{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T16:50:14Z","timestamp":1787503814252,"version":"build-2736575974"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,8,13]],"date-time":"2021-08-13T00:00:00Z","timestamp":1628812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,8,13]],"date-time":"2021-08-13T00:00:00Z","timestamp":1628812800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Cardiol"],"published-print":{"date-parts":[[2022,1]]},"DOI":"10.1007\/s00246-021-02705-y","type":"journal-article","created":{"date-parts":[[2021,8,13]],"date-time":"2021-08-13T12:02:32Z","timestamp":1628856152000},"page":"147-154","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["The Role of External Loop Recorders in Arrhythmia-Related Symptoms in Children: A Single Center Experience"],"prefix":"10.1007","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2747-974X","authenticated-orcid":false,"given":"Tugberk","family":"Akca","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fahrettin","family":"Uysal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ozlem Mehtap","family":"Bostan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdusselam","family":"Genc","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hasan","family":"Turkmen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,8,13]]},"reference":[{"key":"2705_CR1","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s10840-005-4787-8","volume":"14","author":"SS Barold","year":"2005","unstructured":"Barold SS (2005) Norman J. \u201cJeff\u201d Holter-\"Father\" of ambulatory ECG monitoring. J Interv Card Electrophysiol 14:117\u2013118","journal-title":"J Interv Card Electrophysiol"},{"key":"2705_CR2","doi-asserted-by":"publisher","first-page":"1629","DOI":"10.1161\/CIRCULATIONAHA.109.925610","volume":"122","author":"P Zimetbaum","year":"2010","unstructured":"Zimetbaum P, Goldman A (2010) Ambulatory arrhythmia monitoring: choosing the right device. Circulation 122:1629\u20131636","journal-title":"Circulation"},{"key":"2705_CR3","first-page":"11","volume":"11","author":"AH Rees","year":"1985","unstructured":"Rees AH, Solinger R, Elbl F (1985) Holter monitoring in the management of cardiac arrhythmias in children. Compr Ther 11:11\u201316","journal-title":"Compr Ther"},{"key":"2705_CR4","doi-asserted-by":"publisher","first-page":"253","DOI":"10.5455\/aim.2016.24.253-256","volume":"24","author":"Z Begic","year":"2016","unstructured":"Begic Z, Begic E, Mesihovic-Dinarevic S, Masic I, Pesto S, Halimic M, Kadic A, Dobraca A (2016) The use of continuous electrocardiographic Holter monitoring in pediatric cardiology. Acta Inform Med 24:253\u2013256","journal-title":"Acta Inform Med"},{"key":"2705_CR5","first-page":"204","volume":"7","author":"RA Hegazy","year":"2007","unstructured":"Hegazy RA, Lotfy WN (2007) The value of Holter monitoring in the assessment of Pediatric patients. Indian Pacing Electrophysiol J 7:204\u2013214","journal-title":"Indian Pacing Electrophysiol J"},{"key":"2705_CR6","first-page":"286","volume":"42","author":"C Ayabakan","year":"2000","unstructured":"Ayabakan C, Ozer S, Celiker A, Ozme S (2000) Analysis of 2017 Holter records in pediatric patients. Turk J Pediatr 42:286\u2013293","journal-title":"Turk J Pediatr"},{"key":"2705_CR7","doi-asserted-by":"publisher","first-page":"16","DOI":"10.7326\/0003-4819-124-1_Part_1-199601010-00003","volume":"124","author":"S Kinlay","year":"1996","unstructured":"Kinlay S, Leitch JW, Neil A, Chapman BL, Hardy DB, Fletcher PJ (1996) Cardiac event recorders yield more diagnoses and are more cost-effective than 48-hour Holter monitoring in patients with palpitations. A controlled clinical trial. Ann Intern Med 124:16\u201320","journal-title":"Ann Intern Med"},{"key":"2705_CR8","doi-asserted-by":"publisher","first-page":"848","DOI":"10.7326\/0003-4819-130-10-199905180-00020","volume":"130","author":"PJ Zimetbaum","year":"1999","unstructured":"Zimetbaum PJ, Josephson ME (1999) The evolving role of ambulatory arrhythmia monitoring in general clinical practice. Ann Intern Med 130:848\u2013856","journal-title":"Ann Intern Med"},{"key":"2705_CR9","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1111\/j.1542-474X.2007.00199.x","volume":"13","author":"S Sulfi","year":"2008","unstructured":"Sulfi S, Balami D, Sekhri N, Suliman A, Kapur A, Archbold RA, Ranjadayalan K, Timmis AD (2008) Limited clinical utility of Holter monitoring in patients with palpitations or altered consciousness: analysis of 8973 recordings in 7394 patients. Ann Noninvasive Electrocardiol 13:39\u201343","journal-title":"Ann Noninvasive Electrocardiol"},{"key":"2705_CR10","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1016\/j.joa.2017.04.012","volume":"33","author":"R Kohno","year":"2017","unstructured":"Kohno R, Abe H, Benditt DG (2017) Ambulatory electrocardiogram monitoring devices for evaluating transient loss of consciousness or other related symptoms. Journal of arrhythmia 33:583\u2013589","journal-title":"Journal of arrhythmia"},{"key":"2705_CR11","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1111\/anec.12339","volume":"21","author":"M Saygi","year":"2016","unstructured":"Saygi M, Ergul Y, Ozyilmaz I, Sengul FS, Guvenc O, Aslan E, Guzeltas A, Akdeniz C, Tuzcu V (2016) Using a cardiac event recorder in children with potentially arrhythmia-related symptoms. Ann Noninvasive Electrocardiol 21:500\u2013507","journal-title":"Ann Noninvasive Electrocardiol"},{"key":"2705_CR12","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1093\/europace\/eur159","volume":"13","author":"MH Park","year":"2011","unstructured":"Park MH, de Asmundis C, Chierchia GB, Sarkozy A, Benatar A, Brugada P (2011) First experience of monitoring with cardiac event recorder electrocardiography Omron system in childhood population for sporadic, potentially arrhythmia-related symptoms. Europace 13:1335\u20131339","journal-title":"Europace"},{"key":"2705_CR13","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1542\/peds.113.2.248","volume":"113","author":"EV Saarel","year":"2004","unstructured":"Saarel EV, Stefanelli CB, Fischbach PS, Serwer GA, Rosenthal A, Dick M 2nd (2004) Transtelephonic electrocardiographic monitors for evaluation of children and adolescents with suspected arrhythmias. Pediatrics 113:248\u2013251","journal-title":"Pediatrics"},{"key":"2705_CR14","doi-asserted-by":"publisher","first-page":"890","DOI":"10.7326\/0003-4819-128-11-199806010-00002","volume":"128","author":"PJ Zimetbaum","year":"1998","unstructured":"Zimetbaum PJ, Kim KY, Josephson ME, Goldberger AL, Cohen DJ (1998) Diagnostic yield and optimal duration of continuous-loop event monitoring for the diagnosis of palpitations. A cost-effectiveness analysis. Ann Intern Med 128:890\u2013895","journal-title":"Ann Intern Med"},{"key":"2705_CR15","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1093\/fampra\/cmi048","volume":"22","author":"E Hoefman","year":"2005","unstructured":"Hoefman E, van Weert HC, Reitsma JB, Koster RW, Bindels PJ (2005) Diagnostic yield of patient-activated loop recorders for detecting heart rhythm abnormalities in general practice: a randomised clinical trial. Fam Pract 22:478\u2013484","journal-title":"Fam Pract"},{"key":"2705_CR16","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/0022-0736(91)90007-9","volume":"24","author":"JA Reiffel","year":"1991","unstructured":"Reiffel JA, Schulhof E, Joseph B, Severance E, Wyndus P, McNamara A (1991) Optimum duration of transtelephonic ECG monitoring when used for transient symptomatic event detection. J Electrocardiol 24:165\u2013168","journal-title":"J Electrocardiol"},{"key":"2705_CR17","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/S0002-9149(96)00717-5","volume":"79","author":"RI Fogel","year":"1997","unstructured":"Fogel RI, Evans JJ, Prystowsky EN (1997) Utility and cost of event recorders in the diagnosis of palpitations, presyncope, and syncope. Am J Cardiol 79:207\u2013208","journal-title":"Am J Cardiol"},{"key":"2705_CR18","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1093\/europace\/eut337","volume":"16","author":"ET Locati","year":"2014","unstructured":"Locati ET, Vecchi AM, Vargiu S, Cattafi G, Lunati M (2014) Role of extended external loop recorders for the diagnosis of unexplained syncope, pre-syncope, and sustained palpitations. Europace 16:914\u2013922","journal-title":"Europace"},{"key":"2705_CR19","doi-asserted-by":"publisher","first-page":"1265","DOI":"10.1093\/europace\/euv311","volume":"18","author":"ET Locati","year":"2016","unstructured":"Locati ET, Moya A, Oliveira M, Tanner H, Willems R, Lunati M, Brignole M (2016) External prolonged electrocardiogram monitoring in unexplained syncope and palpitations: results of the SYNARR-Flash study. Europace 18:1265\u20131272","journal-title":"Europace"},{"key":"2705_CR20","doi-asserted-by":"publisher","first-page":"2631","DOI":"10.1093\/eurheartj\/ehp290","volume":"30","author":"A Moya","year":"2009","unstructured":"Moya A, Sutton R, Ammirati F, Blanc JJ, Brignole M, Dahm JB, Deharo JC, Gajek J, Gjesdal K, Krahn A, Massin M, Pepi M, Pezawas T, Ruiz Granell R, Sarasin F, Ungar A, van Dijk JG, Walma EP, Wieling W (2009) Guidelines for the diagnosis and management of syncope (version 2009). Eur Heart J 30:2631\u20132671","journal-title":"Eur Heart J"},{"key":"2705_CR21","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1093\/europace\/eur343","volume":"14","author":"S Davis","year":"2012","unstructured":"Davis S, Westby M, Pitcher D, Petkar S (2012) Implantable loop recorders are cost-effective when used to investigate transient loss of consciousness which is either suspected to be arrhythmic or remains unexplained. Europace 14:402\u2013409","journal-title":"Europace"},{"key":"2705_CR22","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1007\/s10840-008-9251-0","volume":"22","author":"D Scherr","year":"2008","unstructured":"Scherr D, Dalal D, Henrikson CA, Spragg DD, Berger RD, Calkins H, Cheng A (2008) Prospective comparison of the diagnostic utility of a standard event monitor versus a \u201cleadless\u201d portable ECG monitor in the evaluation of patients with palpitations. J Interv Card Electrophysiol 22:39\u201344","journal-title":"J Interv Card Electrophysiol"},{"key":"2705_CR23","first-page":"5625","volume":"2011","author":"RK Albright","year":"2011","unstructured":"Albright RK, Goska BJ, Hagen TM, Chi MY, Cauwenberghs G, Chiang PY (2011) OLAM: A wearable, non-contact sensor for continuous heart-rate and activity monitoring. Annu Int Conf IEEE Eng Med Biol Soc 2011:5625\u20135628","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"2705_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0002-9343(03)00233-X","volume":"115","author":"S Sivakumaran","year":"2003","unstructured":"Sivakumaran S, Krahn AD, Klein GJ, Finan J, Yee R, Renner S, Skanes AC (2003) A prospective randomized comparison of loop recorders versus Holter monitors in patients with syncope or presyncope. Am J Med 115:1\u20135","journal-title":"Am J Med"},{"key":"2705_CR25","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1016\/j.mcna.2019.05.005","volume":"103","author":"KJ Quan","year":"2019","unstructured":"Quan KJ (2019) Palpitation: extended electrocardiogram monitoring: which tests to use and when. Med Clin North Am 103:785\u2013791","journal-title":"Med Clin North Am"},{"key":"2705_CR26","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1111\/ped.12530","volume":"57","author":"Y Ergul","year":"2015","unstructured":"Ergul Y, Tanidir IC, Ozyilmaz I, Akdeniz C, Tuzcu V (2015) Evaluation rhythm problems in unexplained syncope etiology with implantable loop recorder. Pediatr Int 57:359\u2013366","journal-title":"Pediatr Int"},{"key":"2705_CR27","doi-asserted-by":"publisher","first-page":"e228","DOI":"10.1542\/peds.112.3.e228","volume":"112","author":"J Rossano","year":"2003","unstructured":"Rossano J, Bloemers B, Sreeram N, Balaji S, Shah MJ (2003) Efficacy of implantable loop recorders in establishing symptom-rhythm correlation in young patients with syncope and palpitations. Pediatrics 112:e228-233","journal-title":"Pediatrics"},{"key":"2705_CR28","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1111\/j.1540-8159.2008.00995.x","volume":"31","author":"PA Frangini","year":"2008","unstructured":"Frangini PA, Cecchin F, Jordao L, Martuscello M, Alexander ME, Triedman JK, Walsh EP, Berul CI (2008) How revealing are insertable loop recorders in pediatrics? Pacing Clini Electrophysiol 31:338\u2013343","journal-title":"Pacing Clini Electrophysiol"},{"key":"2705_CR29","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1111\/j.1540-8159.2009.02486.x","volume":"32","author":"KN Al Dhahri","year":"2009","unstructured":"Al Dhahri KN, Potts JE, Chiu CC, Hamilton RM, Sanatani S (2009) Are implantable loop recorders useful in detecting arrhythmias in children with unexplained syncope? Pacing Clin Electrophysiol 32:1422\u20131427","journal-title":"Pacing Clin Electrophysiol"},{"key":"2705_CR30","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1017\/S1047951106001156","volume":"16","author":"M Gass","year":"2006","unstructured":"Gass M, Apitz C, Salehi-Gilani S, Ziemer G, Hofbeck M (2006) Use of the implantable loop recorder in children and adolescents. Cardiol Young 16:572\u2013578","journal-title":"Cardiol Young"}],"container-title":["Pediatric Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-021-02705-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00246-021-02705-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00246-021-02705-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,18]],"date-time":"2022-01-18T05:04:46Z","timestamp":1642482286000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00246-021-02705-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,13]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,1]]}},"alternative-id":["2705"],"URL":"https:\/\/doi.org\/10.1007\/s00246-021-02705-y","relation":{},"ISSN":["0172-0643","1432-1971"],"issn-type":[{"value":"0172-0643","type":"print"},{"value":"1432-1971","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,13]]},"assertion":[{"value":"12 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 August 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The authors declare that all the procedures that contributed to this work were carried out in compliance with the ethical standards of the relevant national guidelines on human experimentation and with the Helsinki Declaration of 1975, as revised in 2008, and were approved by the relevant institutional committees.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}}]}}