR4","first-page":"309","volume":"8","author":"JS Chan","year":"2005","unstructured":"Chan JS, Segara D, Nair P (2005) Measurement of cardiac output with a noninvasive continuous wave Doppler device versus the pulmonary artery catheter: a comparative study. Crit Care Resusc 8:309\u2013314","journal-title":"Crit Care Resusc"},{"key":"2531_CR5","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1053\/j.jvca.2005.05.024","volume":"20","author":"R Chand","year":"2006","unstructured":"Chand R, Mehta Y, Terhan N (2006) Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery. J Cardiothorac Vasc Anesth 20:315\u2013319. https:\/\/doi.org\/10.1053\/j.jvca.2005.05.024","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"2531_CR6","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1016\/j.athoracsur.2004.12.034","volume":"80","author":"K Knobloch","year":"2005","unstructured":"Knobloch K, Lichtenberg A, Winterhalter M, Rossner D, Pichlmaier M, Phillips R (2005) Non-invasive cardiac output determination by two dimensional independent Doppler during and after cardiac surgery. Ann Thorac Surg 80:1479\u20131483. https:\/\/doi.org\/10.1016\/j.athoracsur.2004.12.034","journal-title":"Ann Thorac Surg"},{"key":"2531_CR7","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1093\/bja\/aei054","volume":"94","author":"HL Tan","year":"2005","unstructured":"Tan HL, Pinder M, Parsons R, Roberts B, van Heerden PV (2005) Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth 94:287\u2013291. https:\/\/doi.org\/10.1093\/bja\/aei054","journal-title":"Br J Anaesth"},{"key":"2531_CR8","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1007\/s00134-008-1030-y","volume":"34","author":"W Knirsch","year":"2008","unstructured":"Knirsch W, Kretschmar O, Tomaske M, Stutz K, Nagdyman N, Balmer C et al (2008) Cardiac output measurement in children: comparison of the ultrasound cardiac output monitor with thermodilution cardiac output measurement. Intensive Care Med 34:1060\u20131064. https:\/\/doi.org\/10.1007\/s00134-008-1030-y","journal-title":"Intensive Care Med"},{"key":"2531_CR9","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1007\/s10877-010-9240-6","volume":"24","author":"HB Nguyen","year":"2010","unstructured":"Nguyen HB, Banta DP, Stewart G, Kim T, Bansal R, Anholm J et al (2010) Cardiac index measurement by transcutaneous Doppler ultrasound and transthoracic echocardiography in adult and paediatric emergency patients. J Clin Monit Comput 24:237\u2013247. https:\/\/doi.org\/10.1007\/s10877-010-9240-6","journal-title":"J Clin Monit Comput"},{"key":"2531_CR10","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s00246-015-1261-y","volume":"37","author":"F Beltramo","year":"2016","unstructured":"Beltramo F, Menteer J, Razavi A, Khemani RG, Szmuszkovicz J, Newth CJ et al (2016) Validation of an ultrasound cardiac output monitor as a bedside tool for paediatric patients. Pediatr Cardiol 37:177\u2013183. https:\/\/doi.org\/10.1007\/s00246-015-1261-y","journal-title":"Pediatr Cardiol"},{"key":"2531_CR11","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1111\/j.1460-9592.2010.03480.x","volume":"21","author":"S Dhanani","year":"2011","unstructured":"Dhanani S, Barrowman NJ, Ward RE, Murto KT (2011) Intra- and inter- observer reliability using a noninvasive ultrasound cardiac output monitor in healthy anesthetized children. Paediatr Anaesth 21:858\u2013864. https:\/\/doi.org\/10.1111\/j.1460-9592.2010.03480.x","journal-title":"Paediatr Anaesth"},{"key":"2531_CR12","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1161\/01.CIR.0000083233.86078.3E","volume":"108","author":"GM Pohost","year":"2003","unstructured":"Pohost GM, Hung L, Doyle M (2003) Clinical use of cardiovascular magnetic resonance. Circulation 108:647\u2013653. https:\/\/doi.org\/10.1161\/01.CIR.0000083233.86078.3E","journal-title":"Circulation"},{"key":"2531_CR13","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1136\/heart.85.5.581","volume":"85","author":"D Pennell","year":"2001","unstructured":"Pennell D (2001) Cardiovascular magnetic resonance. Heart 85:581\u2013589. https:\/\/doi.org\/10.1136\/heart.85.5.581","journal-title":"Heart"},{"key":"2531_CR14","doi-asserted-by":"publisher","first-page":"E8","DOI":"10.1002\/clc.20612","volume":"33","author":"F Trinkmann","year":"2010","unstructured":"Trinkmann F, Doesch C, Papavassiliu T, Weissmann J, haghi D, Gruettner J, et al (2010) A novel noninvasive ultrasonic cardiac output monitor: comparison with cardiac magnetic resonance. Clin Cardiol 33:E8-14. https:\/\/doi.org\/10.1002\/clc.20612","journal-title":"Clin Cardiol"},{"key":"2531_CR15","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1016\/0735-1097(92)90282-r","volume":"19","author":"SM Nidorf","year":"1992","unstructured":"Nidorf SM, Picard MH, Triulzi MO, Thomas JD, Newell J, King ME et al (1992) New perspectives in the assessment of cardiac chamber dimensions during development and adulthood. J Am Coll Cardiol 19:983\u2013988. https:\/\/doi.org\/10.1016\/0735-1097(92)90282-r","journal-title":"J Am Coll Cardiol"},{"key":"2531_CR16","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1016\/j.cjca.2014.04.021","volume":"30","author":"CW Chin","year":"2014","unstructured":"Chin CW, Khaw HJ, Luo E, Tan S, White AC, Newby DE et al (2014) Echocardiography underestimates stroke volume and aortic valve area: implications for patients with small-area low-gradient aortic stenosis. Can J Cardiol 30:1064\u20131072. https:\/\/doi.org\/10.1016\/j.cjca.2014.04.021","journal-title":"Can J Cardiol"},{"key":"2531_CR17","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307\u2013310","journal-title":"Lancet"},{"key":"2531_CR18","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1023\/A:1009982611386","volume":"15","author":"LA Critchley","year":"1999","unstructured":"Critchley LA, Critchley JA (1999) A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 15:85\u201391","journal-title":"J Clin Monit Comput"}],"container-title":["Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-020-02531-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00246-020-02531-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-020-02531-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,24]],"date-time":"2021-03-24T14:09:14Z","timestamp":1616594954000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00246-020-02531-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,4]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["2531"],"URL":"https:\/\/doi.org\/10.1007\/s00246-020-02531-8","relation":{},"ISSN":["0172-0643","1432-1971"],"issn-type":[{"value":"0172-0643","type":"print"},{"value":"1432-1971","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,4]]},"assertion":[{"value":"11 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}